935 resultados para Bonded joints
Resumo:
We examined the effect of surface-applied treatments on the above-ground decay resistance of the tenon of mortice-and-tenon timber joints designed to simulate joinery that is exposed to the weather. Joints made from untreated radiata pine, Douglas-fir, brush box, spotted gum and copper-chrome-arsenic (CCA) treated radiata pine were exposed to the weather for 9 y on above-ground racks at five sites throughout eastern Australia. Results indicate (1) a poorly maintained external paint film generally accelerated decay, (2) a brush coat of water-repellent preservative inside the joints often extended serviceability (in some cases by a factor of up to seven times that of untreated joints) and (3) the level of protection provided by a coat of primer applied inside the joint varied and in most cases was not as effective as the water-repellent preservative treatment.
Resumo:
The suzukacillin fragments, Boc-Ala-Aib-Aib-Gln-Aib-Leu-Aib-Gly-Leu-Aib-Pro-Val-Aib-Aib-OMe (14), Boc-Ala-Aib-Ala-Aib-Aib-Gln-Aib-Leu-Aib-Gly-Leu-Aib-Pro-Val-Aib-Aib-OMe (16G) and the completely apolar 16-residue peptide in which the glutamine residue has been replaced by alanine (16A) have been studied by 270 MHz 1H-HMR, in C2HCl3 and (C2H3)2SO solution. Intramolecularly hydrogen-bonded NH groups have been identified by temperature and solvent dependence of chemical shifts. Peptides 14 and 16A adopt folded 310 helical conformations stabilized by 11 and 13 hydrogen bonds, respectively. In peptide 16G there are 12 intramolecular hydrogen bonds, with the glycine NH being solvent-exposed, in contrast to 14 and 16A.
Resumo:
Background Segmental biomechanics of the scoliotic spine are important since the overall spinal deformity is comprised of the cumulative coronal and axial rotations of individual joints. This study investigates the coronal plane segmental biomechanics for adolescent idiopathic scoliosis patients in response to physiologically relevant axial compression. Methods Individual spinal joint compliance in the coronal plane was measured for a series of 15 idiopathic scoliosis patients using axially loaded magnetic resonance imaging. Each patient was first imaged in the supine position with no axial load, and then again following application of an axial compressive load. Coronal plane disc wedge angles in the unloaded and loaded configurations were measured. Joint moments exerted by the axial compressive load were used to derive estimates of individual joint compliance. Findings The mean standing major Cobb angle for this patient series was 46°. Mean intra-observer measurement error for endplate inclination was 1.6°. Following loading, initially highly wedged discs demonstrated a smaller change in wedge angle, than less wedged discs for certain spinal levels (+ 2,+1,− 2 relative to the apex, (p < 0.05)). Highly wedged discs were observed near the apex of the curve, which corresponded to lower joint compliance in the apical region. Interpretation While individual patients exhibit substantial variability in disc wedge angles and joint compliance, overall there is a pattern of increased disc wedging near the curve apex, and reduced joint compliance in this region. Approaches such as this can provide valuable biomechanical data on in vivo spinal biomechanics of the scoliotic spine, for analysis of deformity progression and surgical planning.
Resumo:
The intervertebral disc withstands large compressive loads (up to nine times bodyweight in humans) while providing flexibility to the spinal column. At a microstructural level, the outer sheath of the disc (the annulus fibrosus) comprises 12–20 annular layers of alternately crisscrossed collagen fibres embedded in a soft ground matrix. The centre of the disc (the nucleus pulposus) consists of a hydrated gel rich in proteoglycans. The disc is the largest avascular structure in the body and is of much interest biomechanically due to the high societal burden of disc degeneration and back pain. Although the disc has been well characterized at the whole joint scale, it is not clear how the disc tissue microstructure confers its overall mechanical properties. In particular, there have been conflicting reports regarding the level of attachment between adjacent lamellae in the annulus, and the importance of these interfaces to the overall integrity of the disc is unknown. We used a polarized light micrograph of the bovine tail disc in transverse cross-section to develop an image-based finite element model incorporating sliding and separation between layers of the annulus, and subjected the model to axial compressive loading. Validation experiments were also performed on four bovine caudal discs. Interlamellar shear resistance had a strong effect on disc compressive stiffness, with a 40% drop in stiffness when the interface shear resistance was changed from fully bonded to freely sliding. By contrast, interlamellar cohesion had no appreciable effect on overall disc mechanics. We conclude that shear resistance between lamellae confers disc mechanical resistance to compression, and degradation of the interlamellar interface structure may be a precursor to macroscopic disc degeneration.
Resumo:
The team of authors and, particularly the senior authors, is known for their work focusing on osseointegration. Over the last 10 years, they have published some significant work that is highly regarded and cited by the community of researchers working on the development of osseointegrated fixations. Furthermore, Professor Pitkin is also acknowledged internationally for his fine experimental skills and ability to design research that is typically outside the square...
Resumo:
Objective To improve the isolation rate and identification procedures for Haemophilus parasuis from pig tissues. Design Thirteen sampling sites and up to three methods were used to confirm the presence of H. parasuis in pigs after experimental challenge. Procedure Colostrum-deprived, naturally farrowed pigs were challenged intratracheally with H parasuis serovar 12 or 4. Samples taken during necropsy were either inoculated onto culture plates, processed directly for PCR or enriched prior to being processed for PCR. The recovery of H parasuis from different sampling sites and using different sampling methods was compared for each serovar. Results H parasuis was recovered from several sample sites for all serovar 12 challenged pigs, while the trachea was the only positive site for all pigs following serovar 4 challenge. The method of solid medium culture of swabs, and confirmation of the identity of cultured bacteria by PCR, resulted in 38% and 14% more positive results on a site basis for serovars 12 and 4, retrospectively, than direct PCR on the swabs. This difference was significant in the serovar 12 challenge. Conclusion Conventional culture proved to be more effective in detecting H parasuis than direct PCR or PCR on enrichment broths. For subacute (serovar 4) infections, the most successful sites for culture or direct PCR were pleural fluid, peritoneal fibrin and fluid, lung and pericardial fluid. For acute (serovar 12) infections, the best sites were lung, heart blood, affected joints and brain. The methodologies and key sampling sites identified in this study will enable improved isolation of H parasuis and aid the diagnosis of Glässer's disease.
Resumo:
We demonstrate the aptitude of supramolecular hydrogel formation using simple bile acid such as lithocholic acid in aqueous solution in the presence of various dimeric or oligomeric amines. By variation of the choice of the amines in such mixtures the gelation properties could be modulated. However, the replacement of lithocholic acid (LCA) by cholic acid or deoxycholic acid resulted in no hydrogel formation. FT-IR studies confirm that the carboxylate and ammonium residues of the two components are involved in the salt (ion-pair) formation. This promotes further assembly of the components reinforced by a continuous hydrogen bonded network leading to gelation. Electron microscopy shows the morphology of the internal organization of gels of two component systems which also depends significantly on the amine part. Variation of the amine component from the simple 1,2-ethanediamine (EDA) to oligomeric amines in such gels of lithocholic acid changes the morphology of the assembly from long one-dimensional nanotubes to three-dimensional complex structures. Single crystal X-ray diffraction analysis with one of the amine-LCA complexes suggested the motif of fiber formation where the amines interact with the carboxylate and hydroxyl moieties through electrostatic forces and hydrogen bonding. From small angle neutron scattering study, it becomes clear that the weak gel from LCA-EDA shows scattering oscillation due to the presence of non-interacting nanotubules while for gels of LCA with oligomeric amines the individual fibers come together to form complex three-dimensional organizations of higher length scale. The rheological properties of this class of two component system provide clear evidence that the flow behavior can be modulated varying the acid-amine ratio.
Resumo:
This paper presents a validation study on the application of a novel interslice interpolation technique for musculoskeletal structure segmentation of articulated joints and muscles on human magnetic resonance imaging data. The interpolation technique is based on morphological shape-based interpolation combined with intensity based voxel classification. Shape-based interpolation in the absence of the original intensity image has been investigated intensively. However, in some applications of medical image analysis, the intensity image of the slice to be interpolated is available. For example, when manual segmentation is conducted on selected slices, the segmentation on those unselected slices can be obtained by interpolation. We proposed a two- step interpolation method to utilize both the shape information in the manual segmentation and local intensity information in the image. The method was tested on segmentations of knee, hip and shoulder joint bones and hamstring muscles. The results were compared with two existing interpolation methods. Based on the calculated Dice similarity coefficient and normalized error rate, the proposed method outperformed the other two methods.
Resumo:
The basic cyclic hexapeptide conformations which accommodate hydrogen bonded β and γ turns in the backbone have been worked out using stereochemical criteria and energy minimization procedures. It was found that cyclic hexapeptides can be made up of all possible combinations of 4 ± 1 hydrogen bonded types I, I', II and II' β turns, giving rise to symmetric conformations having twofold and inversion symmetries as well as nonsymmetric structures. Conformations having exclusive features of 3 ± 1 hydrogen bonded γ turns were found to be possible in threefold and S6 symmetric cyclic hexapeptides. The results show that the cyclic hexapeptides formed by the linking of two β turn tripeptide fragments differ mainly in (a) the hydrogen bonding scheme present in the β turn tripeptides and (b) the conformation at the α-carbon atoms where the two tripeptide fragments link. The different hydrogen bonding schemes found in the component β turns are: 1) a β turn with only a 4 ± 1 hydrogen bond, 2) a type I or I' β turn with 4 ± 1 and 3 ± 1 hydrogen bonds occurring in a bifurcated form and 3) a type II or II' β turn having both the 4 ± 1 and the 3 ± 1 hydrogen bonds with the same acceptor oxygen atom. The conformation at the linking α-carbon atoms was found to lie either in the extended region or in the 3 ± 1 hydrogen bonded γ turn or inverse γ turn regions. Further, the threefold and the S6 symmetric conformations have three γ turns interleaved by three extended regions or three inverse γ turns, respectively. The feasibility of accommodating alanyl residues of both isomeric forms in the CHP minima has been explored. Finally, the available experimental data are reviewed in the light of the present results.
Resumo:
Fifth annual Trafficking in Persons Report prepared by the Department of State and submitted to the U.S. Congress on foreign governments' efforts to eliminate severe forms of trafficking in persons.
Resumo:
Plasticity in amorphous alloys is associated with strain softening, induced by the creation of additional free volume during deformation. In this paper, the role of free volume, which was a priori in the material, on work softening was investigated. For this, an as-cast Zr-based bulk metallic glass (BMG) was systematically annealed below its glass transition temperature, so as to reduce the free volume content. The bonded-interface indentation technique is used to generate extensively deformed and well defined plastic zones. Nanoindentation was utilized to estimate the hardness of the deformed as well as undeformed regions. The results show that the structural relaxation annealing enhances the hardness and that both the subsurface shear band number density and the plastic zone size decrease with annealing time. The serrations in the nanoindentation load-displacement curves become smoother with structural relaxation. Regardless of the annealing condition, the nanohardness of the deformed regions is similar to 12-15% lower, implying that the prior free volume only changes the yield stress (or hardness) but not the relative flow stress (or the extent of strain softening). Statistical distributions of the nanohardness obtained from deformed and undeformed regions have no overlap, suggesting that shear band number density has no influence on the plastic characteristics of the deformed region.
Resumo:
Usage of new smart materials in retrofitting of structures has become popular within last decade. Carbon fiber reinforced polymer (CFRP) has been widely used in retrofitting and strengthening of concrete structures and its usage in metallic structures is still in the developing stage. The variation of mechanical properties of CFRP and the consequent effects on strengthening and retrofitting CFRP systems are yet to be investigated under different loading and environmental conditions. This paper presents the results of CFRP strengthened and retrofitted corroded steel plate double strap joints under tension. An accelerated corrosion cell has been developed to accelerate the corrosion of the steel samples and CFRP strengthened samples. The results show a direct comparison of bond characteristics of CFRP strengthened and retrofitted steel double strap joints.
Resumo:
4-Butyl-4-hydroxy-l-phenyl-3,5-pyrazolidinedione, ClaH16N20 a, Mr=248.3, monoclinic, P21/n, a = 22.357 (5), b = 5.014 (2), c = 11.350 (4)/~,, //=91.88(3) °, V=1272(1)A 3, Z=4, D,,=1.296(3), D x = 1.297 Mg m -3, 2(Cu Ka) = 1.5418/~, a = 0.777 mm -~, F(000) = 528, T= 293 K. Final R - 0.059 for 1668 observed reflections. The hetero nitrogen which carries the six-membered ring is planar in the structure while the other unsubstituted one is pyramidal. The five- and six-membered rings are almost coplanar. The crystal is made up of infinite columns of hydrogen-bonded molecules.
Resumo:
Concrete filled steel tubular (CFST) columns are increasingly used in bridge piers and high-rise buildings due to their excellent axial load bearing capacity. These columns may experience severe damage or failure due to transverse impact of vehicle collisions. In this study, numerical investigation is carried out to evaluate the effect of carbon fibre reinforced polymer (CFRP) strengthening CFST columns under vehicular impact. The CFRP composites damage mechanisms are simulated to account four different failure criteria. The cohesive elements are introduced as interface element to properly simulate the adhesively bonded regime. Simplified vehicle model is also developed to represent real vehicle behaviour. The FE analysis results show that externally bonded CFRP composites improve the impact resistance capacity compared to bare CFST column.
Resumo:
Introduction and Objectives Joint moments and joint powers during gait are widely used to determine the effects of rehabilitation programs as well as prosthetic fitting. Following the definition of power (dot product of joint moment and joint angular velocity) it has been previously proposed to analyse the 3D angle between both vectors, αMw. Basically, joint power is maximised when both vectors are parallel and cancelled when both vectors are orthogonal. In other words, αMw < 60° reveals a propulsion configuration (more than 50% of the moment contribute to positive power) while αMw > 120° reveals a resistance configuration (more than 50% of the moment contribute to negative power). A stabilisation configuration (less than 50% of the moment contribute to power) corresponds to 60° < αMw < 120°. Previous studies demonstrated that hip joints of able-bodied adults (AB) are mainly in a stabilisation configuration (αMw about 90°) during the stance phase of gait. [1, 2] Individuals with transfemoral amputation (TFA) need to maximise joint power at the hip while controlling the prosthetic knee during stance. Therefore, we tested the hypothesis that TFAs should adopt a strategy that is different from a continuous stabilisation. The objective of this study was to compute joint power and αMw for TFA and to compare them with AB. Methods Three trials of walking at self-selected speed were analysed for 8 TFAs (7 males and 1 female, 46±10 years old, 1.78±0.08 m 82±13 kg) and 8 ABs (males, 25±3 years old, 1.75±0.04, m 67±6 kg). The joint moments are computed from a motion analysis system (Qualisys, Goteborg, Sweden) and a multi-axial transducer (JR3, Woodland, USA) mounted above the prosthetic knee for TFAs and from a motion analysis system (Motion Analysis, Santa Rosa, USA) and force plates (Bertec, Columbus, USA) for ABs. The TFAs were fitted with an OPRA (Integrum, AB, Gothengurg, Sweden) osseointegrated implant system and their prosthetic designs include pneumatic, hydraulic and microprocessor knees. Previous studies showed that the inverse dynamics computed from the multi-axial transducer is the proper method considering the absorption at the foot and resistance at the knee. Results The peak of positive power at loading response (H1) was earlier and lower for TFA compared to AB. Although the joint power is lower, the 3D angle between joint moment and joint angular velocity, αMw, reveals an obvious propulsion configuration (mean αMw about 20°) for TFA compared to a stabilisation configuration (mean αMw about 70°) for AB. The peaks of negative power at midstance (H2) and of positive power at preswing / initial swing (H3) occurred later, lower and longer for TFA compared to AB. Again, the joint powers are lower for TFA but, in this case, αMw is almost comparable (with a time lag), demonstrating a stabilisation (almost a resistance for TFA, mean αMw about 120°) and a propulsion configuration, respectively. The swing phase is not analysed in the present study. Conclusion The analysis of hip joint power may indicate that TFAs demonstrated less propulsion and resistance than ABs during the stance phase of gait. This is true from a quantitative point of view. On the contrary, the 3D angle between joint moment and joint angular velocity, αMw, reveals that TFAs have a remarkable propulsion strategy at loading response and almost a resistance strategy at midstance while ABs adopted a stabilisation strategy. The propulsion configuration, with αMw close to 0°, seems to aim at maximising the positive joint power. The configuration close to resistance, with αMw far from 180°, might aim at unlocking the prosthetic knee before swing while minimising the negative power. This analysis of both joint power and 3D angle between the joint moment and the joint angular velocity provides complementary insights into the gait strategies of TFA that can be used to support evidence-based rehabilitation and fitting of prosthetic components.