995 resultados para Face Detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to identify macrophage-rich atherosclerotic plaque noninvasively by imaging the tissue uptake of long-circulating superparamagnetic nanoparticles with a positive contrast off-resonance imaging sequence (inversion recovery with ON-resonant water suppression [IRON]). BACKGROUND: The sudden rupture of macrophage-rich atherosclerotic plaques can trigger the formation of an occlusive thrombus in coronary vessels, resulting in acute myocardial infarction. Therefore, a noninvasive technique that can identify macrophage-rich plaques and thereby assist with risk stratification of patients with atherosclerosis would be of great potential clinical utility. METHODS: Experiments were conducted on a clinical 3-T magnetic resonance imaging (MRI) scanner in 7 heritable hyperlipidemic and 4 control rabbits. Monocrystalline iron-oxide nanoparticles (MION)-47 were administrated intravenously (2 doses of 250 mumol Fe/kg), and animals underwent serial IRON-MRI before injection of the nanoparticles and serially after 1, 3, and 6 days. RESULTS: After administration of MION-47, a striking signal enhancement was found in areas of plaque only in hyperlipidemic rabbits. The magnitude of enhancement on magnetic resonance images had a high correlation with the number of macrophages determined by histology (p < 0.001) and allowed for the detection of macrophage-rich plaque with high accuracy (area under the curve: 0.92, SE: 0.04, 95% confidence interval: 0.84 to 0.96, p < 0.001). No significant signal enhancement was measured in remote areas without plaque by histology and in control rabbits without atherosclerosis. CONCLUSIONS: Using IRON-MRI in conjunction with superparamagnetic nanoparticles is a promising approach for the noninvasive evaluation of macrophage-rich, vulnerable plaques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Failure to detect a species in an area where it is present is a major source of error in biological surveys. We assessed whether it is possible to optimize single-visit biological monitoring surveys of highly dynamic freshwater ecosystems by framing them a priori within a particular period of time. Alternatively, we also searched for the optimal number of visits and when they should be conducted. We developed single-species occupancy models to estimate the monthly probability of detection of pond-breeding amphibians during a four-year monitoring program. Our results revealed that detection probability was species-specific and changed among sampling visits within a breeding season and also among breeding seasons. Thereby, the optimization of biological surveys with minimal survey effort (a single visit) is not feasible as it proves impossible to select a priori an adequate sampling period that remains robust across years. Alternatively, a two-survey combination at the beginning of the sampling season yielded optimal results and constituted an acceptable compromise between sampling efficacy and survey effort. Our study provides evidence of the variability and uncertainty that likely affects the efficacy of monitoring surveys, highlighting the need of repeated sampling in both ecological studies and conservation management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sur la base d'une enquête quantitative et qualitative auprès des hauts fonctionnaires et membres du Gouvernement des cantons du Valais, du Jura et de Neuchâtel, le présent article vise à tester l'hypothèse selon laquelle les réformes inspirées des principes de la nouvelle gestion publique conduisent à la redéfinition des relations entre acteurs politiques et administratifs. Autrement dit, l'introduction des réformes permettrait de séparer plus strictement les activités stratégiques des activités opérationnelles. Or, les constats que nous tirons de nos investigations rendent compte d'une certaine « stabilité » des relations politico-administratives, au-delà des différences constatées dans les stratégies de modernisation menées dans les trois entités cantonales. Des facteurs institutionnels, mais également politiques, peuvent expliquer cette stabilité. De sorte que nos résultats remettent en question la faisabilité et la légitimité d'une séparation entre sphères politique et administrative à un niveau de gouvernance cantonal en Suisse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the predictive value of acid fast bacilii (AFB) smear for the diagnosis of Mycobacterium tuberculosis in respiratory specimens in a setting with a high prevalence of Aids and an unknown prevalence of nontuberculous mycobacteria (NTM), we retrospectively examined specimens cultured for mycobacteria between 1 September 1993 and 30 September 1994 and medical records of patients with positive culture in a General Hospital, Aids reference in Rio de Janeiro, Brazil. Seventy three per cent (1517/2077) of samples were respiratory specimens and mycobacteria were recovered from 20.6% (313/1517) of these. M. tuberculosis was identified in 94.2% (295/313) and NTM in 5.8% (18/313). The yield of positive AFB smear and of positive culture was 6.1% (93/1517) and 20.6% (313/1517), respectively. The positive predictive value (PPV) of AFB for M. tuberculosis was 98.4% in expectorated sputum and 96.4% in bronchoalveolar lavage. Forty four percent (130/295) of specimens with positive culture for M. tuberculosis and 66.7% (12/18) for NTM were from patients HIV positive. The conclusion was that in our study population, the PPV of AFB for M. tuberculosis in respiratory specimens was high and the prevalence of NTM was low despite the high prevalence of HIV positive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The RT-PCR technique for the detection of apple stem grooving virus (ASGV), apple stem pitting virus (ASPV), apple chlorotic leaf spot virus (ACLSV), apple mosaic virus (ApMV) and pear blister canker viroid (PBCV) was evaluated for health control of fruit plants from nurseries. The technique was evaluated in purified RNA and crude extracts and also in phloem collected in autumn and from young spring shoots. The results obtained for phytoplasma detection with ribosomal and non-ribosomal primers are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of morphoeic (or sclerosing) basal cell carcinoma (mBCC) of the face is associated with high rates of incomplete excision and recurrence. A principal risk factor for incomplete resection is the grade of surgeon. We did a prospective, randomised study of 40 consecutive patients with mBCC of the face. The extent of the tumour was assessed under standard conditions by consultant surgeons and compared with assessments by resident surgeons with the help of the Varioscope, a combination of microscope and loupe glasses with strong illumination and a maximal magnification of 7x. The data from a former retrospective study of all excisions of mBCC of the face during a five-year period at the hospital served as control. Residents with the support of the Varioscope achieved a rate of incomplete excisions similar to that of consultants under standard conditions. There was a significant reduction of the rate of incomplete resections by resident surgeons thanks to high magnification and good lighting (p=0.02). High magnification and good lighting were useful in learning how to recognise skin changes associated with mBCC of the face and achieving a low rate of incomplete excisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ultrastructure of the membrane attack complex (MAC) of complement had been described as representing a hollow cylinder of defined dimensions that is composed of the proteins C5b, C6, C7, C8, and C9. After the characteristic cylindrical structure was identified as polymerized C9 [poly(C9)], the question arose as to the ultrastructural identity and topology of the C9-polymerizing complex C5b-8. An electron microscopic analysis of isolated MAC revealed an asymmetry of individual complexes with respect to their length. Whereas the length of one boundary (+/- SEM) was always 16 +/- 1 nm, the length of the other varied between 16 and 32 nm. In contrast, poly(C9), formed spontaneously from isolated C9, had a uniform tubule length (+/- SEM) of 16 +/- 1 nm. On examination of MAC-phospholipid vesicle complexes, an elongated structure was detected that was closely associated with the poly(C9) tubule and that extended 16-18 nm beyond the torus of the tubule and 28-30 nm above the membrane surface. The width of this structure varied depending on its two-dimensional projection in the electron microscope. By using biotinyl C5b-6 in the formation of the MAC and avidin-coated colloidal gold particles for the ultrastructural analysis, this heretofore unrecognized subunit of the MAC could be identified as the tetramolecular C5b-8 complex. Identification also was achieved by using anti-C5 Fab-coated colloidal gold particles. A similar elongated structure of 25 nm length (above the surface of the membrane) was observed on single C5b-8-vesicle complexes. It is concluded that the C5b-8 complex, which catalyzes poly(C9) formation, constitutes a structure of discrete morphology that remains as such identifiable in the fully assembled MAC, in which it is closely associated with the poly(C9) tubule.