966 resultados para Light-Curing of Dental Adhesives
Resumo:
The aim of this study was to investigate the reporting completeness of systematic review (SR) abstracts in leading dental specialty journals. Electronic and supplementary hand searching were undertaken to identify SRs published in seven dental specialty journals and in the Cochrane Database of Systematic Reviews. Abstract reporting completeness was evaluated using a checklist derived from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (prisma) guidelines. Descriptive statistics followed by univariate and multivariate analyses were conducted. Two-hundred and eighteen SR abstracts were identified. Reporting of interventions (94%), objectives (96%), data sources (81%), eligibility criteria (77%), and conclusions (97%) was adequate in the majority of reviews. However, inadequate reporting of participants (18%), results (42%), effect size (14%), level of significance (60%), and trial registration (100%) was commonplace. The mean overall reporting score was 79.1% (95% CI, 77.6-80.6). Only journal of publication was a significant predictor of overall reporting, with inferior results for all journals relative to Cochrane reviews, with scores ranging from -4.3% (95% CI, -8.74 to 0.08) to -35.6% (95% CI, -42.0 to -24.3) for the International Journal of Prosthodontics and the British Journal of Oral and Maxillofacial Surgery, respectively. Improved reporting of dental SR abstracts is needed and should be encouraged, as these abstracts may underpin influential clinical decisions.
Resumo:
OBJECTIVES This article reviews the present literature on the issues encountered while coping with children with autistic spectrum disorder from the dental perspective. The autistic patient profile and external factors affecting the oral health status of this patient population are discussed upon the existing body of evidence. MATERIAL AND METHODS The MEDLINE database was searched using the terms 'Autistic Disorder', 'Behaviour Control/methods', 'Child', 'Dental care for disabled', 'Education', 'Oral Health', and 'Pediatric Dentistry' to locate related articles published up to January 2013. RESULTS Most of the relevant studies indicate poor oral hygiene whereas they are inconclusive regarding the caries incidence in autistic individuals. Undergraduate dental education appears to determine the competence of dental professionals to treat developmentally disabled children and account partly for compromised access to dental care. Dental management of an autistic child requires in-depth understanding of the background of the autism and available behavioural guidance theories. The dental professional should be flexible to modify the treatment approach according to the individual patient needs.
Resumo:
OBJECTIVE The aim of our investigation was to review the implementation of a comprehensive tobacco dependence education (TDE) curriculum at the Medi School of Dental Hygiene (MSDH), Bern, Switzerland, 2001-2008. METHODS In 2001, new forms to record patients' tobacco use history and willingness to quit were created for all the MSDH patients. In 2002, a new theoretically based tobacco dependence treatment protocol was implemented into the MSDH curriculum. Students received instruction on how to provide brief tobacco use dependence interventions as well as maintain detailed records of patient tobacco use and cessation interventions for every smoker at all dental hygiene visits. RESULTS In 2002, 17 lecture hours were added to the following subjects: pathology, periodontology, preventive dentistry, pharmacology and psychology. During the same time period, 2213 patients (56.9% women) have visited the MSDH. Smoking status was recorded in 85.7% of all the patients (30.2% smokers). Brief tobacco use interventions were recorded in 36.8% of all smokers while 7.6% of these have reported to quit smoking. CONCLUSIONS Overall, the new TDE curriculum was successfully implemented and accepted by the MSDH faculty. Applications in the clinical practice, however, may still be improved to better identify smokers and increase initial and follow-up interventions potentially leading to higher quit rates.
Resumo:
Citation only
Resumo:
Problem: Dental radiographs generally display one or more findings/diagnoses, and are linked to a unique set of patient demographics, medical history and other findings not represented by the image. However, this information is not associated with radiographs in any type of meta format, and images are not searchable based on any clinical criteria (1,2). The purpose of this pilot study is to create an online, searchable data repository of dental radiographs to be used for patient care, teaching and research. [See PDF for complete abstract]
Resumo:
OBJECTIVES: To detect the influence of blood contamination (BC) on the bond strength (BS) of a self-etching bonding system (SES) to enamel and dentine. METHODS: 25 human molars were longitudinally sectioned on the mesio-distal axis in order to obtain 50 specimens, which were embedded in acrylic resin. At first, the specimens were ground to expose a flat surface of enamel, and a bond strength test was performed. Afterwards, the samples were ground again in order to obtain a flat surface of dentine. Ten groups (total: n=100) were assigned according to substrate (enamel and dentine), step in the bonding sequence when contamination occurred (before the acidic primer and after the bonding resin), and contamination treatment (dry or rinse and dry procedure). Fresh human blood was introduced either before or after SES application (Clearfil SE Bond) and treated with air drying, or by rinsing and drying following application. Composite resin (Filtek Z-250,3M ESPE) was applied as inverted, truncated cured cones that were debonded in tension. RESULTS: The mean tensile BS values (MPa) for enamel/dentine were 19.4/23.0 and 17.1/10.0 for rinse-and-dry treatment (contamination before and after SES, respectively); while the measurements for the dry treatment, 16.2/23.3 and 0.0/0.0 contamination before and after SES, respectively. CONCLUSIONS: It was determined that blood contamination impaired adhesion to enamel and dentine when it occurred after bond light curing. Among the tested contamination treatments, the rinse-and-dry treatment produced the highest bond strength with BC after SES application, but it was not sufficient to recover the BS in the contamination-free group.
Resumo:
Background: High and ultra-high dilutions of various starting materials, e.g. copper sulfate, Hypericum perforatum and sulfur, showed significant differences in ultraviolet light (UV) transmission from controls and amongst different dilution levels [1,2]. Verum and placebo globules of Aconitum napellus 30c or calcium carbonate/quercus e cortice 6x from the same packs as used in previous clinical trials and dissolved in water could be distinguished by UV spectroscopy [3]. However, it was unclear whether the differences in UV absorbance originated from specific characteristics of the starting materials, from differences in the production of verum and placebo globules, and/or other unknown interference factors. Aims: The aim of this study was to investigate whether globules produced with high and ultra-high dilutions (6x, 12x, 30c, 200c, 200CF (centesimal discontinuous fluxion), 10,000CF) of various starting materials (Aconitum napellus, Atropa belladonna, phosphorus, sulfur, Apis mellifica, quartz) could be distinguished by UV spectroscopy. Methodology: The globules were specially produced for this study by Spagyros AG (Gümligen, Switzerland) and differed only in the starting materials of the dilutions (but not in the batch of globules or ethanol used). Globules were dissolved in water at 10 mg/ml, in quadruplicates, approximately 22 h prior to the measurements. Absorbance of the samples in the UV range (from 190 to 340 nm) was measured in a randomized order with a Shimadzu double beam UV-1800 spectrophotometer equipped with an auto sampler. Samples of each starting material were prepared and measured on 5 independent days. The daily variations of the spectrophotometer as well as the drift during the measurements were corrected for. The average absorbance from 200 to 340 nm was compared among various starting materials within equal dilution levels using a Kruskal-Wallis test. Results: Statistically significant differences were found among 30c (Figure 1), 200c and 200CF dilutions of the various starting materials. No differences were found among 6x, 12x and 10,000CF dilutions. Conclusions: Globules prepared from high dilutions of various starting materials may show significantly different UV absorbance when dissolved in water. References [1] Wolf U, Wolf M, Heusser P, Thurneysen A, Baumgartner S. Homeopathic preparations of quartz, sulfur and copper sulfate assessed by UV-spectroscopy. Evid Based Complement Alternat Med. 2011;2011:692798. [2] Klein SD, Sandig A, Baumgartner S, Wolf U. Differences in median ultraviolet light transmissions of serial homeopathic dilutions of copper sulfate, Hypericum perforatum, and sulfur. Evid Based Complement Alternat Med. 2013;2013:370609. [3] Klein SD, Wolf U. Investigating homeopathic verum and placebo globules with ultraviolet spectroscopy. Forsch Komplementmed. 2013, accepted.
Resumo:
The etiology of feline dental resorptive lesions is unknown, but some evidence suggests that interactions between components of the periodontium may be initiating factors in the development of these lesions. In the present study, 22 clinically normal teeth were harvested from 7 cats. The teeth and periodontium were radiographed and examined histologically. In addition, 14 of the 22 teeth were examined histometrically. Two teeth were histologically normal with an open apical foramen and two were normal with a closed apical foramen. Histological evidence of periodontal ligament degeneration without cementum resorption was observed in 8 teeth, and varying degrees of cementum resorption were observed in 10 teeth. Mandibular molar and premolar teeth had distal drift, and mandibular canine teeth had mesial drift. Alterations in the periodontal ligament may represent a preclinical stage of dental resorption.
Resumo:
Purpose: To investigate the bond strength to dentin of two recent resin-ceramic materials for computer-aided design/computer-aided manufacturing (CAD/CAM) after 24 hours and after six months storage. Methods and Materials: Ninety cylinders were milled out of Lava Ultimate (3M ESPE) and 90 cylinders out of VITA ENAMIC (VITA Zahnfabrik) (dimension of cylinders: ∅=3.6 mm, h=2 mm). All Lava Ultimate cylinders were sandblasted (aluminium oxide, grain size: 27 μm) and cleaned with ethanol, whereas all VITA ENAMIC cylinders were acid-etched (5% hydrofluoric acid) and cleaned with water-spray. According to the three groups of cements used, the cylinders (n=30/resin-ceramic material) were further pretreated with 1) Scotchbond Universal for RelyX Ultimate (3M ESPE), 2) CLEARFIL Ceramic Primer for PANAVIA F2.0 (Kuraray), or 3) no further pretreatment for Ketac Cem Plus (3M ESPE). The cylinders were then bonded to ground human dentin specimens with 1) Scotchbond Universal and RelyX Ultimate (light-cured), 2) ED PRIMER II and PANAVIA F2.0 (light-cured), or 3) no adhesive system; Ketac Cem Plus (self-cured). Shear bond strength (SBS) was measured after 24 hours for 15 specimens/group and after six months (37°C, 100% humidity) for the other 15 specimens/group. SBS-values were statistically analysed with nonparametric ANOVA followed by exact Wilcoxon rank sum tests (α=0.05). Results: SBS of the two resin-ceramic materials and the three cements after 24 hours and after six months storage are shown in Figure 1. The statistical analysis showed that the duration of storage had a significant effect on SBS of Lava Ultimate for all three cements but had no significant effect on SBS of VITA ENAMIC. For Lava Ultimate SBS-values were (MPa; medians after 24 hours/six months): 13.5/22.5 (p=0.04) for RelyX Ultimate, 11.4/5.8 (p=0.0006) for PANAVIA F2.0, and 0.34/0.09 (p=0.04) for Ketac Cem Plus (Fig. 1). For VITA ENAMIC SBS-values were (MPa; medians after 24 hours/six months): 16.0/21.2 (p=0.10) for RelyX Ultimate, 11.4/14.4 (p=0.06) for PANAVIA F2.0, and 0.43/0.41 (p=0.32) for Ketac Cem Plus (Fig. 1). After 24 hours, there was no significant difference in SBS between Lava Ultimate and VITA ENAMIC for all three cements (p≥0.37). After six months, there was no significant difference in SBS between Lava Ultimate and VITA ENAMIC for RelyX Ultimate and Ketac Cem Plus (p≥0.07) whereas for PANAVIA F2.0, SBS was significantly lower for Lava Ultimate than for VITA ENAMIC (p<0.0001). Conclusion: SBS of Lava Ultimate was more affected by six months storage and by the cement used than was VITA ENAMIC.
Resumo:
INTRODUCTION The aim of this study was to determine the reproducibility and accuracy of linear measurements on 2 types of dental models derived from cone-beam computed tomography (CBCT) scans: CBCT images, and Anatomodels (InVivoDental, San Jose, Calif); these were compared with digital models generated from dental impressions (Digimodels; Orthoproof, Nieuwegein, The Netherlands). The Digimodels were used as the reference standard. METHODS The 3 types of digital models were made from 10 subjects. Four examiners repeated 37 linear tooth and arch measurements 10 times. Paired t tests and the intraclass correlation coefficient were performed to determine the reproducibility and accuracy of the measurements. RESULTS The CBCT images showed significantly smaller intraclass correlation coefficient values and larger duplicate measurement errors compared with the corresponding values for Digimodels and Anatomodels. The average difference between measurements on CBCT images and Digimodels ranged from -0.4 to 1.65 mm, with limits of agreement values up to 1.3 mm for crown-width measurements. The average difference between Anatomodels and Digimodels ranged from -0.42 to 0.84 mm with limits of agreement values up to 1.65 mm. CONCLUSIONS Statistically significant differences between measurements on Digimodels and Anatomodels, and between Digimodels and CBCT images, were found. Although the mean differences might be clinically acceptable, the random errors were relatively large compared with corresponding measurements reported in the literature for both Anatomodels and CBCT images, and might be clinically important. Therefore, with the CBCT settings used in this study, measurements made directly on CBCT images and Anatomodels are not as accurate as measurements on Digimodels.
Resumo:
BACKGROUND Quantitative light intensity analysis of the strut core by optical coherence tomography (OCT) may enable assessment of changes in the light reflectivity of the bioresorbable polymeric scaffold from polymer to provisional matrix and connective tissues, with full disappearance and integration of the scaffold into the vessel wall. The aim of this report was to describe the methodology and to apply it to serial human OCT images post procedure and at 6, 12, 24 and 36 months in the ABSORB cohort B trial. METHODS AND RESULTS In serial frequency-domain OCT pullbacks, corresponding struts at different time points were identified by 3-dimensional foldout view. The peak and median values of light intensity were measured in the strut core by dedicated software. A total of 303 corresponding struts were serially analyzed at 3 time points. In the sequential analysis, peak light intensity increased gradually in the first 24 months after implantation and reached a plateau (relative difference with respect to baseline [%Dif]: 61.4% at 12 months, 115.0% at 24 months, 110.7% at 36 months), while the median intensity kept increasing at 36 months (%Dif: 14.3% at 12 months, 75.0% at 24 months, 93.1% at 36 months). CONCLUSIONS Quantitative light intensity analysis by OCT was capable of detecting subtle changes in the bioresorbable strut appearance over time, and could be used to monitor the bioresorption and integration process of polylactide struts.
Resumo:
The currently proposed space debris remediation measures include the active removal of large objects and “just in time” collision avoidance by deviating the objects using, e.g., ground-based lasers. Both techniques require precise knowledge of the attitude state and state changes of the target objects. In the former case, to devise methods to grapple the target by a tug spacecraft, in the latter, to precisely propagate the orbits of potential collision partners as disturbing forces like air drag and solar radiation pressure depend on the attitude of the objects. Non-resolving optical observations of the magnitude variations, so-called light curves, are a promising technique to determine rotation or tumbling rates and the orientations of the actual rotation axis of objects, as well as their temporal changes. The 1-meter telescope ZIMLAT of the Astronomical Institute of the University of Bern has been used to collect light curves of MEO and GEO objects for a considerable period of time. Recently, light curves of Low Earth Orbit (LEO) targets were acquired as well. We present different observation methods, including active tracking using a CCD subframe readout technique, and the use of a high-speed scientific CMOS camera. Technical challenges when tracking objects with poor orbit redictions, as well as different data reduction methods are addressed. Results from a survey of abandoned rocket upper stages in LEO, examples of abandoned payloads and observations of high area-to-mass ratio debris will be resented. Eventually, first results of the analysis of these light curves are provided.
Resumo:
The population of space debris increased drastically during the last years. Collisions involving massive objects may produce large number of fragments leading to significantly growth of the space debris population. An effective remediation measure in order to stabilize the population in LEO, is therefore the removal of large, massive space debris. To remove these objects, not only precise orbits, but also more detailed information about their attitude states will be required. One important property of an object targeted for removal is its spin period and spin axis orientation. If we observe a rotating object, the observer sees different surface areas of the object which leads to changes in the measured intensity. Rotating objects will produce periodic brightness vari ations with frequencies which are related to the spin periods. Photometric monitoring is the real tool for remote diagnostics of the satellite rotation around its center of mass. This information is also useful, for example, in case of contingency. Moreover, it is also important to take into account the orientation of non-spherical body (e.g. space debris) in the numerical integration of its motion when a close approach with the another spacecr aft is predicted. We introduce the two databases of light curves: the AIUB data base, which contains about a thousand light curves of LEO, MEO and high-altitude debris objects (including a few functional objects) obtained over more than seven years, and the data base of the Astronomical Observatory of Odessa University (Ukraine), which contains the results of more than 10 years of photometric monitoring of functioning satellites and large space debris objects in low Earth orbit. AIUB used its 1m ZIMLAT telescope for all light curves. For tracking low-orbit satellites, the Astronomical Observatory of Odessa used the KT-50 telescope, which has an alt-azimuth mount and allows tracking objects moving at a high angular velocity. The diameter of the KT-50 main mirror is 0.5 m, and the focal length is 3 m. The Odessa's Atlas of light curves includes almost 5,5 thousand light curves for ~500 correlated objects from a time period of 2005-2014. The processing of light curves and the determination of the rotation period in the inertial frame is challenging. Extracted frequencies and reconstructed phases for some interesting targets, e.g. GLONASS satellites, for which also SLR data were available for confirmation, will be presented. The rotation of the Envisat satellite after its sudden failure will be analyzed. The deceleration of its rotation rate within 3 years is studied together with the attempt to determine the orientation of the rotation axis.
Resumo:
We present a power-scalable approach for yellow laser-light generation based on standard Ytterbium (Yb) doped fibers. To force the cavity to lase at 1154 nm, far above the gain-maximum, measures must be taken to fulfill lasing condition and to suppress competing amplified spontaneous emission (ASE) in the high-gain region. To prove the principle we built a fiber-laser cavity and a fiber-amplifier both at 1154 nm. In between cavity and amplifier we suppressed the ASE by 70 dB using a fiber Bragg grating (FBG) based filter. Finally we demonstrated efficient single pass frequency doubling to 577 nm with a periodically poled lithium niobate crystal (PPLN). With our linearly polarized 1154 nm master oscillator power fiber amplifier (MOFA) system we achieved slope efficiencies of more than 15 % inside the cavity and 24 % with the fiber-amplifier. The frequency doubling followed the predicted optimal efficiency achievable with a PPLN crystal. So far we generated 1.5 W at 1154nm and 90 mW at 577 nm. Our MOFA approach for generation of 1154 nm laser radiation is power-scalable by using multi-stage amplifiers and large mode-area fibers and is therefore very promising for building a high power yellow laser-light source of several tens of Watt.
Resumo:
INTRODUCTION Proangiogenic prolyl hydroxylase (PHD) inhibitors represent a novel approach to stimulate tissue regeneration. Diabetes mellitus involves the accumulation of advanced glycation end products (AGEs). Here we evaluated the impact of AGEs on the response of human pulp tissue to the PHD inhibitor L-mimosine (L-MIM) in monolayer cultures of dental pulp-derived cells (DPCs) and tooth slice organ cultures. METHODS In monolayer cultures, DPCs were incubated with L-MIM and AGEs. Viability was assessed based on formazan formation, live-dead staining, annexin V/propidium iodide, and trypan blue exclusion assay. Vascular endothelial growth factor (VEGF), interleukin (IL)-6, and IL-8 production was evaluated by quantitative polymerase chain reaction and immunoassays. Furthermore, expression levels of odontoblast markers were assessed, and alizarin red staining was performed. Tooth slice organ cultures were performed, and VEGF, IL-6, and IL8 levels in their supernatants were measured by immunoassays. Pulp tissue vitality and morphology were assessed by MTT assay and histology. RESULTS In monolayer cultures of DPCs, L-MIM at nontoxic concentrations increased the production of VEGF and IL-8 in the presence of AGEs. Stimulation with L-MIM decreased alkaline phosphatase levels and matrix mineralization also in the presence of AGEs, whereas no significant changes in dentin matrix protein 1 and dentin sialophosphoprotein expression were observed. In tooth slice organ cultures, L-MIM increased VEGF but not IL-6 and IL-8 production in the presence of AGEs. The pulp tissue was vital, and no signs of apoptosis or necrosis were observed. CONCLUSIONS Overall, in the presence of AGEs, L-MIM increases the proangiogenic capacity, but decreases alkaline phosphatase expression and matrix mineralization.