953 resultados para camera calibration
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Prostaglandins control osteoblastic and osteoclastic function under physiological or pathological conditions and are important modulators of the bone healing process. The non-steroidal anti-inflammatory drugs (NSAIDs) inhibit cyclooxygenase (COX) activity and consequently prostaglandins synthesis. Experimental and clinical evidence has indicated a risk for reparative bone formation related to the use of non-selective (COX-1 and COX-2) and COX-2 selective NSAIDs. Ketorolac is a non-selective NSAID which, at low doses, has a preferential COX-1 inhibitory effect and etoricoxib is a new selective COX-2 inhibitor. Although literature data have suggested that ketorolac can interfere negatively with long bone fracture healing, there seems to be no study associating etoricoxib with reparative bone formation. Paracetamol/acetaminophen, one of the first choices for pain control in clinical dentistry, has been considered a weak anti-inflammatory drug, although supposedly capable of inhibiting COX-2 activity in inflammatory sites. OBJECTIVE: The purpose of the present study was to investigate whether paracetamol, ketorolac and etoricoxib can hinder alveolar bone formation, taking the filling of rat extraction socket with newly formed bone as experimental model. MATERIAL AND METHODS: The degree of new bone formation inside the alveolar socket was estimated two weeks after tooth extraction by a differential point-counting method, using an optical microscopy with a digital camera for image capture and histometry software. Differences between groups were analyzed by ANOVA after confirming a normal distribution of sample data. RESULTS AND CONCLUSIONS: Histometric results confirmed that none of the tested drugs had a detrimental effect in the volume fraction of bone trabeculae formed inside the alveolar socket.
Resumo:
OBJECTIVE: This in situ study evaluated the discriminatory power and reliability of methods of dental plaque quantification and the relationship between visual indices (VI) and fluorescence camera (FC) to detect plaque. MATERIAL AND METHODS: Six volunteers used palatal appliances with six bovine enamel blocks presenting different stages of plaque accumulation. The presence of plaque with and without disclosing was assessed using VI. Images were obtained with FC and digital camera in both conditions. The area covered by plaque was assessed. Examinations were done by two independent examiners. Data were analyzed by Kruskal-Wallis and Kappa tests to compare different conditions of samples and to assess the inter-examiner reproducibility. RESULTS: Some methods presented adequate reproducibility. The Turesky index and the assessment of area covered by disclosed plaque in the FC images presented the highest discriminatory powers. CONCLUSION: The Turesky index and images with FC with disclosing present good reliability and discriminatory power in quantifying dental plaque.
Resumo:
Gaseous N losses from soil are considerable, resulting mostly from ammonia volatilization linked to agricultural activities such as pasture fertilization. The use of simple and accessible measurement methods of such losses is fundamental in the evaluation of the N cycle in agricultural systems. The purpose of this study was to evaluate quantification methods of NH3 volatilization from fertilized surface soil with urea, with minimal influence on the volatilization processes. The greenhouse experiment was arranged in a completely randomized design with 13 treatments and five replications, with the following treatments: (1) Polyurethane foam (density 20 kg m-3) with phosphoric acid solution absorber (foam absorber), installed 1, 5, 10 and 20 cm above the soil surface; (2) Paper filter with sulfuric acid solution absorber (paper absorber, 1, 5, 10 and 20 cm above the soil surface); (3) Sulfuric acid solution absorber (1, 5 and 10 cm above the soil surface); (4) Semi-open static collector; (5) 15N balance (control). The foam absorber placed 1 cm above the soil surface estimated the real daily rate of loss and accumulated loss of NH3N and proved efficient in capturing NH3 volatized from urea-treated soil. The estimates based on acid absorbers 1, 5 and 10 cm above the soil surface and paper absorbers 1 and 5 cm above the soil surface were only realistic for accumulated N-NH3 losses. Foam absorbers can be indicated to quantify accumulated and daily rates of NH3 volatilization losses similarly to an open static chamber, making calibration equations or correction factors unnecessary.
Resumo:
OBJETIVOS: o presente estudo radiográfico, retrospectivo e longitudinal objetivou determinar se a ancoragem do aparelho expansor fixo tipo Haas, modificado para as dentaduras decídua e mista, interfere na velocidade de rizólise e esfoliação dos caninos decíduos. MÉTODOS: foi feita uma avaliação quantitativa da rizólise do canino decíduo mediante a medição do comprimento coroa-ápice dos caninos decíduos superiores, dos lados direito e esquerdo. Para essa avaliação, 24 crianças submetidas à expansão rápida da maxila (ERM) na dentadura decídua ou no início da dentadura mista foram comparadas com 15 crianças que não passaram por esse procedimento. A medição do comprimento coroa-ápice dos caninos decíduos foi realizada com o programa computadorizado CEF-X Cefalometria Digital, produzido pela CDT Informática, que permitiu calibrar o tamanho dos dentes pela uniformização das imagens radiográficas digitalizadas. RESULTADOS: os dados estatísticos revelaram que não houve diferença na velocidade de rizólise dos caninos decíduos entre as crianças do grupo controle e as do grupo submetido à ERM. CONCLUSÕES: é possível inferir que o aparelho expansor fixo tipo Haas ancorado em dentes decíduos não influencia a rizólise dos caninos decíduos usados como ancoragem.
Resumo:
OBJETIVO: Desenvolver um método e um dispositivo para quantificar a visão em candela (cd). Os estudos de medida da visão são importantes para todas as ciências visuais. MÉTODOS: É um estudo teórico e experimental. Foram descritos os detalhes do método psicofísico e da calibração do dispositivo. Foram realizados testes preliminares em voluntários. RESULTADOS: É um teste psicofísico simples e com resultado expresso em unidades do sistema internacional de medidas. Com a descrição técnica será possível reproduzir o experimento em outros centros de pesquisa. CONCLUSÃO: Os resultados aferidos em intensidade luminosa (cd) são uma opção para estudo visual. Esses resultados possibilitarão extrapolar medidas para modelos matemáticos e para simular efeitos individuais com dados aberrométricos.
Resumo:
OBJETIVO: Desenvolver a instrumentação e o "software" para topografia de córnea de grande-ângulo usando o tradicional disco de Plácido. O objetivo é permitir o mapeamento de uma região maior da córnea para topógrafos de córnea que usem a técnica de Plácido, fazendo-se uma adaptação simples na mira. MÉTODOS: Utilizando o tradicional disco de Plácido de um topógrafo de córnea tradicional, 9 LEDs (Light Emitting Diodes) foram adaptados no anteparo cônico para que o paciente voluntário pudesse fixar o olhar em diferentes direções. Para cada direção imagens de Plácido foram digitalizadas e processadas para formar, por meio de algoritmo envolvendo elementos sofisticados de computação gráfica, um mapa tridimensional completo da córnea toda. RESULTADOS: Resultados apresentados neste trabalho mostram que uma região de até 100% maior pode ser mapeada usando esta técnica, permitindo que o clínico mapeie até próximo ao limbo da córnea. São apresentados aqui os resultados para uma superfície esférica de calibração e também para uma córnea in vivo com alto grau de astigmatismo, mostrando a curvatura e elevação. CONCLUSÃO: Acredita-se que esta nova técnica pode propiciar a melhoria de alguns processos, como por exemplo: adaptação de lentes de contato, algoritmos para ablações costumizadas para hipermetropia, entre outros.
Resumo:
An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.
Resumo:
This is a review of direct analysis using solid sampling graphite furnace atomic absorption spectrometry. Greater emphasis is dedicated to sample preparation, sample homogeneity, calibration and its application to microanalysis and micro-homogeneity studies. The main advantages and some difficulties related to the applicability of this technique are discussed. A literature search on the application of solid sampling graphite furnace atomic absorption spectrometry in trace element determination in many kinds of samples, including biological, clinical, technological and environmental ones, is also presented.
Resumo:
Solid-phase microextraction, using on-line bis(trimethylsilyl)trifluoroacetamide derivatisation, gas chromatography, and mass spectrometry, was evaluated in the quantification of 3-chloro-4-(dichloromethyl)-5-hydroxy-2(5H)-furanone (MX) in water samples. Fibres encompassing a wide range of polarities were used with headspace and direct immersion sampling. For the immersion procedure, various parameters affecting MX extraction, including pH, salinity, temperature, and extraction time were evaluated. The optimised method (polyacrylate fibre; 20% Na2SO4; pH 2.0; 60 min; 20 °C) was applied for reservoir chlorinated water samples-either natural or spiked with MX (50 ng L-1 and 100 ng L-1). The recovery of MX ranged from 44 to 72%. Quantification of MX in water samples was done using external standard and the selected ion monitoring mode. Correlation coefficient (0.98%), relative standard deviation (5%), limit of detection (30 ng L-1) and limit of quantification (50 ng L-1) were obtained from calibration curve.
Resumo:
Um método espectrofotométrico simples foi desenvolvido para a determinação do bromidrato de fenoterol (BF) em comprimidos, gotas e xarope, como princípio ativo único e associado ao ibuprofeno. O método se baseia na reação de acoplamento oxidativo do BF com o 3-metil-2-benzotiazolinona hidrazona (MBTH), na presença de sulfato cérico, como agente oxidante. A mistura de BF, MBTH e sulfato cérico, em meio ácido, produz um composto colorido (vermelho castanho) com máximo de absorção a 475 nm. A curva de calibração foi linear num intervalo de concentração de 3,0 a 12,0 µg/mL, com coeficiente de correlação linear de 0,9998. Os parâmetros experimentais que afetam o desenvolvimento e a estabilidade do produto colorido foram cuidadosamente estudados e otimizados. O método foi aplicado em amostras comerciais e simuladas, obtendo-se coeficientes de variação entre 0,25 % a 0,82 % e médias de recuperação do padrão que variaram de 98 % a 102 %. O método proposto mostrou-se exato, preciso, linear e não é passível de interferência de excipientes, para as formas farmacêuticas comprimidos e gotas. Não houve interferência do ibuprofeno que consta de uma das formulações analisadas, associado ao BF. Quanto ao xarope, houve interferência do veículo sugerindo reações de seus componentes com o MBTH.
Resumo:
O maior entrave para o estudo da síndrome metabólica na adolescência consiste na carência de pontos de corte consolidados para tal grupo etário. O presente estudo se propôs a caracterizar os marcadores de risco para a síndrome metabólica em adolescentes do sexo feminino e verificar as possíveis correlações existentes entre variáveis analisadas. Tal estudo foi realizado com 60 adolescentes, do sexo feminino, entre 14 e 18 anos de idade. Foram analisados o índice de massa corporal e seus derivados, as circunferências da cintura (C) e quadril (Q), o percentual de gordura corporal (%G) e as dosagens plasmáticas de colesterol total (CT), frações (LDL e HDL) e glicemia de jejum. Apesar da predominância da eutrofi a (90%), encontraram-se alterações importantes: elevado percentual de gordura corporal (78,3%), níveis alterados de lipídios sangüíneos, 23,3% (CT), 15% (LDL) e 5% (HDL), glicemia de jejum alterada em 6,7%, sendo que em uma das adolescentes foi diagnosticado o diabetes Mellitus. Observaram-se correlações signifi cantes entre HDL e relação C/Q (r = -0,276; p=0,032) e LDL e %G (r = 0,296; p=0,021) e entre o número de alterações apresentadas pelas adolescentes e os valores %G (r=0,300, p=0,020); CT (r=0,536, p<0,001) e LDL (r=0,506, p<0,001). A importância de tais alterações neste grupo etário se justifi ca em função do seu signifi cado clínico, uma vez que irão predispor ao aumento das taxas de morbi-mortalidade por doenças crônicas não transmissíveis na vida adulta
Resumo:
O objetivo foi estimar as regressões de calibração dos dados dietéticos mensurados pelo questionário quantitativo de freqüência alimentar (QQFA) utilizado no Natural History of HPV Infection in Men: o Estudo HIM. Uma amostra de 98 indivíduos do estudo HIM respondeu, por meio de entrevista, a um QQFA e três recordatórios de 24 horas (R24h). A calibração foi feita por meio de análise de regressão linear, tendo os R24h como variável dependente e o QQFA como variável independente. Idade, índice de massa corporal, atividade física, renda e escolaridade foram utilizadas como variáveis de ajuste nos modelos. As médias geométricas dos R24h e do QQFA corrigido pela calibração são estatisticamente iguais. Os gráficos de dispersão entre os instrumentos demonstraram aumento da correlação após a correção dos dados, porém observa-se maior dispersão dos pontos de acordo com a piora do poder explicativo dos modelos. A identificação das regressões de calibração dos dados dietéticos do estudo HIM permitirá a estimativa do efeito da dieta sobre a infecção por HPV, corrigida pelo erro de medida do QQFA
Resumo:
Background and Purpose: Several different methods of teaching laparoscopic skills have been advocated, with virtual reality surgical simulation (VRSS) being the most popular. Its effectiveness in improving surgical performance is not a consensus yet, however. The purpose of this study was to determine whether practicing surgical skills in a virtual reality simulator results in improved surgical performance. Materials and Methods: Fifteen medical students recruited for the study were divided into three groups. Group I (control) did not receive any VRSS training. For 10 weeks, group II trained basic laparoscopic skills (camera handling, cutting skill, peg transfer skill, and clipping skill) in a VRSS laparoscopic skills simulator. Group III practiced the same skills and, in addition, performed a simulated cholecystectomy. All students then performed a cholecystectomy in a swine model. Their performance was reviewed by two experienced surgeons. The following parameters were evaluated: Gallbladder pedicle dissection time, clipping time, time for cutting the pedicle, gallbladder removal time, total procedure time, and blood loss. Results: With practice, there was improvement in most of the evaluated parameters by each of the individuals. There were no statistical differences in any of evaluated parameters between those who did and did not undergo VRSS training, however. Conclusion: VRSS training is assumed to be an effective tool for learning and practicing laparoscopic skills. In this study, we could not demonstrate that VRSS training resulted in improved surgical performance. It may be useful, however, in familiarizing surgeons with laparoscopic surgery. More effective methods of teaching laparoscopic skills should be evaluated to help in improving surgical performance.
Three-dimensional finite element thermal analysis of dental tissues irradiated with Er,Cr:YSGG laser
Resumo:
In the present study, a finite element model of a half-sectioned molar tooth was developed in order to understand the thermal behavior of dental hard tissues (both enamel and dentin) under laser irradiation. The model was validated by comparing it with an in vitro experiment where a sound molar tooth was irradiated by an Er,Cr:YSGG pulsed laser. The numerical tooth model was conceived to simulate the in vitro experiment, reproducing the dimensions and physical conditions of the typical molar sound tooth, considering laser energy absorption and calculating the heat transfer through the dental tissues in three dimensions. The numerical assay considered the same three laser energy densities at the same wavelength (2.79 mu m) used in the experiment. A thermographic camera was used to perform the in vitro experiment, in which an Er, Cr: YSGG laser (2.79 mu m) was used to irradiate tooth samples and the infrared images obtained were stored and analyzed. The temperature increments in both the finite element model and the in vitro experiment were compared. The distribution of temperature inside the tooth versus time plotted for two critical points showed a relatively good agreement between the results of the experiment and model. The three dimensional model allows one to understand how the heat propagates through the dentin and enamel and to relate the amount of energy applied, width of the laser pulses, and temperature inside the tooth. (C) 2008 American Institute of Physics. [DOI: 10.1063/1.2953526]