Temporal evolution of strut light intensity after implantation of bioresorbable polymeric intracoronary scaffolds in the ABSORB cohort B trial-an application of a new quantitative method based on optical coherence tomography.


Autoria(s): Nakatani, Shimpei; Onuma, Yoshinobu; Ishibashi, Yuki; Eggermont, Jeroen; Zhang, Yao-Jun; Campos, Carlos M; Cho, Yun Kyeong; Liu, Shengnan; Dijkstra, Jouke; Reiber, Johan H C; Perkins, Laura; Sheehy, Alexander; Veldhof, Susan; Rapoza, Richard; van Es, Gerrit-Anne; Garcia-Garcia, Hector M; van Geuns, Robert-Jan; Serruys, Patrick W; Windecker, Stephan
Data(s)

01/08/2014

Resumo

BACKGROUND Quantitative light intensity analysis of the strut core by optical coherence tomography (OCT) may enable assessment of changes in the light reflectivity of the bioresorbable polymeric scaffold from polymer to provisional matrix and connective tissues, with full disappearance and integration of the scaffold into the vessel wall. The aim of this report was to describe the methodology and to apply it to serial human OCT images post procedure and at 6, 12, 24 and 36 months in the ABSORB cohort B trial. METHODS AND RESULTS In serial frequency-domain OCT pullbacks, corresponding struts at different time points were identified by 3-dimensional foldout view. The peak and median values of light intensity were measured in the strut core by dedicated software. A total of 303 corresponding struts were serially analyzed at 3 time points. In the sequential analysis, peak light intensity increased gradually in the first 24 months after implantation and reached a plateau (relative difference with respect to baseline [%Dif]: 61.4% at 12 months, 115.0% at 24 months, 110.7% at 36 months), while the median intensity kept increasing at 36 months (%Dif: 14.3% at 12 months, 75.0% at 24 months, 93.1% at 36 months). CONCLUSIONS Quantitative light intensity analysis by OCT was capable of detecting subtle changes in the bioresorbable strut appearance over time, and could be used to monitor the bioresorption and integration process of polylactide struts.

Formato

application/pdf

Identificador

http://boris.unibe.ch/62120/1/_pdf.pdf

Nakatani, Shimpei; Onuma, Yoshinobu; Ishibashi, Yuki; Eggermont, Jeroen; Zhang, Yao-Jun; Campos, Carlos M; Cho, Yun Kyeong; Liu, Shengnan; Dijkstra, Jouke; Reiber, Johan H C; Perkins, Laura; Sheehy, Alexander; Veldhof, Susan; Rapoza, Richard; van Es, Gerrit-Anne; Garcia-Garcia, Hector M; van Geuns, Robert-Jan; Serruys, Patrick W; Windecker, Stephan (2014). Temporal evolution of strut light intensity after implantation of bioresorbable polymeric intracoronary scaffolds in the ABSORB cohort B trial-an application of a new quantitative method based on optical coherence tomography. Circulation journal, 78(8), pp. 1873-1881. Japanese Circulation Society 10.1253/circj.CJ-14-0143 <http://dx.doi.org/10.1253/circj.CJ-14-0143>

doi:10.7892/boris.62120

info:doi:10.1253/circj.CJ-14-0143

info:pmid:24942012

urn:issn:1346-9843

Idioma(s)

eng

Publicador

Japanese Circulation Society

Relação

http://boris.unibe.ch/62120/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Nakatani, Shimpei; Onuma, Yoshinobu; Ishibashi, Yuki; Eggermont, Jeroen; Zhang, Yao-Jun; Campos, Carlos M; Cho, Yun Kyeong; Liu, Shengnan; Dijkstra, Jouke; Reiber, Johan H C; Perkins, Laura; Sheehy, Alexander; Veldhof, Susan; Rapoza, Richard; van Es, Gerrit-Anne; Garcia-Garcia, Hector M; van Geuns, Robert-Jan; Serruys, Patrick W; Windecker, Stephan (2014). Temporal evolution of strut light intensity after implantation of bioresorbable polymeric intracoronary scaffolds in the ABSORB cohort B trial-an application of a new quantitative method based on optical coherence tomography. Circulation journal, 78(8), pp. 1873-1881. Japanese Circulation Society 10.1253/circj.CJ-14-0143 <http://dx.doi.org/10.1253/circj.CJ-14-0143>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed