999 resultados para MAGNETIC-SECTOR INSTRUMENTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

After the landmark studies reporting changes in the cerebral metabolic rate of glucose (CMRGlc ) in excess of those in oxygen (CMRO2 ) during physiological stimulation, several studies have examined the fate of the extra carbon taken up by the brain, reporting a wide range of changes in brain lactate from 20% to 250%. The present study reports functional magnetic resonance spectroscopy measurements at 7 Tesla using the enhanced sensitivity to study a small cohort (n = 6). Small increases in lactate (19% ± 4%, P < 0.05) and glutamate (4% ± 1%, P < 0.001) were seen within the first 2 min of activation. With the exception of glucose (12% ± 5%, P < 0.001), no other metabolite concentration changes beyond experimental error were significantly observed. Therefore, the present study confirms that lactate and glutamate changes during physiological stimulation are small (i.e. below 20%) and shows that the increased sensitivity allows reproduction of previous results with fewer subjects. In addition, the initial rate of glutamate and lactate concentration increases implies an increase in CMRO2 that is slightly below that of CMRGlc during the first 1-2 min of activation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Uncomplicated chronic rachialgia is a highly prevalent complaint, and one for which therapeutic results are contradictory. The aim of the present study is to evaluate the effectiveness and safety of treatment with auriculopressure, in the primary healthcare sector, carried out by trained healthcare professionals via a 30-hour course. METHODS/DESIGN The design consists of a multi-centre randomized controlled trial, with placebo, with two parallel groups, and including an economic evaluation. Patients with chronic uncomplicated rachialgia, whose GP is considering referral for auriculopressure sensory stimulation, are eligible for inclusion. Sampling will be by consecutive selection, and randomised allocation to one of the two study arms will be determined using a centralised method, following a 1:1 plan (true auriculopressure; placebo auriculopressure). The implants (true and placebo) will be replaced once weekly, and the treatment will have a duration of 8 weeks. The primary outcome measure will be the change in pain intensity, measured on a visual analogue scale (VAS) of 100 mm, at 9 weeks after beginning the treatment. A follow up study will be performed at 6 months after beginning treatment. An assessment will also be made of the changes measured in the Spanish version of the McGill Pain Questionnaire, of the changes in the Lattinen test, and of the changes in quality of life (SF-12). Also planned is an analysis of cost-effectiveness and also, if necessary, a cost-benefit analysis. DISCUSSION This study will contribute to developing evidence on the use of auriculotherapy using Semen vaccariae [wang bu liu xing] for the treatment of uncomplicated chronic rachialgia. TRIAL REGISTRATION Current Controlled Trials ISRCTN01897462.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: An accurate, noninvasive technique for the diagnosis of coronary disease would be an important advance. We investigated the accuracy of coronary magnetic resonance angiography among patients with suspected coronary disease in a prospective, multicenter study. METHODS: Coronary magnetic resonance angiography was performed during free breathing in 109 patients before elective x-ray coronary angiography, and the results of the two diagnostic procedures were compared. RESULTS: A total of 636 of 759 proximal and middle segments of coronary arteries (84 percent) were interpretable on magnetic resonance angiography. In these segments, 78 (83 percent) of 94 clinically significant lesions (those with a > or = 50 percent reduction in diameter on x-ray angiography) were also detected by magnetic resonance angiography. Overall, coronary magnetic resonance angiography had an accuracy of 72 percent (95 percent confidence interval, 63 to 81 percent) in diagnosing coronary artery disease. The sensitivity, specificity, and accuracy for patients with disease of the left main coronary artery or three-vessel disease were 100 percent (95 percent confidence interval, 97 to 100 percent), 85 percent (95 percent confidence interval, 78 to 92 percent), and 87 percent (95 percent confidence interval, 81 to 93 percent), respectively. The negative predictive values for any coronary artery disease and for left main artery or three-vessel disease were 81 percent (95 percent confidence interval, 73 to 89 percent) and 100 percent (95 percent confidence interval, 97 to 100 percent), respectively. CONCLUSIONS: Among patients referred for their first x-ray coronary angiogram, three-dimensional coronary magnetic resonance angiography allows for the accurate detection of coronary artery disease of the proximal and middle segments. This noninvasive approach reliably identifies (or rules out) left main coronary artery or three-vessel disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper discusses maintenance challenges of organisations with a huge number of devices and proposes the use of probabilistic models to assist monitoring and maintenance planning. The proposal assumes connectivity of instruments to report relevant features for monitoring. Also, the existence of enough historical registers with diagnosed breakdowns is required to make probabilistic models reliable and useful for predictive maintenance strategies based on them. Regular Markov models based on estimated failure and repair rates are proposed to calculate the availability of the instruments and Dynamic Bayesian Networks are proposed to model cause-effect relationships to trigger predictive maintenance services based on the influence between observed features and previously documented diagnostics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article discusses the construction of tri-sector partnerships in three projects conducted in Brazil in different fields of intervention of public policy (access to water, basic education and performance of boards of rights of children and adolescents). Collaborative articulations involving the players from three sectors (the State, civil society and the market) are practices that are little studied in the Brazilian and even in the international context, as tri-sector partnerships are rare, despite the proliferation of lines of discourse in support of alliances between governments and civil society or between companies and NGOs in the management of public policy. As a research strategy, this study resorted to cooperative inquiry, a method that involves breaking down the boundaries between the subjects and the objects of the analysis. Besides working toward a better understanding of the challenges of building tri-sector partnerships in the Brazilian context, the article also tries to show the relevance to public policy studies of investigative methods based on the subjects studied, as a means of developing an understanding of the practices, lines of discourse and dilemmas linked to social action in social programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MRI tractography is the mapping of neural fiber pathways based on diffusion MRI of tissue diffusion anisotropy. Tractography based on diffusion tensor imaging (DTI) cannot directly image multiple fiber orientations within a single voxel. To address this limitation, diffusion spectrum MRI (DSI) and related methods were developed to image complex distributions of intravoxel fiber orientation. Here we demonstrate that tractography based on DSI has the capacity to image crossing fibers in neural tissue. DSI was performed in formalin-fixed brains of adult macaque and in the brains of healthy human subjects. Fiber tract solutions were constructed by a streamline procedure, following directions of maximum diffusion at every point, and analyzed in an interactive visualization environment (TrackVis). We report that DSI tractography accurately shows the known anatomic fiber crossings in optic chiasm, centrum semiovale, and brainstem; fiber intersections in gray matter, including cerebellar folia and the caudate nucleus; and radial fiber architecture in cerebral cortex. In contrast, none of these examples of fiber crossing and complex structure was identified by DTI analysis of the same data sets. These findings indicate that DSI tractography is able to image crossing fibers in neural tissue, an essential step toward non-invasive imaging of connectional neuroanatomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT We propose a model to explain how contract terms are selected in the presence of a form of economic power: contract power. The orange juice sector is used to illustrate an analysis that demonstrates the effects of contract power on the economic organization of the sector. We define contract power as the ability to exploit contractual gaps or failures of contractual provisions, which are strategically left incomplete. Empirical evidence from content analysis of antitrust documents supports the logic of contract power in the orange juice sector in three forms: avoiding changes to payment methods from weight to solid contents (quality); using information asymmetries to manipulate indexes that calculate the formula of orange prices; and deliberately harvesting oranges late in order to dehydrate the fruit, which consequently reduces weight and price. The paper contributes to understanding the selection of contract terms and the debate about how antitrust offices can deal with this issue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT This paper addresses the changes in university-industry relations in Brazil regarding innovation activities. It is based on a survey of articles published in major national journals or presented at the most relevant Brazilian and regional conferences, between 1980 and 2012. The year 1980 was chosen due to the creation of the Technological Innovation Offices (NITs), which was the first government initiative to encourage knowledge transfer from universities to companies; the second was the Innovation Act of 2004. Our assumption was that after the Act the number of academic papers on this subject would increase, bringing new ideas and propositions of models to enhance this relationship. The methodology employed a qualitative, exploratory approach, using bibliographical research and a bibliometric analysis of 247 papers. Literature review of international studies shows the discussion of problems and suggestions for improvements, while in Brazil there is still a debate on whether this collaboration should occur, and if this is a legitimate role for the university. Despite the numerical growth, the content analysis showed few papers on new configurations and procedures for partnership management. We conclude that university-industry relations are not a regular and totally accepted process in Brazilian public universities, which reflect an ideological bias against cooperation with firms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SAP R/3 és un software estàndard de gestió empresarial que engloba tots els processos iactivitats d’una companyia i permet el disseny de l’aplicació a les necessitats de l’empresa.Diferents avantatges, com ara disposar d’una base de dades única, han fet escollir aquestsistema a una empresa del sector metal•lúrgic com a eina de gestió:Aquest projecte té com a objecte la implantació de dos dels mòduls que inclou el sistemaSAP R/3, concretament el mòdul SD (Sales and Distribution), amb el qual es controlen lesvendes de l’empresa, i el mòdul MM (Material Management), mòdul amb el qual es controlatot el que fa referència als materials, la gestió d’estocs i tota la gestió de compres del’empresa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Esophageal temperature is the gold standard for in-the-field temperature monitoring in hypothermic victims with cardiac arrest. For practical reasons, some mountain rescue teams use homemade esophageal thermometers to measure esophageal temperature; these consist of nonmedical inside/outside temperature monitoring instruments that have been modified to allow for esophageal insertion. We planned a study to determine the accuracy of such thermometers. METHODS: Two of the same model of digital cabled indoor/outdoor thermometer were modified and tested in comparison with a reference thermometer. The thermometers were tested in a water bath at different temperatures between 10°C and 35.2°C. Three hundred measurements were taken with each thermometer. RESULTS: Our experimental study showed that both homemade thermometers provided a good correlation and a clinically acceptable agreement in comparison with the reference thermometer. Measurements were within 0.5°C in comparison with the reference thermometer 97.5% of the time. CONCLUSIONS: The homemade thermometers performed well in vitro, in comparison with a reference thermometer. However, because these devices in their original form are not designed for clinical use, their use should be restricted to situations when the use of a conventional esophageal thermometer is impossible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We sought to investigate the relationship between infarct and dyssynchrony post- myocardial infarct (MI), in a porcine model. Mechanical dyssynchrony post-MI is associated with left ventricular (LV) remodeling and increased mortality. METHODS: Cine, gadolinium-contrast, and tagged cardiovascular magnetic resonance (CMR) were performed pre-MI, 9 ± 2 days (early post-MI), and 33 ± 10 days (late post-MI) post-MI in 6 pigs to characterize cardiac morphology, location and extent of MI, and regional mechanics. LV mechanics were assessed by circumferential strain (eC). Electro-anatomic mapping (EAM) was performed within 24 hrs of CMR and prior to sacrifice. RESULTS: Mean infarct size was 21 ± 4% of LV volume with evidence of post-MI remodeling. Global eC significantly decreased post MI (-27 ± 1.6% vs. -18 ± 2.5% (early) and -17 ± 2.7% (late), p < 0.0001) with no significant change in peri-MI and MI segments between early and late time-points. Time to peak strain (TTP) was significantly longer in MI, compared to normal and peri-MI segments, both early (440 ± 40 ms vs. 329 ± 40 ms and 332 ± 36 ms, respectively; p = 0.0002) and late post-MI (442 ± 63 ms vs. 321 ± 40 ms and 355 ± 61 ms, respectively; p = 0.012). The standard deviation of TTP in 16 segments (SD16) significantly increased post-MI: 28 ± 7 ms to 50 ± 10 ms (early, p = 0.012) to 54 ± 19 ms (late, p = 0.004), with no change between early and late post-MI time-points (p = 0.56). TTP was not related to reduction of segmental contractility. EAM revealed late electrical activation and greatly diminished conduction velocity in the infarct (5.7 ± 2.4 cm/s), when compared to peri-infarct (18.7 ± 10.3 cm/s) and remote myocardium (39 ± 20.5 cm/s). CONCLUSIONS: Mechanical dyssynchrony occurs early after MI and is the result of delayed electrical and mechanical activation in the infarct.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary magnetic resonance angiography (MRA) is a powerful noninvasive technique with high soft-tissue contrast for the visualization of the coronary anatomy without X-ray exposure. Due to the small dimensions and tortuous nature of the coronary arteries, a high spatial resolution and sufficient volumetric coverage have to be obtained. However, this necessitates scanning times that are typically much longer than one cardiac cycle. By collecting image data during multiple RR intervals, one can successfully acquire coronary MR angiograms. However, constant cardiac contraction and relaxation, as well as respiratory motion, adversely affect image quality. Therefore, sophisticated motion-compensation strategies are needed. Furthermore, a high contrast between the coronary arteries and the surrounding tissue is mandatory. In the present article, challenges and solutions of coronary imaging are discussed, and results obtained in both healthy and diseased states are reviewed. This includes preliminary data obtained with state-of-the-art techniques such as steady-state free precession (SSFP), whole-heart imaging, intravascular contrast agents, coronary vessel wall imaging, and high-field imaging. Simultaneously, the utility of electron beam computed tomography (EBCT) and multidetector computed tomography (MDCT) for the visualization of the coronary arteries is discussed.