961 resultados para user experience measurement
Resumo:
OBJECTIVE: To evaluate the initial clinical experience with the Helex septal occluder for percutaneous closure of atrial septal defects. METHODS: Ten patients underwent the procedure, 7 patients with ostium secundum atrial septal defects (ASD) with hemodynamic repercussions and 3 patients with pervious foramen ovale (PFO) and a history of stroke. Mean age was 33.8 years and mean weight was 55.4 kg. Mean diameter by transesophageal echocardiography and mean stretched ASD diameter were 11.33 ± 3.3mm, and 15.2 ± 3.8mm, respectively. The Qp/Qs ratio was 1.9 ± 0.3 in patients with ASD. RESULTS: Eleven occluders were placed because a patient with 2 holes needed 2 devices. It was necessary to retrieve and replace 4 devices in 3 patients. We observed immediate residual shunt (< 2mm) in 4 patients with ASD, and in those with patent foramen ovale total occlusion of the defect occurred. No complications were noted, and all patients were discharged on the following day. After 1 month, 2 patients with ASD experienced trivial residual shunts (1mm). In 1 patient, we observed mild prolapse in the proximal disk in the right atrium, without consequences. CONCLUSION: The Helex septal occluder was safe and effective for occluding small to moderate atrial septal defects. Because the implantation technique is demanding, it requires specific training of the operator. Even so, small technical failures may occur in the beginning of the learning curve, but they do not involve patient safety.
Resumo:
El presente proyecto de investigación se orienta a analizar la institución del juicio por jurados, considerada como un punto estratégico para la observación de los procesos de cambio que recorren la cultura jurídica en Argentina. Frente a las múltiples transformaciones y a los intensos procesos de reestructuración de las relaciones sociales observados en el contexto latinoamericano y especialmente en Argentina, la necesidad de reconstruir la legitimidad de los jueces ante la opinión pública se ha vuelto impostergable, y el recurso a la participación popular en el campo judicial aparece como un instrumento útil para ello. Analizar la efectividad de esta estrategia para la legitimación del poder judicial es uno de los objetivos del presente proyecto de investigación. Abordar dicho objetivo implica, indagar en la relación entre la administración de justicia y diferentes actores sociales, especialmente los miembros de la profesión jurídica y la opinión pública.Se explora igualmente la contradicción entre el hecho de que esta institución, nacida para atenuar la dureza de los castigos, se ha implementado recientemente en la provincia de Córdoba en la situación inversa. El modo en que la tensión entre el espíritu garantista de los jueces y la demanda de castigos de los ciudadanos comunes se manejará en la práctica de los juicios por jurado, y su incidencia en el éxito de las estrategias legitimadoras del poder judicial, aparece como una cuestión relevante para el análisis que se propone. Con la utilización de diferentes fuentes de información cuantitativas y cualitativas, se espera que el análisis de la implementación del juicio penal con jurados populares en la provincia de Córdoba propuesto en el presente proyecto, contribuya a documentar los niveles de articulación entre la cultura jurídica interna y externa.
Resumo:
Zugl.: Magdeburg, Univ., Fak. für Informatik, Diss., 2011
Resumo:
Software engineering, software measurement, software process engineering, capability, maturity
Resumo:
Social intelligence
Resumo:
Background:Primary graft dysfunction is the main cause of early mortality after heart transplantation. Mechanical circulatory support has been used to treat this syndrome.Objective:Describe the experience with extracorporeal membrane oxygenation to treat post-transplant primary cardiac graft dysfunction.Methods:Between January 2007 and December 2013, a total of 71 orthotopic heart transplantations were performed in patients with advanced heart failure. Eleven (15.5%) of these patients who presented primary graft dysfunction constituted the population of this study. Primary graft dysfunction manifested in our population as failure to wean from cardiopulmonary bypass in six (54.5%) patients, severe hemodynamic instability in the immediate postoperative period with severe cardiac dysfunction in three (27.3%), and cardiac arrest (18.2%). The average ischemia time was 151 ± 82 minutes. Once the diagnosis of primary graft dysfunction was established, we installed a mechanical circulatory support to stabilize the severe hemodynamic condition of the patients and followed their progression longitudinally.Results:The average duration of extracorporeal membrane oxygenation support was 76 ± 47.4 hours (range 32 to 144 hours). Weaning with cardiac recovery was successful in nine (81.8%) patients. However, two patients who presented cardiac recovery did not survive to hospital discharge.Conclusion:Mechanical circulatory support with central extracorporeal membrane oxygenation promoted cardiac recovery within a few days in most patients.
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2009
Resumo:
Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.
Resumo:
Magdeburg, Univ., Fak. für Informatik, Diss., 2010
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2011
Resumo:
Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012
Resumo:
An appropriate assessment of end-to-end network performance presumes highly efficient time tracking and measurement with precise time control of the stopping and resuming of program operation. In this paper, a novel approach to solving the problems of highly efficient and precise time measurements on PC-platforms and on ARM-architectures is proposed. A new unified High Performance Timer and a corresponding software library offer a unified interface to the known time counters and automatically identify the fastest and most reliable time source, available in the user space of a computing system. The research is focused on developing an approach of unified time acquisition from the PC hardware and accordingly substituting the common way of getting the time value through Linux system calls. The presented approach provides a much faster means of obtaining the time values with a nanosecond precision than by using conventional means. Moreover, it is capable of handling the sequential time value, precise sleep functions and process resuming. This ability means the reduction of wasting computer resources during the execution of a sleeping process from 100% (busy-wait) to 1-1.5%, whereas the benefits of very accurate process resuming times on long waits are maintained.
Resumo:
Magdeburg, Univ., Fak. für Elektrotechnik und Informationstechnik, Diss., 2013
Resumo:
... ist es nicht möglich, die in dieser Arbeit identifizierten offenen Fragen restlos zu klären. Die Erweiterung der puren akustischen Emotionserkennung durch Berücksichtigung von anderen Modalitäten, Sprechercharakteristiken, Feedbacksignalen und Persönlichkeitsmerkmalen erlaubt es jedoch, länger andauernde natürliche Interaktionen zu untersuchen und dialogkritische Situationen zu erkennen. Technische Systeme, die diese erweiterte Emotionserkennung nutzen, passen sich an ihren Nutzer an und werden so zu seinem Begleiter und letztendlich zu seinem Companion.