921 resultados para Sensorineural hearing loss


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The vertical radiation loss of three-dimensional (3-D) microresonators is investigated by 3-D finite-difference time-domain (FDTD) simulation. The simulation shows that the vertical radiation causes an important loss in the microresonators with weak waveguiding, and result in decrease of the quality factors (Q-factors) of whispering-gallery (WG) modes. Through the simulation, we find that TM-like modes have much weaker vertical radiation loss than TE-like modes. High Q-factor TM-like modes are observed in the 3-D microresonators with weak vertical waveguiding, but the Q-factors of TE-like modes decrease greatly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optoelectronic packaging has become a most important factor that influences the final performance and cost of the module. In this paper, low microwave loss coplanar waveguide(CPW) on high resistivity silicon(HRS) and precise V groove in silicon substrate were successfully fabricated. The microwave attenuation of the CPW made on HRS with the simple process is lower than 2 dB/cm in the frequency range of 0 similar to 26GHz, and V groove has the accuracy in micro level and smooth surface. These two techniques built a good foundation for high frequency packaging and passive coupling of the optoelectronic devices. Based on these two techniques, a simple high resistivity silicon substrate that integrated V groove and CPW for flip-chip packaging of lasers was completed. It set a good example for more complicate optoelectronic packaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

低损耗高强度碲酸盐玻璃光纤用光学材料的优化方案

Relevância:

20.00% 20.00%

Publicador:

Resumo:

低损耗实芯碲酸盐光纤的非线性研究

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diamond (100) facets deposited at initial 1.0% CH4 have been investigated using high resolution electron energy loss spectroscopy (HREELS). The diamond (100) facets grown at 800-degrees-C are terminated by CH2 radicals, and there is no detectable frequency shift compared with the characteristic frequencies of molecular subgroup CH2. Beside the CH2 vibration loss, CH bend loss (at 140 meV) of locally monohydrogenated dimer is detected for the diamond (100) facets grown at 1000-degrees-C. Dosing the (100) facets grown at 800-degrees-C with atomic hydrogen at 1*10(-6) mbar, the loss peak at 140 meV appears. It is suggested that there are enough separately vacant sites and uniformly dispersed monohydrogenated dimers on (100) facets. This structure relaxes the steric repulsion between the adjacent hydrogen atoms during the diamond (100) surface growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By means of two dimension beam propagation method (2D-BPM) with high order Pade approximation, behaviors of SOI waveguide based bend intersections with variant bending radius are simulated and analized. The result shows that crosstalk of intersections decreases with the increase of bending radius and intersecting angle. Furthermore, loss and crosstalk characteristics of bend intersections formed by sine bend, cosine bend and arc bend are compared. Sine bend based structures are proved that it can present lowest loss and smallest crosstalk properties among the three and may find their wide application in the design of bend intersections and other more complicated photonic devices and circuits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three kinds of coplanar waveguides (CPWs) are designed and fabricated on different silicon substrates---common low-resistivity silicon substrate (LRS), LRS with a 3μm-thick silicon oxide interlayer, and high-resistivity silicon (HRS) substrate. The results show that the microwave loss of a CPW on LRS is too high to be used, but it can be greatly reduced by adding a thick interlayer of silicon oxide between the CPW transmission lines and the LRS.A CPW directly on HRS shows a loss lower than 2dB/cm in the range of 0-26GHz and the process is simple,so HRS is a more suitable CPW substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fitting process is used to measure the cavity loss and the quasi-Fermi-level separation for Fabry- Perot semiconductor lasers. From the amplified spontaneous emission (ASE) spectrum, the gain spectrum and single-pass ASE obtained by the Cassidy method are applied in the fitting process. For a 1550nm quantum well InGaAsP ridge waveguide laser, the cavity loss of about ~24cm~(-1) is obtained.