925 resultados para Borate buffer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Folate is shown to react with singlet-excited state of riboflavin in a diffusion controlled reaction and with triplet-excited state of riboflavin in a somewhat slower reaction with (3)k(q) = 4.8 x 10(8) L mol(-1) s(-1) in aqueous phosphate buffer at pH 7.4, ionic strength of 0.2 mol L(-1), and 25 degrees C. Singlet quenching is assigned as photo-induced reductive electron transfer from ground state folate to singlet-excited riboflavin, while triplet quenching is assigned as one-electron transfer rather than hydrogen atom transfer from folate to triplet-excited riboflavin, as the reaction quantum yield, phi = 0.32, is hardly influenced by solvent change from water to deuterium oxide, phi = 0.37. Cyclic voltammetry showed an irreversible two-electron anodic process for folate, E = 1.14 V versus NHE at a scan-rate of 50 mV s(-1), which appears to be kinetically controlled by the heterogeneous electron transfer from the substrates to the electrode. Main products of folate photooxidation sensitized by riboflavin were pterin-6-carboxylic acid and p-aminobenzoyl-L-glutamic acid as shown by liquid chromatographic ion-trap mass spectrometry (LC-IT-MS).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The possibility to compress analyte bands at the beginning of CE runs has many advantages. Analytes at low concentration can be analyzed with high signal-to-noise ratios by using the so-called sample stacking methods. Moreover, sample injections with very narrow initial band widths (small initial standard deviations) are sometimes useful, especially if high resolutions among the bands are required in the shortest run time. In the present work, a method of sample stacking is proposed and demonstrated. It is based on BGEs with high thermal sensitive pHs (high dpH/dT) and analytes with low dpK(a)/dT. High thermal sensitivity means that the working pK(a) of the BGE has a high dpK(a)/dT in modulus. For instance, Tris and Ethanolamine have dpH/dT = -0.028/degrees C and -0.029/degrees C, respectively, whereas carboxylic acids have low dpK(a)/dT values, i.e. in the -0.002/degrees C to+0.002/degrees C range. The action of cooling and heating sections along the capillary during the runs affects also the local viscosity, conductivity, and electric field strength. The effect of these variables on electrophoretic velocity and band compression is theoretically calculated using a simple model. Finally, this stacking method was demonstrated for amino acids derivatized with naphthalene-2,3-dicarboxaldehyde and fluorescamine using a temperature difference of 70 degrees C between two neighbor sections and Tris as separation buffer. In this case, the BGE has a high pH thermal coefficient whereas the carboxylic groups of the analytes have low pK(a) thermal coefficients. The application of these dynamic thermal gradients increased peak height by a factor of two (and decreased the standard deviations of peaks by a factor of two) of aspartic acid and glutamic acid derivatized with naphthalene-2,3-dicarboxaldehyde and serine derivatized with fluorescamine. The effect of thermal compression of bands was not observed when runs were accomplished using phosphate buffer at pH 7 (negative control). Phosphate has a low dpH/dT in this pH range, similar to the dK(a)/dT of analytes. It is shown that vertical bar dK(a)/dT-dpH/dT vertical bar >> 0 is one determinant factor to have significant stacking produced by dynamic thermal junctions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a previous work [M. Mandaji, et al., this issue] a sample stacking method was theoretically modeled and experimentally demonstrated for analytes with low dpK(a)/dT (analytes carrying carboxylic groups) and BGEs with high dpH/dT (high pH-temperature-coefficients). In that work, buffer pH was modulated with temperature, inducing electrophoretic mobility changes in the analytes. In the present work, the opposite conditions are studied and tested, i.e. analytes with high dpK(a)/dT and BGEs that exhibit low dpH/dT. It is well known that organic bases such as amines, imidazoles, and benzimidazoles exhibit high dpK(a)/dT. Temperature variations induce instantaneous changes on the basicity of these and other basic groups. Therefore, the electrophoretic velocity of some analytes changes abruptly when temperature variations are applied along the capillary. This is true only if BGE pH remains constant or if it changes in the opposite direction of pK(a) of the analyte. The presence of hot and cold sections along the capillary also affects local viscosity, conductivity, and electric field strength. The effect of these variables on electrophoretic velocity and band stacking efficacy was also taken into account in the theoretical model presented. Finally, this stacking method is demonstrated for lysine partially derivatized with naphthalene-2,3-dicarboxaldehyde. In this case, the amino group of the lateral chain was left underivatized and only the alpha amino group was derivatized. Therefore, the basicity of the lateral amino group, and consequently the electrophoretic mobility, was modulated with temperature while the pH of the buffer used remained unchanged.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential Pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials Of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 x 10(-7) mol L(-1) to 8.3 x 10(-7) mol L(-1) for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 x 10(-7) mol L-1 and 3.5 x 10(-8) mol L(-1), respectively. The proposed method Was Successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level). (C) 2008 Elsevier BY. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main idea of this research to solve the problem of inventory management for the paper industry SPM PVT limited. The aim of this research was to find a methodology by which the inventory of raw material could be kept at minimum level by means of buffer stock level.The main objective then lies in finding the minimum level of buffer stock according to daily consumption of raw material, finding the Economic Order Quantity (EOQ) reorders point and how much order will be placed in a year to control the shortage of raw material.In this project, we discuss continuous review model (Deterministic EOQ models) that includes the probabilistic demand directly in the formulation. According to the formula, we see the reorder point and the order up to model. The problem was tackled mathematically as well as simulation modeling was used where mathematically tractable solution was not possible.The simulation modeling was done by Awesim software for developing the simulation network. This simulation network has the ability to predict the buffer stock level based on variable consumption of raw material and lead-time. The data collection for this simulation network is taken from the industrial engineering personnel and the departmental studies of the concerned factory. At the end, we find the optimum level of order quantity, reorder point and order days.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The PM-brännaren (pellets burner) have on commission by the company been measured and evaluated in the combustion laboratory of SERC. The objective was to measure the perform-ance and the emissions of CO and NO for three different combustion powers and for start and stop conditions. The burner have been mounted in the Bionett-boiler from Ariterm and been adjusted by the company. The boiler has been connected to a buffer store that admits firing during long period with constant inlet temperature to the boiler. The measurements have been performed by operating the boiler on constant power until stationary conditions are reached. Thereafter the following two hours of operation have been evaluated. The results show that the burner fulfils the limit values for Blauer Engel labelling and the proposed limit values for Nordic Eco labelling. The measured concentration of NO is far below all organisations limit values for NOx. Concerning the start and stop emissions there are no demands from organisa-tions to compare with, but comparing with other boilers measured at SERC, the CO emissions from PM-brännaren is in the same order of magnitude.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work presented in this thesis concerns the dimensioning of an Energy Storage System (ESS) which will be used as an energy buffer for a grid-connected PV plant. This ESS should help managing the PV plant to inject electricity into the grid according to the requirements of the grid System Operator. It is desired to obtain a final production not below 1300kWh/kWp with a maximum ESS budget of 0.9€/Wp. The PV plant will be sited in Martinique Island and connected to the main grid. This grid is a small one where the perturbations due clouds in the PV generation are not negligible anymore. A software simulation tool, incorporating a model for the PV-plant production, the ESS and the required injection pattern of electricity into the grid has been developed in MS Excel. This tool has been used to optimize the relevant parameters defining the ESS so that the feed-in of electricity into the grid can be controlled to fulfill the conditions given by the System Operator. The inputs used for this simulation tool are, besides the conditions given by the System Operator on the allowed injection pattern, the production data from a similar PV-plant in a close-by location, and variables for defining the ESS. The PV production data used is from a site with similar climate and weather conditions as for the site on the Martinique Island and hence gives information on the short term insolation variations as well as expected annual electricity production. The ESS capacity and the injected electric energy will be the main figures to compare while doing an economic study of the whole plant. Hence, the Net Present Value, Benefit to Cost method and Pay-back period studies are carried on as dependent of the ESS capacity. The conclusion of this work is that it is possible to obtain the requested injection pattern by using an ESS. The design of the ESS can be made within an acceptable budget. The capacity of ESS to link with the PV system depends on the priorities of the final output characteristics, and it also depends on which economic parameter that is chosen as a priority.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate how electricallyheated houses can be converted to using wood pellet and solarheating. There are a large number of wood pellet stoves on themarket. Many stoves have a water jacket, which gives anopportunity to distribute the heat to domestic hot water and aradiator heating system. Three typical Swedish houses with electric resistanceheating have been studied. Fourteen different system conceptsusing wood pellet stoves and solar heating systems have beenevaluated. The systems and the houses have been simulated indetail using TRNSYS. The houses have been divided in up to 10different zones and heat transfer by air circulation throughdoorways and open doors have been simulated. The pellet stoveswere simulated using a recently developed TRNSYS component,which models the start- and stop phases, emissions and thedynamic behaviour of the stoves. The model also calculates theCO-emissions. Simulations were made with one stove without awater jacket and two stoves with different fractions of thegenerated heat distributed in the water circuit. Simulations show that the electricity savings using a pelletstove are greatly affected by the house plan, the systemchoice, if the internal doors are open or closed and thedesired level of comfort. Installing a stove with awater-jacket connected to a radiator system and a hot waterstorage has the advantage that heat can be transferred todomestic hot water and be distributed to other rooms. Suchsystems lead to greater electricity savings, especially inhouses having a traditional layout. It was found that not allrooms needed radiators and that it was more effective in mostcases t use a stove with a higher fraction of the heatdistributed by the water circuit. The economic investigation shows that installing a woodpellet stove without a water jacket gives the lowest totalenergy- and capital costs in the house with an open plan (fortoday's energy prices and the simulated comfort criteria). Inthe houses with a traditional layout a pellet stove givesslightly higher costs than the reference house having onlyelectrical resistance heating due to the fact that less heatingcan be replaced. The concepts including stoves with a waterjacket all give higher costs than the reference system, but theconcept closest to be economical is a system with a bufferstore, a stove with a high fraction of the heat distributed bythe water circuit, a new water radiator heating system and asolar collector. Losses from stoves can be divided into: flue gas lossesincluding leakage air flow when the stove is not in operation;losses during start and stop phases; and losses due to a highair factor. An increased efficiency of the stoves is importantboth from a private economical point of view, but also from theperspective that there can be a lack of bio fuel in the nearfuture also in Sweden. From this point of view it is alsoimportant to utilize as much solar heat as possible. Theutilization of solar heat is low in the simulated systems,depending on the lack of space for a large buffer store. The simulations have shown that the annual efficiency ismuch lower that the nominal efficiency at full power. Thesimulations have also shown that changing the control principlefor the stove can improve efficiency and reduce theCO-emissions. Today's most common control principle for stovesis the on/off control, which results in many starts and stopsand thereby high CO-emissions. A more advanced control varyingthe heating rate from maximum to minimum to keep a constantroom temperature reduces the number of starts and stops andthereby the emissions. Also the efficiency can be higher withsuch a control, and the room temperature will be kept at a moreconstant temperature providing a higher comfort.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Sweden, there are about 0.5 million single-family houses that are heated by electricity alone, and rising electricity costs force the conversion to other heating sources such as heat pumps and wood pellet heating systems. Pellet heating systems for single-family houses are currently a strongly growing market. Future lack of wood fuels is possible even in Sweden, and combining wood pellet heating with solar heating will help to save the bio-fuel resources. The objectives of this thesis are to investigate how the electrically heated single-family houses can be converted to pellet and solar heating systems, and how the annual efficiency and solar gains can be increased in such systems. The possible reduction of CO-emissions by combining pellet heating with solar heating has also been investigated. Systems with pellet stoves (both with and without a water jacket), pellet boilers and solar heating have been simulated. Different system concepts have been compared in order to investigate the most promising solutions. Modifications in system design and control strategies have been carried out in order to increase the system efficiency and the solar gains. Possibilities for increasing the solar gains have been limited to investigation of DHW-units for hot water production and the use of hot water for heating of dishwashers and washing machines via a heat exchanger instead of electricity (heat-fed appliances). Computer models of pellet stoves, boilers, DHW-units and heat-fed appliances have been developed and the parameters for the models have been identified from measurements on real components. The conformity between the models and the measurements has been checked. The systems with wood pellet stoves have been simulated in three different multi-zone buildings, simulated in detail with heat distribution through door openings between the zones. For the other simulations, either a single-zone house model or a load file has been used. Simulations were carried out for Stockholm, Sweden, but for the simulations with heat-fed machines also for Miami, USA. The foremost result of this thesis is the increased understanding of the dynamic operation of combined pellet and solar heating systems for single-family houses. The results show that electricity savings and annual system efficiency is strongly affected by the system design and the control strategy. Large reductions in pellet consumption are possible by combining pellet boilers with solar heating (a reduction larger than the solar gains if the system is properly designed). In addition, large reductions in carbon monoxide emissions are possible. To achieve these reductions it is required that the hot water production and the connection of the radiator circuit is moved to a well insulated, solar heated buffer store so that the boiler can be turned off during the periods when the solar collectors cover the heating demand. The amount of electricity replaced using systems with pellet stoves is very dependant on the house plan, the system design, if internal doors are open or closed and the comfort requirements. Proper system design and control strategies are crucial to obtain high electricity savings and high comfort with pellet stove systems. The investigated technologies for increasing the solar gains (DHW-units and heat-fed appliances) significantly increase the solar gains, but for the heat-fed appliances the market introduction is difficult due to the limited financial savings and the need for a new heat distribution system. The applications closest to market introduction could be for communal laundries and for use in sunny climates where the dominating part of the heat can be covered by solar heating. The DHW-unit is economical but competes with the internal finned-tube heat exchanger which is the totally dominating technology for hot water preparation in solar combisystems for single-family houses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Intelligent Algorithm is designed for theusing a Battery source. The main function is to automate the Hybrid System through anintelligent Algorithm so that it takes the decision according to the environmental conditionsfor utilizing the Photovoltaic/Solar Energy and in the absence of this, Fuel Cell energy isused. To enhance the performance of the Fuel Cell and Photovoltaic Cell we used batterybank which acts like a buffer and supply the current continuous to the load. To develop the main System whlogic based controller was used. Fuzzy Logic based controller used to develop this system,because they are chosen to be feasible for both controlling the decision process and predictingthe availability of the available energy on the basis of current Photovoltaic and Battery conditions. The Intelligent Algorithm is designed to optimize the performance of the system and to selectthe best available energy source(s) in regard of the input parameters. The enhance function of these Intelligent Controller is to predict the use of available energy resources and turn on thatparticular source for efficient energy utilization. A fuzzy controller was chosen to take thedecisions for the efficient energy utilization from the given resources. The fuzzy logic basedcontroller is designed in the Matlab-Simulink environment. Initially, the fuzzy based ruleswere built. Then MATLAB based simulation system was designed and implemented. Thenthis whole proposed model is simulated and tested for the accuracy of design and performanceof the system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of large discount retailers, or big-boxes as they are sometimes referred to, are often subject to heated debate and their entry on a market is greeted with either great enthusiasm or dread. For instance, the world’s largest retailer Wal-Mart (Forbes 2014) has a number of anti- and pro-groups dedicated to its being and the event of a Wal-Mart entry tends to be met with protests and campaigns (Decamme 2013) but also welcomed by, for instance, consumers (Davis & DeBonis 2013). Also in Sweden, the entry of a big box is a hot topic and before IKEA’s opening i Borlänge 2013, the first in Sweden in more than five years, great expectations were mixed with worry (Västerbottens-Kuriren 2011).The presence of large scale discount retailers is not, however, a novel phenomenon but a part of a long-term change in retailing that has taken place globally over the past couple of decades (Taylor & Smalling, 2005). As noted by Dawson (2006), the trend in Europe has over the past few decades gone towards an increasing concentration of large firms along with a decrease of smaller firms.This trend is also detectable in the Swedish retail industry. Over the past decade, the retailing industry in Sweden has increased by around 190 Billion SEK, and its share of GDP has risen from 2,7% to 2,9%, while the number of employees have increased from 200 000 to 250 000 (HUI 2013). This growth, however, has not been distributed evenly but rather it has been oriented mainly towards out-of-town retail clusters. Parallel to this development, the number of large retailers has risen at the expense of market shares of smaller independent firms (Rämme et al 2010). Thereby, the presence of large scale retailers is simply part of a changing retail landscape.The effects of this development, where large scale retailing agents relocate shopping to out-of-town shopping areas, have been heavily debated. On the one hand, the big-boxes are accused of displacing independent small retail businesses in the city-centers and the residential areas, resulting in, to some extent, reduced employment opportunities and less availability for the consumers - especially the elderly (Ljungberg et al 2006). In addition, as access to shopping now tends to require some sort of a motorized vehicle, environmental aspects to the discussion have emerged. Ultimately these types of concerns have resulted in calls for regulations against this development (Olsson 2010). On the other hand, the proponents of the new shopping landscape argue that this evolution implies productivity gains, the benefits of lower prices and an increased variety of products (Maican & Orth 2012). Moreover it is argued that it leads to, for instance, better services (such as longer opening hours) and a creative destruction transformation pressure on retailers, which brings about a renewal of city-centerIIretail and services, increasing their attractivity (Bergström 2010). The belief in benefits of a big box entry can be exemplified by the attractivity of IKEA, and the fact that municipalities are prepared to commit to expenses amounting up to hundreds of millions in order to attract the entry of this big-box. Borlänge municipality, for instance, agreed to expenses of about 350 million SEK in order to secure the entry of IKEA, which opened in 2013 (Blomgren 2009).Against this backdrop, the overall effects of large discount retailers become important: Are the economic benefits enough to warrant subsidies or are there, on the contrary, some very compelling grounds for regulations against these types of establishments? In other words; how is overall retail in a region where a store like IKEA enters affected? And how are local retail firms affected?In order to answer these questions, the purpose of this thesis is to study how entry of a big-box retailer affects the entry region. The object of this study is IKEA - one of the world’s largest retailers, with 345 stores, active in over 40 countries and with profits of about 3.3 billion (IKEA 2013; IKEA 2014). By studying the effects of IKEA-entry, both on an aggregated level and on firm level, this thesis intends to find indications of how large discount retail establishments in general can be expected to affect the economic development both in a region overall, but also on the local firm level, something which is of interest to both policymakers as well as the retailing industry in general.The first paper examines the effects of IKEA on retail revenues and employment in the municipalities that IKEA chose to enter between 2000 and 2011; Gothenburg, Haparanda, Kalmar and Karlstad. By means of a matching method we first identify non-entry municipalities that have a similar probability of IKEA entry as the true entry municipalities. Then, using these non-entry municipalities as a control group, the causal effects of IKEA entry can be estimated using a treatment-control approach. We also extend the analysis to examine the spatial impact of IKEA by estimating the effects on retail in neighboring municipalities. It is found that a new IKEA store increases revenues in durable goods trade with 20% in the entry municipality and the number of employees with 17%. Only small, and in most cases statistically insignificant, negative effects were found in neighboring municipalities.It appears that there is a positive net effect on durables retail sales and employment in the entry municipality. However, the analysis is based on data on an aggregated municipality level and thereby it remains unclear if and how the effects vary within the entry municipalities. In addition, the data used in the first study includes the sales and employment of IKEA itself, which could account for the majority of the increases in employment and retail. Thereby the potential spillover effects on incumbent retailers in the entry municipalities cannot be discerned in the first study.IIITo examine effects of IKEA entry on incumbent retail firms, the second paper in this thesis analyses how IKEA entry affects the revenues and employment of local retail firms in three municipalities; Haparanda, Kalmar and Karlstad, which experienced entry by IKEA between 2000 and 2010. In this second study, we exclude Gothenburg due to the fact that big-box entry appears to have weaker effects in metropolitan areas (as indicated by Artz & Stone 2006). By excluding Gothenburg we aim to reduce the geographical heterogeneity in our study. We obtain control municipalities that are as similar as possible to the three entry municipalities using the same method as in the previous study, but including a slightly different set of variables in the selection equation. Using similar retail firms in the control municipalities as our comparison group, we estimate the impact of IKEA entry on revenues and employment for retail firms located at varying distances from the IKEA entry site.The results generated in this study imply that entry by IKEA increases revenues in incumbent retail firms by, on average, 11% in the entry municipalities. In addition, we do not find any significant impact on retail revenues in the city centers of the entry municipalities. However, we do find that retail firms within 1 km of the IKEA experience increases in revenues of about 26%, which indicates large spillover effects in the area nearby the entry site. As expected, this impact decreases as we expand the buffer zone: firms located between 0-2 km experiences a 14% increase and firms in 2-5 km experiences an increase of 10%. We do not find any significant impacts on retail employment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study the monitoring results of prototype installation of a recently developed solar combisystem have been evaluated. The system, that uses a water jacketed pellet stove as auxiliary heater, was installed in a single family house in Borlänge/Sweden. In order to allow an evaluation under realistic conditions the system has been monitored for a time period of one year. From the measurements of the system it could be seen that it is important that the pellet stove has a sufficient buffer store volume to minimize cycling. The measurements showed also that the stove gives a lower share of the produced heat to the water loop than measured under stationary conditions. The solar system works as expected and covers the heat demand during the summer and a part of the heat demand during spring and autumn. Potential for optimization exists for the parasitic electricity demand. The system consumes 680 kWh per year for pumps, valves and controllers which is more than 4% of the total primary heating energy demand.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this project is to provide an explanation for recently obtained binding constants for two similar guest molecules, NDMG and N-MAP, with a p-sulfonatocalix[6]arene host in ammonium acetate buffer. This work was done primarily using pressure perturbation calorimetry, which is a technique that determines the coefficient of thermal expansion, α, which is in turn related to the solute molecule's effect on the order of the surrounding water molecules. A series of experiments were designed to test the effects of suspected confounding variables on the validity of PPC data. PPC was then used to study NDMG and N-MAP in ammonium acetate buffer. NDMG exhibited a minimum in α as function of temperature, while N-MAP did not. This difference was theorized to be due to the formation of an intramolecular hydrogen bond in monocationic NDMG that would lower the heat capacity of the molecule and better distribute the molecule's charge. Computational work and nuclear magnetic resonance spectroscopy confirmed that monocationic, ring-closed NDMG has less concentrated charge and more constrained motion than monocationic, ring-open NDMG. This evidence supports the theory that monocationic NDMG forms an intramolecular hydrogen bond and that this may be responsible for the minimum in α. This difference may explain the differences in binding constants between NDMG and N-MAP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Variable leaf milfoil, Myriophyllum heterophyllum, has been present in Maine since 1970. We created an analysis area including seventeen infestation sites and all bodies of water within a forty mile buffer. We also eliminated all water locations with a size less than 7,101 km2, the size of the smallest infestation site, Shagg Pond. Within those specifications we randomly selected seventeen un-infested bodies of water and used them as our uncontaminated sample. We looked for relationships between presence and number of boat launches, and proximity to a populated area. Using the Mann-Whitney test, we compared the sample size of non-infested lakes to the infested lakes. We found there was no significant difference in all three variables on the infestation of variable leaf milfoil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho teve por objetivo determinar a ação inibidora do íon borato na corrosão do aço-carbono, em soluções aquosas aproximadamente neutras, arejadas e desarejadas, na presença ou não de ions cloreto, à temperatura ambiente. Através do traçado de curvas de polarização potenciostáticas, de experimentos cronopotenciométricos e cronogalvanométricos, com ou sem riscagem do corpo de prova, e do comportamento do aço comum em ensaios de imersão a longo prazo, concluiu-se que o ion borato possui uma ação inibidora sobre a corrosão do aço, desde que o potencial não seja muito elevado. Observou-se também que o aço sofre corrosão por pites em soluções de borato, mesmo na ausência de íons agressivos e que os pites ocorrem em potenciais tanto mais baixos quanto mais diluídas forem as soluções de borato. Para soluções contendo 1000 ppm de bórax ou mais, o potencial de pite, determinado por técnicas cronopotenciométricas, está acima do potencial de corrosão. Para soluções com concentrações iguais ou superiores a 5000 ppm de bórax, não foi detectada corrosão por pites na faixa de potencial estudada, isto é, desde o potencial de evolução de H2 até o potencial de evolução de 02. A adição de 100 ppm de NaCl à solução contendo 2500 ppm de bórax reduz o potencial de pite de aço comum, em relação ao seu valor na ausência de íon cloreto.