Differences in levels of lignin in the plant between conventional and transgenic cultivars RR has been reported by several authors, however, there are few studies evaluating the influence of spraying of glyphosate on the lignin in the plant and RR soybean seeds. The aim of this study was to evaluate the physiological quality of RR transgenic soybean seeds and the lignin contents of plants sprayed with the herbicide glyphosate. The assays were conducted both in greenhouse and field in the municipality of Lavras, MG, in the agricultural year 2007/08. The experiment was arranged in a splitplot design with four replicates, considering the treatments hand weeding and herbicide glyphosate as plots, and five RR soybean cultivars (BRS 245 RR, BRS 247 RR, Valiosa RR, Silvânia RR and Baliza RR) as splitplots. In the greenhouse, the cultivars tested were BRS 245 RR and Valiosa RR in a randomized block design with four replicates. The sprayings were carried out at stages V3, V7 and early R5 (3L/ha). The 1000 seed weight, mechanical injury, germination and germination velocity index, emergence velocity index, accelerated aging, electrical conductivity and water soaking seed test, lignin content in the seed coat, in the stem and legumes were determined. The spraying of glyphosate herbicide, in greenhouse and field, did not alter the physiological quality of seeds and the lignin contents in the plant.
Resumo:
Myocardial perfusion-gated-SPECT (MP-gated-SPECT) imaging often shows radiotracer uptake in abdominal organs. This accumulation interferes frequently with qualitative and quantitative assessment of the infero-septal region of myocardium. The objective of this study is to evaluate the effect of ingestion of different fat content on the reduction of extra-myocardial uptake and to improve MP-gated-SPECT image quality. In this study, 150 patients (65 ^ 18 years) who were referred for MP-gated-SPECT underwent a 1-day-protocol including imaging after stress (physical or pharmacological) and resting conditions. All patients gave written informed consent. Patients were subdivided into five groups: GI, GII, GIII, GIV and GV. In the first four groups, patients ate two chocolate bars with different fat content. Patients in GV – control group (CG) – had just water. Uptake indices (UI) of myocardium (M)/liver(L) and M/stomach–proximal bowel(S) revealed lower UI of M/S at rest in all groups. Both stress and rest studies using different food intake indicate that patients who ate chocolate with different fat content showed better UI of M/L than the CG. The UI of M/L and M/S of groups obtained under physical stress are clearly superior to that of groups obtained under pharmacological stress. These differences are only significant in patients who ate high-fat chocolate or drank water. The analysis of all stress studies together (GI, GII, GIII and GIV) in comparison with CG shows higher mean ranks of UI of M/L for those who ate high-fat chocolate. After pharmacological stress, the mean ranks of UI of M/L were higher for patients who ate high- and low-fat chocolate. In conclusion, eating food with fat content after radiotracer injection increases, respectively, the UI of M/L after stress and rest in MP-gated-SPECT studies. It is, therefore, recommended that patients eat a chocolate bar after radiotracer injection and before image acquisition.
Resumo:
This study aims to optimize the water quality monitoring of a polluted watercourse (Leça River, Portugal) through the principal component analysis (PCA) and cluster analysis (CA). These statistical methodologies were applied to physicochemical, bacteriological and ecotoxicological data (with the marine bacterium Vibrio fischeri and the green alga Chlorella vulgaris) obtained with the analysis of water samples monthly collected at seven monitoring sites and during five campaigns (February, May, June, August, and September 2006). The results of some variables were assigned to water quality classes according to national guidelines. Chemical and bacteriological quality data led to classify Leça River water quality as “bad” or “very bad”. PCA and CA identified monitoring sites with similar pollution pattern, giving to site 1 (located in the upstream stretch of the river) a distinct feature from all other sampling sites downstream. Ecotoxicity results corroborated this classification thus revealing differences in space and time. The present study includes not only physical, chemical and bacteriological but also ecotoxicological parameters, which broadens new perspectives in river water characterization. Moreover, the application of PCA and CA is very useful to optimize water quality monitoring networks, defining the minimum number of sites and their location. Thus, these tools can support appropriate management decisions.
Resumo:
Despite all efforts to store and reduce its consumption, water is becoming less inexhaustible and its quality is falling faster. Considering that water is essential to animal life, it is necessary to adopt measures to ensure its sanitary conditions in order to be fit for consumption. The aim of this study was to analyze the microbiological quality of drinking rainwater used by rural communities of Tuparetama, a small town located in Northeast Brazil. The study covered seven rural communities, totaling 66 households. In each household two samples were collected, one from a tank and the other from a clay pot located inside the home, resulting in 132 samples (tank plus clay pot). Approximately 90% of samples were below the standard recommended by the current legislation, being considered unfit for human consumption. Part of this high microbiological contamination of drinking rainwater could be related to the lack of sanitary education and of an adequate sewerage sanitation system.
Resumo:
In order to address and resolve the wastewater contamination problem of the Sines refinery with the main objective of optimizing the quality of this stream and reducing the costs charged to the refinery, a dynamic mass balance was developed nd implemented for ammonia and polar oil and grease (O&G) contamination in the wastewater circuit. The inadequate routing of sour gas from the sour water stripping unit and the kerosene caustic washing unit, were identified respectively as the major source of ammonia and polar substances present in the industrial wastewater effluent. For the O&G content, a predictive model was developed for the kerosene caustic washing unit, following the Projection to Latent Structures (PLS) approach. Comparison between analytical data for ammonia and polar O&G concentrations in refinery wastewater originating from the Dissolved Air Flotation (DAF) effluent and the model predictions of the dynamic mass balance calculations are in a very good agreement and highlights the dominant impact of the identified streams for the wastewater contamination levels. The ammonia contamination problem was solved by rerouting the sour gas through an existing clogged line with ammonia salts due to a non-insulated line section, while for the O&G a dynamic mass balance was implemented as an online tool, which allows for prevision of possible contamination situations and taking the required preventive actions, and can also serve as a basis for establishing relationships between the O&G contamination in the refinery wastewater with the properties of the refined crude oils and the process operating conditions. The PLS model developed could be of great asset in both optimizing the existing and designing new refinery wastewater treatment units or reuse schemes. In order to find a possible treatment solution for the spent caustic problem, an on-site pilot plant experiments for NaOH recovery from the refinery kerosene caustic washing unit effluent using an alkaline-resistant nanofiltration (NF) polymeric membrane were performed in order to evaluate its applicability for treating these highly alkaline and contaminated streams. For a constant operating pressure and temperature and adequate operating conditions, 99.9% of oil and grease rejection and 97.7% of chemical oxygen demand (COD) rejection were observed. No noticeable membrane fouling or flux decrease were registered until a volume concentration factor of 3. These results allow for NF permeate reuse instead of fresh caustic and for significant reduction of the wastewater contamination, which can result in savings of 1.5 M€ per year at the current prices for the largest Portuguese oil refinery. The capital investments needed for implementation of the required NF membrane system are less than 10% of those associated with the traditional wet air oxidation solution of the spent caustic problem. The operating costs are very similar, but can be less than half if reusing the NF concentrate in refinery pH control applications. The payback period was estimated to be 1.1 years. Overall, the pilot plant experimental results obtained and the process economic evaluation data indicate a very competitive solution through the proposed NF treatment process, which represents a highly promising alternative to conventional and existing spent caustic treatment units.
Resumo:
Chlorine is the most commonly used agent for general disinfection, particularly for microbial growth control in drinking water distribution systems. The goals of this study were to understand the effects of chlorine, as sodium hypochlorite (NaOCl), on bacterial membrane physicochemical properties (surface charge, surface tension and hydrophobicity) and on motility of two emerging pathogens isolated from drinking water, Acinetobacter calcoaceticus and Stenotrophomonas maltophilia. The effects of NaOCl on the control of single and dual-species monolayer adhered bacteria (2 h incubation) and biofilms (24 h incubation) was also assessed. NaOCl caused significant changes on the surface hydrophobicity and motility of A. calcoaceticus, but not of S. maltophilia. Planktonic and sessile S. maltophilia were significantly more resistant to NaOCl than A. calcoaceticus. Monolayer adhered co-cultures of A. calcoaceticus-S. maltophilia were more resilient than the single species. Oppositely, dual species biofilms were more susceptible to NaOCl than their single species counterparts. In general, biofilm removal and killing demonstrated to be distinct phenomena: total bacterial viability reduction was achieved even if NaOCl at the higher concentrations had a reduced removal efficacy, allowing biofilm reseed. In conclusion, understanding the antimicrobial susceptibility of microorganisms to NaOCl can contribute to the design of effective biofilm control strategies targeting key microorganisms, such as S. maltophilia, and guarantying safe and high-quality drinking water. Moreover, the results reinforce that biofilms should be regarded as chronic contaminants of drinking water distribution systems and accurate methods are needed to quantify their presence as well as strategies complementary/alternative to NaOCl are required to effectively control the microbiological quality of drinking water.
Resumo:
A sample of about 70 young bulls of each of ten beef cattle breeds reared in their typical production systems has been characterised with respect to meat quality traits. Breeds included were Asturiana de los Valles, Asturiana de la Montaña, Avileña-Negra Ibérica, Bruna dels Pirineus, Morucha, Pirenaica and Retinta from Spain, and Aubrac, Gasconne and Salers from France. As was previously showed regarding carcass traits, there exist large differences both between and within breed – systems. In general, rustic breeds tended to present darker and redder meats with higher haematin contents, whereas less precocious and more specialised breeds showed brighter meats with bigger water losses. Protein content was similar, whereas intramuscular fat presented the larger variations both between and within breeds. ICDH content was higher in the more rustic breeds, showing the predominantly oxidative character of their fibres. Texture measurements showed in general large within breed-system variations, the differences between breeds being less evident. Within breed-system, daily gain weight was positively associated with brighter and tender meats. In the range studied, increasing slaughter weight within breed did not have influence on meat quality. Conformation was related to lower water holding capacity and less dry matter and intramuscular fat, as well as to a lower haematin content giving brighter meats. The increase in fatness scores was related to an augment of toughness in meat specialised breeds, although in Avileña-Negra Ibérica breed fatness carcasses were related to more tender meats. Redness parameter a* was positively related to fatter animals and opposed to conformation, the opposite being true for the L* (lightness) parameter. There was a small trend of fatter carcasses to be related to oxidative fibres, whereas the muscular fibres of the more conformed carcasses were more glycolytic. Texture measurements maximum load, maximum stress and toughness were very closely related. Shear force was opposed to tenderness. Losses at cooking were opposed to juiciness, but only in the Spanish breeds. No consistent trends regarding relationships between carcass characteristics and tenderness could be observed. Overall acceptability was primarily related with tenderness and flavour, and later on juiciness.
Resumo:
Sixty-nine entire male pigs with different halothane genotype (homozygous halothane positive – nn –, n=36; and homozygous halothane negative – NN-, n=33) were fed with a supplementation of magnesium sulphate (Mg) and/or L-tryptophan (Trp) in the diet for 5 days before slaughter. Animals were housed individually and were submitted to stressful ante mortem conditions (mixed in the lorry according to treatments and transported 1 hour on rough roads). Individual feed intake was recorded during the 5-d treatment. At the abattoir, pig behaviour was assessed in the raceway to the stunning system and during the stunning period by exposure to CO2. Muscle pH, colour, water holding capacity, texture and cathepsin activities were determined to assess meat quality. The number of pigs with an individual feed intake lower than 2 kg/d was significantly different among diets (P&0.05; Control: 8.7 %; Mg&Trp: 43.5 %; Trp: 17.4 %) and they were considered to have inadequate supplement intake. During the ante mortem period, 15.2 % of pigs included in the experiment died, and this percentage decreased to 8.7 % in those pigs with a feed intake & 2kg/day, all of them from the stress-sensitive pigs (nn). In general, no differences were observed in the behaviour of pigs along the corridor leading to the stunning system and inside the CO2 stunning system. During the stunning procedure, Trp diet showed shorter periods of muscular excitation than control and Mg&Trp diets. The combination of a stressful ante mortem treatment and Mg&Trp supplementation led to carcasses with high incidence of severe skin lesions. Different meat quality results were found when considering all pigs or considering only those with adequate supplement intake. In this later case, Trp increased pH45 (6.15) vs Control diet (5.96) in the Longissimus thoracis (LT) muscle (P&0.05) and pH at 24h (Trp: 5.59 vs C: 5.47) led to a higher incidence of dark, firm and exudative (DFD) traits in SM muscle (P&0.05). Genotype affected negatively all the meat quality traits. Seventy-five percent of LT and 60.0 % of the SM muscles from nn pigs were classified as pale, soft and exudative (PSE), while none of the NN pigs showed these traits (P&0.0001). No significant differences were found between genotypes on the incidence of DFD meat. Due to the negative effects observed in the Mg&Trp group in feed intake and carcass quality, the utilization of a mixture of magnesium sulphate and tryptophan is not recommended.
Resumo:
Candida parapsilosis, currently divided into three distinct species, proliferates in glucose-rich solutions and has been associated with infections resulting from the use of medical devices made of plastic, an environment common in dialysis centres. The aims of this study were (i) to screen for Candida orthopsilosis and Candida metapsilosis (100 environmental isolates previously identified as C. parapsilosis), (ii) to test the ability of these isolates to form biofilm and (iii) to investigate the in vitro susceptibility of Candida spp biofilms to the antifungal agents, fluconazole (FLC) and amphotericin B (AMB). Isolates were obtained from a hydraulic circuit collected from a haemodialysis unit. Based on molecular criteria, 47 strains were re-identified as C. orthopsilosis and 53 as C. parapsilosis. Analyses using a formazan salt reduction assay and total viable count, together with microscopy studies, revealed that 72 strains were able to form biofilm that was structurally similar, but with minor differences in morphology. A microtitre-based colorimetric assay used to test the susceptibility of fungal biofilms to AMB and FLC demonstrated that the C. parapsilosis complex displayed an increased resistance to these antifungal agents. The results from these analyses may provide a basis for implementing quality controls and monitoring to ensure the microbiological purity of dialysis water, including the presence of yeast.
Resumo:
History has taken its toll on Muchakinock Creek. A number of problems over the years have led to the stream’s current state, one that’s landed it on Iowa’s list of impaired waters. However, the stream is also full of opportunity. The opportunity to improve water quality not only for the aquatic life and wildlife that live there, but also to pass along clean water to future generations of Iowans. But to act on this opportunity, we need your help.
Resumo:
The aim of our survey was to assess the effect of irrigation water of the microbiological quality on the production chain of lettuce in the Dakar area. Microbiological analysis showed that 35% of irrigation water was contaminated by Salmonella spp. between the two water-types used for irrigation (groundwater and wastewater), no significant difference (p>0.05) in their degree of contamination was found. The incidence of different types of irrigation water on the contamination rate of lettuces from the farm (Pikine and Patte d'Oie) was not different either (p>0.05). However, the contamination rate of lettuce from markets of Dalifort and Grand-Yoff that were supplied by the area of Patte d'Oie was greater than those of Sham and Zinc supplied by Pikine (p<0.05). Comparison of serotypes of Salmonella isolated from irrigation water and lettuce showed that irrigation water may affect the microbiological quality of lettuce. Manures, frequently used as organic amendment in cultivating lettuce are another potential source of contamination. These results showed that lettuce may constitute effective vectors for the transmission of pathogens to consumers. Extensive treatment of the used wastewater and/or composting of manure could considerably reduce these risks.
Resumo:
The intensive use of land alters the distribution of the pore size which imparts consequences on the soil physical quality. The Least Limiting Water Range (LLWR) allows for the visualization of the effects of management systems upon either the improvement or the degradation of the soil physical quality. The objective of this study was to evaluate the physical quality of a Red Latosol (Oxisol) submited to cover crops in the period prior to the maize crop in a no-tillage and conventional tillage system, using porosity, soil bulk density and the LLWR as attributes. The treatments were: conventional tillage (CT) and a no-tillage system with the following cover crops: sunn hemp (Crotalaria juncea L.) (NS), pearl millet (Pennisetum americanum (L.) Leeke) (NP) and lablab (Dolichos lablab L.) (NL). The experimental design was randomized blocks in subdivided plots with six replications, with the plots being constituted by the treatments and the subplots by the layers analyzed. The no-tillage systems showed higher total porosity and soil organic matter at the 0-0.5 m layer for the CT. The CT did not differ from the NL or NS in relation to macroporosity. The NP showed the greater porosity, while CT and NS presented lower soil bulk density. No < 10 % airing porosity was found for the treatments evaluated, and value for water content where soil aeration is critical (θPA) was found above estimated water content at field capacity (θFC) for all densities. Critical soil bulk density was of 1.36 and 1.43 Mg m-3 for NP and CT, respectively. The LLWR in the no-tillage systems was limited in the upper part by the θFC, and in the bottom part, by the water content from which soil resistance to penetration is limiting (θPR). By means of LLWR it was observed that the soil presented good physical quality.
Resumo:
The no-till system with complex cropping sequences may improve the structural quality and carbon (C) sequestration in soils of the tropics. Thus, the objective of this study was to evaluate the effects of cropping sequences after eight years under the no-till system on the physical properties and C sequestration in an Oxisol in the municipality of Jaboticabal, Sao Paulo, Brazil. A randomized split-block design with three replications was used. The treatments were combinations of three summer cropping sequences - corn/corn (Zea mays L.) (CC), soybean/soybean (Glycine max L. Merryll) (SS), and soybean-corn (SC); and seven winter crops - corn, sunflower (Helianthus annuus L.), oilseed radish (Raphanus sativus L.), pearl millet (Pennisetum americanum (L.) Leeke), pigeon pea (Cajanus cajan (L.) Millsp), grain sorghum (Sorghum bicolor (L.) Moench), and sunn hemp (Crotalaria juncea L.). Soil samples were taken at the 0-10 cm depth after eight years of experimentation. Soil under SC and CC had higher mean weight diameter (3.63 and 3.55 mm, respectively) and geometric mean diameter (3.55 and 2.92 mm) of the aggregates compared to soil under SS (3.18 and 2.46 mm). The CC resulted in the highest soil organic C content (17.07 g kg-1), soil C stock (15.70 Mg ha-1), and rate of C sequestration (0.70 Mg ha-1 yr-1) among the summer crops. Among the winter crops, soil under pigeon pea had the highest total porosity (0.50 m³ m-3), and that under sunn hemp had the highest water stable aggregates (93.74 %). In addition, sunn hemp did not differ from grain sorghum and contained the highest soil organic C content (16.82 g kg-1) and also had the highest rate of C sequestration (0.67 Mg ha-1 yr-1). The soil resistance to penetration was the lower limit of the least limiting water range, while the upper limit was air-filled porosity for soil bulk densities higher than 1.39 kg dm-3 for all cropping sequences. Within the SC sequence, soil under corn and pigeon pea increased least limiting water range by formation of biopores because soil resistance to penetration decreased with the increase in soil bulk density.
Resumo:
Many soils have a hard-setting behavior, also known as cohesive or "coesos". In such soils, the penetration resistance increases markedly when dry and decreases considerably when moist, creating serious limitations for plant emergence and growth. To evaluate the level of structure degradation in hard-setting soils with different texture classes and to create an index for assessing soil hardness levels in hard-setting soils, six soil representative profiles were selected in the field in various regions of Brazil. The following indices were tested: S, which measures soil physical quality, and H , which analyzes the degree of hardness and the effective stress in the soil during drying. Both indices were calculated using previously described functions based on data from the water-retention curves for the soils. The hard-setting values identified in different soils of the Brazilian Coastal Tablelands have distinct compaction (hardness) levels and can be satisfactorily measured by the H index. The S index was adequate for evaluating the structural characteristics of the hard-setting soils, classifying them as suitable or poor for cultivation, but only when the moisture level of the soil was near the inflection point. The H index showed that increases in density in hard-setting soils result from increases in effective stress and not from the soil texture. Values for Bd > 1.48 kg dm-3 classify the soil as hard-setting, and the structural organization is considered "poor".
Resumo:
In an era of increasing concern for limited water resources a wise joint management of conventional and nonconventional water resources must be considered. Water scarcity aggravates in coastal zones which are often characterised by high population density, intense economic activity and tourism; meaning heavy seasonal water demands. The relationships between sea and land-water can also compromise the quality of available freshwater. In this context, the use of non-conventional water increases the availability of water supplies. Non-conventional water resources of low quality could be directed to meet several needs (like watering lawns, washing cars, flushing toilets and cooling systems, among others). Therefore, significantly more potable water would be available to meet human demand for safe water.