984 resultados para stereoselective molecular recognition


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exogenous agents correlated with hepatocellular carcinoma (HCC) have been identified and well characterized. These agents, including the different viruses that cause chronic hepatitis and cirrhosis, can lead to regenerative nodules and dysplastic nodules/adenomatous hyperplasia. These conditions associated with several molecular alterations of hepatocyte ultimately culminate in hepatocellular carcinoma. Recently, there has been a great progress in the identification of somatic and germinative mutations that may be correlated with the development of HCC, justifying a review on the subject. Hence, the factors involved in the process of hepatic carcinogenesis, such as infection by the hepatitis B and C viruses, with a special focus in the molecular alterations described in recent years are discussed herein, pointing out areas potentially relevant for clinical development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis for the Master degree in Structural and Functional Biochemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phenotypic and genotypic characteristics of Salmonella Typhi were studied in 30 strains, isolated in different years, from some areas in Brazil. Conventional typing methods were performed by biochemical tests, Vi phage-typing scheme, and antimicrobial susceptibility test. Molecular typing methods were performed by analysis of plasmid DNA and by random amplified polymorphic DNA (RAPD-PCR). For the latter, an optimization step was performed to ensure the reproducibility of the process in genetic characterization of S. Typhi. The predominance of 76.7% of biotype I (xylose +, arabinose -) was noticed in all studied areas. Three phage types were recognized, with prominence for the phage types A (73.3%) and I+IV (23.3%). All the strains were susceptible to the drugs used. However, 36.7% of the strains contained plasmids, with predominance of the 105 Kb plasmid. RAPD was capable of grouping the strains in 8 genotypic patterns using primer 784, in 6, using primer 787 and in 7, using primer 797. Conventional phenotypic typing methods, as well as the DNA plasmid analysis, presented nonsignificant discriminatory power; however, RAPD-PCR analysis showed discriminatory power, reproducibility, easy interpretation and performance, being considered as a promising alternative typing method for S. Typhi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2001, an autochthonous case of dual viremia, resulting from naturally acquired dengue virus DEN-1 and DEN-2 infections was detected during the dengue outbreak that occurred in Barretos, a city with about 105,000 inhabitants in the North region of São Paulo State. Serotype identification was based on virus isolation to C6/36 mosquito cells culture and immunofluorescence assays using type-specific monoclonal antibodies. The double infection was also confirmed by reverse transcriptase polymerase chain reaction (RT-PCR). Comparative analysis of the 240-nucleotide sequences of E/NS1 gene junction region between the genome of DEN-1 and DEN-2 isolates of the corresponding reference Nauru and PR 159S1 strains, respectively, showed some nucleotide differences, mainly silent mutations in the third codon position. Results of maximum likelihood phylogenetic analysis of E/NS1 gene sequences indicated that both genotypes of DEN-1 and DEN-2 viruses recovered from double infection in Barretos belonged to genotypes I and III, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strain typing is a critical tool for molecular epidemiological analysis and can provide important information about the spread of dengue viruses. Here, we performed a molecular characterization of DEN-2 viruses isolated in Brazil during 1990-2000 from geographically and temporally distinct areas in order to investigate the genetic distribution of this serotype circulating in the country. Restriction site-specific polymerase chain reaction (RSS)-PCR presented the same pattern for all 52 Brazilian samples, showing the circulation of just one DEN-2 variant. Phylogenetic analysis using progressive pairwise alignments from 240-nucleotide sequences of the E/NS1 junction in 15 isolates showed that they belong to genotype III (Jamaica genotype).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In São Paulo State, Brazil, the epidemic increase in isolation of Salmonella Enteritidis has been observed since 1994. A total of 105 S. Enteritidis strains (72 from human and 33 from non-human sources) isolated during the period 1975-1995, previously characterized by phage typing, was analyzed by antimicrobial susceptibility, plasmid profile, and ribotyping. Over 70% of the strains were susceptible to all antimicrobial agents tested, however, multiple resistance to antimicrobials was observed among the studied strains, mainly those from hospitalized patients. Phage type 8 (PT-8) was predominant among the strains isolated during the period of 1975-1992, but in the following years, PT-4 was the most frequent phage type identified. Seven different plasmid profiles were detected and 96% of the isolates harbored a plasmid of approximately 36 MDa. Ribotyping discriminated fourteen ribotypes (R1 to R14) among the strains examined. By analysis of dendrogram the strains were included in three groups with similarity level of 60%. The obtained results indicate that, a single ribotype (R11), determined for PT-4 strains isolated from 1993, characterizes the epidemic clone of S. Enteritidis in our region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A. lumbricoides has been associated to the ABO System by various authors. The objective was to detect ABO System epitopes in A. lumbricoides of groups O, A, B and AB patients. 28 adult parasites were obtained from children to be used as assay material. The patients ABO blood groups were determined. Extracts of A. lumbricoides [AE] were prepared by surgical remotion of the cuticle and refrigerated mechanical rupture. Agglutination Inhibition (AI) and Hemoagglutination Kinetics (HK) tests were used with the [AE]. Of the 28 [AE], eight belonged to O group patients, 15 to A group, three to B group and the remaining two to AB children. The AI Test showed A epitopes in two [AE] of group A patients and B epitopes in two [AE] of group B patients. The HK Test showed B antigenic determiners in two [AE] of group B patients and in two [AE] of group AB patients as well as A antigenic determiners in one [AE] of A group patient. Of the 28 [AE] studied in both tests B epitopes were detected in all [AE] from B and AB patients and A epitopes in three of the 15 [AE] of group A patients. The experiments carried out suggest that A. lumbricoides might absorb A and B antigens from the host, and/or modify the cuticular carbohydrates expression as a kind of antigenic mimicry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biomimetics has paved the way toward new materials and technologies inspired in Nature. Biomolecules and their supramolecular organization have today a leading role in biomimetics, benefiting from the recent advances in nanotechnology. The production of biomimetic materials may be however a difficult task, because Nature does it very well. The use of several building blocks assembled in bottom-up arrangement is without doubt at the core of this process. Such building blocks include different molecules or molecular arrangements, of synthetic or natural origin, such as amino acids, lipids, carbohydrates, nucleic acids, carbon allotropes, dendrimers, or organosilanes, among others. The most common approaches to produce synthetic biomimetic materials are reported herein, with special emphasis to building blocks and their supramolecular arrangement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel artificial antibody for troponin T (TnT) was synthesized by molecular imprint (MI) on the surface of multiwalled carbon nanotubes (MWCNT). This was done by attaching TnT to the MWCNT surface, and filling the vacant spaces by polymerizing under mild conditions acrylamide (monomer) in N,N′-methylenebisacrylamide (cross-linker) and ammonium persulphate (initiator). After removing the template, the obtained biomaterial was able to rebind TnT and discriminate it among other interfering species. Stereochemical recognition of TnT was confirmed by the non-rebinding ability displayed by non-imprinted (NI) materials, obtained by imprinting without a template. SEM and FTIR analysis confirmed the surface modification of the MWCNT. The ability of this biomaterial to rebind TnT was confirmed by including it as electroactive compound in a PVC/plasticizer mixture coating a wire of silver, gold or titanium. Anionic slopes of 50 mV decade−1 were obtained for the gold wire coated with MI-based membranes dipped in HEPES buffer of pH 7. The limit of detection was 0.16 μg mL−1. Neither the NI-MWCNT nor the MWCNT showed the ability to recognize the template. Good selectivity was observed against creatinine, sucrose, fructose, myoglobin, sodium glutamate, thiamine and urea. The sensor was tested successfully on serum samples. It is expected that this work opens new horizons on the design of new artificial antibodies for complex protein structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a result of the stressful conditions in aquaculture facilities there is a high risk of bacterial infections among cultured fish. Chlortetracycline (CTC) is one of the antimicrobials used to solve this problem. It is a broad spectrum antibacterial active against a wide range of Gram-positive and Gram-negative bacteria. Numerous analytical methods for screening, identifying, and quantifying CTC in animal products have been developed over the years. An alternative and advantageous method should rely on expeditious and efficient procedures providing highly specific and sensitive measurements in food samples. Ion-selective electrodes (ISEs) could meet these criteria. The only ISE reported in literature for this purpose used traditional electro-active materials. A selectivity enhancement could however be achieved after improving the analyte recognition by molecularly imprinted polymers (MIPs). Several MIP particles were synthesized and used as electro-active materials. ISEs based in methacrylic acid monomers showed the best analytical performance according to slope (62.5 and 68.6 mV/decade) and detection limit (4.1 × 10−5 and 5.5 × 10−5 mol L−1). The electrodes displayed good selectivity. The ISEs are not affected by pH changes ranging from 2.5 to 13. The sensors were successfully applied to the analysis of serum, urine and fish samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The indiscriminate use of antibiotics in food-producing animals has received increasing attention as a contributory factor in the international emergence of antibiotic-resistant bacteria (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004). Numerous analytical methods for quantifying antibacterial residues in edible animal products have been developed over years (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004; Botsoglou and Fletouris in Handbook of food analysis, residues and other food component analysis, Marcel Dekker, Ghent, 2004). Being Amoxicillin (AMOX) one of those critical veterinary drugs, efforts have been made to develop simple and expeditious methods for its control in food samples. In literature, only one AMOX-selective electrode has been reported so far. In that work, phosphotungstate:amoxycillinium ion exchanger was used as electroactive material (Shoukry et al. in Electroanalysis 6:914–917, 1994). Designing new materials based on molecularly imprinted polymers (MIPs) which are complementary to the size and charge of AMOX could lead to very selective interactions, thus enhancing the selectivity of the sensing unit. AMOX-selective electrodes used imprinted polymers as electroactive materials having AMOX as target molecule to design a biomimetic imprinted cavity. Poly(vinyl chloride), sensors of methacrylic acid displayed Nernstian slopes (60.7 mV/decade) and low detection limits (2.9 × 10−5 mol/L). The potentiometric responses were not affected by pH within 4–5 and showed good selectivity. The electrodes were applied successfully to the analysis of real samples.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Molecular Biology