986 resultados para Scanner intraoral


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A salt weathering simulation using a mix of sodium chloride (5%) and magnesium sulphate (5%) in a salt corrosion cabinet and five granular limestones is described. Progressive surface loss from vertical exposed faces was mapped using a high resolution (sub-millimetre) object scanner (Konica Minolta Vi9i). Patterns of loss are related to surface porosity/permeability measurements obtained using a hand-held gas permeameter. Introduction of this spatial dimension into damage assessment is seen as essential for understanding the initial conditions that allow surface loss to be triggered, and changes in surface characteristics as weathering proceeds which dictate subsequent decay in space and time. Preliminary observations suggest that scanning at this high resolution is particularly valuable in quantifying very subtle trends and distortions that are pre-cursors to material loss, including surface swelling and pore filling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudar os mecanismos subjacentes à produção de fala é uma tarefa complexa e exigente, requerendo a obtenção de dados mediante a utilização de variadas técnicas, onde se incluem algumas modalidades imagiológicas. De entre estas, a Ressonância Magnética (RM) tem ganho algum destaque, nos últimos anos, posicionando-se como uma das mais promissoras no domínio da produção de fala. Um importante contributo deste trabalho prende-se com a otimização e implementação de protocolos (RM) e proposta de estratégias de processamento de imagem ajustados aos requisitos da produção de fala, em geral, e às especificidades dos diferentes sons. Para além disso, motivados pela escassez de dados para o Português Europeu (PE), constitui-se como objetivo a obtenção de dados articulatórios que permitam complementar informação já existente e clarificar algumas questões relativas à produção dos sons do PE (nomeadamente, consoantes laterais e vogais nasais). Assim, para as consoantes laterais foram obtidas imagens RM (2D e 3D), através de produções sustidas, com recurso a uma sequência Eco de Gradiente (EG) rápida (3D VIBE), no plano sagital, englobando todo o trato vocal. O corpus, adquirido por sete falantes, contemplou diferentes posições silábicas e contextos vocálicos. Para as vogais nasais, foram adquiridas, em três falantes, imagens em tempo real com uma sequência EG - Spoiled (TurboFLASH), nos planos sagital e coronal, obtendo-se uma resolução temporal de 72 ms (14 frames/s). Foi efetuada aquisição sincronizada das imagens com o sinal acústico mediante utilização de um microfone ótico. Para o processamento e análise de imagem foram utilizados vários algoritmos semiautomáticos. O tratamento e análise dos dados permitiu efetuar uma descrição articulatória das consoantes laterais, ancorada em dados qualitativos (e.g., visualizações 3D, comparação de contornos) e quantitativos que incluem áreas, funções de área do trato vocal, extensão e área das passagens laterais, avaliação de efeitos contextuais e posicionais, etc. No que respeita à velarização da lateral alveolar /l/, os resultados apontam para um /l/ velarizado independentemente da sua posição silábica. Relativamente ao /L/, em relação ao qual a informação disponível era escassa, foi possível verificar que a sua articulação é bastante mais anteriorizada do que tradicionalmente descrito e também mais extensa do que a da lateral alveolar. A resolução temporal de 72 ms conseguida com as aquisições de RM em tempo real, revelou-se adequada para o estudo das características dinâmicas das vogais nasais, nomeadamente, aspetos como a duração do gesto velar, gesto oral, coordenação entre gestos, etc. complementando e corroborando resultados, já existentes para o PE, obtidos com recurso a outras técnicas instrumentais. Para além disso, foram obtidos novos dados de produção relevantes para melhor compreensão da nasalidade (variação área nasal/oral no tempo, proporção nasal/oral). Neste estudo, fica patente a versatilidade e potencial da RM para o estudo da produção de fala, com contributos claros e importantes para um melhor conhecimento da articulação do Português, para a evolução de modelos de síntese de voz, de base articulatória, e para aplicação futura em áreas mais clínicas (e.g., perturbações da fala).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Between the Bullet and the Hole is a film centred on the elusive and complex effects of war on women's role in ballistic research and early computing. The film features new and archival high-speed bullet photography, schlieren and electric spark imagery, bullet sound wave imagery, forensic ballistic photography, slide rulers, punch cards, computer diagrams, and a soundtrack by Scanner. Like a frantic animation storyboard, it explores the flickering space between the frames, testing the perceptual mechanics of visual interpolation, the possibility of reading or deciphering the gap between before and after. Interpolation - the main task of the women studying ballistics in WW2 - is the construction or guessing of missing data using only two known data points. The film tries to unpack this gap, open it up to interrogation. It questions how we read, interpolate or construct the gaps between bullet and hole, perpetrator and victim, presence and absence. The project involves exchanges with specialists in this area such as the Cranfield University Forensics department, London-based Forensic Firearms consultancy, the Imperial War Museum, the ENIAC programmers project, the Smithsonian Institute, and Forensic Scientists at Palm Beach County Sheriff's Office (USA). Exhibitions: Solo exhibition at Dallas Contemporary (Texas, Jan-Mar 2016), including newly commissioned lenticular prints and a dual slide projector installation; Group exhibition the Sydney Biennale (Sydney, Mar-June 2016); UK premiere and solo retrospective screening at Whitechapel Gallery (London); forthcoming solo exhibition at Iliya Fridman Gallery (NY, Oct-Dec 2016); Film festivals and screenings: International Film Festival Rotterdam (Jan 2016); Whitechapel Gallery (London Feb 2016); Cornerhouse/Home (Manchester Nov 2016); Public lectures: Whitechapel Gallery with prof. David Alan Grier and Morgan Quaintance; Carriageworks (Sydney) Prof. Douglas Khan; Monash University (Melbourne); Gertrude Space (Melbourne). Reviews and interviews: Artforum, Studio International, Mousse Magazine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La construction dans l’Arctique nécessite une connaissance précise des propriétés thermiques et géotechniques du pergélisol. La connaissance de ces propriétés est également nécessaire pour le paramétrage des modèles de transfert de chaleur. Des études antérieures ont démontré le grand potentiel de l’utilisation de la tomodensitométrie pour les mesures du volume des composantes du pergélisol et la visualisation de la cryostructure. Une nouvelle approche est proposée pour mesurer la conductivité thermique du pergélisol. Les objectifs généraux de ce projet sont (1) d’élaborer une nouvelle méthode de caractérisation du pergélisol à l’aide de la tomodensitométrie et de modèle éprouvés et (2) de comparer et mettre au point une méthode novatrice pour mesurer la conductivité thermique et des paramètres géotechniques. Les résultats démontrent que les tests effectués à l’aide de la tomodensitométrie donnent des résultats d’une valeur scientifique comparable aux autres méthodes existantes de mesure de déjà existantes de conductivité thermique du pergélisol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de doutoramento, Medicina Dentária (Medicina Dentária Preventiva e Comunitária), Universidade de Lisboa, Faculdade de Medicina Dentária, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de mestrado integrado em Engenharia Biomédica e Biofísica, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2015

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentada ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Marketing Digital, sob orientação de Doutor José Freitas Santos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oceans - San Diego, 2013

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Mestrado Integrado em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE-We studied whether manganese-enhanced high-field magnetic resonance (MR) imaging (MEHFMRI) could quantitatively detect individual islets in situ and in vivo and evaluate changes in a model of experimental diabetes.RESEARCH DESIGN AND METHODS-Whole pancreata from untreated (n = 3), MnCl(2) and glucose-injected mice (n = 6), and mice injected with either streptozotocin (STZ; n = 4) or citrate buffer (n = 4) were imaged ex vivo for unambiguous evaluation of islets. Exteriorized pancreata of MnCl(2) and glucose-injected mice (n = 6) were imaged in vivo to directly visualize the gland and minimize movements. In all cases, MR images were acquired in a 14.1 Testa scanner and correlated with the corresponding (immuno)histological sections.RESULTS-In ex vivo experiments, MEHFMRI distinguished different pancreatic tissues and evaluated the relative abundance of islets in the pancreata of normoglycemic mice. MEHFMRI also detected a significant decrease in the numerical and volume density of islets in STZ-injected mice. However, in the latter measurements the loss of beta-cells was undervalued under the conditions tested. The experiments on the externalized pancreata confirmed that MEHFMRI could visualize native individual islets in living, anesthetized mice.CONCLUSIONS-Data show that MEHFMRI quantitatively visualizes individual islets in the intact mouse pancreas, both ex vivo and in vivo. Diabetes 60:2853-2860, 2011

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Messages à retenir: L'identification des anomalies pleurales et parenchymateuses liées à une exposition à l'amiante est essentielle pour la reconnaissance de maladie professionnelle, avec de lourdes conséquences économiques. Le scanner thoracique est l'outil le plus fiable de ce dépistage. La détection d'anomalies dans les régions basales et sous-pleurales doit conduire à la réalisation de coupes complémentaires en procubitus sur ces régions. Le diagnostic TDM des anomalies pleurales et parenchymateuses liées à l'amiante repose sur des critères diagnostiques et un vocabulaire précis. De nombreuses images pièges peuvent mimer des plaques ou une asbestose. Une bonne connaissance de l'anatomie de l'interface pleuro-parenchymateuse et des principaux diagnostics différentiels permet souvent de redresser le diagnostic. Résumé: Le scanner multicoupe est l'outil de référence pour le dépistage des pathologies pleurales et parenchymateuses liées à l'exposition à l'amiante. Le diagnostic de plaques pleurales repose sur une surélévation quadrangulaire et nette de l'interface pleuro-parenchymateuse, dans une ou des localisation(s) évocatrice(s). Les pièges responsables de fausses images de plaques sont nombreux : structures anatomiques et variantes de la normale, opacités postéro-basales liées à des troubles ventilatoires, sarcoïdose... Les plaques doivent être différenciées des autres anomalies pleurales bénignes pouvant être rencontrées dans ce contexte, mais non spécifiques d'une exposition à l'amiante : épaississements pleuraux diffus, fibrose de la plèvre viscérale, images en pieds de corneille. La reconnaissance d'une asbestose nécessite de s'affranchir de troubles ventilatoires liés à la déclivité ou à des contraintes mécaniques focales, chroniques, telles que des ostéophytes para-vertébraux. Les coupes en procubitus permettent d'affirmer l'existence d'une pathologie interstitielle débutante dans les régions sous-pleurales et basales. Des anomalies interstitielles isolées ne peuvent être attribuées à une asbestose, de même que des anomalies interstitielles non spécifiques, associées ou non à une pathologie diffuse fibrosante.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapport de Synthése : Introducfíon : la maladie diverticulaire est devenue un problème majeur de santé communautaire et occupe la cinquième place en termes de coûts des maladies digestives. La diverticulite représente sa complication la plus fréquente chez environ 20-25% des patients avec une maladie diverticulaire. Son taux de récidive après un premier épisode de diverticulite est estimé à 20%. Historiquement, il était accepté que le taux de complications et d'échec du traitement conservateur de la diverticulite soient plus élevés lors de récidive qu'après un épisode initial. Ceci a amené la communauté médicale ä un consensus qui est de proposer une sigmoidectomie élective suite à un 2ème épisode de diverticulite. De nouvelles données et réinterprétations de travaux antérieurs ont remis en question ce consensus. Par ces faits, les dernières recommandations de la société américaine de chirurgie colorectale restent encore évasives dues au manque d'évidence. Le but de cette thèse est de déterminer si la récidive de diverticulite a une présentation clinique et radiologique différente d'un épisode initiale et si le risque d'échec du traitement est réellement plus élevé. Méthode : étude rétrospective .de 271 patients consécutifs admis dans le service. de chirurgie viscérale CHUV pour diverticulite, confirmée par CT-scan, de 2001 à 2004. 202 patients présentaient un épisode initial (groupe I), et 69 une récidive (groupe R). Au total 20 paramètres cliniques et 15 radiologiques ont été analysés et comparés entre les 2 groupes, dont le taux de prise en charge chirurgicale, la présentation clinique initiale, la réponse au traitement, les complications, les paramètres de laboratoires, la présence de liquide libre, d'abcès ou de pneumopéritoine au scanner. Une analyse statistique univariée a été effectuée. Résultats : aucun des paramètres cliniques ou radiologiques n'étaient différents entre les deux groupes. Concernant la chirurgie, 15.8% des patients dans le groupe I ont nécessité une prise en charge chirurgicale à l'admission comparé à 5.8% dans le groupe R (p=0.04). Le taux d'échec du traitement conservateur dans les deux groupes était similaire (10.7% vs 10.0% ; p=0.84). Le taux de mortalité à 30 jours était de 3% dans le groupe I et 0% dans le groupe R (p= 0.34). Conclusion : selon les résultats de cette étude, la récidive de diverticulite n'entraîne pas plus de complications ni d'échec du traitement conservateur. De plus, le taux de prise en charge chirurgicale à l'admission du patient est moins fréquent en cas de récidive. Ces résultats remettent en questions le consensus actuel de prise en charge chirurgicale élective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a short history of the appraisal of laser scanner technologies in geosciences used for imaging relief by high-resolution digital elevation models (HRDEMs) or 3D models. A general overview of light detection and ranging (LIDAR) techniques applied to landslides is given, followed by a review of different applications of LIDAR for landslide, rockfall and debris-flow. These applications are classified as: (1) Detection and characterization of mass movements; (2) Hazard assessment and susceptibility mapping; (3) Modelling; (4) Monitoring. This review emphasizes how LIDARderived HRDEMs can be used to investigate any type of landslides. It is clear that such HRDEMs are not yet a common tool for landslides investigations, but this technique has opened new domains of applications that still have to be developed.