937 resultados para Planar Filters
Resumo:
The suitability of a new plastic supporting medium for biofiltration was tested over a three year period. Tests were carried out on the stability, surface properties, mechanical strength, and dimensions of the medium. There was no evidence to suggest that the medium was deficient in any of these respects. The specific surface (320m2m-3) and the voidage (94%) of the new medium are unlike any other used in bio-filtration and a pilot plant containing two filters was built to observe its effects on ecology and performance. Performance was estimated by chemical analysis and ecology studied by film examination and fauna counts. A system of removable sampling baskets was designed to enable samples to be obtained from two intermediate depths of filter. One of the major operating problems of percolating filters is excessive accumulation of film. The amount of film is influenced by hydraulic and organic load and each filter was run at a different loading. One was operated at 1.2m3m-3day-1 (DOD load 0.24kgm-3day-1) judged at the time to be the lowest filtration rate to offer advantages over conventional media. The other filter was operated at more than twice this loading (2.4m3m-3day-lBOD load 0.55kgm-3day-1) giving a roughly 2.5x and 6x the conventional loadings recommended for a Royal Commission effluent. The amount of film in each filter was normally low (0.05-3kgm(3 as volatile solids) and did not affect efficiency. The evidence collected during the study indicated that the ecology of the filters was normal when compared with the data obtained from the literature relating to filters with mineral media. There were indications that full ecological stability was yet to be reached and this was affecting the efficiency of the filters. The lower rate filter produced an average 87% BOD removal giving a consistent Royal Commission effluent during the summer months. The higher rate filter produced a mean 83% BOD removal but at no stage a consistent Royal Commission effluent. From the data on ecology and performance the filters resembled conventional filters rather than high rate filters.
Resumo:
Pilot scale studies of high rate filtration were initiated to assess its potential as either a primary 'roughing' filter to alleviate the seasonal overloading of low rate filters on Hereford sewage treatment works - caused by wastes from cider production - or as a two stage high rate process to provide complete sewage treatment. Four mineral and four plastic primary filter media and two plastic secondary filter media were studied. The hydraulic loading applied to the primary plastic media (11.2 m3 /m3 .d) was twice that applied to the mineral media. The plastic media removed an average around 66 percent and the mineral media around 73 percent of the BOD applied when the 90 percentile BOD concentration was 563 mg/1. At a hydraulic loading of 4 m3 /m3 .d the secondary filters removed most of the POD from partially settled primary filter effluents, with one secondary effluent satisfying a 25 mg/1 BOD and 30 mg/1 SS standard. No significant degree of nitrification was achieved. Fungi dominated the biological film of the primary filters, with invertebrate grazers having little influence on film levels. Ponding did not arise, and modular media supported lower film levels than random-fill types. Secondary filter film levels were low, being dominated by bacteria. The biological loading applied to the filters was related to sludge dewaterability, with the most readily conditionable sludges produced by filters supporting heavy film. Sludges produced by random-fill media could be dewatered as readily as those produced by low rate filters treating the same sewage. Laboratory scale studies showed a relationship between log effluent BOD and nitrification achieved by biological filters. This relationship and the relationship between BOD load applied and removed observed in all filter media could he used to optimise operating conditions required in biological filters to achieve given effluent BOD and ammoniacal nitrogen standards.
Resumo:
Masking, adaptation, and summation paradigms have been used to investigate the characteristics of early spatio-temporal vision. Each has been taken to provide evidence for (i) oriented and (ii) nonoriented spatial-filtering mechanisms. However, subsequent findings suggest that the evidence for nonoriented mechanisms has been misinterpreted: those experiments might have revealed the characteristics of suppression (eg, gain control), not excitation, or merely the isotropic subunits of the oriented detecting mechanisms. To shed light on this, we used all three paradigms to focus on the ‘high-speed’ corner of spatio-temporal vision (low spatial frequency, high temporal frequency), where cross-oriented achromatic effects are greatest. We used flickering Gabor patches as targets and a 2IFC procedure for monocular, binocular, and dichoptic stimulus presentations. To account for our results, we devised a simple model involving an isotropic monocular filter-stage feeding orientation-tuned binocular filters. Both filter stages are adaptable, and their outputs are available to the decision stage following nonlinear contrast transduction. However, the monocular isotropic filters (i) adapt only to high-speed stimuli—consistent with a magnocellular subcortical substrate—and (ii) benefit decision making only for high-speed stimuli (ie, isotropic monocular outputs are available only for high-speed stimuli). According to this model, the visual processes revealed by masking, adaptation, and summation are related but not identical.
Resumo:
Background Yellow filters are sometimes recommended to people with low vision. Our aim was investigate the effects of three commercial yellow filters on visual acuity and contrast sensitivity (with and without glare) and reading (without glare) under conditions of forward light scatter (FLS). Method Fifty-five healthy subjects were assessed with Corning Photochromic Filters (CPFs) 450, 511 and 527 and a filter producing FLS. The effects on log MAR visual acuity, Pelli–Robson contrast sensitivity with and without glare, and reading (measured with MNRead charts) without glare were determined. Results Statistically significant differences were found between the overall effect of glare and between CPFs for visual acuity and contrast sensitivity. A gradual decline in visual acuity, contrast sensitivity and reading with increasing CPF absorption was noted. Conclusion Effects of CPF450, 511, 527 on visual acuity, contrast sensitivity and reading under conditions of FLS were negative but not clinically significant.
Resumo:
Visual stress is a condition characterised by symptoms of eyestrain, headaches and distortions of visual perception when reading text. The symptoms are frequently alleviated with spectral filters and precision tinted ophthalmic lenses. Visual stress is thought to arise due to cortical hyperexcitability and is associated with a range of neurological conditions. Cortical hyperexcitability is known to occur following stroke. The case presented describes visual stress symptoms resulting from stroke, subsequently managed with spectral filters and precision tinted ophthalmic lenses. The case also highlights that the spectral properties of the tint may need to be modified if the disease course alters.
Resumo:
The present thesis investigates pattern glare susceptibility following stroke and the immediate and prolonged impact of prescribing optimal spectral filters on reading speed, accuracy and visual search performance. Principal observations: A case report has shown that visual stress can occur following stroke. The use of spectral filters and precision tinted lenses proved to be a successful intervention in this case, although the parameters required modification following a further stroke episode. Stroke subjects demonstrate elevated levels of pattern glare compared to normative data values and a control group. Initial use of an optimal spectral filter in a stroke cohort increased reading speed by ~6% and almost halved error scores, findings not replicated in a control group. With the removal of migraine subjects reading speed increased by ~8% with an optimal filter and error scores almost halved. Prolonged use of an optimal spectral filter for stroke subjects, increased reading speed by >9% and error scores more than halved. When the same subjects switched to prolonged use of a grey filter, reading speed reduced by ~4% and error scores increased marginally. When a second group of stroke subjects used a grey filter first, reading speed decreased by ~3% but increased by ~3% with prolonged use of an optimal filter, with error scores almost halving; these findings persisted with migraine subjects excluded. Initial use of an optimal spectral filter improved visual search response time but not error scores in a stroke cohort with migraine subjects excluded. Neither prolonged use of an optimal nor grey filter improved response time or reduced error scores in a stroke group; these findings persisted with the exclusion of migraine subjects.
Resumo:
Background: The aim was to investigate the visual effect of coloured filters compared to transmission-matched neutral density filters, in patients with dry age-related macular degeneration. Methods: Visual acuity (VA, logMAR), contrast sensitivity (Pelli-Robson) and colour vision (D15) were recorded for 39 patients (average age 79.1 ± 7.2 years) with age-related macular degeneration, both in the presence and absence of glare from a fluorescent source. Patients then chose their preferred coloured and matched neutral density transmission filters (NoIR). Visual function tests were repeated with the chosen filters, both in the presence and absence of glare from the fluorescent source. Patients trialled the two filters for two weeks each, in random order. Following the trial of each filter, a telephone questionnaire was completed. Results: VA and contrast sensitivity were unaffected by the coloured filters but reduced through the neutral density filters (p < 0.01). VA and contrast sensitivity were reduced by similar amounts, following the introduction of the glare source, both in the presence and absence of filters (p < 0.001). Colour vision error scores were increased following the introduction of a neutral density filter (from 177.6 ± 60.2 to 251.9 ± 115.2) and still further through coloured filters (275.1 ± 50.8; p < 0.001). In the absence of any filter, colour vision error scores increased by 29.1 ± 55.60 units in the presence of glare (F2,107 = 3.9, p = 0.02); however, there was little change in colour vision error scores, in the presence of glare, with either the neutral density or coloured filters. Questionnaires indicated that patients tended to gain more benefit from the coloured filters. Conclusions: Coloured filters had minimal impact on VA and contrast sensitivity in patients with age-related macular degeneration; however, they caused a small reduction in objective colour vision, although this was not registered subjectively by patients. Patients indicated that they received more benefit from the coloured filters compared with neutral density filters. © 2013 The Authors © 2013 Optometrists Association Australia.
Resumo:
Visual search impairment can occur following stroke. The utility of optimal spectral filters on visual search in stroke patients has not been considered to date. The present study measured the effect of optimal spectral filters on visual search response time and accuracy, using a task requiring serial processing. A stroke and control cohort undertook the task three times: (i) using an optimally selected spectral filter; (ii) the subjects were randomly assigned to two groups with group 1 using an optimal filter for two weeks, whereas group 2 used a grey filter for two weeks; (iii) the groups were crossed over with group 1 using a grey filter for a further two weeks and group 2 given an optimal filter, before undertaking the task for the final time. Initial use of an optimal spectral filter improved visual search response time but not error scores in the stroke cohort. Prolonged use of neither an optimal nor a grey filter improved response time or reduced error scores. In fact, response times increased with the filter, regardless of its type, for stroke and control subjects; this outcome may be due to contrast reduction or a reflection of task design, given that significant practice effects were noted. © 2013 a Pion publication.
Resumo:
Purpose - The aim of the study was to determine the effect of optimal spectral filters on reading performance following stroke. Methods - Seventeen stroke subjects, aged 43-85, were considered with an age-matched Control Group (n = 17). Subjects undertook the Wilkins Rate of Reading Test on three occasions: (i) using an optimally selected spectral filter; (ii) subjects were randomly assigned to two groups: Group 1 used an optimal filter, whereas Group 2 used a grey filter, for two-weeks. The grey filter had similar photopic reflectance to the optimal filters, intended as a surrogate for a placebo; (iii) the groups were crossed over with Group 1 using a grey filter and Group 2 given an optimal filter, for two weeks, before undertaking the task once more. An increase in reading speed of >5% was considered clinically relevant. Results - Initial use of a spectral filter in the stroke cohort, increased reading speed by ~8%, almost halving error scores, findings not replicated in controls. Prolonged use of an optimal spectral filter increased reading speed by >9% for stroke subjects; errors more than halved. When the same subjects switched to using a grey filter, reading speed reduced by ~4%. A second group of stroke subjects used a grey filter first; reading speed decreased by ~3% but increased by ~4% with an optimal filter, with error scores almost halving. Conclusions - The present study has shown that spectral filters can immediately improve reading speed and accuracy following stroke, whereas prolonged use does not increase these benefits significantly. © 2013 Spanish General Council of Optometry.
Resumo:
An inverse problem is considered where the structure of multiple sound-soft planar obstacles is to be determined given the direction of the incoming acoustic field and knowledge of the corresponding total field on a curve located outside the obstacles. A local uniqueness result is given for this inverse problem suggesting that the reconstruction can be achieved by a single incident wave. A numerical procedure based on the concept of the topological derivative of an associated cost functional is used to produce images of the obstacles. No a priori assumption about the number of obstacles present is needed. Numerical results are included showing that accurate reconstructions can be obtained and that the proposed method is capable of finding both the shapes and the number of obstacles with one or a few incident waves.
Resumo:
We consider a Cauchy problem for the Laplace equation in a bounded region containing a cut, where the region is formed by removing a sufficiently smooth arc (the cut) from a bounded simply connected domain D. The aim is to reconstruct the solution on the cut from the values of the solution and its normal derivative on the boundary of the domain D. We propose an alternating iterative method which involves solving direct mixed problems for the Laplace operator in the same region. These mixed problems have either a Dirichlet or a Neumann boundary condition imposed on the cut and are solved by a potential approach. Each of these mixed problems is reduced to a system of integral equations of the first kind with logarithmic and hypersingular kernels and at most a square root singularity in the densities at the endpoints of the cut. The full discretization of the direct problems is realized by a trigonometric quadrature method which has super-algebraic convergence. The numerical examples presented illustrate the feasibility of the proposed method.