997 resultados para RGB-D image


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Échelle(s) : [1:563 000 environ]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Échelle(s) : [1:1 682 000 environ], Lieues comunes de France de 25 au degré, 20 [= 5,2 cm]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Échelle(s) : [Échelle non déterminable]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mon projet de recherche s'est articulé autour des arythmies supraventriculaires chez les patients adultes porteurs d'une cardiopathie congénitale (Adults with Congenital Heart Disease ou ACHD). Grâce aux progrès de la chirurgie cardiaque et de la cardiologie, la survie à l'âge adulte des enfants nés avec une malformation cardiaque est excellente et la population des ACHD ne cesse de croître, tout en vieillissant. Les arythmies cardiaques sont une complication à long terme bien connue chez ces patients et une des principales causes de mortalité et de morbidité. Mon travail de recherche comporte une perspective épidémiologique avec une étude de population et une perspective anatomique, avec une étude d'imagerie cardiaque par échographie. 1. Étude épidémiologique : Arythmies auriculaires (AA) chez les patients porteurs d'une cardiopathie congénitale. Sous le titre anglais Atrial Arrhythmias in Adults with Congenital Heart Disease, cette étude a été publiée dans le journal américain Circulation. A travers les résultats de cette étude, j'ai démontré, pour la première fois dans une aussi grande population, que les AA étaient fréquentes chez les patients ACHD, que le risque à long-terme pour ces patients de développer des AA était élevé, et que le développement d'AA avait un impact négatif en termes de mortalité, de morbidité et d'intervention. 2. Étude anatomique : Les paramètres échographiques associés à la fibrillation auriculaire (FA) chez les patients adultes porteurs d'une cardiopathie congénitale. Sous le titre anglais Mirror image atrial dilatation in Adult Patients with Atrial Fibrillation and Congenital Heart Disease, cette étude a été publiée dans le journal américain International Journal of Cardiology, j'ai démontré dans cette étude que les patients ACHD avec une pathologie isolée du coeur gauche présentaient une dilatation progressive de l'oreillette gauche (OG) lorsqu'ils développaient de la FA. Chez les patients avec une pathologie isolée du coeur droit, j'ai décrit une image « miroir » : l'oreillette droite (OD) était toujours plus grande que l'OG βί présentait une dilatation progressive lors de FA. Ces résultats soutiennent l'hypothèse que la FA pourrait provenir de l'OD dilatée chez les patients ACHD avec une pathologie du coeur droit et ouvrent de nouvelles perspectives diagnostiques et thérapeutiques chez ces patients:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The trabecular bone score (TBS) is a gray-level textural metric that can be extracted from the two-dimensional lumbar spine dual-energy X-ray absorptiometry (DXA) image. TBS is related to bone microarchitecture and provides skeletal information that is not captured from the standard bone mineral density (BMD) measurement. Based on experimental variograms of the projected DXA image, TBS has the potential to discern differences between DXA scans that show similar BMD measurements. An elevated TBS value correlates with better skeletal microstructure; a low TBS value correlates with weaker skeletal microstructure. Lumbar spine TBS has been evaluated in cross-sectional and longitudinal studies. The following conclusions are based upon publications reviewed in this article: 1) TBS gives lower values in postmenopausal women and in men with previous fragility fractures than their nonfractured counterparts; 2) TBS is complementary to data available by lumbar spine DXA measurements; 3) TBS results are lower in women who have sustained a fragility fracture but in whom DXA does not indicate osteoporosis or even osteopenia; 4) TBS predicts fracture risk as well as lumbar spine BMD measurements in postmenopausal women; 5) efficacious therapies for osteoporosis differ in the extent to which they influence the TBS; 6) TBS is associated with fracture risk in individuals with conditions related to reduced bone mass or bone quality. Based on these data, lumbar spine TBS holds promise as an emerging technology that could well become a valuable clinical tool in the diagnosis of osteoporosis and in fracture risk assessment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents 3-D brain tissue classificationschemes using three recent promising energy minimizationmethods for Markov random fields: graph cuts, loopybelief propagation and tree-reweighted message passing.The classification is performed using the well knownfinite Gaussian mixture Markov Random Field model.Results from the above methods are compared with widelyused iterative conditional modes algorithm. Theevaluation is performed on a dataset containing simulatedT1-weighted MR brain volumes with varying noise andintensity non-uniformities. The comparisons are performedin terms of energies as well as based on ground truthsegmentations, using various quantitative metrics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Donateur : Reclus, Élisée (1830-1905)