954 resultados para Sapo Campus


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Remote Labs are an emergent educational resource in Engineering, which addresses the remote delivery of practical contents, i. e. remote experiments, through the web. This resource may either be used as a support for e-learning courses in Engineering or Science, in the cases where on-campus lab work is not possible, or as a complement to face-to-face lab classes, allowing the students to repeat a given experiment on a remote fashion, without time restrictions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente, perfil Gestão e Sistemas Ambientais

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Civil – Ramo Tecnologias da Construção

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nesta dissertação pretende-se caracterizar o desempenho energético de um grande edifício de serviços existente, da tipologia ensino, avaliar e identificar potenciais medidas que melhorem aquele desempenho, permitindo, em complemento, determinar a sua classificação energética no âmbito da legislação vigente. A pertinência do estudo prende-se com a avaliação do desempenho energético dos edifícios e com o estudo de medidas de melhoria que permitam incrementar a eficiência energética, por recurso a um programa de simulação energética dinâmica certificado – DesignBuilder e tendo em conta a regulamentação portuguesa em vigor. Inicialmente procedeu-se à modelação do edifício com recurso ao programa DesignBuilder, e, simultaneamente, realizou-se um levantamento de todas as suas características ao nível de geometria, pormenores construtivos, sistemas AVAC e de iluminação e fontes de energia utilizadas. Com vista à caracterização do modo de operação do edifício, foi realizado um levantamento dos perfis reais de utilização em termos de ocupação, iluminação e equipamentos para os vários espaços. Foram realizadas medições de caudais de ar novo e da temperatura do ar, em alguns equipamentos e alguns espaços específicos. Foram realizadas medições em tempo real e leituras de contagens da energia eléctrica utilizada, quer em período de aulas quer em período de férias, que permitiram a desagregação das facturas da energia eléctrica que se apresentam globais para o campus do ISEP. Foram realizadas leituras de contagens de gás natural. Em sequência, foi realizada a simulação energética dinâmica com o intuito de ajustar o modelo criado aos consumos reais e de analisar medidas de melhoria que lhe conferissem um melhor desempenho energético. Essas medidas são agrupadas em quatro tipos: - Medidas de natureza comportamental; - Medidas de melhoria da eficiência energética nos sistemas de iluminação; - Medidas de melhoria de eficiência energética nos sistemas AVAC;- Medidas que visam a introdução de energias de fonte renovável; Em sequência, foi elaborada a simulação nominal e calculados os indicadores de eficiência energética com vista à respectiva classificação energética do edifício, tendo o edifício apresentado uma Classe Energética D de acordo com a escala do SCE. Finalmente, foi avaliado o impacto das diferentes medidas de melhoria identificadas e com potencial de aplicação, isto é, que apresentaram um retorno simples do investimento inferior a oito anos, tanto ao nível do desempenho energético real do edifício, como ao nível da sua classificação energética. De onde se concluiu que existe um potencial de 7% de redução nos consumos energéticos actuais do edifício e de 18% se o funcionamento do edifício for em pleno, ou seja, se todos os seus sistemas estiverem efectivamente em funcionamento, e que terá impacto na classificação energética alcançado uma Classe Energética C.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As alterações climáticas e as emissões de CO2 são questões que suscitam a nível internacional e nacional o desenvolvimento de estratégias que atenuem os seus impactes. A Eficiência Energética (EE) é essencial para que num futuro próximo não haja impactes significativos no meio ambiente devido a elevado e ineficiente consumo energético. A União Europeia (UE) e Portugal têm desenvolvido políticas e programas que estimulam a eficiência energética, bem como a diminuição de gases com efeito de estufa (GEE) e a promoção da utilização de fontes de energia renovável. Por outro lado vivemos numa sociedade que passa cerca de 80% do seu tempo em edifícios e, nestes, é consumida 40% da energia mundial. Com uma dependência energética superior a 80%, Portugal tem vindo a apostar, nos últimos anos, em fontes de energia renovável. Esta aposta serve como substituição de fontes, mas não leva directamente à redução de consumos. A redução da factura de energia só pode ser atingida com uma maior eficiência energética e melhores práticas de gestão de energia em edifícios, transportes e industria. Esta dissertação centra-se especificamente num conjunto de edifícios públicos, património municipal da autarquia de Matosinhos, cujo modelo de fornecimento da energia eléctrica é passível de análise crítica no sentido de uma optimização radical ao nível da concepção da rede e exploração, com consequente redução de custos ao nível da facturação. Esta nova metodologia de exploração e gestão de sistemas eléctricos incidirá na criação de um “campus” energético autárquico resultante do novo layout da rede e respectivo fornecimento de energia a partir da rede de distribuição pública. O estudo permitirá fornecer ferramentas fundamentais para a gestão municipal e empresarial ao nível da sustentabilidade energética nos edifícios públicos com abrangência aos serviços empresariais. De referir que a gestão das instalações eléctricas para optimização do desempenho, eficiência e qualidade de energia é aplicável aos 308 municípios nacionais com relevância para as empresas que apresentam consumos significativos nos seus edifícios. Enquanto funcionário da Câmara Municipal de Matosinhos, este município foi uma escolha natural como referência, na análise da relação existente entre a administração local e a gestão da energia. Para ajudar à análise foi efectuado um benchmarketing a cinco edifícios municipais: Edifício dos Paços do Concelho, Biblioteca Municipal Florbela Espanca, Palacete Visconde Trevões, ex-Edifício dos SMAS e Edifício do ex-Tribunal, visando potenciar a correcta gestão de energia destes edifícios por parte das entidades que os gerem, perante novas oportunidades de melhoria e soluções encontradas. Como contributo às metas impostas pela Directiva 2009/28/CE para 2020, a qual prevê uma redução de 20% no consumo final de energia através da eficiência energética, a incorporação de 20% de energia renovável no consumo energético global e a consequente redução em 20% da emissão de GEE, é apresentado um estudo ao nível de um parque fotovoltaico com a componente técnica e económica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente, perfil Gestão e Sistemas Ambientais

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Based on the paper presented at the International Conference “Autonomous Systems: inter-relations of technical and societal issues”, organized by IET with the support of the Portuguese-German collaboration project on “Technology Assessment of Autonomous Robotics” (DAAD/CRUP) at FCT-UNL, Biblioteca da UNL, Campus de Caparica on 5-6 November 2009.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho de Projeto realizado para obtenção do grau de Mestre em Engenharia Informática e de Computadores

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we describe a low cost distributed system intended to increase the positioning accuracy of outdoor navigation systems based on the Global Positioning System (GPS). Since the accuracy of absolute GPS positioning is insufficient for many outdoor navigation tasks, another GPS based methodology – the Differential GPS (DGPS) – was developed in the nineties. The differential or relative positioning approach is based on the calculation and dissemination of the range errors of the received GPS satellites. GPS/DGPS receivers correlate the broadcasted GPS data with the DGPS corrections, granting users increased accuracy. DGPS data can be disseminated using terrestrial radio beacons, satellites and, more recently, the Internet. Our goal is to provide mobile platforms within our campus with DGPS data for precise outdoor navigation. To achieve this objective, we designed and implemented a three-tier client/server distributed system that, first, establishes Internet links with remote DGPS sources and, then, performs campus-wide dissemination of the obtained data. The Internet links are established between data servers connected to remote DGPS sources and the client, which is the data input module of the campus-wide DGPS data provider. The campus DGPS data provider allows the establishment of both Intranet and wireless links within the campus. This distributed system is expected to provide adequate support for accurate outdoor navigation tasks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of the work presented in this paper is to provide mobile platforms within our campus with a GPS based data service capable of supporting precise outdoor navigation. This can be achieved by providing campus-wide access to real time Differential GPS (DGPS) data. As a result, we designed and implemented a three-tier distributed system that provides Internet data links between remote DGPS sources and the campus and a campus-wide DGPS data dissemination service. The Internet data link service is a two-tier client/server where the server-side is connected to the DGPS station and the client-side is located at the campus. The campus-wide DGPS data provider disseminates the DGPS data received at the campus via the campus Intranet and via a wireless data link. The wireless broadcast is intended for portable receivers equipped with a DGPS wireless interface and the Intranet link is provided for receivers with a DGPS serial interface. The application is expected to provide adequate support for accurate outdoor campus navigation tasks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The accuracy of the Navigation Satellite Timing and Ranging (NAVSTAR) Global Positioning System (GPS) measurements is insufficient for many outdoor navigation tasks. As a result, in the late nineties, a new methodology – the Differential GPS (DGPS) – was developed. The differential approach is based on the calculation and dissemination of the range errors of the GPS satellites received. GPS/DGPS receivers correlate the broadcasted GPS data with the DGPS corrections, granting users increased accuracy. DGPS data can be disseminated using terrestrial radio beacons, satellites and, more recently, the Internet. Our goal is to provide mobile platforms within our campus with DGPS data for precise outdoor navigation. To achieve this objective, we designed and implemented a three-tier client/server distributed system that establishes Internet links with remote DGPS sources and performs campus-wide dissemination of the obtained data. The Internet links are established between data servers connected to remote DGPS sources and the client, which is the data input module of the campus-wide DGPS data provider. The campus DGPS data provider allows the establishment of both Intranet and wireless links within the campus. This distributed system is expected to provide adequate support for accurate (submetric) outdoor navigation tasks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Civil

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa, para obtenção do Grau de Mestre em Energia e Bioenergia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: O controlo postural (CP) constitui um dos requisitos indispensáveis para a execução de muitas tarefas funcionais, tendo sido demonstrado que após um acidente vascular encefálico (AVE) este esteja severamente alterado. Os mecanismos de neuroplasticidade evidenciam capacidade de mudança no CP através de uma intervenção em Fisioterapia. Objetivo: Avaliar a influência da modificação de componentes do membro inferior/tronco inferior (TI) na modificação de componentes da cintura escapular/tronco superior (TS), e a sua influência em variáveis representativas do CP no Sit-to-Stand (STS). Metodologia: O estudo apresenta três casos após AVE, que realizaram intervenção em fisioterapia baseada no conceito de Bobath, durante 11 semanas. Antes e após a intervenção, foi avaliado o alinhamento do tronco e o postural setting da escápula; variáveis associadas ao deslocamento e velocidade do Centro de Pressão (CoP); força, área de contacto e pressão média, durante a sequência do STS, recorrendo ao software SAPo e à plataforma de pressões EMED . Avaliou-se ainda os itens da Classificação Internacional de Funcionalidade (CIF). Resultados: Após a intervenção, os indivíduos em estudo apresentaram um melhor alinhamento do tronco, associado a um melhor postural setting da escápula, no conjunto postural sentado; bem como uma diminuição do deslocamento e velocidade máxima do CoP, no período estável (posição de sentado) e um aumento global da velocidade do CoP, no seat-off, o que parece refletir uma melhoria do CP. Quanto à CIF também se verificou uma diminuição da restrição na participação e limitação na atividade. Conclusão: A modificação de componentes neuro-motores através de uma intervenção baseada no conceito de Bobath teve efeitos positivos do ponto de vista do CP, relacionado com uma melhor relação entre membro inferior/TI e cintura escapular/TS, evidenciando uma melhor relação entre TS/TI nos três indivíduos após AVE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: Lesões como o AVE interferem com a capacidade de recrutar níveis adequados de atividade muscular, podendo levar ao aparecimento de movimentos compensatórios como a excessiva translação anterior do tronco, associada ao gesto de alcance. Objetivos: Descrever a relação entre a atividade dos estabilizadores da omoplata e o movimento compensatório do tronco no gesto de alcance, em 4 indivíduos pós AVE. Pretendeu-se também analisar o papel dos estabilizadores da omoplata na função do membro superior. Métodos: Quatro indivíduos com diagnóstico de AVE, que apresentavam alterações no nível de actividade dos estabilizadores da omoplata contralesional, foram sujeitos a uma avaliação realizada em três momentos, antes (M0), durante (M1) e após (M2) e a um período de intervenção, segundo os princípios do Conceito de Bobath. Recorreu-se à electromiografia de superfície para avaliar a atividade e o timming dos músculos grande dorsal, trapézio superior e trapézio inferior do hemicorpo contralesional e ao software de Avaliação Postural (SAPO) para analisar o deslocamento do tronco no sentido anterior, associados à realização do gesto de alcance. Foram aplicadas as escalas RPS e MESUPES para avaliar as componentes de movimento do gesto de alcance e a função do membro superior, respetivamente. Recorreu-se ao registo fotográfico para análise dos componentes de movimento na posição de sentado e em pé.Resultados: Os dados eletromiográficos registam atividade dos estabilizadores da omoplata unicamente num indivíduo em M2. A análise do deslocamento anterior do tronco revela melhorias em M1 em todos os indivíduos, sendo que em M2 essa evolução positiva não foi observada em três dos participantes. Entre M0 e M2, na escala RPS registam-se melhorias de 7 a 9 pontos no alvo próximo e de 5 a 10 pontos no alvo distante. Na escala MESUPES verificam-se melhorias entre 5 a 18 pontos na sub-escala braço e entre 5 a 8 pontos na sub-escala mão, em M2. A avaliação do registo fotográfico revela modificações nos componentes de movimento dos quatro indivíduos, nomeadamente na integração dos MI na base de suporte, na atividade do tronco inferior e superior e no alinhamento do MS contralesional. Conclusão: A melhoria do nível da atividade dos estabilizadores dinâmicos da omoplata sugere ter influência na diminuição do movimento compensatório do tronco no gesto de alcance e parece ter um papel na melhoria da eficácia distal do MS do mesmo lado.