856 resultados para Poland - Warsaw


Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the parasite fauna investigation within 2004 and 2005, the freshwater fish trypanosomes were isolated from the blood of dark sleeper (Odontobutis obscura Temminck and Schlegel) and snakehead fish (Ophiocephalus argus Cantor) from Niushan Lake, Hubei Province, China. Blood trypomastigotes were used for light microscopy investigations. The detailed descriptions of three morphological groups of the genus Trypanosoma: Trypanosoma sp. I and Trypanosoma sp. II found in blood of O. obscura, and Trypanosoma sp. III found in blood of O. argus were provided. Morphological features and host species show Trypanosoma sp. III belong to Trypanosoma ophiocephali Chen 1964, an incompletely described species. Infection with trypanosomes of O. obscura was recorded for the first time. According to the size and appearance, the trypanosomes in O. obscura were also tentatively identified as T. ophiocephali Chen 1964.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this letter, we have demonstrated continuous-wave single-mode operation of 1.3-mu m InAs-GaAs quantum-dot (QD) vertical-cavity surface-emitting lasers (VCSELs) with p-type modulation-doped QD active region from 20 degrees C to 60 degrees C. The highest output power of 0.435mW and lowest threshold current of 1.2 mA under single-mode operation are achieved. The temperature-dependent output characteristics of QD-VCSELs are investigated. Single-mode operation with a sidemode suppression ratio of 34 dB is observed at room temperature. The critical size of oxide aperture for single-mode operation is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the fabrication of 1.3 mu m waveband p-doped InAs quantum dot (QD) vertical cavity surface emitting lasers (VCSELs) with an extremely simple process. The continuous-wave saturated output power of 1.1 mW with a lasing wavelength of 1280 nm is obtained at room temperature. The high-speed modulation characteristics of p-doped QD VCSELs of two different oxide aperture sizes are investigated and compared. The maximum 3 dB modulation bandwidth of 2.5 GHz can be achieved at a bias current of 7 mA for a p-doped QD VCSEL with an oxide aperture size of 10 mu m in the small signal frequency response measurements. The crucial factors for the 3 dB bandwidth limitation are discussed according to the parameters' extraction from frequency response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The vertical radiation loss of three-dimensional (3-D) microresonators is investigated by 3-D finite-difference time-domain (FDTD) simulation. The simulation shows that the vertical radiation causes an important loss in the microresonators with weak waveguiding, and result in decrease of the quality factors (Q-factors) of whispering-gallery (WG) modes. Through the simulation, we find that TM-like modes have much weaker vertical radiation loss than TE-like modes. High Q-factor TM-like modes are observed in the 3-D microresonators with weak vertical waveguiding, but the Q-factors of TE-like modes decrease greatly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Equilateral-triangle-resonator (ETR) microlasers with an output waveguide connected to one of the vertices of the ETR are fabricated using standard photolithography and inductively-coupled-plasma etching techniques. Continuous-wave electrically injected 1550 nm ETR laser with side length ranged from 15 to 30 tm are realized at room temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wide transmission dips are observed in the through spectra in microring and racetrack channel drop filters by two-dimensional finite-difference time-domain (FDTD) simulation. The transmission spectra, which reflect the coupling efficiency, are also calculated from the FDTD output as the pulse just travels one circle inside the resonator. The results indicate that the dips are caused by the dispersion of the coupling coefficient between the input waveguide and the resonator. In addition, a near-zero channel drop on resonance and a large channel drop off resonance are observed due to the near zero coupling coefficient and a large coupling coefficient, respectively. If the width of the input waveguide is different from that of the ring resonator, the oscillation of the coupling coefficient can be greatly suppressed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thin films of TiO2 doped by Mn non-uniformly were prepared by sol-gel method under process control. In our preceding study, we investigated in detail, the effect of doping mode on the photocatalytic activity of TiO2 films showing that Mn non-uniform doping can greatly enhance the activity. In this study we looked at the effect of doping concentration on the photocatalytic activity of the TiO2 films. In this paper, the thin films were characterized by UV-vis spectrophotometer and electrochemical workstation. The activity of the photocatalyst was also evaluated by photocatalytic degradation rate of aqueous methyl orange under UV radiation. The results illustrate that the TiO2 thin film doped by Mn non-uniformly at the optimal dopant concentration (0.7 at %) is of the highest activity, and on the contrary, the activity of those doped uniformly is decreased. As a comparison, in 80 min, the degradation rate of methyl orange is 62 %, 12 % and 34 % for Mn non-uniform doping film (0.7 at %), the uniform doping film (0.7 at %) and pure titanium dioxide film, respectively. We have seen that, for the doping and the pure TiO2 films, the stronger signals of open circuit potential and transient photocurrent, the better photocatalytic activity. We also discusse the effect of dopant concentration on the photocatalytic activity of the TiO2 films in terms of effective separation of the photon-generated carriers in the semiconductor. (C) Versita Warsaw and Springer-Verlag Berlin Heidelberg. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ability of the Evpatoria RT-70 radar complex to perform research on space debris was investigated in four trial experiments during 2001-2003. The echo-signals of 25 objects at geostationary, highly elliptical and medium-altitude orbits were recorded on magnetic tapes at radio telescopes in Russia, Italy, China and Poland. The multi-antenna system configuration gives potential to supplement the classic radar data with precise angular observations using the technique of Very Long Baseline Interferometry. The first stage of such processing was fulfilled by the correlator in N. Novgorod, Russia. The cross-correlation of transmitted and received signals was obtained for the 11 objects on the Evpatoria-Bear Lakes, Evpatoria-Urumqi and Evpatoria-Noto baselines. This activity also promoted developing the optical observations of geostationary objects, conducted for the improvement of the radar target ephemerides. (C) 2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of optical network demands integrated arid multiple functionality modules to lowing cost and acquire highly reliability. Among the various contender materials to be photonic integrated circuits platform, silicon exhibits dominant characteristics and is the most promising platform materials. The paper compares the characteristics of some candidate materials with silicon and reviews recent progress in silicon based photonic integration technology. Tile challenges to silicon for optical integration for optical networking application arc also indicated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Microphotoluminescence (mu-PL) investigation has been performed at room temperature on InAs quantum dot (QD) vertical cavity surface emitting laser (VCSEL) structure in order to characterize the QD epitaxial structure which was designed for 1.3 mu m wave band emission. Actual and precise QD emission spectra including distinct ground state (GS) and excited state (ES) transition peaks are obtained by an edge-excitation and edge-emission (EEEE) mu-PL configuration. Conventional photoluminescence methods for QD-VCSELs structure analysis are compared and discussed, which indicate the EEEE mu-PL is a useful tool to determine the optical features of the QD active region in an as-grown VCSEL structure. Some experimental results have been compared with simulation results obtained with the aid of the plane-wave admittance method. After adjustment of epitaxial growth according to EEEE mu-PL measurement results, QD-VCSEL structure wafer with QD GS transition wavelength of 1300 nm and lasing wavelength of 1301 nm was obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. the skin neurogenic inflammation is mainly related to Substance P (SP) and Calcitonin Gene-related Peptide (CGRP). There is no data on their availability in the dynamics of skin nerve endings, concerning their release and replenishment after a nociceptive stimulus, so this was investigated. Materials and methods. 25 rats were randomly distributed in 5 groups. the animals of the control group (CG) determined the baseline levels of neuropeptides in the skin. the groups S0 and S30 did not receive any cutaneous stimulus at 30 and 60 minutes, respectively. in the group S1, an incision stimulus was made at 30 minutes. in the group S31, a nociceptive stimulus was performed by subdermal scratching at 30 minutes and, at 60 minutes, the incision stimulus was carried out in the same location (nociceptive hyperstimulation). the skin samples of the other animals were harvested from the back 1 minute after their death. SP, pro-CGRP and CGRP were quantified by Western Blotting. Results. the incision stimulus released SP, S1 compared to S0 (p < 0.05) detected in the first minute, and the replenishment time was more than 30 minutes. Also, it cleaved pro-CGRP, S1 compared to S31 (p < 0.05) in the first minute, and its replenishment time less than 30 minutes. Release of CGRP was not detected. Conclusion. the incision released SP already detected in the first minute; its replenishment time is more than 30 minutes. the incision decreased pro-CGRP, also detected in the first minute; and its replenishment time is less than 30 minutes.