931 resultados para Blood pressure determination


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background and objective: There are no data about the influence of anaesthetics on cardiovascular variables during pressure support ventilation of the lungs through the laryngeal mask airway. We compared propofol, sevoflurane and isoflurane for maintenance of anaesthesia with the ProSeal (R) laryngeal mask airway during pressure support ventilation. Methods: Sixty healthy adults undergoing peripheral musculo-skeletal surgery were randomized for maintenance with sevoflurane end-tidal 29%, isoflurane end-tidal 1.1% or propofol 6 mg kg(-1) h(-1) in oxygen 33% and air. Pressure support ventilation comprised positive end-expiratory pressure set at 5 cmH(2)O, and pressure support set 5 cmH(2)O above positive end-expiratory pressure. Pressure support was initiated when inspiration produced a 2 cmH(2)O reduction in airway pressure. A blinded observer recorded cardiorespiratory variables (heart rate, mean blood pressure, oxygen saturation, air-way occlusion pressure, respiratory rate, expired tidal volume, expired minute volume and end-tidal CO2), adverse events and emergence times. Results: Respiratory rate and minute volume were 10-21% lower, and end-tidal CO2 6-11% higher with the propofol group compared with the sevoflurane or isoflurane groups, but otherwise cardiorespiratory variables were similar among groups. No adverse events occurred in any group. Emergence times were longer with the propofol group compared with the sevoflurane or isoflurane groups (10 vs. 7 vs. 7 min). Conclusion: Lung ventilation is less effective and emergence times are longer with propofol than sevoflurane or isoflurane for maintenance of anaesthesia during pressure support ventilation with the ProSeal (R) laryngeal mask airway. However, these differences are small and of doubtful clinical importance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The blood types determination is essential to perform safe blood transfusions. In emergency situations isadministrated the “universal donor” blood type. However, sometimes, this blood type can cause incom-patibilities in the transfusion receptor. A mechatronic prototype was developed to solve this problem.The prototype was built to meet specific goals, incorporating all the necessary components. The obtainedsolution is close to the final system that will be produced later, at industrial scale, as a medical device.The prototype is a portable and low cost device, and can be used in remote locations. A computer appli-cation, previously developed is used to operate with the developed mechatronic prototype, and obtainautomatically test results. It allows image acquisition, processing and analysis, based on Computer Visionalgorithms, Machine Learning algorithms and deterministic algorithms. The Machine Learning algorithmsenable the classification of occurrence, or alack of agglutination in the mixture (blood/reagents), and amore reliable and a safer methodology as test data are stored in a database. The work developed allowsthe administration of a compatible blood type in emergency situations, avoiding the discontinuity of the“universal donor” blood type stocks, and reducing the occurrence of human errors in the transfusion practice.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background. To evaluate the haemodynamic features of young healthy myopes and emmetropes, in order to ascertain the perfusion profile of human myopia and its relationship with axial length prior to reaching a degenerative state. Methods The retrobulbar, microretinal and pulsatile ocular blood flow (POBF) of one eye of each of twenty-two high myopes (N=22, mean spherical equivalent (MSE) =-5.00D), low myopes (N=22, MSE-1.00 to-4.50D) and emmetropes (N=22, MSE±0.50D) was analyzed using color Doppler Imaging, Heidelberg retinal flowmetry and ocular blood flow analyser (OBF) respectively. Intraocular pressure, axial length (AL), systemic blood pressure, and body mass index were measured. Results. When compared to the emmetropes and low myopes, the AL was greater in high myopia (p<0.0001). High myopes showed higher central retinal artery resistance index (CRA RI) (p=0.004), higher peak systolic to end diastolic velocities ratio (CRA ratio) and lower end diastolic velocity (CRA EDv) compared to low myopes (p=0.014, p=0.037). Compared to emmetropes, high myopes showed lower OBFamplitude (OBFa) (p=0.016). The POBF correlated significantly with the systolic and diastolic blood velocities of the CRA (p=0.016, p=0.036). MSE and AL correlated negatively with OBFa (p=0.03, p=0.003), OBF volume (p=0.02, p<0.001), POBF (p=0.01, p<0.001) and positively with CRA RI (p=0.007, p=0.05). Conclusion. High myopes exhibited significantly reduced pulse amplitude and CRA blood velocity, the first of which may be due to an OBF measurement artefact or real decreased ocular blood flow pulsatility. Axial length and refractive error correlated moderately with the ocular pulse and with the resistance index of the CRA, which in turn correlated amongst themselves. It is hypothesized that the compromised pulsatile and CRA haemodynamics observed in young healthy myopes is an early feature of the decrease in ocular blood flow reported in pathological myopia. Such vascular features would increase the susceptibility for vascular and age-related eye diseases.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose. To assess the relationship between macular pigment optical density (MPOD) and blood markers for antioxidant defense in otherwise healthy volunteers. Methods. Forty-seven healthy volunteers were subjected to blood analysis to detect the level of circulating glutathione in its reduced (GSH) and oxidized (GSSG) forms. The level of MPOD was measured using heterochromatic flicker photometry. Systemic blood pressure (BP) parameters, heart rate (HR), body mass index (BMI), and plasma levels of total, HDL, and LDL cholesterol and triglycerides (TGs) were also determined. Results. A simple correlation model revealed that the level of MPOD correlated significantly and positively with both GSH (P < 0.001) and t-GSH (P < 0.001) levels but not with those of GSSG (P > 0.05). Age, sex, systemic BP parameters, HR, BMI, and plasma levels of cholesterol and TGs did not have any influence on either MPOD or glutathione levels (all P > 0.05). In addition, a forward stepwise multiple regression analysis showed MPOD to have a significantly and independent correlation with GSH levels (ß = 0.63; P < 0.001). Conclusions. In otherwise healthy older individuals, there is a positive correlation between local and systemic antioxidant defense mechanisms.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This thesis was concerned with investigating methods of improving the IOP pulse’s potential as a measure of clinical utility. There were three principal sections to the work. 1. Optimisation of measurement and analysis of the IOP pulse. A literature review, covering the years 1960 – 2002 and other relevant scientific publications, provided a knowledge base on the IOP pulse. Initial studies investigated suitable instrumentation and measurement techniques. Fourier transformation was identified as a promising method of analysing the IOP pulse and this technique was developed. 2. Investigation of ocular and systemic variables that affect IOP pulse measurements In order to recognise clinically important changes in IOP pulse measurement, studies were performed to identify influencing factors. Fourier analysis was tested against traditional parameters in order to assess its ability to detect differences in IOP pulse. In addition, it had been speculated that the waveform components of the IOP pulse contained vascular characteristic analogous to those components found in arterial pulse waves. Validation studies to test this hypothesis were attempted. 3. The nature of the intraocular pressure pulse in health and disease and its relation to systemic cardiovascular variables. Fourier analysis and traditional parameters were applied to the IOP pulse measurements taken on diseased and healthy eyes. Only the derived parameter, pulsatile ocular blood flow (POBF) detected differences in diseased groups. The use of an ocular pressure-volume relationship may have improved the POBF measure’s variance in comparison to the measurement of the pulse’s amplitude or Fourier components. Finally, the importance of the driving force of pulsatile blood flow, the arterial pressure pulse, is highlighted. A method of combining the measurements of pulsatile blood flow and pulsatile blood pressure to create a measure of ocular vascular impedance is described along with its advantages for future studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE. To investigate in parallel the systemic glutathione levels of patients suffering from primary open angle glaucoma (POAG) or normal tension glaucoma (NTG) with comparable functional loss. METHODS. Thirty-four POAG patients, 30 NTG patients, and 53 controls were subjected to blood analysis to detect the level of circulating glutathione in its reduced (GSH) and oxidized (GSSG) forms. Systemic blood pressure (BP) and ocular perfusion pressure (OPP) parameters were also determined. RESULTS. Independent of age, POAG and NTG patients demonstrated significantly lower GSH and t-GSH levels than age-matched controls (P < 0.001). Additionally, a lower redox index was found, but in POAG patients only, in comparison to both NTG and control groups (P = 0.020). GSSG levels were, however, similar between all study groups (P > 0.05). CONCLUSIONS. This study demonstrates, for the first time, that both POAG and NTG patients exhibit lower GSH and t-GSH levels than age-matched controls, indicating a similar general compromise of the antioxidant defense systems may exist in both conditions. © 2013 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: This pilot study aimed to investigate systemic and retinal vascular function and their relationship to circulatory markers of cardiovascular risk in early age-related macular degeneration (AMD) patients without any already diagnosed systemic vascular pathologies. Methods: Fourteen patients diagnosed with early AMD and 14 age- and gender-matched healthy controls underwent blood pressure, carotid intima-media thickness (C-IMT) and peripheral arterial stiffness measurements. Retinal vascular reactivity was assessed by means of dynamic retinal vessel analysis (DVA) using a modified protocol. Blood analyses were conducted for glutathione levels and plasma levels of total cholesterol (CHOL), high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C) and triglycerides (TG). Results: The AMD patients showed significantly greater C-IMT (p = 0.029) and augmentation index (AIx) (p = 0.042) than the age-matched controls. In addition, they demonstrated a shallower retinal arterial dilation slope (Slope AD) (p = 0.005) and a longer retinal venous reaction time (RT) to flickering light (p = 0.026). Blood analyses also revealed that AMD patients exhibited higher oxidized glutathione (GSSG) (p = 0.024), lower redox index (p = 0.043) and higher LDL-C (p = 0.033) levels than the controls. Venous RT parameter correlated positively with blood GSSG levels (r = 0.58, p = 0.038) in AMD subjects, but not in the controls (p > 0.05). Conclusions: Patients diagnosed with early AMD exhibit signs of systemic and retinal vascular alterations that correlated with known risk markers for future cardiovascular morbidity. © 2013 Springer-Verlag Berlin Heidelberg.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Arterial pulse pressure, the difference between systolic and diastolic blood pressure, has been used as an indicator (surrogate measure) of arterial stiffness. High arterial pulse pressure (> 40) has been associated with increased cardiovascular disease and mortality. Several clinical trials have reported that the proportion of calories from carbohydrate has an effect on blood pressure. The primary objective of this study was to assess arterial pulse pressure and its association with carbohydrate quantity and quality (glycemic load) with diabetes status for a Cuban American population. Methods: A single point analysis included 367 participants. There was complete data for 365 (190 with and 175 without type 2 diabetes). The study was conducted in the investigator’s laboratory located in Miami, Florida. Demographic, dietary, anthropometric and laboratory data were collected. Arterial pulse pressure was calculated by the formula systolic minus the diastolic blood pressure. Glycemic load, fructose, sucrose, percent of average daily calories from carbohydrate, fat and protein, grams of fiber and micronutrient intakes were calculated from a validated food frequency questionnaire. Results: The mean arterial pulse pressure was significantly higher in participants with (52.9 ± 12.4) than without (48.6 ± 13.4) type 2 diabetes. The odds of persons with diabetes having high arterial pulse pressure (>40) was 1.85 (95% CI =1.09, 3.13); p=0.023. For persons with type 2 diabetes higher glycemic load was associated with lower arterial pulse pressure. Conclusions: Arterial pulse pressure and diet are modifiable risk factors of cardiovascular disease. Arterial pulse pressure may be associated with carbohydrate intake differently considering diabetes status. Results may be due to individuals with diabetes following dietary recommendations. The findings of this study suggest clinicians take into consideration how medical condition, ethnicity and diet are associated with arterial pulse pressure before developing a medical nutrition therapy plan in collaboration with the client.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study examined the relationships among ethnicity/race, lifestyle factors, phylloquinone (vitamin K₁) intake, and arterial pulse pressure in a nationally representative sample of older adults from four ethnic/racial groups: non-Hispanic Whites, non-Hispanic Blacks, Mexican Americans, and other Hispanics. This was a cross-sectional study of U.S. representative sample with data from the National Health and Nutrition Examination Surveys, 2007-2008 and 2009-2010 of adults aged 50 years and older (N = 5296). Vitamin K intake was determined by 24-hour recall. Pulse pressure was calculated as the difference between the averages of systolic blood pressure and diastolic blood pressure. Compared to White non-Hispanics, the other ethnic/racial groups were more likely to have inadequate vitamin K₁ intake. Inadequate vitamin K₁ intake was an independent predictor of high arterial pulse pressure. This was the first study that compared vitamin K₁ inadequacy with arterial pulse pressure across ethnicities/races in U.S. older adults. These findings suggest that vitamin K screening may be a beneficial marker for the health of older adults.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Microcirculatory vessels are lined by endothelial cells (ECs) which are surrounded by a single or multiple layer of smooth muscle cells (SMCs). Spontaneous and agonist induced spatiotemporal calcium (Ca2+) events are generated in ECs and SMCs, and regulated by complex bi-directional signaling between the two layers which ultimately determines the vessel tone. The contractile state of microcirculatory vessels is an important factor in the determination of vascular resistance, blood flow and blood pressure. This dissertation presents theoretical insights into some of the important and currently unresolved phenomena in microvascular tone regulation. Compartmental and continuum models of isolated EC and SMC, coupled EC-SMC and a multi-cellular vessel segment with deterministic and stochastic descriptions of the cellular components were developed, and the intra- and inter-cellular spatiotemporal Ca2+ mobilization was examined. Coupled EC-SMC model simulations captured the experimentally observed localized subcellular EC Ca2+ events arising from the opening of EC transient receptor vanilloid 4 (TRPV4) channels and inositol triphosphate receptors (IP3Rs). These localized EC Ca2+ events result in endothelium-derived hyperpolarization (EDH) and Nitric Oxide (NO) production which transmit to the adjacent SMCs to ultimately result in vasodilation. The model examined the effect of heterogeneous distribution of cellular components and channel gating kinetics in determination of the amplitude and spread of the Ca2+ events. The simulations suggested the necessity of co-localization of certain cellular components for modulation of EDH and NO responses. Isolated EC and SMC models captured intracellular Ca2+ wave like activity and predicted the necessity of non-uniform distribution of cellular components for the generation of Ca2+ waves. The simulations also suggested the role of membrane potential dynamics in regulating Ca2+ wave velocity. The multi-cellular vessel segment model examined the underlying mechanisms for the intercellular synchronization of spontaneous oscillatory Ca2+ waves in individual SMC. From local subcellular events to integrated macro-scale behavior at the vessel level, the developed multi-scale models captured basic features of vascular Ca2+ signaling and provide insights for their physiological relevance. The models provide a theoretical framework for assisting investigations on the regulation of vascular tone in health and disease.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-08

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Enquadramento: A gestão da doença, designadamente da hipertensão arterial (HTA) através do apoio à auto-gestão, aconselhamento motivacional, acesso à informação resultam em maior adesão terapêutica. Objetivos: Identificar os fatores que determinam a adesão ao tratamento na pessoa com HTA numa amostra comunitária. Metodologia: Estudo transversal, descritivo-correlacional, com amostra de 235 hipertensos (63,8% do género feminino), idade média 75 ± 8,14 anos, 62,6% casados e a maioria com o 1.º ciclo de escolaridade. Recorremos ao questionário com variáveis sociodemográficas, dietéticas, clínicas, motivacionais, relacionadas com os profissionais e serviços de saúde, Escala de Apgar Familiar, Questionário de Dependência Alcoólica, Questionário Internacional de Atividade Física, Questionário de Determinação da Saúde Nutricional, Escala de Autocuidado com a Hipertensão, Questionário de Crenças Sobre a Doença, Escala de Crenças Acerca dos Medicamentos, Escala de Satisfação dos Utentes com os Cuidados de Enfermagem na Unidade Móvel de Saúde, Questionário abreviado da Perceção do Cliente sobre o Ambiente Terapêutico, Questionário de Autorregulação, Escala de Competência Percebida e Escala de Medida de Adesão aos Tratamentos para colheita de dados. Resultados: A pressão arterial estava controlada em 34,5% da amostra, 28,2% homens e 38% mulheres. A MAT revelou um mínimo de 3,86 e um máximo de 6 com uma média de 5,66±0,49. As variáveis preditoras da adesão foram: controlo pessoal (p=0,005), identidade (p=0,000), ambiente terapêutico (p=0,001), alimentação geral (p=0,041), atividade física (p=0,007) e toma de medicamentos (p=0,000). Conclusões: Compreender os fatores envolvidos na gestão do tratamento permite perceber como podem os enfermeiros contribuir para melhorar a adesão ao regime terapêutico. Palavras-chave: Hipertensão arterial, gestão da doença crónica, adesão ao tratamento e adultos.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nowadays complementary diagnostic methods are replacing clinical examination and semiology is loosing space in our clinical practice. One of our main concerns in clinical practice is to assess Cardiovascular risk (CVR). And previous studies reported an increased CVR with a divergence of 10mmhg or more measured between both arms-interarm blood pressure difference (IAD)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Microcirculatory vessels are lined by endothelial cells (ECs) which are surrounded by a single or multiple layer of smooth muscle cells (SMCs). Spontaneous and agonist induced spatiotemporal calcium (Ca2+) events are generated in ECs and SMCs, and regulated by complex bi-directional signaling between the two layers which ultimately determines the vessel tone. The contractile state of microcirculatory vessels is an important factor in the determination of vascular resistance, blood flow and blood pressure. This dissertation presents theoretical insights into some of the important and currently unresolved phenomena in microvascular tone regulation. Compartmental and continuum models of isolated EC and SMC, coupled EC-SMC and a multi-cellular vessel segment with deterministic and stochastic descriptions of the cellular components were developed, and the intra- and inter-cellular spatiotemporal Ca2+ mobilization was examined.^ Coupled EC-SMC model simulations captured the experimentally observed localized subcellular EC Ca2+ events arising from the opening of EC transient receptor vanilloid 4 (TRPV4) channels and inositol triphosphate receptors (IP3Rs). These localized EC Ca2+ events result in endothelium-derived hyperpolarization (EDH) and Nitric Oxide (NO) production which transmit to the adjacent SMCs to ultimately result in vasodilation. The model examined the effect of heterogeneous distribution of cellular components and channel gating kinetics in determination of the amplitude and spread of the Ca2+ events. The simulations suggested the necessity of co-localization of certain cellular components for modulation of EDH and NO responses. Isolated EC and SMC models captured intracellular Ca2+ wave like activity and predicted the necessity of non-uniform distribution of cellular components for the generation of Ca2+ waves. The simulations also suggested the role of membrane potential dynamics in regulating Ca2+ wave velocity. The multi-cellular vessel segment model examined the underlying mechanisms for the intercellular synchronization of spontaneous oscillatory Ca2+ waves in individual SMC. ^ From local subcellular events to integrated macro-scale behavior at the vessel level, the developed multi-scale models captured basic features of vascular Ca2+ signaling and provide insights for their physiological relevance. The models provide a theoretical framework for assisting investigations on the regulation of vascular tone in health and disease.^