942 resultados para partial signatures
Resumo:
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 με) and point D the highest (442.77 με). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.
Resumo:
Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.
Resumo:
Aim: To investigate the association between gender and type of cleft with hypodontia and to verify if the presence of the cleft interferes with hypodontia of one or more type of teeth in patients with ectodermal dysplasia attending the Hospital for Rehabilitation of Craniofacial Anomalies (HRCA), University of Sγo Paulo (USP). Materials and Methods: Panoramic radiographs of 54 patients of both genders (29 males, 25 females), from the files of the oral radiology sector of HRCA/USP, presenting with ectodermal dysplasia and cleft lip and/or palate were evaluated by radiographic observation of hypodontia of one or more types of teeth. Statistical Analysis: We performed descriptive statistics and statistical analysis by Fisher test. Results: Hypodontia was observed in 50% of females and 50.88% of males; 50% for cleft palate and 50.59% for complete cleft lip and palate. Only 22.22% of patients with cleft palate and 6.67% with complete cleft lip and palate presented with hypodontia of one type of teeth, whereas 77.78% of cases with cleft palate and 93.33% with complete cleft lip and palate displayed hypodontia of more than one type of teeth. Conclusion: Based on the present methodology, there were no statistically significant differences in hypodontia of one or more types of teeth between genders or types of cleft.
Resumo:
Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.
Genomic Signatures Predict Poor Outcome in Undifferentiated Pleomorphic Sarcomas and Leiomyosarcomas
Resumo:
Undifferentiated high-grade pleomorphic sarcomas (UPSs) display aggressive clinical behavior and frequently develop local recurrence and distant metastasis. Because these sarcomas often share similar morphological patterns with other tumors, particularly leiomyosarcomas (LMSs), classification by exclusion is frequently used. In this study, array-based comparative genomic hybridization (array CGH) was used to analyze 20 UPS and 17 LMS samples from untreated patients. The LMS samples presented a lower frequency of genomic alterations compared with the UPS samples. The most frequently altered UPS regions involved gains at 20q13.33 and 7q22.1 and losses at 3p26.3. Gains at 8q24.3 and 19q13.12 and losses at 9p21.3 were frequently detected in the LMS samples. Of these regions, gains at 1q21.3, 11q12.2-q12.3, 16p11.2, and 19q13.12 were significantly associated with reduced overall survival times in LMS patients. A multivariate analysis revealed that gains at 1q21.3 were an independent prognostic marker of shorter survival times in LMS patients (HR = 13.76; P = 0.019). Although the copy number profiles of the UPS and LMS samples could not be distinguished using unsupervised hierarchical clustering analysis, one of the three clusters presented cases associated with poor prognostic outcome (P = 0.022). A relative copy number analysis for the ARNT, SLC27A3, and PBXIP1 genes was performed using quantitative real-time PCR in 11 LMS and 16 UPS samples. Gains at 1q21-q22 were observed in both tumor types, particularly in the UPS samples. These findings provide strong evidence for the existence of a genomic signature to predict poor outcome in a subset of UPS and LMS patients. © 2013 Silveira et al.
Resumo:
This study characterised the psychrotrophic genotypes and phenotypes behaviour of 63 strains of Bacillus cereus sensu stricto isolated from dairy products. The presence of the cspA gene signature and the 16S rDNA mesophilic and/or psychrotrophic specific signatures was evaluated. Among the strains, 25 (39.7%) had the cspA gene signature, 38 (60.3%) had both mesophilic and psychrotrophic 16S rDNA signatures, 24 (38.1%) had only mesophilic and one exhibited only psychrotrophic. No strain grew at 7 °C. The results indicate that the presence of psychrotrophic signatures for cspA gene or the 16S rDNA did not ensure a psychrotrophic behaviour on a B. cereus phenotype. © 2013 Society of Dairy Technology.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
ABSTRACT: The eastern border of the Transition Subdomain of the Carajás Province is constituteddominantly of Archean tonalite-trondhjemite-granodiorite (TTG). Deformed monzogranites, similar to the Planalto granite suite, and metagabbros inserted in association mafic-enderbitic also occur. Paleoproterozoic isotropic granites and mafic dykes devoid of significant deformation crosscut the Archean lithologies. The TTGs are exposed as blocks or as flat outcrops in areas of low relief and commonly include quartz-diorite enclaves. The TTG rocks display gray colour and are generally medium-grained, showing compositional banding or, sometimes, homogeneous aspect. They show commonly a NW-SW to E-W trending foliation with vertical to subvertical dips and were submitted to NE-SW stress. Locally, it was identified a NE-SW foliation transposed to E-W along shear zones. In some instances, they exhibit mylonitic to protomilonitics features, registered in the oval form of plagioclase porphyroclasts or boudinated leucogranitics veins. Two petrographic varieties are recognized for this association: biotite-trondjhemite and subordinate biotite-granodiorites, both have similar mineralogical and textural aspects and are characterized by a poorly preserved igneous texture, partially overwritten by an intense recrystallization. EDS analyses revealed that the plagioclase is a calcic oligoclase (An27-19), with Or ranging from 0.6 - 2.3%. The biotites are ferromagnesian, with dominance of Fe over Mg (Fe / [Fe + Mg] ranging from 0.54 to 0.59) and the analyzed epidote presents pistacite contents ranging from 23 to 27.6 % and plot mostly in the range of magmatic epidotes. The trondhjemite shows all typical characteristics of Archean TTG suites. They have high La/Yb and Sr/Y ratios, suggesting they were derived from the partial melting of garnet amphibolite sources at high pressures (ca. 1.5 GPa) or, at least, that their magmatic evolution was controlled by the fractionation of garnet and possibly amphibole, without significant influence of plagioclase. The studied TTGs show similarities with Mariazinha tonalite and Mogno trondjemite, of the Rio Maria Domain, Colorado trondhjemite and, in at a lesser degree, to the Rio Verde trondhjemite, of the Carajás Domain. The granodiorites display a calc-alkaline signature and shows LILE enrichment, specifically K2O, Rb and Ba, when compared to the trondhjemites, but still preserving some geochemical features of the TTG. The geochemical data indicate that the trondhjemite and granodiorite are not related by fractional crystallization. An origin of the granodiorite by partial melting of the TTG rocks is also discarded. The granodiorite could, however, result of contamination of TTG magmas by lithosphere metasomatism or assimilation of sediments from subducted oceanic crust along trondhjemite liquid genesis. In the eastern portion of the mapped area, it was identified a small, E-W trending granite stock clearly controlled by shear zones. The rocks have mylonitic textures, characterized by ovoid-shaped feldspar porphyroclasts, wrapped by recrystallized quartz and mica. These granitic rocks have geochemical signatures of reduced A-type granites and are similar to the Planalto granite suite. Boulders of mafic rocks crop out locally in the northern portion of the area. These rocks show a dominant granoblastic texture, and are mainly composed of amphibole and plagioclase, with subordinate biotite and quartz. In the northern part of the mapped area, it was identified a body of isotropic granite without significant deformation and showing locally rapakivi textures. This granitic pluton was correlated to the Paleoproterozoic A-type granites, represented in the Carajás Domain by the Serra dos Carajás suite and Rio Branco Granite. These granites were not studied in detail. The geological and geochemical aspects shown by the Archean granitoids identified in the eastern part of the Transition Subdomain implies in the existence of significant TTG rocks in the Transition Subdomain. This reinforces the hypothesis that the Transition Subdomain could represent an extension of the Rio Maria Domain, but affected by crustal reworking events in the Neoarchean.
Resumo:
This study aimed at evaluating the effectiveness of partial use of anterior repositioning appliances in the management of TMJ pain and dysfunction when compared to stabilization splints and a control group in a one-year follow-up. Sample was initially constituted by 60 patients, randomly divided into three groups: I- stabilization splints, II- repositioning splints and III- no treatment. The whole sample was evaluated by means of TMJ and muscle palpation, mandibular AROM, analysis of occlusal contacts, joint sounds inspection and Visual Analogue Scale (VAS) for one year; 52 patients composed the final sample. A significant (after 15 days) improvement in pain report (VAS) and palpation index was found for group II (p≤0.01). The occurrence of occlusal alterations as posterior open bite or gross interferences after the splint therapy and increased muscle tenderness were not problems in this study. Similar results in joint noises reduction were observed for the entire sample. It was concluded that controlled partial use of repositioning splints is a beneficial tool in the management of intra-articular pain and dysfunction, with no risks of irreversible occlusal changes.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Background. Despite being functional and having aesthetic benefits, the acceptance of patients regarding the use of removable partial dentures (RPDs) has been low. In part, this is due to the deleterious effects that causes discomfort to the patient. Success depends not only on the care expended by the patient, including daily care and oral hygiene, but also on common goals set by their professional and clinical staff, aiming beyond aesthetics, to incorporate issues of functionality and the well-being of patients. Methods and results. For rehabilitation treatment with RPDs to reach the desired level of success without damaging the support structure, all the steps (diagnose, cavity preparation, adaptation of the metal structures, functional of distal extension and posterior follow-up) in the rehabilitative treatment should be carefully developed. A literature review was carried out, searching through MEDLINE (PubMed) articles published between 1965 and December 2012 including clinical trials and reviews about the use of RPDs. Conclusions. This study describes factors that lead to failures and complications in oral rehabilitation through the use of RPDs and suggests possible solutions.
Resumo:
A number of studies have demonstrated that simple elastic network models can reproduce experimental B-factors, providing insights into the structure-function properties of proteins. Here, we report a study on how to improve an elastic network model and explore its performance by predicting the experimental B-factors. Elastic network models are built on the experimental C coordinates, and they only take the pairs of C atoms within a given cutoff distance r(c) into account. These models describe the interactions by elastic springs with the same force constant. We have developed a method based on numerical simulations with a simple coarse-grained force field, to attribute weights to these spring constants. This method considers the time that two C atoms remain connected in the network during partial unfolding, establishing a means of measuring the strength of each link. We examined two different coarse-grained force fields and explored the computation of these weights by unfolding the native structures. Proteins 2014; 82:119-129. (c) 2013 Wiley Periodicals, Inc.
Resumo:
The current study used strain gauge analysis to perform an in vitro evaluation of the effect of axial and non-axial loading on implant-supported fixed partial prostheses, varying the implant placement configurations and the loading points. Three internal hexagon implants were embedded in the center of each polyurethane block with in-line and offset placements. Microunit abutments were connected to the implants using a torque of 20 N.cm, and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n = 10). Four strain gauges (SGs) were bonded onto the surfaces of the blocks, tangentially to the implants: SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments using a 10-N.cm torque, and axial and non-axial loads of 30 kg were applied at 5 predetermined points. The data obtained from the strain gauge analyses were analyzed statistically through the repeated measures analysis of variance and the Tukey test, with a conventional level of significance of P < 0.05. The results showed a statistically significant difference for the loading point (P = 0.0001), with point E (nonaxial) generating the highest microstrain (327.67 mu epsilon) and point A (axial) generating the smallest microstrain (208.93 mu epsilon). No statistically significant difference was found for implant placement configuration (P = 0.856). It was concluded that the offset implant placement did not reduce the magnitude of microstrain around the implants under axial and non-axial loading conditions, although loading location did influence this magnitude.