987 resultados para AISI 1010


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project was originated from the national aircraft industry requirements to reduce the use of coated materials with electroplated chromium or cadmium that produce waste, which is harmful to health or the environment. The selected material is a Custom 465 stainless steel used in the aeronautical field due to its high mechanical strength. Considering the load sustained by the wheel axis of the landing gear, the Custom 465 is tested in axial fatigue. The objective is to compare the behavior of the Custom 465 with plated AISI 4340 steel coated with cadmium. X-ray diffraction method was used to determine the residual stress field induced by shot peening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Experimental investigations were carried out using a Nd:YAG laser operating in pulsed mode for welding a lap joint between thin foil and thick sheet. The pulse energy was varied from 1.5 to 3.0 J at increments of 0.25 J with a 4 ms pulse duration. The base material used for this study was AISI 316L foils with 100 mu m thickness and sheet with 3.0 mm thickness. The welds were analysed by optical and electronic microscopy, tensile shear tests and micro hardness. The results indicate that pulse energy control is of considerable importance to join thin foil and thick sheet with good quality. The ultimate tensile strength of the welded joints increased at first and then decreased as the pulse energy increased. The process appeared to be very sensitive to the gap between couples. Large voids delimited by the molten zone boundary were observed in joints welded with high pulse energy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to value the possibility to join, for pulsed Nd:YAG laser welding, thin foils lap joints for sealing components in corrosive environment. Experimental investigations were carried out using a pulsed neodymium: yttrium aluminum garnet laser weld to examine the influence of the pulse energy in the characteristics of the weld fillet. The pulse energy was varied from 1.0 to 2.5 J at increments of 0.25 J with a 4 ms pulse duration. The base materials used for this study were AISI 316L stainless steel and Ni-based alloys foils with 100 mu m thickness. The welds were analyzed by electronic and optical microscopy, tensile shear tests and micro hardness. The results indicate that pulse energy control is of considerable importance to thin foil weld quality because it can generate good mechanical properties and reduce discontinuities in weld joints. The ultimate tensile strength of the welded joints increased at first and then decreased as the pulse energy increased. In all the specimens, fracture occurred in the top foil heat-affected zone next to the fusion line. The microhardness was almost uniform across the parent metal, HAZ and weld metal. A slight increase in the fusion zone and heat-affected zone compared to those measured in the base metal was observed. This is related to the microstructural refinement in the fusion zone, induced by rapid cooling of the laser welding. The process appeared to be very sensitive to the gap between couples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: This is a position paper from the 2nd International Bone Research Association (IBRA) Symposium for Condylar Fracture Osteosynthesis 2012 was held at Marseille, succeeding the first congress in Strasbourg, France, in 2007. The goal of this IBRA symposium and this paper was to evaluate current trends and potential changes of treatment strategies for mandibular condylar fractures, which remain controversial over the past decades.Methods: Using a cross-sectional study design, we enrolled the consensus based on the panel of experts and participants in the IBRA Symposium 2012. The outcomes of interest were the panel and electronic votes on management of condylar base, neck and head fractures, and panel votes on endoscopic and paediatric condylar fractures. Appropriate descriptive and univariate statistics were used.Results: The consensus derived from 14 experts and 41 participant surgeons, using 12 case scenarios and 27 statements. The experts and participants had similar decision on the treatment of condylar base, neck and head fractures, as well as similar opinion on complications of condylar fracture osteosynthesis. They had a parallel agreement on using open reduction with internal fixation (ORIF) as treatment of choice for condylar base and neck fractures in adults. Endoscopic approaches should be considered for selected cases, such as condylar base fractures with lateral displacement. There was also a growing tendency to perform ORIF in condylar head fractures. The experts also agreed to treat children (> 12 years old) in the same way as adults and to consider open reduction in severely displaced and dislocated fractures even in younger children. Nevertheless, non-surgical treatment should be the first choice for children <6 years of age. The decision to perform surgery in children was based on factors influencing facial growth, appropriate age for ORIF, and disagreement to use resorbable materials in children.Conclusions: The experts and participating surgeons had comparable opinion on management of condylar fractures and complications of ORIF. Compared to the first Condylar Fracture Symposium 2007 in Strasbourg, ORIF may now be considered as the gold standard for both condylar base and neck fractures with displacement and dislocation. Although ORIF in condylar head fractures in adults and condylar fractures in children with mixed dentition is highly recommended, but this recommendation requires further investigations. (C) 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The flash photolysis (lambda = 266 nm) of four alpha -brominated omicron -xylenes in apolar solvents gives two transients characterized, depending on parent compound substitution, as either monoradicals or carbenes, and quinodimethanes. alpha -Bromomethylbenzyl radical is characterized and the novel species alpha,alpha'-dibromo-omicron -xylylene and omicron-(alpha,alpha -dibromomethyl)benzyl carbene are described for the first time. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This project was originated from the national aircraft industry requirements to reduce the use of coated materials with electroplated chromium or cadmium that produce waste, which is harmful to health or the environment. The selected material is a Custom 465 stainless steel used in the aeronautical field due to its high mechanical strength. Considering the load sustained by the wheel axis of the landing gear, the Custom 465 was tested in axial fatigue. The objective is to compare the behavior of the Custom 465 stainless steel with plated AISI 4340 steel coated with cadmium. Fractographic analysis was conducted using scanning electron microscopy. X-ray diffraction method was used to determine the residual stress field induced by shot peening.