994 resultados para volume algorithm
Resumo:
The results suggest that the two variables studied are significant and that they may be independently optimized. The material of the sample holder interferes with the incineration process only due to the amount of heat transfered. The sample holder volume aids diffusion of the atmosphere to the honey sample, minimizing the foaming effect. According to the results, for the thermogravimetric analysis of ash content in honey, sample holders of platinum or alumina of 150 µL are indicated.
Resumo:
This thesis concentrates on developing a practical local approach methodology based on micro mechanical models for the analysis of ductile fracture of welded joints. Two major problems involved in the local approach, namely the dilational constitutive relation reflecting the softening behaviour of material, and the failure criterion associated with the constitutive equation, have been studied in detail. Firstly, considerable efforts were made on the numerical integration and computer implementation for the non trivial dilational Gurson Tvergaard model. Considering the weaknesses of the widely used Euler forward integration algorithms, a family of generalized mid point algorithms is proposed for the Gurson Tvergaard model. Correspondingly, based on the decomposition of stresses into hydrostatic and deviatoric parts, an explicit seven parameter expression for the consistent tangent moduli of the algorithms is presented. This explicit formula avoids any matrix inversion during numerical iteration and thus greatly facilitates the computer implementation of the algorithms and increase the efficiency of the code. The accuracy of the proposed algorithms and other conventional algorithms has been assessed in a systematic manner in order to highlight the best algorithm for this study. The accurate and efficient performance of present finite element implementation of the proposed algorithms has been demonstrated by various numerical examples. It has been found that the true mid point algorithm (a = 0.5) is the most accurate one when the deviatoric strain increment is radial to the yield surface and it is very important to use the consistent tangent moduli in the Newton iteration procedure. Secondly, an assessment of the consistency of current local failure criteria for ductile fracture, the critical void growth criterion, the constant critical void volume fraction criterion and Thomason's plastic limit load failure criterion, has been made. Significant differences in the predictions of ductility by the three criteria were found. By assuming the void grows spherically and using the void volume fraction from the Gurson Tvergaard model to calculate the current void matrix geometry, Thomason's failure criterion has been modified and a new failure criterion for the Gurson Tvergaard model is presented. Comparison with Koplik and Needleman's finite element results shows that the new failure criterion is fairly accurate indeed. A novel feature of the new failure criterion is that a mechanism for void coalescence is incorporated into the constitutive model. Hence the material failure is a natural result of the development of macroscopic plastic flow and the microscopic internal necking mechanism. By the new failure criterion, the critical void volume fraction is not a material constant and the initial void volume fraction and/or void nucleation parameters essentially control the material failure. This feature is very desirable and makes the numerical calibration of void nucleation parameters(s) possible and physically sound. Thirdly, a local approach methodology based on the above two major contributions has been built up in ABAQUS via the user material subroutine UMAT and applied to welded T joints. By using the void nucleation parameters calibrated from simple smooth and notched specimens, it was found that the fracture behaviour of the welded T joints can be well predicted using present methodology. This application has shown how the damage parameters of both base material and heat affected zone (HAZ) material can be obtained in a step by step manner and how useful and capable the local approach methodology is in the analysis of fracture behaviour and crack development as well as structural integrity assessment of practical problems where non homogeneous materials are involved. Finally, a procedure for the possible engineering application of the present methodology is suggested and discussed.
Resumo:
We present a participant study that compares biological data exploration tasks using volume renderings of laser confocal microscopy data across three environments that vary in level of immersion: a desktop, fishtank, and cave system. For the tasks, data, and visualization approach used in our study, we found that subjects qualitatively preferred and quantitatively performed better in the cave compared with the fishtank and desktop. Subjects performed real-world biological data analysis tasks that emphasized understanding spatial relationships including characterizing the general features in a volume, identifying colocated features, and reporting geometric relationships such as whether clusters of cells were coplanar. After analyzing data in each environment, subjects were asked to choose which environment they wanted to analyze additional data sets in - subjects uniformly selected the cave environment.
Resumo:
Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method
Resumo:
Analytical solutions of a cubic equation with real coefficients are established using the Cardano method. The method is first applied to simple third order equation. Calculation of volume in the van der Waals equation of state is afterwards established. These results are exemplified to calculate the volumes below and above critical temperatures. Analytical and numerical values for the compressibility factor are presented as a function of the pressure. As a final example, coexistence volumes in the liquid-vapor equilibrium are calculated. The Cardano approach is very simple to apply, requiring only elementary operations, indicating an attractive method to be used in teaching elementary thermodynamics.
Resumo:
An undergraduate physical chemistry experiment based on the drop counting method for surface tension measurements is proposed to demonstrate adsorption isotherms of binary aqueous solutions of ethanol, n-propanol, and n-butanol. Excess surface is obtained by the derivative of surface tension taken with respect to alcohol activity, after this activity calculation using van Laar equation. Laboratory class contents are surface tension, excess surface, percolation of hydrogen bonds, micelle, activity, and ideal solution.
Estimation of surface area and pore volume of activated carbons by methylene blue and iodine numbers
Resumo:
Data of methylene blue number and iodine number of activated carbons samples were calibrated against the respective surface area, micropore volume and total pore volume using multiple regression. The models obtained from the calibrations were used in predicting these physical properties of a test group of activated carbon samples produced from several raw materials. In all cases, the predicted values were in good agreement with the expected values. The method allows extracting more information from the methylene blue and iodine adsorption studies than normally obtained with this type of material.
Resumo:
Extraction/concentration is a crucial step for the analysis of organic compounds at trace level concentrations and dispersed in complex matrices. Solid-phase extraction (SPE) is one of the techniques used for this purpose. In this work, a low cost apparatus for SPE was developed that uses nitrogen under positive pressure and ensures the maintenance of the sample flow, while also allows the simultaneous extraction of different samples without cross-contamination and sample contact with plastic materials. For the system set up, easily accessible materials were used such as hypodermic needles, stainless steel tubes, rubber stoppers, and 3-way valves from serum delivery apparatus.
Resumo:
In the Russian Wholesale Market, electricity and capacity are traded separately. Capacity is a special good, the sale of which obliges suppliers to keep their generating equipment ready to produce the quantity of electricity indicated by the System Operator. The purpose of the formation of capacity trading was the maintenance of reliable and uninterrupted delivery of electricity in the wholesale market. The price of capacity reflects constant investments in construction, modernization and maintenance of power plants. So, the capacity sale creates favorable conditions to attract investments in the energy sector because it guarantees the investor that his investments will be returned.
Resumo:
O controle químico do agente causal da mancha-preta-dos-citros (MPC) tem merecido destaque pelo excessivo número de pulverizações, elevando sobremaneira os custos de produção na citricultura. A busca por melhorias na eficiência das pulverizações e reduções na quantidade dos produtos fitossanitários já tem sido realizada, mas os resultados dessa prática ainda não são consistentes para que possa ser aplicado em escala comercial. Sendo assim, essa pesquisa objetivou avaliar a interferência da redução no volume de aplicação, sobre o controle químico da mancha preta em frutos cítricos. O experimento foi conduzido em pomar comercial com plantas de 16 anos de idade, da variedade Valência durante o ano agrícola 2007. Os tratamentos consistiram de três volumes de calda, 3,5; 4,5 e 8,5 L planta-1, aplicados por pulverizador de jato transportado Arbus 2000/Export, com ramal especial de bicos, utilizando-se fungicidas e períodos recomendados para o controle da doença em um total de quatro pulverizações e mais um tratamento testemunha (sem pulverização). As avaliações de incidência e severidade da doença ocorreram através de escala visual diagramática de notas em duas épocas (pré-colheita e colheita), em três alturas (baixo, médio e alto) da planta e mais três setores horizontais (entrada, frontal e saída) em dois lados da planta. Os frutos caídos foram contados quinzenalmente, em plantas previamente selecionadas, do início da maturação até a colheita com a quantificação da produção (kg planta-1). A incidência e severidade da doença foram menores quando as pulverizações foram realizadas com 8,5 L planta-1 na primeira época de avaliação (pré-colheita), porém na colheita, não houve diferenças entre os mesmos parâmetros, quando pulverizados 4,5 ou 8,5 L planta-1. Nenhum tratamento reduziu a doença no setor alto da planta, em comparação a testemunha. Os setores da planta com os frutos mais expostos aos raios solares, lado direito e alto da planta, apresentaram maior incidência e severidade da doença. A redução no volume de 8,5 para 4,5 L planta-1 pode ser praticada na citricultura sem prejuízo do nível de controle da MPC.