991 resultados para PH measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Temperature-sensitive poly(N-isopropylacrylamide) (PNIPA) nanohydrogels were synthesized by nanoemulsion polymerization in water-in-oil systems. Several cross-linking degrees and the incorporation of acrylic acid as comonomer at different concentrations were tested to produce nanohydrogels with a wide range of properties. The physicochemical properties of PNIPA nanohydrogels, and their relationship with the swelling-collapse behaviour, were studied to evaluate the suitability of PNIPA nanoparticles as smart delivery systems (for active packaging). The swelling-collapse transition was analyzed by the change in the optical properties of PNIPA nanohydrogels using ultraviolet-visible spectroscopy. The thermodynamic parameters associated with the nanohydrogels collapse were calculated using a mathematical approach based on the van't Hoff analysis, assuming a two-state equilibrium (swollen to collapsed). A mathematical model is proposed to predict both the thermally induced collapse, and the collapse induced by the simultaneous action of two factors (temperature and pH, or temperature and organic solvent concentration). Finally, van't Hoff analysis was compared with differential scanning calorimetry. The results obtained allow us to solve the problem of determining the molecular weight of the structural repeating unit in cross-linked NIPA polymers, which, as we show, can be estimated from the ratio of the molar heat capacity (obtained from the van't Hoff analysis) to the specific heat capacity (obtained from calorimetric measurements).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fish muscle as food is to be seen as highly perishable. In unfrozen fish, freshness is considered the most important quality attribute. It is well known that there are several biochemical changes that can affect dramatically the texture of fish muscle. Immediately after death the fish texture is soft and elastic. In connection with rigor mortis the fish texture changes markedly. It becomes harder during rigor and after its resolution it becomes softer. This softness increases due to proteolysis during further storage at refrigerated conditions. Texture is a very important indicator for evaluating the quality of fish. Barroso et al. (1997) have recently reviewed mechanical methods in use for texture measurements on fresh fish. Further reviews on texture measurement performed on fish muscle were recently published underlining the importance of texture as quality attribute (Hyldig et al 2001, Coppes et al. 2002). The position along the fish can influence the results and was investigated by several authors (Sigurgis-ladottir et. al. 1999). Different methods have been compared for their ability to differentiate between recently killed salmon and salmon stored on ice for up to 24 days (Veland et al. 1999).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

12 samples (6 original samples and 6 diluted samples) were analysed by 14 WEFTA laboratories for their pH values in an inter-laboratory comparison exercise. As a result it can be stated that the majority of participating laboratories could determine the pH values very exactly. The pH values obtained are ranging only little around the calculated mean (less than 0.1 pH unit). It could also be demonstrated that the participating institutes could analyse both, pH values in fishery products and aqueous salt solutions. However, also in this exercise a number of outliers and deviating values have been detected. Therefore it is of utmost importance to calibrate the pH electrodes in regular intervals and to maintain them carefully. Intra-laboratory comparison measurements are recommended to detect weak points.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After the evaluation of 48 samples consisting of hand and machine-peeled sand shrimps it can be stated that there was no significant difference in quality between both. The quality of the sand shrimps was evaluated by sensorially performed paired comparison as well as by estimating the microbial load and the volatile amines (MMA, DMA, TMA). Additionally, the colour characteristics were measured instrumentally. To characterise the influence of the technological regime measurements of pH and of the salt content were performed. The quality of sand shrimp is further influenced by technological steps as freezing, cooking procedure and preservatives used. From the hygienic point of view the machine-peeling was without any objections. The microbial load was small and below the limit set by EC. Measurement of volatile amines was not suited to make visible difference created be the various peeling methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, it has been observed that a liquid film spreading on a sample surface will significantly distort atomic force microscopy (AFM) measurements. In order to elaborate on the effect, we establish an equation governing the deformation of liquid film under its interaction with the AFM tip and substrate. A key issue is the critical liquid bump height y(0c) at which the liquid film jumps to contact the AFM tip. It is found that there are three distinct regimes in the variation of y(0c) with film thickness H, depending on Hamaker constants of tip, sample and liquid. Noticeably, there is a characteristic thickness H* physically defining what a thin film is; namely, once the film thickness H is the same order as H* , the effect of film thickness should be taken into account. The value of H* is dependent on Hamaker constants and liquid surface tension as well as tip radius.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we measured 14 horizontal velocity profiles along the vertical direction of a rectangular microchannel with aspect ratio alpha = h/w = 0.35 (h is the height of the channel and w is the width of the channel) using microPIV at Re = 1.8 and 3.6. The experimental velocity profiles are compared with the full 3D theoretical solution, and also with a Poiseuille parabolic profile. It is shown that the experimental velocity profiles in the horizontal and vertical planes are in agreement with the theoretical profiles, except for the planes close to the wall. The discrepancies between the experimental data and 3D theoretical results in the center vertical plane are less than 3.6%. But the deviations between experimental data and Poiseuille's results approaches 5%. It indicates that 2D Poiseuille profile is no longer a perfect theoretical approximation since a = 0.35. The experiments also reveal that, very near the hydrophilic wall (z = 0.5-1 mu m), the measured velocities are significantly larger than the theoretical velocity based on the no-slip assumption. A proper discussion on some physical effects influencing the near wall velocity measurement is given.