969 resultados para Validation Measures
Resumo:
Climate innovations, that cover both technological applications and process and service innovations, play a key role in climate change mitigation. The purpose of this study was to examine how the Finnish innovation system could be enhanced with governmental measures so that the diffusion of climate innovations could be speeded up. During the study, it became evident that the governmental measures need to support the whole innovation chain, which comprises of research, development, demonstration and deployment. Only this can lead to the successful birth and diffusion of low carbon innovations. The study found that the strengths of the Finnish innovation system are research and development, and the current national innovation policies strongly support these activities. However, these have been emphasised at the expense of the demonstration and deployment. Consequently, the biggest bottlenecks in the Finnish innovation landscape are the lack of pilot and demonstration projects and slow commercialisation, thus the high price of the innovation. To meet with the challenge, the government should firstly promote strict greenhouse gas emission reduction targets. This would boost up the innovation activities, which would also lower the prices of the innovations. To speed up the commercialisation process, measures that stimulate the domestic market, such as feed-in-tariffs and public procurements, are needed. Special attention should also be paid to the measures that could shift the traditional closed innovation chain towards open innovation. This means that the product development should involve experts from several fields such as the user and marketing experts to speed up the commercialisation. In addition, efficient innovation co-operation between both private and public sector is essential. Finally, as the domestic resources are not adequate for producing all the innovations needed, the domestic innovation activities should be focused on a few sectors, and at the same time promote efficient import policies.
Resumo:
Aim: To investigate and understand patient's satisfaction with nursing care in the intensive care unit to identify the dimensions of the concept of"satisfaction" from the patient's point of view. To design and validate a questionnaire that measures satisfaction levels in critical patients. Background: There are many instruments capable of measuring satisfaction with nursing care; however, they do not address the reality for critical patients nor are they applicable in our context. Design: A dual approach study comprising: a qualitative phase employing Grounded Theory and a quantitative and descriptive phase to prepare and validate the questionnaire. Methods: Data collection in the qualitative phase will consist of: in-depth interview after theoretical sampling, on-site diary and expert discussion group. The sample size will depend on the expected theoretical saturation n = 27-36. Analysis will be based on Grounded Theory. For the quantitative phase, the sampling will be based on convenience (n = 200). A questionnaire will be designed on the basis of qualitative data. Descriptive and inferential statistics will be used. The validation will be developed on the basis of the validity of the content, the criteria of the construct and reliability of the instrument by the Cronbach's alpha and test-retest approach. Approval date for this protocol was November 2010. Discussion: Self-perceptions, beliefs, experiences, demographic, socio-cultural epistemological and political factors are determinants for satisfaction, and these should be taken into account when compiling a questionnaire on satisfaction with nursing care among critical patients.
Resumo:
This work describes a validation of an analytical procedure for the analysis of petroleum hydrocarbons in marine sediment samples. The proposed protocol is able to measure n-alkanes and polycyclic aromatic hydrocarbons (PAH) in samples at concentrations as low as 30 ng/g, with a precision better than 15% for most of analytes. The extraction efficiency of fortified sediments varied from 65.1 to 105.6% and 59.7 to 97.8%, for n-alkanes and PAH in the ranges: C16 - C32 and fluoranthene - benzo(a)pyrene, respectively. The analytical protocol was applied to determine petroleum hydrocarbons in sediments collected from a marine coastal zone.
Resumo:
This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.
Resumo:
A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.
Resumo:
A new method is described for the determination of the herbicide bispyribac-sodium in surface water, especially from river and irrigated rice water samples. The method involves extraction in solid phase and quantification by high performance liquid chromatography with diode array detection (HPLC-DAD). After optimization of the extraction and separation parameters, the method was validated. The method presented average recoveries of 101.3 and 97.7%, under repeatability and intermediate precision conditions, respectively, with adequate precision (RSD from 0.9 to 7.5%). The method was applied for the determination of bispyribac-sodium in surface water samples with a limit of detection of 0.1 μg L-1.
Resumo:
This study validated a high performance liquid chromatography (HPLC) method for the quantitative evaluation of quercetin in topical emulsions. The method was linear within 0.05 - 200 μg/mL range with a correlation coefficient of 0.9997, and without interference in the quercetin peak. The detection and quantitation limits were 18 and 29 ng/mL, respectively. The intra- and inter-assay precisions presented R.S.D. values lower than 2%. An average of 93% and 94% of quercetin was recovered for non-ionic and anionic emulsions, respectively. The raw material and anionic emulsion, but not non-ionic emulsion, were stable in all storage conditions for one year. The method reported is a fast and reliable HPLC technique useful for quercetin determination in topical emulsions.
Resumo:
A gas chromatographic method has been developed for the assay of fluvastatin sodium (FLU). FLU was silylated with N,O-bis(trimethylsilyl)trifluoroacetamide-1% trimethylchlorosilane at 90 ºC for 30 min and analysed in a DB-1 column by capillary gas chromatograph with a flame ionization detector. The method was validated. The assay was linear over the concentration range at 10.0 to 50.0 µg mL-1. The limit of detection and the limit of quantitation were 1.0 and 3.0 µg mL-1, respectively. The recoveries of FLU derivatives were in the range of 99.25-99.80%. In inter-day and intra-day analysis, the values of relative standard deviation (%) and the relative mean error (%) were found between 0.20-0.80% and -0.20-0.75%, respectively. The developed method was succesfully applied to analyze the FLU content in tablet formulation. The results were statistically compared with those obtained by the official method, and no significant difference was found between the two methods. Therefore, it can be recommended for the quality control assay of FLU in pharmaceutical industry.
Resumo:
A reversed-phase liquid chromatographic (LC) and ultraviolet (UV) spectrophotometric methods were developed and validated for the assay of bromopride in oral and injectable solutions. The methods were validated according to ICH guideline. Both methods were linear in the range between 5-25 μg mL-1 (y = 41837x - 5103.4, r = 0.9996 and y = 0.0284x - 0.0351, r = 1, respectively). The statistical analysis showed no significant difference between the results obtained by the two methods. The proposed methods were found to be simple, rapid, precise, accurate, and sensitive. The LC and UV methods can be used in the routine quantitative analysis of bromopride in oral and injectable solutions.
Resumo:
The objective of this research was to develop and validate an alternative analytical method for quantitative determination of levofloxacin in tablets and injection preparations. The calibration curves were linear over a concentration range from 3.0 to 8.0 μg mL-1. The relative standard deviation was below 1.0% for both formulations and average recovery was 101.42 ± 0.45% and 100.34 ± 0.85% for tablets and injection formulations, respectively. The limit of detection and limit of quantitation were 0.08 and 0.25 μg mL-1, respectively. It was concluded that the developed method is suitable for the quality control of levofloxacin in pharmaceuticals formulations.
Resumo:
A sensitive RP-HPLC method with UV detection successfully measured phenol(s) in an ointment containing 3% Stryphnodendron adstringens extract. Chromatography used acetonitrile (0.05% trifluoroacetic acid):water (0.05% trifluoroacetic acid) (v/v), flow rate 0.8 mL min-1. Quantitation was accomplished by the external-standard method. Linearity for 2.00 to 16.00 μg mL-1 (gallic acid) and 1.14 to 18.24 μg mL-1 (gallocatechin) was established. Intra- and inter-day precision levels were under 5%. LOD and LOQ were 0.231 and 0.770 μg mL-1 (gallic acid) and 0.151 and 0.504 μg mL-1 (gallocatechin), respectively. Determination of phenols was unaffected by product excipients.
Resumo:
A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.
Resumo:
For determination of aliskiren in commercial samples, an analytical UV spectrophotometric method was developed and validate according to ICH guideline. The method was linear in the range between 40 and 100 μg mL-1 (r² = 0.9997, n = 7) and exhibited suitable specificity, accuracy, precision, and robustness. It is simple, it has low cost, and it has low use polluting reagents. Therefore, the proposed method was successfully applied for the assay and dissolution studies of aliskiren in tablet dosage forms, and the results were compared to a validated RP-LC method, showing non-significant difference (P > 0.05).
Resumo:
A LC-ESI-MS/MS method was developed and validated according to the European Union decision 2002/657/EC, for the determination of tetracyclines (TCs) in chicken-muscle since Europe is one of the main markets for Brazilian products. Linearity of r > 0.9979, limits of quantification in the range of 7.0-35.0 ng/g, average recoveries of 89.38 - 106.27%, within-day and between-day precision were adequate for all TCs. The decision limit and the detection capability were 93.00-106.46 ng/g and 95.84-114.38 ng/g, respectively. This method is suitable for application in surveillance programmes of residues of TCs in chicken-muscle samples.
Resumo:
An HPLC method was developed and validated aiming to quantify the cyclosporine-A incorporated into intraocular implants, released from them; and in direct contact with the degradation products of PLGA. The separation was carried out in isocratic mode using acetonitrile/water (70:30) as mobile phase, a C18 column at 80 ºC and UV detection at 210 nm. The method provided selectivity based on resolution among peaks. It was linear over the range of 2.5-40.0 µg/mL. The quantitation and detection limits were 0.8 and 1.2 µg/mL, respectively. The recovery was 101.8% and intra-day and inter-day precision was close to 2%.