941 resultados para dye intercalation
Resumo:
It is suggested that previous data indicate 3 major epidemics of kala-azar in Assam between 1875 and 1950, with inter-epidemic periods of 30-45 and 20 years. This deviates from the popular view of regular cycles with a 10-20 year period. A deterministic mathematical model of kala-azar is used to find the simplest explanation for the timing of the 3 epidemics, paying particular attention to the role of extrinsic (drugs, natural disasters, other infectious diseases) versus intrinsic (host and vector dynamics, birth and death rates, immunity) processes in provoking the second. We conclude that, whilst widespread influenza in 1918-1919 may have magnified the second epidemic, intrinsic population processes provide the simplest explanation for its timing and synchrony throughout Assam. The model also shows that the second inter-epidemic period is expected to be shorter than the first, even in the absence of extrinsic agents, and highlights the importance of a small fraction of patients becoming chronically infectious (with post kala-azar dermal leishmaniasis) after treatment during an epidemic.
Resumo:
The photoisomerisation of a flexoelectric chiral nematic bimesogen system dyed with an azo dye has been investigated. The host material has a pitch and field dependent tilt angle that are temperature independent. Upon illumination by ultra violet, the azo dye molecules undergo a shape change from their trans to cis isomer. The effect of the shape change of the dye on the mixture is to decrease the I-N* transition temperatures, to increase the response times and to decrease the transmitted optical intensity. For the same reduced temperatures, the tilt angles, pitch and threshold voltages for the transition from focal conic to homeotropic textures are unchanged. The macroscopic parameters observed suggest that the orientational order parameter of the system is reduced by UV illumination. The cis isomers do not appear to separate from the host material or significantly change the flexoelectric coefficient. © 2001 OPA (Overseas Publishers Association) N.V. Published by license under the Gordon and Breach Science Publishers imprint, a member of the Taylor & Francis Group.
Resumo:
In this work, we examine the phenomenon of random lasing from the smectic A liquid crystal phase. We summarise our results to date on random lasing from the smectic A phase including the ability to control the output from the sample using applied electric fields. In addition, diffuse random lasing is demonstrated from the electrohydrodynamic instabilities of a smectic A liquid crystal phase that has been doped with a low concentration of ionic impurities. Using a siloxane-based liquid crystal doped with ionic impurities and a laser dye, nonresonant random laser emission is observed from the highly scattering texture of the smectic A phase which is stable in zero-field. With the application of a low frequency alternating current electric field, turbulence is induced due to motion of the ions. This is accompanied by a decrease in the emission linewidth and an increase in the intensity of the laser emission. The benefit in this case is that a field is not required to maintain the texture as the scattering and homeotropic states are both stable in zero field. This offers a lower power consumption alternative to the electric-field induced static scattering sample.
Resumo:
In this paper, we review our recent experimental work on coherent and blue phase liquid crystal lasers.We will present results on thin-film photonic band edge lasing devices using dye-doped low molar mass liquid crystals in self-organised chiral nematic and blue phases. We show that high Q-factor lasers can be achieved in these materials and demonstrate that a single mode output with a very narrow line width can be readily achievable in well-aligned mono-domain samples. Further, we have found that the performance of the laser, i.e. the slope efficiency and the excitation threshold, are dependent upon the physical parameters of the low molar mass chiral nematic liquid crystals. Specifically, slope efficiencies greater than 60% could be achieved depending upon the materials used and the device geometry employed. We will discuss the important parameters of the liquid crystal host/dye guest materials and device configuration that are needed to achieve such high slope efficiencies. Further we demonstrate how the wavelength of the laser can be tuned using an in-plane electric field in a direction perpendicular to the helix axis via a flexoelectric mechanism as well as thermally using thermochromic effects. We will then briefly outline data on room temperature blue phase lasers and further show how liquid crystal/lenslet arrays have been used to demonstrate 2D laser emission of any desired wavelength. Finally, we present preliminary data on LED/incoherent pumping of RG liquid crystal lasers leading to a continuous wave output. © 2009 SPIE.
Resumo:
Like large insects, micro air vehicles operate at low Reynolds numbers O(1; 000 - 10; 000) in a regime characterized by separated flow and strong vortices. The leading-edge vortex has been identified as a significant source of high lift on insect wings, but the conditions required for the formation of a stably attached leading-edge vortex are not yet known. The waving wing is designed to model the translational phase of an insect wing stroke by preserving the unsteady starting and stopping motion as well as three-dimensionality in both wing geometry (via a finite-span wing) and kinematics (via wing rotation). The current study examines the effect of the spanwise velocity gradient on the development of the leading-edge vortex along the wing as well as the effects of increasing threedimensionalityby decreasing wing aspect ratio from four to two. Dye flow visualization and particle image velocimetry reveal that the leading-edge vortices that form on a sliding or waving wing have a very high aspect ratio. The structure of the flow is largely two-dimensional on both sliding and waving wings and there is minimal interaction between the leading-edge vortices and the tip vortex. Significant spanwise flow was observed on the waving wing but not on the sliding wing. Despite the increased three-dimensionality on the aspect ratio 2 waving wing, there is no evidence of an attached leading-edge vortex and the structure of the flow is very similar to that on the higher-aspect-ratio wing and sliding wing. © Copyright 2010.
Resumo:
The study of band-edge lasing from dye-doped chiral nematic liquid crystals has thus far been largely restricted to visible wavelengths. In this paper, a wide range of commercially available laser dyes are examined for their suitability as infrared emitters within a chiral nematic host. Problems such as poor solubility and reduced quantum efficiencies are overcome, and successful band-edge lasing is demonstrated within the range of 735-850 nm, using the dyes LD800, HITC-P and DOTC-P. This paper also reports on progress towards widely tuneable liquid crystal lasers, capable of emission in the region 460- 850 nm. Key to this is the use of common pump source, capable of simultaneously exciting all of the dyes (both infrared and visible) that are present within the system. Towards this aim, we successfully demonstrate near-infrared lasing (800 nm) facilitated by Förster energy transfer between the visible dye DCM, and the infra-red dye LD800, enabling pump wavelengths anywhere between 420 and 532 nm to be used. These results demonstrate that small and low-cost tuneable visible to near-infrared laser sources are achievable, using a single common pump source. Such devices are envisaged to have wide-ranging applications including medical imaging (including optical coherence tomography), point-of-care optical medical diagnostics (such as flow cytometry), telecommunications, and optical signatures for security coatings. © 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Resumo:
A study was undertaken examining the effect of malachite green on the development and survival of the zoeae, mysis and post-larvae of Penaeus monodon. Sensitivity varied with the different larval stages; the zoeae appeared to be the least tolerant. The prophylactic potentials of malachite green in the control of Lagenidiumand Zoothamnium infesting P. monodon larvae are considered briefly. Toxicity risks may be reduced by application between ecdyses or by the removal of the dye by filtration through activated carbon.
Resumo:
AIM: To identify the anti-human immunodeficiency virus type 1 (HIV-1) activities of alpha-momorcharin ( alpha-MMC) from Momordica charantia in acutely and chronically infected lymphocytes. METHODS: The anti-HIV activities of alpha-MMC were examined by 1) the inhibition of syncytia formation induced by HIV-1 III B; 2) reduction of p24 core antigen expression level and decrease in numbers of HIV antigen positive cells in acutely and chronically infected cultures. The cytotoxic effects of alpha-MMC was tested by trypan blue dye exclusion or colorimetric MTT assay. RESULTS: alpha-MMC was found to obviously inhibit HIV-1 III B-inducing C8166 syncytia formation and markedly reduced both expression of p24 core antigen and the numbers of HIV antigen positive cells in acutely but not chronically HTV-1-infected culture. The median effective concentration (EC50) in these assays were 0.016, 0.07, and 0.32 mg.L-1, respectively. CONCLUSION: alpha-MMC is a unique component of momorcharin with anti-HIV activity, and markedly inhibited HIV-1 replication in acutely but not chronically HIV-1-infected T-lymphocytes.
Resumo:
Study on the biomarkers types to assess health status of marine ecosystems in environmental biomonitoring has an important value. Accordingly, accumulation of polycyclic aromatic hydrocarbons(PAHs) in sediment, water and tissues (liver and gill) of mudskipper(i.e. Boleophthalmus dussumieri) and some physiological responses like lysosomal membrane change performed on haemocytes, stability of red blood cell membrane and the Glutathione-S Transferase (GST) activity in the liver were measured in mudskipper. Samples were obtained from five sites along north western coast of the Persian Gulf (Khuzestan coast). Red blood cell membrane changes after different concentration of PAHs at different time was also studied to evaluate impact of PAHs compound on cell membrane. PAHs concentration was measured by HPLC method. The activity of GST enzyme was analysed by spectrophotometric method. Lysosomal membrane change was measured by NRR time method and stability of red blood cell membrane was evaluated by EOF test. Total PAH concentrations in the coastal sea water, the sediments, the liver and the gill tissues ranged between 0.80-18.34 μg/l, 113.50-3384.34 ng g-1 (dry weight), 3.99-46.64 ng g-1 dw and 3.11-17.76 ng g-1 dw, respectively. Highest PAHs pollution was found at Jafari while the lowest was detected at Bahrakan sampling sites. The lowest enzymatic activity was identified at Bahrakan (7.19 ± 1.541 nmol/mg protein/min), while the highest was recorded at Jafari (46.96 ± 7.877 nmol/mg protein/min). Comparative analysis of GST activity in the liver of mudskippers showed significant difference (p < 0.05) between the locations of Jafari and Bahrakan, and with other sites. Moreover, no significant difference was detected between the locations of Arvand, Zangi and Samayeli (p < 0.05). The mean RT was below 90 minutes in all sampling sites. Values of mean RT of the dye ranged from 34 (for the blood samples of mudskipper collected from Jafari site) to 78 minutes (for the blood samples of mudskipper collected from Bahrakan site). Spatial evaluation revealed the longest RT in fish from Bahrakan as compared with those from other sites. Preliminary results showed a significant difference (p < 0.05) among sampling sites except between Arvand and Zangi (p > 0.05). Osmotic fragility curves indicated that erythrocytes collected from mudskippers at Jafari were the most 009 fragile followed by Zangi> Arvand> Samayeli> and Bahrakan. The mean erythrocyte fragility was significantly higher at Jafari site (p < 0.05) when compared to other sites. Significant differences were found between the various sites (p < 0.05).The result indicated no significant differences between the control and treatments of mudskipper RBC exposed to field concentrations of PAHs (P>0.05). The results further indicated significant differences (P<0.05) between the control and treatments of mudskipper RBC exposed to acute. Potency Divisor concentrations. It is clear from the present result that chronic. Potency Divisor concentrations protect red cells against osmotic hemolysis. This study, however, showed that PAH concentrations in this region are not higher than the available standards. The findings showed that Lysosomal membrane destabilization, liver GST activities and fragility of red cell membrane are highly sensitive in the mudskipper, B. dussumieri. Thus, mudskipper perceived to be good sentinel organisms for PAH pollution monitoring. Sediment PAH concentrations were strongly correlated with biomarkers, indicating that PAH type pollutants were biologically available to fish. One of the possible risk assessment implications of this study is that biomarkers can be applied not only to characterize biological effects of pollution exposures, but also to determine the bioavailability of pollution in aquatic systems. The results also indicated that PAHs compound possess anti haemolytic property.
Resumo:
Biochemical ecotoxicology and biomarkers using are a new sciences that are used for biomonitoring in aquatic environment. Biomonitoring plays a vital role in strategies to identify, assess, and control contaminants. On the other hands in recent year's attention to polycyclic Aromatic Hydrocarbons (PAHs) and heavy metals increased in aquatic environments because of their carcinogenic and mutagenic properties combined with their nearly ubiquitous distribution in depositional environments by oil pollution or industrial waste waters. The present research aimed to assess PAHs and Ni, V levels in surface sediments and bivalves (Anodonta cygnea)and the effects of PAHs and heavy metals (Ni,V) on the hemocyte of the Anodonta cygnea were investigated in 2 stations (Mahrozeh, Selke in Anzali Lagoon, North of Iran). Samples were collected during at 2 different periods of the year, Dry and rain seasons, (June & September) and to confirm our first observations, Cage station is added. The bivalves hemocytes were monitored for membrane injury by NRR methods (neutral red retention assay). Heavy metal (Ni, V) concentrations were determined by Atomic Absorption in Anodonta cygnea and the sediments in Anzali Lagoon. The vanadium concentration in bivalves and sediments was ND(not detect )-0.4231 μg/g and 1.4381-306.9603 μg/g dry weight respectively. Nickel concentration in bivalves and sediments was 0.0231-1.3351, 0.4024-19.3561 μg/g dry weight respectively. PAHs concentrations were determined by GC-Mass in Anodonta cygnea and the sediments. Average concentration of PAHs is 115-373.788 ng/g dry weight in bivalves and average concentration of PAHs is 34.85-1339.839 ng/g dry weight in sediments. Bioaccumulation sediments factor(BASF) is high about PAHs (>1) and BASF is low for Ni, V (<1) . Internal Damage mechanisms of bivalves hemocytes (cell mortality, dye leakage, decreased membrane stability, are observed (Lowe Methods). Statistical analysis was used to explore the relationship between altered cellular and above contaminants. There are power and negative correlations between PAHs and NRR method for hemocytes in Anodonta cygnea (P<0.0005), but good correlation is not observed between Ni, V and NRR method for hemocytes in every time. This research indicates that the NRR assay is a useful screening technique able to discriminate polluted sites and at first we announce that Anodonta cygnea hemocytes are efficient biomarker for PAHs pollutants in fresh water.
Resumo:
The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 νm. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required. © 2011 IOP Publishing Ltd.
Resumo:
The study of band-edge lasing from dye-doped chiral nematic liquid crystals has thus far been largely restricted to visible wavelengths. In this paper, a wide range of commercially available laser dyes are examined for their suitability as infrared emitters within a chiral nematic host. Problems such as poor solubility and reduced quantum efficiencies are overcome, and successful band-edge lasing is demonstrated within the range of 735-850 nm, using the dyes LD800, HITC-P and DOTC-P. This paper also reports on progress towards widely tuneable liquid crystal lasers, capable of emission in the region 460- 850 nm. Key to this is the use of common pump source, capable of simultaneously exciting all of the dyes (both infrared and visible) that are present within the system. Towards this aim, we successfully demonstrate near-infrared lasing (800 nm) facilitated by Förster energy transfer between the visible dye DCM, and the infra-red dye LD800, enabling pump wavelengths anywhere between 420 and 532 nm to be used. These results demonstrate that small and low-cost tuneable visible to near-infrared laser sources are achievable, using a single common pump source. Such devices are envisaged to have wide-ranging applications including medical imaging (including optical coherence tomography), point-of-care optical medical diagnostics (such as flow cytometry), telecommunications, and optical signatures for security coatings. © 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Resumo:
In this paper, we review our recent experimental work on coherent and blue phase liquid crystal lasers.We will present results on thin-film photonic band edge lasing devices using dye-doped low molar mass liquid crystals in self-organised chiral nematic and blue phases. We show that high Q-factor lasers can be achieved in these materials and demonstrate that a single mode output with a very narrow line width can be readily achievable in well-aligned mono-domain samples. Further, we have found that the performance of the laser, i.e. the slope efficiency and the excitation threshold, are dependent upon the physical parameters of the low molar mass chiral nematic liquid crystals. Specifically, slope efficiencies greater than 60% could be achieved depending upon the materials used and the device geometry employed. We will discuss the important parameters of the liquid crystal host/dye guest materials and device configuration that are needed to achieve such high slope efficiencies. Further we demonstrate how the wavelength of the laser can be tuned using an in-plane electric field in a direction perpendicular to the helix axis via a flexoelectric mechanism as well as thermally using thermochromic effects. We will then briefly outline data on room temperature blue phase lasers and further show how liquid crystal/lenslet arrays have been used to demonstrate 2D laser emission of any desired wavelength. Finally, we present preliminary data on LED/incoherent pumping of RG liquid crystal lasers leading to a continuous wave output. © 2009 SPIE.
Resumo:
Smectic A liquid crystals, based upon molecular structures that consist of combined siloxane and mesogenic moieties, exhibit strong multiple scattering of light with and without the presence of an electric field. This paper demonstrates that when one adds a laser dye to these compounds it is possible to observe random laser emission under optical excitation, and that the output can be varied depending upon the scattering state that is induced by the electric field. Results are presented to show that the excitation threshold of a dynamic scattering state, consisting of chaotic motion due to electro-hydrodynamic instabilities, exhibits lower lasing excitation thresholds than the scattering states that exist in the absence of an applied electric field. However, the lowest threshold is observed for a dynamic scattering state that does not have the largest scattering strength but which occurs when there is optimization of the combined light absorption and scattering properties. © 2012 American Institute of Physics.
Resumo:
Background: The anti-HIV-1 neutralizing antibody assay is widely used in AIDS vaccine research and other experimental and clinical studies. The vital dye staining method applied in the detection of anti-HIV-1 neutralizing antibody has been used in many laboratories. However, the unknown factor(s) in sera or plasma affected cell growth and caused protection when the tested sera or plasma was continuously maintained in cell culture. In addition, the poor solubility of neutral red in medium (such as RPMI-1640) also limited the use of this assay. Methods: In this study, human T cell line C8166 was used as host cells, and 3-(4,5-Dimethyl-2-thiazolyl)- 2,5-diphenyl-2H-tetrazolium bromide (MTT) instead of neutral red was used as vital dye. In order to avoid the effect of the unknown factor( s), the tested sera or plasma was removed by a washout procedure after initial 3 - 6 h culture in the assay. Result: This new assay eliminated the effect of the tested sera or plasma on cell growth, improved the reliability of detection of anti-HIV-1 neutralizing antibody, and showed excellent agreement with the p24 antigen method. Conclusion: The results suggest that the improved assay is relatively simple, highly duplicable, cost-effective, and well reliable for evaluating anti-HIV-1 neutralizing antibodies from sera or plasma.