954 resultados para I.3.8 [Computing Methodologies]: Computer Graphics-Applications


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a framework for statistical finite element analysis combining shape and material properties, and allowing performing statistical statements of biomechanical performance across a given population. In this paper, we focus on the design of orthopaedic implants that fit a maximum percentage of the target population, both in terms of geometry and biomechanical stability. CT scans of the bone under consideration are registered non-rigidly to obtain correspondences in position and intensity between them. A statistical model of shape and intensity (bone density) is computed by means of principal component analysis. Afterwards, finite element analysis (FEA) is performed to analyse the biomechanical performance of the bones. Realistic forces are applied on the bones and the resulting displacement and bone stress distribution are calculated. The mechanical behaviour of different PCA bone instances is compared.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reconstruction of patient-specific 3D bone surface from 2D calibrated fluoroscopic images and a point distribution model is discussed. We present a 2D/3D reconstruction scheme combining statistical extrapolation and regularized shape deformation with an iterative image-to-model correspondence establishing algorithm, and show its application to reconstruct the surface of proximal femur. The image-to-model correspondence is established using a non-rigid 2D point matching process, which iteratively uses a symmetric injective nearest-neighbor mapping operator and 2D thin-plate splines based deformation to find a fraction of best matched 2D point pairs between features detected from the fluoroscopic images and those extracted from the 3D model. The obtained 2D point pairs are then used to set up a set of 3D point pairs such that we turn a 2D/3D reconstruction problem to a 3D/3D one. We designed and conducted experiments on 11 cadaveric femurs to validate the present reconstruction scheme. An average mean reconstruction error of 1.2 mm was found when two fluoroscopic images were used for each bone. It decreased to 1.0 mm when three fluoroscopic images were used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To design and evaluate a novel computer-assisted, fluoroscopy-based planning and navigation system for minimally invasive ventral spondylodesis of thoracolumbar fractures. MATERIALS AND METHODS: Instruments and an image intensifier are tracked with the SurgiGATE navigation system (Praxim-Medivision). Two fluoroscopic images, one acquired from anterior-posterior (AP) direction and the other from lateral-medial (LM) direction, are used for the complete procedure of planning and navigation. Both of them are calibrated with a custom-made software to recover their projection geometry and to co-register them to a common patient reference coordinate system, which is established by attaching an opto-electronically trackable dynamic reference base (DRB) on the operated vertebra. A bi-planar landmark reconstruction method is used to acquire deep-seated anatomical landmarks such that an intraoperative planning of graft bed can be interactively done. Finally, surgical actions such as the placement of the stabilization devices and the formation of the graft bed using a custom-made chisel are visualized to the surgeon by superimposing virtual instrument representations onto the acquired images. The distance between the instrument tip and each wall of the planned graft bed are calculated on the fly and presented to the surgeon so that the surgeon could formalize the graft bed exactly according to his/her plan. RESULTS: Laboratory studies on phantom and on 27 plastic vertebras demonstrate the high precision of the proposed navigation system. Compared with CT-based measurement, a mean error of 1.0 mm with a standard deviation of 0.1 mm was found. CONCLUSIONS: The proposed computer assisted, fluoroscopy-based planning and navigation system promises to increase the accuracy and reliability of minimally invasive ventral spondylodesis of thoracolumbar fractures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Keratin 8 (KRT8) is one of the major intermediate filament proteins expressed in single-layered epithelia of the gastrointestinal tract. Transgenic mice over-expressing human KRT8 display pancreatic mononuclear infiltration, interstitial fibrosis and dysplasia of acinar cells resulting in exocrine pancreatic insufficiency. These experimental data are in accordance with a recent report describing an association between KRT8 variations and chronic pancreatitis. This prompted us to investigate KRT8 polymorphisms in patients with pancreatic disorders. The KRT8 Y54H and G62C polymorphisms were assessed in a cohort of patients with acute and chronic pancreatitis of various aetiologies or pancreatic cancer originating from Austria (n=16), the Czech Republic (n=90), Germany (n=1698), Great Britain (n=36), India (n=60), Italy (n=143), the Netherlands (n=128), Romania (n=3), Spain (n=133), and Switzerland (n=129). We also studied 4,234 control subjects from these countries and 1,492 control subjects originating from Benin, Cameroon, Ethiopia, Ecuador, and Turkey. Polymorphisms were analysed by melting curve analysis with fluorescence resonance energy transfer probes. The frequency of G62C did not differ between patients with acute or chronic pancreatitis, pancreatic adenocarcinoma and control individuals. The frequency of G62C varied in European populations from 0.4 to 3.8%, showing a northwest to southeast decline. The Y54H alteration was not detected in any of the 2,436 patients. Only 3/4,580 (0.07%) European, Turkish and Indian control subjects were heterozygous for Y54H in contrast to 34/951 (3.6%) control subjects of African descent. Our data suggest that the KRT8 alterations, Y54H and G62C, do not predispose patients to the development of pancreatitis or pancreatic cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-frequency respiratory impedance data measured noninvasively by the high-speed interrupter technique (HIT), particularly the first antiresonance frequency (f(ar,1)), is related to airway wall mechanics. The aim of this study was to evaluate the feasibility and repeatability of HIT in unsedated pre-term infants, and to compare values of f(ar,1) from 18 pre-term (post-conceptional age 32-37 weeks, weight 1,730-2,910 g) and 18 full-term infants (42-47 weeks, 3,920-5,340 g). Among the pre-term infants, there was good short-term repeatability of f(ar,1) within a single sleep epoch (mean (sd) coefficient of variance: 8 (1.7)%), but 95% limits of agreement for repeated measures of f(ar,1) after 3-8 h were relatively wide (-41 Hz; 37 Hz). f(ar,1) was significantly lower in pre-term infants (199 versus 257 Hz), indicating that wave propagation characteristics in pre-term airways are different from those of full-term infants. The present authors suggest that this is consistent with developmental differences in airway wall structure and compliance, including the influence of the surrounding tissue. Since flow limitation is determined by wave propagation velocity and airway cross-sectional area, it was hypothesised that the physical ability of the airways to carry large flows is fundamentally different in pre-term than in full-term infants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Increased levels of 8-isoprostane were found in various human lung diseases suggesting 8-isoprostane as a marker of pulmonary oxidative stress in vivo. The exact role in pediatric lung diseases has not been defined yet. The goal of this study was to clarify the role of 8-isoprostane in nasally exhaled breath condensate as possible marker of oxidative stress in children with different lung diseases. METHODS: Levels of 8-isoprostane were measured in nasally exhaled breath condensate of 29 cystic fibrosis patients, 19 children with a history of wheezing episodes, 8 infants with acute respiratory tract infection and 53 healthy subjects using a specific enzyme immunoassay. RESULTS: Levels of 8-isoprostane did neither discriminate between different disease groups nor correlate with lung function in cystic fibrosis patients. CONCLUSIONS: Levels of 8-isoprostane in nasally exhaled breath condensate do not reflect oxidative stress in children with different lung diseases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Computer assisted orthopaedic surgery (CAOS) technology has recently been introduced to overcome problems resulting from acetabular component malpositioning in total hip arthroplasty. Available navigation modules can conceptually be categorized as computer tomography (CT) based, fluoroscopy based, or image-free. The current study presents a comprehensive accuracy analysis on the computer assisted placement accuracy of acetabular cups. It combines analyses using mathematical approaches, in vitro testing environments, and an in vivo clinical trial. A hybrid navigation approach combining image-free with fluoroscopic technology was chosen as the best compromise to CT-based systems. It introduces pointer-based digitization for easily assessable points and bi-planar fluoroscopy for deep-seated landmarks. From the in vitro data maximum deviations were found to be 3.6 degrees for inclination and 3.8 degrees for anteversion relative to a pre-defined test position. The maximum difference between intraoperatively calculated cup inclination and anteversion with the postoperatively measured position was 4 degrees and 5 degrees, respectively. These data coincide with worst cases scenario predictions applying a statistical simulation model. The proper use of navigation technology can reduce variability of cup placement well within the surgical safe zone. Surgeons have to concentrate on a variety of error sources during the procedure, which may explain the reported strong learning curves for CAOS technologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper addresses the problem of estimating postoperative cup alignment from single standard X-ray radiograph with gonadal shielding. The widely used procedure of evaluation of cup orientation following total hip arthroplasty using single standard anteroposterior radiograph is known inaccurate, largely due to the wide variability in individual pelvic position relative to X-ray plate. 2D-3D image registration methods have been introduced to estimate the rigid transformation between a preoperative CT volume and postoperative radiograph(s) for an accurate estimation of the postoperative cup alignment relative to an anatomical reference extracted from the CT data. However, these methods require either multiple radiographs or a radiograph-specific calibration, both of which are not avaiable for most retrospective studies. Furthermore, these methods were only evaluated on X-ray radiograph(s) without gonadal shielding. In this paper, we propose to use a hybrid 2D-3D registration scheme combining an iterative landmark-to-ray registration with a 2D-3D intensity-based registration to estimate the rigid transfromation for a precise estimation of cup alignment. Quantitative and qualitative results evaluated on clinical and cadaveric datasets are given which indicate the validity of our approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Medial ankle joint pain with localized cartilage degeneration due to medial joint overload in varus malalignment of the hindfoot lends itself to treatment by lateral closing wedge supramalleolar osteotomy. METHODS: From 1998 to 2003, nine patients between the ages of 21 to 59 years were operated. The etiology of the malalignment and degeneration was posttraumatic in eight and childhood osteomyelitis in one. Preoperative and postoperative standing radiographs were analyzed to determine the correction of the deformity and the grade of degeneration. Function and pain were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale. The average followup was 56 (range 15 to 88) months. RESULTS: The average time to osseous union was 10 +/- 3.31 weeks. There were no operative or postoperative complications. The average AOFAS score improved from 48 +/- 16.0 preoperatively to 74 +/- 11.7 postoperatively (p<0.004). The average pain subscore improved from 16 +/- 8.8 to 30 +/- 7.1 (p<0.008). The average tibial-ankle surface angle improved from 6.9 +/- 3.8 degrees of varus preoperatively to 0.6 +/- 1.9 degrees of valgus postoperatively (p<0.004). In the sagittal plane, the tibial-lateral-surface angle remained unchanged. At the final followup, two patients showed progression of radiographic ankle arthrosis grades. In one patient, it rose from grade 0 to I. In the other patient it advanced from grade II to III, with subsequent ankle arthrodesis required 16 months after the index procedure. Seven patients returned to their previous work. CONCLUSIONS: Lateral supramalleolar closing wedge osteotomy was an easy and safe procedure, effectively correcting hindfoot malalignment, relieving pain, restoring function, and halting progression of the degeneration in the short-term to mid-term in seven of nine patients.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACT: INTRODUCTION: Low blood pressure, inadequate tissue oxygen delivery and mitochondrial dysfunction have all been implicated in the development of sepsis-induced organ failure. This study evaluated the effect on liver mitochondrial function of using norepinephrine to increase blood pressure in experimental sepsis. METHODS: Thirteen anaesthetized pigs received endotoxin (Escherichia coli lipopolysaccharide B0111:B4; 0.4 mug/kg per hour) and were subsequently randomly assigned to norepinephrine treatment or placebo for 10 hours. Norepinephrine dose was adjusted at 2-hour intervals to achieve 15 mmHg increases in mean arterial blood pressure up to 95 mmHg. Systemic (thermodilution) and hepatosplanchnic (ultrasound Doppler) blood flow were measured at each step. At the end of the experiment, hepatic mitochondrial oxygen consumption (high-resolution respirometry) and citrate synthase activity (spectrophotometry) were assessed. RESULTS: Mean arterial pressure (mmHg) increased only in norepinephrine-treated animals (from 73 [median; range 69 to 81] to 63 [60 to 68] in controls [P = 0.09] and from 83 [69 to 93] to 96 [86 to 108] in norepinephrine-treated animals [P = 0.019]). Cardiac index and systemic oxygen delivery (DO2) increased in both groups, but significantly more in the norepinephrine group (P < 0.03 for both). Cardiac index (ml/min per.kg) increased from 99 (range: 72 to 112) to 117 (110 to 232) in controls (P = 0.002), and from 107 (84 to 132) to 161 (147 to 340) in norepinephrine-treated animals (P = 0.001). DO2 (ml/min per.kg) increased from 13 (range: 11 to 15) to 16 (15 to 24) in controls (P = 0.028), and from 16 (12 to 19) to 29 (25 to 52) in norepinephrine-treated animals (P = 0.018). Systemic oxygen consumption (systemic VO2) increased in both groups (P < 0.05), whereas hepatosplanchnic flows, DO2 and VO2 remained stable. The hepatic lactate extraction ratio decreased in both groups (P = 0.05). Liver mitochondria complex I-dependent and II-dependent respiratory control ratios were increased in the norepinephrine group (complex I: 3.5 [range: 2.1 to 5.7] in controls versus 5.8 [4.8 to 6.4] in norepinephrine-treated animals [P = 0.015]; complex II: 3.1 [2.3 to 3.8] in controls versus 3.7 [3.3 to 4.6] in norepinephrine-treated animals [P = 0.09]). No differences were observed in citrate synthase activity. CONCLUSION: Norepinephrine treatment during endotoxaemia does not increase hepatosplanchnic flow, oxygen delivery or consumption, and does not improve the hepatic lactate extraction ratio. However, norepinephrine increases the liver mitochondria complex I-dependent and II-dependent respiratory control ratios. This effect was probably mediated by a direct effect of norepinephrine on liver cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: To investigate whether preemptive administered lornoxicam changes perioperative platelet function during thoracic surgery. METHODS: A total of 20 patients scheduled for elective thoracic surgery were randomly assigned to receive either lornoxicam (16 mg, i.v.; n = 10) or placebo (n = 10) preoperatively. All patients underwent treatment of solitary lung metastasis and denied any antiplatelet medication within the past 2 weeks. Blood samples were drawn via an arterial catheter directly into silicone-coated Vacutainer tubes containing 0.5 mL of 0.129 M buffered sodium citrate 3.8% before, 15 min, 4 h and 8 h after the study medication was administered. Platelet aggregation curves were obtained by whole blood electrical impedance aggregometry (Chrono Log). RESULTS: Platelet aggregation was significantly reduced 15 min, 4 h and 8 h after lornoxicam administration compared to placebo (P < 0.05) for collagen, adenosine diphosphate and arachidonic acid as trigger substances. Adenosine diphosphate-induced platelet aggregation decreased by 85% 15 min after lornoxicam administration, and remained impaired for 8 h. CONCLUSION: Platelet aggregation assays are impaired for at least 8 h after lornoxicam application. Therefore perioperative analgesia by use of lornoxicam should be carefully administered under consideration of subsequent platelet dysfunction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High flexural strength and stiffness can be achieved by forming a thin panel into a wave shape perpendicular to the bending direction. The use of corrugated shapes to gain flexural strength and stiffness is common in metal and reinforced plastic products. However, there is no commercial production of corrugated wood composite panels. This research focuses on the application of corrugated shapes to wood strand composite panels. Beam theory, classical plate theory and finite element models were used to analyze the bending behavior of corrugated panels. The most promising shallow corrugated panel configuration was identified based on structural performance and compatibility with construction practices. The corrugation profile selected has a wavelength equal to 8”, a channel depth equal to ¾”, a sidewall angle equal to 45 degrees and a panel thickness equal to 3/8”. 16”x16” panels were produced using random mats and 3-layer aligned mats with surface flakes parallel to the channels. Strong axis and weak axis bending tests were conducted. The test results indicate that flake orientation has little effect on the strong axis bending stiffness. The 3/8” thick random mat corrugated panels exhibit bending stiffness (400,000 lbs-in2/ft) and bending strength (3,000 in-lbs/ft) higher than 23/32” or 3/4” thick APA Rated Sturd-I-Floor with a 24” o.c. span rating. Shear and bearing test results show that the corrugated panel can withstand more than 50 psf of uniform load at 48” joist spacings. Molding trials on 16”x16” panels provided data for full size panel production. Full size 4’x8’ shallow corrugated panels were produced with only minor changes to the current oriented strandboard manufacturing process. Panel testing was done to simulate floor loading during construction, without a top underlayment layer, and during occupancy, with an underlayment over the panel to form a composite deck. Flexural tests were performed in single-span and two-span bending with line loads applied at mid-span. The average strong axis bending stiffness and bending strength of the full size corrugated panels (without the underlayment) were over 400,000 lbs-in2/ft and 3,000 in-lbs/ft, respectively. The composite deck system, which consisted of an OSB sheathing (15/32” thick) nailed-glued (using 3d ringshank nails and AFG-01 subfloor adhesive) to the corrugated subfloor achieved about 60% of the full composite stiffness resulting in about 3 times the bending stiffness of the corrugated subfloor (1,250,000 lbs-in2/ft). Based on the LRFD design criteria, the corrugated composite floor system can carry 40 psf of unfactored uniform loads, limited by the L/480 deflection limit state, at 48” joist spacings. Four 10-ft long composite T-beam specimens were built and tested for the composite action and the load sharing between a 24” wide corrugated deck system and the supporting I-joist. The average bending stiffness of the composite T-beam was 1.6 times higher than the bending stiffness of the I-joist. A 8-ft x 12-ft mock up floor was built to evaluate construction procedures. The assembly of the composite floor system is relatively simple. The corrugated composite floor system might be able to offset the cheaper labor costs of the single-layer Sturd-IFloor through the material savings. However, no conclusive result can be drawn, in terms of the construction costs, at this point without an in depth cost analysis of the two systems. The shallow corrugated composite floor system might be a potential alternative to the Sturd-I-Floor in the near future because of the excellent flexural stiffness provided.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis, I study skin lesion detection and its applications to skin cancer diagnosis. A skin lesion detection algorithm is proposed. The proposed algorithm is based color information and threshold. For the proposed algorithm, several color spaces are studied and the detection results are compared. Experimental results show that YUV color space can achieve the best performance. Besides, I develop a distance histogram based threshold selection method and the method is proven to be better than other adaptive threshold selection methods for color detection. Besides the detection algorithms, I also investigate GPU speed-up techniques for skin lesion extraction and the results show that GPU has potential applications in speeding-up skin lesion extraction. Based on the skin lesion detection algorithms proposed, I developed a mobile-based skin cancer diagnosis application. In this application, the user with an iPhone installed with the proposed application can use the iPhone as a diagnosis tool to find the potential skin lesions in a persons' skin and compare the skin lesions detected by the iPhone with the skin lesions stored in a database in a remote server.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The toxicity of long-term immunosuppressive therapy has become a major concern in long-term follow-up of heart transplant recipients. In this respect the quality of renal function is undoubtedly linked to cyclosporin A (CsA) drug levels. In cardiac transplantation, specific CsA trough levels have historically been maintained between 250 and 350 micrograms/L in many centers without direct evidence for the necessity of such high levels while using triple-drug immunosuppression. This retrospective analysis compares the incidence of acute and chronic graft rejection as well as overall mortality between groups of patients with high (250 to 350 micrograms/L) and low (150 to 250 micrograms/L) specific CsA trough levels. A total of 332 patients who underwent heart transplantation between October 1985 and October 1992 with a minimum follow-up of 30 days were included in this study (46 women and 276 men; aged, 44 +/- 12 years; mean follow-up, 1,122 +/- 777 days). Standard triple-drug immunosuppression included first-year specific CsA target trough levels of 250 to 300 micrograms/L. Patients were grouped according to their average creatinine level in the first postoperative year (group I, < 130 mumol/L, n = 234; group II, > or = 130 mumol/L, n = 98). The overall 5-year survival excluding the early 30-day mortality was 92% (group I, 216/232) and 91% (group II, 89/98) with 75% of the mortality due to chronic rejection. The rate of rejection for the entire follow-up period was similar in both groups (first year: group I, 3.2 +/- 2.6 rejection/patient/year; group II, 3.6 +/- 2.7 rejection/patient/year; p = not significant).(ABSTRACT TRUNCATED AT 250 WORDS)