856 resultados para geometry features
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The algorithm creates a buffer area around the cartographic features of interest in one of the images and compare it with the other one. During the comparison, the algorithm calculates the number of equals and different points and uses it to calculate the statistical values of the analysis. One calculated statistical value is the correctness, which shows the user the percentage of points that were correctly extracted. Another one is the completeness that shows the percentage of points that really belong to the interest feature. And the third value shows the idea of quality obtained by the extraction method, since that in order to calculate the quality the algorithm uses the correctness and completeness previously calculated. All the performed tests using this algorithm were possible to use the statistical values calculated to represent quantitatively the quality obtained by the extraction method executed. So, it is possible to say that the developed algorithm can be used to analyze extraction methods of cartographic features of interest, since that the results obtained were promising.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In this paper we show that the electronic properties of multi-open dots structures are strongly modified by even smalt changes in their geometries. Our discussion of these effects is done in terms of the interaction among localized states (dot-like) and extended states (channel-like), from which a Fano resonance situation arises.
Resumo:
The thyroid gland was assessed by ultrasound in healthy euthyroid mixed-breed medium size dogs in different age groups. The objective was to verify ultrasonographic imaging patterns in these groups, as well as to identify possible changes in imaging features resulting from ageing. Thirty dogs - 10 young (<1 year), 10 adult and 10 elderly - without clinical signs or history of thyroid gland disease with complete blood count and thyroid function tests within the reference values were evaluated. Each thyroid lobe was examined by ultrasound for shape, size, echogenicity and echotexture. The analysis of echogenicity and echotexture was made by histogram. Thyroid volume was estimated by the equation for ellipsoid (length x width x height) pi/6. The thyroid volume of the young dogs in this study had a tendency to be higher than in adult dogs (P = 0.068) and older dogs (P = 0.120). The height of the thyroid lobe in the longitudinal plane was significantly higher (P = 0.026) in young dogs compared with the other dogs. The echotexture and echogenicity had no significant differences between groups, but the echogenicity was greater in older dogs. The results point out that ultrasound imaging of the thyroid volume is influenced by age in euthyroid dogs.
Resumo:
Reports on the clinical course of mycophenolic acid (MPA)-related colitis in kidney transplant recipients are scarce. This study aimed at assessing MPA-related colitis incidence, risk factors, and progression after kidney transplantation. All kidney transplant patients taking MPA who had colonic biopsies for persistent chronic diarrhea, between 2000 and 2012, at the Kidney Transplantation Unit of Botucatu Medical School Hospital, Brazil, were included. Cytomegalovirus (CMV) immunohistochemistry was performed in all biopsy specimens. Data on presenting symptoms, medications, immunosuppressive drugs, colonoscopic findings, and follow-up were obtained. Of 580 kidney transplant patients on MPA, 34 underwent colonoscopy. Colonoscopic findings were associated with MPA usage in 16 patients. The most frequent histologic patterns were non-specific colitis (31.3%), inflammatory bowel disease (IBD)-like colitis (25%), normal/near normal (18.8%), graft-versus-host disease-like (18.8%), and ischemia-like colitis (12.5%). All patients had persistent acute diarrhea and weight loss. Six of the 16 MPA-related diarrhea patients (37.5%) showed acute dehydration requiring hospitalization. Diarrhea resolved when MPA was switched to sirolimus (50%), discontinued (18.75%), switched to azathioprine (12.5%), or reduced by 50% (18.75%). No graft loss occurred. Four patients died during the study period. Late-onset MPA was more frequent, and no correlation with MPA dose or formulation was found.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study evaluated the influence of finishing and polishing procedures and differ-ent fluoride solutions on superficial morphology and chemistry of the nanofilled composite resinSupreme XT (3M) through the EDX analysis and SEM evaluation. Circular specimens (n 5 30) of 10mm diameter and 2 mm thickness were prepared, with half of the sample assays finished and polishedwith Super-Snap1sandpaper. The experimental groups were divided according to the presence or ab-sence of finishing and polishing and solutions (arti ficial saliva, 0.0 5% of manipulated sodium fluoridesolution, Fluordent Re ach, Oral B, Fluorgard). Specimens were immersed in each respective solutionfor 1 min per day, during 60 days and stored in artificial saliva at 37 6 18C between immersion peri-ods. Topography and chemical analysis was qualitative. It was observed that specimens submitted tofinishing and polishing procedures had lower superficial degradation. Fluoride solutio ns promoted su-perficial alterations on specimens, being the highest degradation obtained with Fluordent Reach. Itca n be concluded that finishing and polishing procedures and the immersion media influence the su-perficial morphology of composite resin tested; the Fluordent Reach was the flu oride solution thatmo st affected the material’s surface.
Resumo:
Aims: The study evaluated the influence of light curing units and immersionmedia on superficial morphology and chemistry of the nanofilled composite resin Supreme XT (3M)through the EDX analysis and SEM evaluation. Light curing units with different power densitiesand mode of application used were XL 3000 (480 mW/cm2), Jet Lite 4000 Plus (1230mW/cm2), andUltralume Led 5 (790 mW/cm2) and immersion media were artificial saliva, Coke1, tea and coffee,totaling 12 experimental groups. Specimens (10 mm 3 2 mm) were immersed in each respectivesolution for 5 min, three times a day, during 60 days and stored in artificial saliva at 378C 6 18Cbetween immersion periods. Topography and chemical analysis was qualitative. Findings: Groupsimmersed in artificial saliva, showed homogeneous degradation of matrix and deposition of calciumat the material surface. Regarding coffee, there was a reasonable chemical degradation with loss ofload particles and deposition of ions. For tea, superficial degradation occurred in specific areaswith deposition of calcium, carbon, potassium and phosphorus. For Coke1, excessive matrix degra-dation and loss of load particles with deposition of calcium, sodium, and potassium. Conclusion:Light curing units did not influence the superficial morphology of composite resin tested, but theimmersion beverages did. Coke1affected material’s surface more than did the other tested drinks.Microsc. Res. Tech. 73:176–181, 2010.
Resumo:
Angioinvasion/angiodestruction has been reported in a small subset of primary cutaneous anaplastic large-cell lymphomas (PCALCL). Recently, PCALCL with angioinvasive features and cytotoxic phenotype has been characterized as a variant associated with good clinical outcomes despite worrisome histopathologic features. We report a case of PCALCL with angioinvasive features and cytotoxic phenotype associated with reparative changes on the wall of medium-sized vessels involved by the neoplasm, including intimal fibroblastic proliferation and luminal obliteration. This vascular pattern, although previously unreported in PCALCL, is in accordance with the indolent behavior observed in this entity and provides a further link with lymphomatoid papulosis type E.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To evaluate the influence of the geometry and design of prosthetic crown preparations on stress distribution in compression tests, using finite element analysis (FEA). Materials and Methods: Six combinations of 3D drawings of all-ceramic crowns (yttria-stabilized zirconia framework and porcelain veneer) were evaluated: F, flat preparation and simplified crown; FC, flat preparation and crown with contact point; FCM, flat preparation and modified crown; A, anatomical preparation and simplified anatomical crown framework; AC, anatomical preparation and crown with contact point; and ACM, anatomical preparation and modified crown. Bonded contact types at all interfaces with the mesh were assigned, and the material properties used were according to the literature. A 200 N vertical load was applied at the center of each model. The maximum principal stresses were quantitatively and qualitatively analyzed. Results: The highest values of tensile stress were observed at the interface between the ceramics in the region under the load application for the simplified models (F and A). Reductions in stress values were observed for the model with the anatomical preparation and modified infrastructure (ACM). The stress distribution in the flat models was similar to that of their respective anatomical models. Conclusions: The modified design of the zirconia coping reduces the stress concentration at the interface with the veneer ceramic, and the simplified preparation can exert a stress distribution similar to that of the anatomical preparation at and near the load point, when load is applied to the center of the crown.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)