978 resultados para Systolic array
Resumo:
Lossless compression algorithms of the Lempel-Ziv (LZ) family are widely used nowadays. Regarding time and memory requirements, LZ encoding is much more demanding than decoding. In order to speed up the encoding process, efficient data structures, like suffix trees, have been used. In this paper, we explore the use of suffix arrays to hold the dictionary of the LZ encoder, and propose an algorithm to search over it. We show that the resulting encoder attains roughly the same compression ratios as those based on suffix trees. However, the amount of memory required by the suffix array is fixed, and much lower than the variable amount of memory used by encoders based on suffix trees (which depends on the text to encode). We conclude that suffix arrays, when compared to suffix trees in terms of the trade-off among time, memory, and compression ratio, may be preferable in scenarios (e.g., embedded systems) where memory is at a premium and high speed is not critical.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização - Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de Especialização: Ultrassonografia Cardiovascular
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
O presente trabalho consiste na implementação em hardware de unidades funcionais dedicadas e optimizadas, para a realização das operações de codificação e descodificação, definidas na norma de codificação com perda Joint Photographic Experts Group (JPEG), ITU-T T.81 ISO/IEC 10918-1. Realiza-se um estudo sobre esta norma de forma a caracterizar os seus principais blocos funcionais. A finalidade deste estudo foca-se na pesquisa e na proposta de optimizações, de forma a minimizar o hardware necessário para a realização de cada bloco, de modo a que o sistema realizado obtenha taxas de compressão elevadas, minimizando a distorção obtida. A redução de hardware de cada sistema, codificador e descodificador, é conseguida à custa da manipulação das equações dos blocos Forward Discrete Cosine Transform (FDCT) e Quantificação (Q) e dos blocos Forward Discrete Cosine Transform (IDCT) e Quantificação Inversa (IQ). Com as conclusões retiradas do estudo e através da análise de estruturas conhecidas, descreveu-se cada bloco em Very-High-Speed Integrated Circuits (VHSIC) Hardware Description Language (VHDL) e fez-se a sua síntese em Field Programmable Gate Array (FPGA). Cada sistema implementado recorre à execução de cada bloco em paralelo de forma a optimizar a codificação/descodificação. Assim, para o sistema codificador, será realizada a operação da FDCT e Quantificação sobre duas matrizes diferentes e em simultâneo. O mesmo sucede para o sistema descodificador, composto pelos blocos Quantificação Inversa e IDCT. A validação de cada bloco sintetizado é executada com recurso a vectores de teste obtidos através do estudo efectuado. Após a integração de cada bloco, verificou-se que, para imagens greyscale de referência com resolução de 256 linhas por 256 colunas, é necessário 820,5 μs para a codificação de uma imagem e 830,5 μs para a descodificação da mesma. Considerando uma frequência de trabalho de 100 MHz, processam-se aproximadamente 1200 imagens por segundo.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Especialização: Ressonância Magnética.
Resumo:
Introdução – A medição da pressão arterial (PA), utilizando dispositivos automáticos, é frequentemente realizada na prática clínica e na automedição, permitindo adquirir informação fiável para o diagnóstico, controlo e tratamento da hipertensão arterial. Porém, muitos dos dispositivos automáticos disponíveis no mercado não estão validados segundo protocolos existentes para o efeito. O objetivo do estudo foi confirmar a validação do dispositivo de medição automática da PA, OMRON® M6 Comfort, segundo o Protocolo Internacional da European Society of Hypertension (ESH), de 2010, para a validação de dispositivos de medição automática da PA em adultos. Metodologia – Foram estudados 33 indivíduos, aos quais foram realizadas 9 medições sequenciais da PA, no braço esquerdo, com um esfignomanómetro aneróide alternando com o dispositivo automático. Seguidamente avaliaram-se as diferenças entre os valores obtidos pelos dispositivos para a pressão arterial sistólica (PAS) e diastólica (PAD), classificando-as em três níveis (≤ 5, ≤ 10 ou ≤ 15 mmHg). O número das diferenças em cada nível foi comparado ao requerido pelo Protocolo (fase 1.1). Para cada sujeito foi ainda determinado o número de diferenças com valores ≤ 5 mmHg. Pelo menos 24 dos 33 indivíduos devem ter 2 ou 3 diferenças com valores ≤ 5 mmHg e no máximo 3 dos 33 indivíduos podem apresentar as 3 diferenças com valores > 5 mmHg (fase 1.2). Resultados – O dispositivo OMRON® M6 Comfort foi aprovado nas fases 1.1 e 1.2 para a PAS e PAD. A média das diferenças entre as medições da PA, determinada pelos dispositivos automático e manual, foi de -0,82 ± 5,62 mmHg para a PAS e 2,14 ± 5,15 mmHg para a PAD. Considerações Finais – O dispositivo OMRON® M6 Comfort é válido para a medição da PA em adultos, de acordo com o Protocolo Internacional da ESH, de 2010. - ABSTRACT - Introduction – The measurement of blood pressure (BP) using automatic devices is often performed in clinical practice and self-measurement allowing the acquisition of reliable information for the diagnosis, monitoring and treatment of hypertension. However not all of the automated devices available in the market are validated in accordance with the existing protocols for this purpose. The purpose of this study was to confirm the validation of the automatic measuring device of the BP, OMRON® M6 Comfort, according to the “European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults”. Methodology – The study involved 33 subjects, in each one of them, 9 sequential measurements of BP were performed, in the left arm, with the aneroid sphygmomanometer alternating with the automatic device. Afterwards, the differences on the values obtained by the different devices were evaluated, for systolic blood pressure (SBP) and diastolic (DBP), and these differences were then classified into three levels (≤ 5, ≤ 10 or ≤ 15 mmHg). The number of differences at each level was compared to the number required by the protocol (phase 1.1). For each subject the number of differences with values ≤ 5 mmHg was also determined. At least 24 of the 33 subjects should have 2 or 3 differences with values ≤ 5 mmHg and a maximum of 3 of the 33 subjects may have all differences with values > 5 mmHg (phase 1.2). Results – The device OMRON M6 Comfort ® was approved in phases 1.1 and 1.2 for SBP and DBP. The average difference between measurements of BP, as determined by automatic and manual devices, was -0.82 ± 5.62 mmHg for SBP and 2.14 ± 5.15 mmHg for DBP. Conclusion – The device OMRON M6 Comfort® is valid for measuring BP in adults, according to the ESH International Protocol of 2010.
Resumo:
Toxic amides, such as acrylamide, are potentially harmful to Human health, so there is great interest in the fabrication of compact and economical devices to measure their concentration in food products and effluents. The CHEmically Modified Field Effect Transistor (CHEMFET) based onamorphous silicon technology is a candidate for this type of application due to its low fabrication cost. In this article we have used a semi-empirical modelof the device to predict its performance in a solution of interfering ions. The actual semiconductor unit of the sensor was fabricated by the PECVD technique in the top gate configuration. The CHEMFET simulation was performed based on the experimental current voltage curves of the semiconductor unit and on an empirical model of the polymeric membrane. Results presented here are useful for selection and design of CHEMFET membranes and provide an idea of the limitations of the amorphous CHEMFET device. In addition to the economical advantage, the small size of this prototype means it is appropriate for in situ operation and integration in a sensor array.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Ultrassonografia Cardiovascular.
Resumo:
A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.
Resumo:
Development of Dual Source Computed Tomography (Definition, Siemens Medical Solutions, Erlanger, Germany) allowed advances in temporal resolution, with the addition of a second X-ray source and an array of detectors to the TCM 64 slices. The ability to run exams on Dual Energy, allows greater differentiation of tissues, showing differences between closer attenuation coefficients. In terms of renal applications, the distinction of kidney stones and masses become one of the main advantages of the use of dual-energy technology. This article pretends to demonstrate operating principles of this equipment, as its main renal applications.
Resumo:
Microbial adhesion is a field of recognized relevance and, as such, an impressive array of tools has been developed to understand its molecular mechanisms and ultimately for its quantification. Some of the major limitations found within these methodologies concern the incubation time, the small number of cells analyzed, and the operator's subjectivity. To overcome these aspects, we have developed a quantitative method to measure yeast cells' adhesion through flow cytometry. In this methodology, a suspension of yeast cells is mixed with green fluorescent polystyrene microspheres (uncoated or coated with host proteins). Within 2 h, an adhesion profile is obtained based on two parameters: percentage and cells-microsphere population's distribution pattern. This flow cytometry protocol represents a useful tool to quantify yeast adhesion to different substrata in a large scale, providing manifold data in a speedy and informative manner.