911 resultados para Horizontal loading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were conducted to investigate the influence of thermal parameters on the columnar to equiaxed transition during the horizontal unsteady-state directional solidification of Al-Si alloys. The parameters analyzed include the heat transfer coefficients, growth rates, cooling rates, temperature gradients and composition. A combined theoretical and experimental approach is developed to determine the solidification thermal variables considered. The increasing solute content in Al-Si alloys was not found to affect significantly the experimental position of the CET which occurred for cooling rates in the range between 0.35 and 0.64 K/s for any of three alloy compositions examined. A comparative analysis between the results of this work and those from the literature proposed to analyze the CET during upward vertical solidification of Al-Si alloys is reported and the results have shown that the end of the columnar region during horizontal directional solidification is abbreviated as a result of about six times higher thermal gradient than that verified during upward unidirectional solidification of alloys investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main purpose of this paper is to investigate both the columnar to equiaxed transition and primary dendritic arm spacings of Al-3wt.%Si alloy during the horizontal directional solidification. The transient heat transfer coefficient at the metal-mold interface is calculated based on comparisons between the experimental thermal profiles in castings and the simulations provided by a finite difference heat flow program. Simulated curve of the interfacial heat transfer coefficient was used in another numerical solidification model to determine theoretical values of tip growth rates, cooling rates and thermal gradients that are associated with both columnar to equiaxed transition and primary dendritic arm spacings. A good agreement was observed between the experimental values of these thermal variables and those numerically simulated for the alloy examined. A comparative analysis is carried out between the experimental data of this work and theoretical models from the literature that have been proposed to predict the primary dendritic spacings. In this context, this study may contribute to the understanding of how to manage solidification operational parameters aiming at designing the microstructure of Al-Si alloys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sistema de drenagem vertical e horizontal cuja finalidade é implantar os procedimentos de redistribuição da água na microbacia urbana com as caixas de contensão, captação e drenagem lenta vertical e horizontal, sustentável em ambiente urbano, para diminuir as enchentes, aumentar o reabastecimento do lençol freático com produção de água nas nascentes dos municípios e fundamentalmente melhorar a qualidade de vida da população que sofre com as enchentes. O sistema de drenagem vertical com filtro, com novos formatos de procedimentos e tubulações sustentáveis para a reversão de parte do escoamento superficial em infiltração da água, pode ser aplicado em qualquer ambiente urbano, tanto em áreas naturais, praças e bosques, quanto em áreas construídas e impermeabilizadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO:A melhor dose para o início do tratamento anticoagulante com varfarina vem sendo debatida nos últimos dez anos. Em nosso meio, não observamos nenhum estudo comparativo quanto a estas características.OBJETIVO:Comparar segurança e eficácia de dois esquemas de dosagem inicial de varfarina para tratamento anticoagulante.MÉTODOS:Foram estudados prospectivamente 110 pacientes de ambos os sexos, consecutivos, com indicação de anticoagulação por tromboembolismo venoso ou arterial. Durante os três primeiros dias de tratamento, estes pacientes receberam doses adequadas de heparina (RT - razão dos tempos - alvo entre 1,5 e 2,5) e 5 mg de varfarina, cuja dose foi reajustada a partir do quarto dia pelo Razão Normatizada Internacional - RNI (alvo entre 2 e 3). Esse grupo foi comparado com série histórica de 110 pacientes que receberam 10 mg nos dois primeiros dias, 5 mg a partir do terceiro dia, com ajuste posterior de dose baseado no RNI. Os desfechos foram: recorrência do tromboembolismo, sangramentos e tempo para alcançar níveis terapêuticos.RESULTADOS:A eficácia, a segurança e o tempo de internação foram similares entre os grupos. O grupo que recebeu 10 mg atingiu níveis terapêuticos mais precocemente (média de 4,5 dias × 5,8 dias), sendo as doses na alta menores e os níveis terapêuticos mais adequados na primeira visita de retorno.CONCLUSÃO:O esquema de dosagem de 10 mg proporcionou menor tempo para alcançar nível terapêutico, com menores doses de varfarina na alta e RNI mais adequado no retorno.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moderate and controlled loading environments support or enhance osteogenesis, and, consequently, a high degree of bone-to-implant contact can be acquired. This is because when osteoprogenitor cells are exposed to limited physical deformation, their differentiation into osteoblasts is enhanced. Then, some range of microstrain is considered advantageous for bone ingrowth and osseointegration. The primary stability has been considered one of the main clinical means of controlling micromotion between the implant and the forming interfacial tissue, which helps to establish the proper mechanical environment for osteogenesis. Based on the biological aspects of immediate loading (IL), the objective of this study is to present a clinical case of maxillary arch rehabilitation using immediate loading with implant-supported fixed restoration after bone graft. Ten dental implants were placed in the maxilla 6 months after the autogenous bone graft, removed from the mandible (bilateral oblique line and chin), followed by the installation of an immediate-load fixed cross-arch implant-supported restoration because primary stability was reached for 8 implants. In addition, instructions about masticatory function and how it is related to interfacial micromotion were addressed and emphasized to the patient. The reasons for the IL were further avoidance of an interim healing phase, a potential reduction in the number of clinical interventions for the patient, and aesthetic reasons. After monitoring the rehabilitation for 8 years, the authors can conclude that maxillary IL can be performed followed by a well-established treatment planning based on computed tomography, providing immediate esthetics and function to the patient even when autogenous bone graft was previously performed in the maxilla.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine the marginal adaptation of bulk-fill composites in class II MO cavities.Methods: Standardized class II MO cavities with bevelled enamel margins were prepared in 40 extracted human molars. The teeth were randomly assigned to one of the five experimental groups (n = 8). The teeth were restored with two horizontal increments of composite (4 mm and 2 mm thickness). The experimental groups were (1st/2nd increment): Gr. A - Venus Bulk-Fill/Venus Diamond; Gr. B - Tetric EvoCeram BulkFill/Tetric EvoCeram; Gr. C - Surefil SDR/Ceram-X; Gr. D - SonicFill; Gr. E - Ceram-X/Ceram-X (control). After finishing procedures, impressions were made using a polyvinyl siloxane and epoxy resin replicas were obtained. Thermo-mechanical stressing was carried out 24 h after the restorative procedure. All specimens were submitted to 240,000 occlusal loading and simultaneous 600 thermal cycles in water at 5 degrees C and 50 degrees C. After loading, a new set of epoxy resin replicas was obtained. Scanning electron microscopy was carried out at 200x magnification. Results for the marginal adaptation were expressed as percentages of continuity relative to the exposed interface and analyzed by ANOVA and Duncan post hoc test (p < 0.05).Results: In enamel, no significant differences were detected before and after thermo-mechanical loading between groups. In dentine, the worst results were observed in Gr. A.Conclusion: By applying simple layering techniques, bulk-fill materials do not allow better marginal adaptation than a standard composite. Clinical significance: A new class of resin-base composite (bulk-fill) was recently launched on the market. The bulk-fill composites exhibited adequate marginal adaptation and similar to the results of the standard composite. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Although the effect of symptomatic back pain on functional movement has been investigated, changes to spinal movement patterns in essentially pain-free people with a history of recurrent back pain are largely unreported. Reaching activities, important for everyday and occupational function, often present problems to such people, but have not been considered in this population. The purpose of this study was to compare the amplitude and timing of spinal and hip motions during two, seated reaching activities in people with and without a history of recurrent low back pain (RLBP).Methods: Spinal and hip motions during reaching downward and across the body, in both directions, were tracked using electromagnetic sensors. Analyses were conducted to explore the amplitudes, velocities and timings of 3D segmental movements and to compare controls with subjects with recurrent, but asymptomatic lumbar or lumbosacral pain.Findings: We detected significant differences in the amplitude and timing of movement in the lower thoracic region, with the RLBP group restricting movement and demonstrating compensatory increased motion at the hip. The lumbar region displayed no significant between-group differences. The order in which the spinal segments achieved peak velocity in cross-reaching was reversed in RLBP compared to controls, with lumbar motion leading in controls and lagging in RLBP.Interpretation: Subjects with a history of RLBP show a number of altered kinematic features during reaching activities which are not related to the presence or intensity of pain, but which suggest adaptive changes to movement control. (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)