995 resultados para Measurement points


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two-dimensional numerical simulation model of interface states in scanning capacitance microscopy (SCM) measurements of p-n junctions is presented-In the model, amphoteric interface states with two transition energies in the Si band gap are represented as fixed charges to account for their behavior in SCM measurements. The interface states are shown to cause a stretch-out-and a parallel shift of the capacitance-voltage characteristics in the depletion. and neutral regions of p-n junctions, respectively. This explains the discrepancy between - the SCM measurement and simulation near p-n junctions, and thus modeling interface states is crucial for SCM dopant profiling of p-n junctions. (C) 2002 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

If a dental patient develops chest pain it must always be managed promptly and properly, i.e., the practitioner immediately stops the procedure and, being aware of the patients's medical history, questions the patient regarding the nature of the pain to help determine the likely diagnosis. It will most likely be a manifestation of coronary artery disease (synonymous with ischaemic heart disease), i.e., angina pectoris or acute myocardial infarction, most usually the former. Angina will usually resolve with proper intervention whereas up to about one-half of myocardial infarction cases will develop cardiac arrest, mostly in the first few hours, and this will be fatal in up to two-thirds of cases. As health care professions, dental practitioners have an inherent duty of care to be able to initiate appropriate care if such a medical emergency occurs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We determine the number of F-q-rational points of a class of Artin-Schreier curves by using recent results concerning evaluations of some exponential sums. In particular, we determine infinitely many new examples of maximal and minimal plane curves in the context of the Hasse-Weil bound. (C) 2002 Elsevier Science (USA).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper an approach to extreme event control in wastewater treatment plant operation by use of automatic supervisory control is discussed. The framework presented is based on the fact that different operational conditions manifest themselves as clusters in a multivariate measurement space. These clusters are identified and linked to specific and corresponding events by use of principal component analysis and fuzzy c-means clustering. A reduced system model is assigned to each type of extreme event and used to calculate appropriate local controller set points. In earlier work we have shown that this approach is applicable to wastewater treatment control using look-up tables to determine current set points. In this work we focus on the automatic determination of appropriate set points by use of steady state and dynamic predictions. The performance of a relatively simple steady-state supervisory controller is compared with that of a model predictive supervisory controller. Also, a look-up table approach is included in the comparison, as it provides a simple and robust alternative to the steady-state and model predictive controllers, The methodology is illustrated in a simulation study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The increasing use of performance measurement by government means that child protection services are under pressure to demonstrate effectiveness in protecting children from harm and efficiency in the use of public funds to help children and families. From a policy perspective, the way performance measurement is conceptualised and implemented can have major consequences for service delivery. This paper examines key issues raised in the literature about performance measurement, the context for its introduction in child protection, how the concepts of effectiveness and efficiency are dealt with, how client outcomes are defined, and assumptions about 'good performance'. An overview of performance measurement in child protection in Australia is provided. The paper argues that a critical approach to performance measurement in child protection can contribute to improved service delivery to clients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The association of sustained cerebral edema with poor neurological outcome following hypoxia-ischaemia in the neonate suggests that measurement of cerebral edema may allow early prediction of outcome in these infants. Direct measurements of cerebral impedance have been widely used in animal studies to monitor cerebral edema, but such invasive measurements are not possible in the human neonate. This study investigated the ability of noninvasive cerebral impedance measurements to detect cerebral edema following hypoxia-ischaemia. One-day-old piglets were anaesthetized, intubated and ventilated. Hypoxia was induced by reducing the inspired oxygen concentration to 4-6% O-2. Noninvasive cerebral bioimpedance was measured using gel electrodes attached to the scalp. Cerebral bioimpedance was also measured directly by insertion of two silver-silver chloride electrodes subdurally. Noninvasive and invasive measurements were made before, during and after hypoxia. Whole body impedance was measured to assess overall fluid movements. Intracranial pressure was measured continuously via a catheter inserted subdurally, as an index of cerebral edema. There was good agreement between noninvasive and invasive measurements of cerebral impedance although externally obtained responses were attenuated. Noninvasive measurements were also well correlated with intracranial pressure. Whole body impedance changes did not account for increases in noninvasively measured cerebral impedance. Results suggest that noninvasive cerebral impedance measurements do reflect intracranial events, and are able to detect cerebral edema following hypoxia-ischaemia in the neonate. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An acceleration compensated transducer was developed to enable the direct measurement of skin friction in hypervelocity impulse facilities. The gauge incorporated a measurement and acceleration element that employed direct shear of a piezoelectric ceramic. The design integrated techniques to maximize rise time and shear response while minimizing the affects of acceleration, pressure, heat transfer, and electrical interference. The arrangement resulted in a transducer natural frequency near 40 kHz. The transducer was calibrated for shear and acceleration in separate bench tests and was calibrated for pressure within an impulse facility. Uncertainty analyses identified only small experimental errors in the shear and acceleration calibration techniques. Although significant errors were revealed in the method of pressure calibration, total skin-friction measurement errors as low as +/-7-12% were established. The transducer was successfully utilized in a shock tunnel, and sample measurements are presented for flow conditions that simulate a flight Mach number near 8.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A spectrum of anti-inflammatory properties, evidence of anti-infective action against Pseudomonas aeruginosa at sub-inhibitory concentrations and positive clinical experience in patients with diffuse panbronchiolitis, a disease with features in common with cystic fibrosis (CF), has prompted research to evaluate the role of macrolide therapy in patients with CF. Newer macrolides such as azithromycin have the advantage of improved tolerability and a prolonged intracellular half-life requiring an infrequent dosing regimen. Results from initial studies suggest a benefit from several months of macrolide therapy in patients with CF. An improvement in lung function was initially shown in a small open study in children, while maintenance of lung function compared with placebo, reduced acute respiratory exacerbations, and reduced systemic markers of inflammation were demonstrated in a randomized, placebo-controlled study of macrolide therapy in adult patients with CF. Additional controlled studies are required to determine optimal drug, dosage, and duration of therapy, and long-term adverse effects of prolonged therapy with macrolides in patients with CF. The potential, with long-term use, to induce resistance against other bacteria colonizing the upper respiratory tract e.g. pneumococci has not been explored. Measurement of cytokines and inflammatory mediators from the sputum of patients with CF is technically difficult and does not correlate with disease activity. There is a need for easily measurable, reproducible and clinically meaningful end-points for evaluation of new therapies in CF. The choice of appropriate outcome measures, apart from lung function, to monitor disease activity needs careful consideration in clinical trials determining the efficacy of macrolides in patients with CF. Evidence-based recommendations for the use of macrolides in the treatment of CF are not expected for some years although macrolides are already being prescribed for long-term use in some centers. There is a need for further research into mechanisms of anti-inflammatory action of macrolides in the lungs of patients with CF and whether or not such therapy may be beneficial in the long term. Copyright 2002 Adis International

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improved HPLC method has been established for the measurement of harderoporphyrin (HP) in the harderian gland of rats and mice. Groups of female Wistar rats were given a single oral dose of sodium arsenite at 0, 0.5 or 5.0 mg As(III)/kg body weight, or a slurry of arsenic-contaminated soil at equivalent dose rates and the animals were sacrificed 96 h after dosing. A group of C57BL/6J female mice were chronically exposed to drinking water containing 500 mug As(V)/I of sodium arsenate ad libitum for over 2 years. Porphyrins were measured in the harderian glands of rats and mice. Our results suggest that HP and the alteration of the porphyrin profile in the harderian glands of rodents is a highly sensitive biomarker for both single sub-lethal and chronic arsenic exposure. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The isotope composition of Ph is difficult to determine accurately due to the lack of a stable normalisation ratio. Double and triple-spike addition techniques provide one solution and presently yield the most accurate measurements. A number of recent studies have claimed that improved accuracy and precision could also be achieved by multi-collector ICP-MS (MC-ICP-MS) Pb-isotope analysis using the addition of Tl of known isotope composition to Pb samples. In this paper, we verify whether the known isotope composition of Tl can be used for correction of mass discrimination of Pb with an extensive dataset for the NIST standard SRM 981, comparison of MC-ICP-MS with TIMS data, and comparison with three isochrons from different geological environments. When all our NIST SRM 981 data are normalised with one constant Tl-205/Tl-203 of 2.38869, the following averages and reproducibilities were obtained: Pb-207/Pb-206=0.91461+/-18; Pb-208/Ph-206 = 2.1674+/-7; and (PbPh)-Pb-206-Ph-204 = 16.941+/-6. These two sigma standard deviations of the mean correspond to 149, 330, and 374 ppm, respectively. Accuracies relative to triple-spike values are 149, 157, and 52 ppm, respectively, and thus well within uncertainties. The largest component of the uncertainties stems from the Ph data alone and is not caused by differential mass discrimination behaviour of Ph and Tl. In routine operation, variation of sample introduction memory and production of isobaric molecular interferences in the spectrometer's collision cell currently appear to be the ultimate limitation to better reproducibility. Comparative study of five different datasets from actual samples (bullets, international rock standards, carbonates, metamorphic minerals, and sulphide minerals) demonstrates that in most cases geological scatter of the sample exceeds the achieved analytical reproducibility. We observe good agreement between TIMS and MC-ICP-MS data for international rock standards but find that such comparison does not constitute the ultimate. test for the validity of the MC-ICP-MS technique. Two attempted isochrons resulted in geological scatter (in one case small) in excess of analytical reproducibility. However, in one case (leached Great Dyke sulphides) we obtained a true isochron (MSWD = 0.63) age of 2578.3 +/- 0.9 Ma, which is identical to and more precise than a recently published U-Pb zircon age (2579 3 Ma) for a Great Dyke websterite [Earth Planet. Sci. Lett. 180 (2000) 1-12]. Reproducibility of this age by means of an isochron we regard as a robust test of accuracy over a wide dynamic range. We show that reliable and accurate Pb-isotope data can be obtained by careful operation of second-generation MC-ICP magnetic sector mass spectrometers. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. Health promotion policy frameworks, recent theorizing, and research all emphasize understanding and mobilizing environmental influences to change particular health-related behaviors in specific settings. The workplace is a key environmental setting. The Checklist of Health Promotion Environments at Worksites (CHEW) was designed as a direct observation instrument to assess characteristics of worksite environments that are known to influence health-related behaviors. Methods. The CHEW is a 112-item checklist of workplace environment features hypothesized to be associated, both positively and negatively, with physical activity, healthy eating, alcohol consumption, and smoking. The three environmental domains assessed are (1) physical characteristics of the worksite, (2) features of the information environment, and (3) characteristics of the immediate neighborhood around the workplace. The conceptual rationale and development studies for the CHEW are described, and data from observational studies of 20 worksites are reported. Results. The data on CHEW-derived environmental attributes showed generally good reliability and identified meaningful sets of variables that plausibly may influence health-related behaviors. With the exception of one information environment attribute, intraclass correlation coefficients ranged from 0.80 to 1.00. Descriptive statistics on selected physical and information environment characteristics indicated that vending machines, showers, bulletin boards, and signs prohibiting smoking were common across worksites. Bicycle racks, visible stairways, and signs related to alcohol consumption, nutrition, and health. promotion were relatively uncommon. Conclusions. These findings illustrate the types of data on environmental attributes that can be derived, their relevance for program planning, and how they can characterize variability across worksites. The CHEW is a promising observational measure that has the potential to assess environmental influences on health behaviors and to evaluate workplace health promotion programs.