951 resultados para LINBO3-FE-MN


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple and fast method for the determination of Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen by quadrupole inductively coupled plasma spectrometry (q-ICP-MS) is described. Prior to analysis, samples (200 mu L) were diluted 1:50 in a solution containing 0.01% v/v Triton (R) X-100 and 0.5% v/v nitric acid and directly analyzed by ICP-MS. The limits of detection of the method are 0.3, 0.03, 0.2, 0.04, 0.04, 0.03 and 0.03 mu g L-1 for Ca-44, Cu-63, Fe-57, Mg-24, Zn-64, Se-82 and Mn-55, respectively. For purposes of comparison and method validation, four ordinary bovine semen samples were directly analyzed by ICP-MS and by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GF AAS), with no statistical difference between the techniques at the 95% level when applying the t-test. Then, the proposed method was applied in the determinations of Ca, Cu, Fe, Mg, Mn, Se and Zn in collected samples of bovine semen from different breeds, which are used in reproduction programs and artificial insemination.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple and fast method for the determination of Ca, Cu, Fe, Mg, Mn, Se and Zn in bovine semen by quadrupole inductively coupled plasma spectrometry (q-ICP-MS) is described. Prior to analysis, samples (200 µL) were diluted 1:50 in a solution containing 0.01% v/v Triton® X-100 and 0.5% v/v nitric acid and directly analyzed by ICP-MS. The limits of detection of the method are 0.3, 0.03, 0.2, 0.04, 0.04, 0.03 and 0.03 µg L-1 for 44Ca, 63Cu, 57Fe, 24Mg, 64Zn, 82Se and 55Mn, respectively. For purposes of comparison and method validation, four ordinary bovine semen samples were directly analyzed by ICP-MS and by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GF AAS), with no statistical difference between the techniques at the 95% level when applying the t-test. Then, the proposed method was applied in the determinations of Ca, Cu, Fe, Mg, Mn, Se and Zn in collected samples of bovine semen from different breeds, which are used in reproduction programs and artificial insemination.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Four species of planktic foraminifera from core-tops spanning a depth transect on the Ontong Java Plateau were prepared for Mg/Ca analysis both with (Cd-cleaning) and without (Mg-cleaning) a reductive cleaning step. Reductive cleaning caused etching of foraminiferal calcite, focused on Mg-rich inner calcite, even on tests which had already been partially dissolved at the seafloor. Despite corrosion, there was no difference in Mg/Ca of Pulleniatina obliquiloculata between cleaning methods. Reductive cleaning decreased Mg/Ca by an average (all depths) of ~ 4% for Globigerinoides ruber white and ~ 10% for Neogloboquadrina dutertrei. Mg/Ca of Globigerinoides sacculifer (above the calcite saturation horizon only) was 5% lower after reductive cleaning. The decrease in Mg/Ca due to reductive cleaning appeared insensitive to preservation state for G. ruber, N. dutertrei and P. obliquiloculata. Mg/Ca of Cd-cleaned G. sacculifer appeared less sensitive to dissolution than that of Mg-cleaned. Mg-cleaning is adequate, but SEM and contaminants (Al/Ca, Fe/Ca and Mn/Ca) show that Cd-cleaning is more effective for porous species. A second aspect of the study addressed sample loss during cleaning. Lower yield after Cd-cleaning for G. ruber, G. sacculifer and N. dutertrei confirmed this to be the more aggressive method. Strongest correlations between yield and Delta[CO3^2-] in core-top samples were for Cd-cleaned G. ruber (r = 0.88, p = 0.020) and Cd-cleaned P. obliquiloculata (r = 0.68, p = 0.030). In a down-core record (WIND28K) correlation, r, between yield values > 30% and dissolution index, XDX, was -0.61 (p = 0.002). Where cleaning yield < 30% most Mg-cleaned Mg/Ca values were biased by dissolution.