958 resultados para pixel detector
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-08
Resumo:
An 18 module Ceienkov detector with a total sensitive area of 2.3 m2 having silica aerogel as radiator is being tested in a particle beam at CERN PS. The modules having a sensitive area of 23 X 55 cm2 give typically a Cerenkov signal for (3= 1 particles of 12 photoelectrons for silica aerogel of refractive index 1.03 and a thickness of 15 cm. © 1981 IOP Publishing Ltd.
Resumo:
Background - Image blurring in Full Field Digital Mammography (FFDM) is reported to be a problem within many UK breast screening units resulting in significant proportion of technical repeats/recalls. Our study investigates monitors of differing pixel resolution, and whether there is a difference in blurring detection between a 2.3 MP technical review monitor and a 5MP standard reporting monitor. Methods - Simulation software was created to induce different magnitudes of blur on 20 artifact free FFDM screening images. 120 blurred and non-blurred images were randomized and displayed on the 2.3 and 5MP monitors; they were reviewed by 28 trained observers. Monitors were calibrated to the DICOM Grayscale Standard Display Function. T-test was used to determine whether significant differences exist in blurring detection between the monitors. Results - The blurring detection rate on the 2.3MP monitor for 0.2, 0.4, 0.6, 0.8 and 1 mm blur was 46, 59, 66, 77and 78% respectively; and on the 5MP monitor 44, 70, 83 , 96 and 98%. All the non-motion images were identified correctly. A statistical difference (p <0.01) in the blurring detection rate between the two monitors was demonstrated. Conclusions - Given the results of this study and knowing that monitors as low as 1 MP are used in clinical practice, we speculate that technical recall/repeat rates because of blurring could be reduced if higher resolution monitors are used for technical review at the time of imaging. Further work is needed to determine monitor minimum specification for visual blurring detection.
Resumo:
This thesis presents the achievements and scientific work conducted using a previously designed and fabricated 64 x 64-pixel ion camera with the use of a 0.35 μm CMOS technology. We used an array of Ion Sensitive Field Effect Transistors (ISFETs) to monitor and measure chemical and biochemical reactions in real time. The area of our observation was a 4.2 x 4.3 mm silicon chip while the actual ISFET array covered an area of 715.8 x 715.8 μm consisting of 4096 ISFET pixels in total with a 1 μm separation space among them. The ion sensitive layer, the locus where all reactions took place was a silicon nitride layer, the final top layer of the austriamicrosystems 0.35 μm CMOS technology used. Our final measurements presented an average sensitivity of 30 mV/pH. With the addition of extra layers we were able to monitor a 65 mV voltage difference during our experiments with glucose and hexokinase, whereas a difference of 85 mV was detected for a similar glucose reaction mentioned in literature, and a 55 mV voltage difference while performing photosynthesis experiments with a biofilm made from cyanobacteria, whereas a voltage difference of 33.7 mV was detected as presented in literature for a similar cyanobacterial species using voltamemtric methods for detection. To monitor our experiments PXIe-6358 measurement cards were used and measurements were controlled by LabVIEW software. The chip was packaged and encapsulated using a PGA-100 chip carrier and a two-component commercial epoxy. Printed circuit board (PCB) has also been previously designed to provide interface between the chip and the measurement cards.
Resumo:
Present the measurement of a rare Standard Model processes, pp →W±γγ for the leptonic decays of the W±. The measurement is made with 19.4 fb−1 of 8 TeV data collected in 2012 by the CMS experiment. The measured cross section is consistent with the Standard Model prediction and has a significance of 2.9σ. Limits are placed on dimension-8 Effective Field Theories of anomalous Quartic Gauge Couplings. The analysis has particularly sensitivity to the fT,0 coupling and a 95% confidence limit is placed at −35.9 < fT,0/Λ4< 36.7 TeV−4. Studies of the pp →Zγγ process are also presented. The Zγγ signal is in strict agreement with the Standard Model and has a significance of 5.9σ.
Resumo:
The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The "hybrid" detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions. (C) 2010 Elsevier B.V All rights reserved.
Resumo:
Dissertação mest. em Imagiologia Médica, Faculdade de Ciências e Tecnologia da Univ. do Algarve, 2006
Resumo:
With recent advances in remote sensing processing technology, it has become more feasible to begin analysis of the enormous historic archive of remotely sensed data. This historical data provides valuable information on a wide variety of topics which can influence the lives of millions of people if processed correctly and in a timely manner. One such field of benefit is that of landslide mapping and inventory. This data provides a historical reference to those who live near high risk areas so future disasters may be avoided. In order to properly map landslides remotely, an optimum method must first be determined. Historically, mapping has been attempted using pixel based methods such as unsupervised and supervised classification. These methods are limited by their ability to only characterize an image spectrally based on single pixel values. This creates a result prone to false positives and often without meaningful objects created. Recently, several reliable methods of Object Oriented Analysis (OOA) have been developed which utilize a full range of spectral, spatial, textural, and contextual parameters to delineate regions of interest. A comparison of these two methods on a historical dataset of the landslide affected city of San Juan La Laguna, Guatemala has proven the benefits of OOA methods over those of unsupervised classification. Overall accuracies of 96.5% and 94.3% and F-score of 84.3% and 77.9% were achieved for OOA and unsupervised classification methods respectively. The greater difference in F-score is a result of the low precision values of unsupervised classification caused by poor false positive removal, the greatest shortcoming of this method.
Resumo:
Analisi sperimentale svolta per valutare come la segnaletica di cantiere, se percepita correttamente, influenza la guida degli utenti che circolano sulla strada interessata da lavorazioni di tipo cantieristico. L'analisi si prefigge anche lo scopo di trovare le soluzioni necessarie per garantire il livello di sicurezza più alto possibile sia per gli utenti che si ritrovano a stretto contatto con il cantiere, che per lavoratori che vi operano.
Resumo:
I semiconduttori organici sono alla base dell'elettronica organica, un campo di ricerca che negli ultimi anni ha coinvolto diversi gruppi di lavoro, sia a livello accademico che industriale. Diversi studi hanno portato all'idea di impiegare materiali di questo tipo come detector di raggi X, sfruttando la loro flessibilità meccanica, la facile fabbricazione di dispositivi su larga area e tramite tecniche a basso costo (es. stampa a getto di inchiostro) e le basse tensioni operative. In questa tesi in particolare si utilizzeranno degli OFET (Organic Field-Effect Transistor) a questo scopo, dimostrando la possibilità amplificare la sensibilità alla radiazione X e di pilotare le prestazioni del detector mediante l'applicazione della tensione all'elettrodo di gate. Presenteremo quindi uno studio sperimentale atto a caratterizzare elettricamente dei transistor realizzati con differenti semiconduttori organici, prima, durante e dopo l'esposizione a raggi X, in maniera da stimarne la sensibilità, le proprietà di conduzione intrinseche e la resistenza all'invecchiamento.