938 resultados para Percutaneous Ethanol Injection
Resumo:
The selected yeast strains were examined for their ability lo grow, to retain cell viability and to ferment diluted sugar cane juice (15% total sugar, w/v) to ethanol at 40-degrees-C. The degree of agitation (aeration) affects the thermotolerance while the method used for isolation of the strains appears to have no significant effect. The yeast isolated are aerobically fermentative with increased levels of fermentation and growth resulting from agitation (aeration), the exact level of these increases being dependent on the strain used.
Resumo:
A method based an ion exchange(IE)-atomic absorption spectrometry(AAS) coupled by flow techniques, allowing the determination of formation constants of, at least, the first species of complex systems, in aqueous solution, was developed.The IE-AAS coupling reduces significantly the number of experimental steps in comparison with IE batch methods, resulting in an important increase in analytical rate. The method is simple both from experimental and computational points of view, making possible its utilization by workers without special expertise in the field of complex equilibria in solution. on the other hand, taking into account mainly the amount of hollow cathode lamps available to date, the developed procedure may be applied, within certain limitations, to the study of many systems whose features prevent the use of traditional approaches.
Resumo:
An automatic Procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atonic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-element standard, an electrolytic cell equipped with two electrodes (a silver needle acts as cathode, and sample as anode), and an intelligent unit. The latter is assembled in a PC-compatible microcomputer for instrument control, and far data acquisition and processing. General management of the process is achieved by use of software written in Pascal. Electrolyte compositions, flow rates, commutation times, applied current and electrolysis time mere investigated. A 0.5 mol l(-1) HNO3 solution was elected as electrolyte and 300 A/cm(2) as the continuous current pulse. The performance of the proposed system was evaluated by analysing aluminium in Al-allay samples, and copper/zinc in brass and bronze samples, respectively. The system handles about 50 samples per hour. Results are precise (R.S.D < 2%) and in agreement with those obtained by ICP-AES and spectrophotometry at a 95% confidence level.
Resumo:
Purpose: To compare the safety and anti-inflammatory efficacy of a single posterior subtenon injection of triamcinolone acetonide (TA) with prednisolone acetate 1% eyedrops after pars plana vitrectomy (PPV).Methods: the study included 40 consecutive phakic eyes of 40 patients undergoing PPV for non-clearing vitreous haemorrhage with attached retina (verified by echography), epiretinal membrane or macular hole. At the end of the surgical procedure, eyes were randomized to receive either a single posterior subtenon injection of TA (40 mg in 1 ml) plus sham eyedrops (prednisolone acetate 1% vehicle) postoperatively (group TA), or a posterior subtenon sham injection (1 ml balanced salt solution) plus prednisolone acetate 1% eyedrops postoperatively (group ED).Results: There was no difference in the severity of anterior chamber cell and flare between the two groups at any time-point during the study period (p > 0.05). Separate within-group analysis revealed a significant decrease in anterior chamber cell and flare from postoperative day 1 to postoperative days 7, 14 and 28 in both groups (p < 0.05). There was no difference in pain, photophobia, conjunctival erythema, ciliary flush or chemosis scores between the two groups at any time-point during the study period (p > 0.05). Steroid-induced intraocular hypertension was not observed in either group.Conclusions: A single posterior subtenon injection of TA can be as effective and safe as a 4-week regimen of prednisolone acetate 1% eyedrops in controlling intraocular inflammation after PPV.
Resumo:
The changes of arterial pressure promoted by bolus injection of 50 mg phenylephrine (PHE) were studied in 20 atropinized patients (5 normal subjects, 13 patients with mitral valve disease, 1 patient with essential arterial hypertension and 1 patient with hypertrophic cardiomyopathy) submitted to routine catheterism. Patients with aortic valve disease, left ventricular outflow tract obstruction and intracardiac shunt were excluded from the study. All patients were in sinus rhythm, without heart failure. Arterial pressure started to increase at 14.8 +/- 5.4 s (range, 5.6 to 27 s; mean +/- SD) after PHE. There was an increase of 37.8 +/- 16.7 mmHg (range, 12.5 to 70 mmHg) in systolic pressure and of 26.6 +/- 11.1 mmHg (range, 7.5 to 42.5 mmHg) in diastolic pressure. Peak hypertension was attained at 36.6 +/- 16.4 s (range, 10.8 to 64.9 s) and hypertension continued for 176 +/- 92 s (range, 11 to 365 s). Heart rate was 114 +/- 21 bpm before PHE and 111 +/- 21 bpm (P<0.05) after PHE. There were no adverse events associated with intravenous PHE injection in any patient, in accordance with the general view that bolus injection of PHE is a safe and practical maneuver to promote arterial hypertension.
Resumo:
Statement of problem. A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing.Purpose. This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique.Material and methods. Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups.Results. A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used.Conclusion. The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.
Resumo:
The acid and ultrasound catalyzed hydrolysis of solventless TEOS-water mixtures are studied, as a function of the initial additions of ethanol to the mixtures, by means of flux calorimetry measurements. A device was specially designed for this purpose. Under acid conditions, our proposed method has been able to resolve hydrolysis from other condensation reactions, by detecting the exothermal hydrolysis reaction heat. The process has been explained by a dissolution and reaction mechanism. Ultrasound forces the dissolution process to start the reaction. The alcohol produced in the reaction helps the dissolution process to further enhance the hydrolysis. Initial amounts of pure ethanol added to the mixtures shorten the start time of the reaction, due to an additional effect of dissolution, and diminish the reaction rate, as a result of the solvent dilution effect. Our dissolution and reaction mechanism modeling describes the main points arising from the experimental data and yields k(H) = 0.24 M(-1) min(-1) for the second-order hydrolysis rate constant at 39 degrees C.
Resumo:
Background and Objectives. A combination of epidural and general anesthesia has been widely used to attenuate the surgical stress response and to provide postoperative analgesia. This case report illustrates the use of this anesthetic technique. Analgesia was induced with local anesthetic in the immediate postoperative period using unintentional 19.1% potassium chloride (KCI) as diluent. Methods. An ASA I male patient was scheduled for surgical correction of idiopathic megaesophagus under continuous epidural anesthesia combined with general anesthesia. In the postoperative period, while preparing 10 mt 0.125% bupivacaine to be administered through the epidural catheter for pain control, 5 mt 19.1% KCI was unintentionally used as diluent, resulting in a 9.55% potassium solution concentration. Results. The patient developed warmness of the lower limbs, tachycardia, hypertension, intense pruritus on the chest, agitation, exacerbation of sensory and motor blocks, and respiratory failure secondary to pulmonary edema, requiring ventilatory support. Total recovery was observed after 24 hours. Conclusions. Epidurally injected potassium leads to severe clinical manifestations caused by autonomic dysfunction, spinal cord irritation, and possible release of histamine. Despite continuous recommendations, ampule misidentification still happens in hospitals, frequently leading to serious accidents.
Resumo:
A flow-injection system for multielemental analysis with a mercury(II) preconcentration step using a resin Chelite-S(R)(Serva Feinbiochemica Heidelberg, Part No. 41709) packed minicolumn by inductively coupled plasma atomic emission spectroscopy is described. A mercury reductive elution procedure with a mixture of SnCl2/HCl was used, which allows use of 6 mol/L HCl solution instead of concentrated hydrochoric acid. The main parameters related to ICP operation, such as radio frequency power (950-1750 W), auxiliary argon flow (0.0-1.5 L/min) and spray chamber nebulizer pressure (15-35 psi), were studied. Optimization of the FIA system was reached by defining the best eluent carrier stream (1.4-2.8 mL/min), Hgdegrees carrier stream (10-40 mL min(-1)), loading time (0.5-4.0 min), sample flow rate (1.25-10.0 mL/min), temperature of reactor gas liquid separator (GLS) (25-75 degreesC) and eluent volume (50-350 muL). Throughput is around 30 samples per hour for analytical solutions within the range 50-2500 ng Hg(II)/L. Results from certified material showed good precision (RSD < 3%, n = 12) and no statistical difference was observed for real samples analyzed by AAS and by the proposed system.
Resumo:
Bismuth was evaluated as an internal standard for the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru as a permanent modifier with co-injection of Pd/Mg(NO3)(2). The correlation coefficient of the graph plotted from the non-nalized absorbance signals of Bi versus Pb was r=0.989. Matrix effects were evaluated by analyzing the slope ratios between the analytical curve, and analytical curves obtained from Pb additions in red and white wine vinegar obtained from reference solutions prepared in 0.2% (v/v) HNO3, samples. The calculated ratios were around 1.04 and 1.02 for analytical curves established applying an internal standard and 1.3 and 1.5 for analvtical curves without. Analytical curves in the 2.5-15 pg L-1 Pb concentration interval were established using the ratio Pb absorbance to Bi absorbance versus analvte concentration, and typical linear correlations of r=0.999 were obtained. The proposed method was applied for direct determination of Pb in 18 commercial vinegar samples and the Pb concentration varied from 2.6 to 31 pg L-1. Results were in agreement at a 95% confidence level (paired t-test) with those obtained for digested samples. Recoveries of Pb added to vinegars varied from 96 to 108% with and from 72 to 86% without an internal standard. Two water standard reference materials diluted in vinegar sample were also analyzed and results were in agreement with certified values at a 95% confidence level. The characteristic mass was 40 pg Pb and the useful lifetime of the tube was around 1600 firings. The limit of detection was 0.3 mu g L-1 and the relative standard deviation was <= 3.8% and <= 8.3% (n = 12) for a sample containing, 10 mu L-1 Pb with and without internal standard, respectively. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
We determined the effect of intracerebroventricular (icv) administration of losartan, an angiotensin II (ANG II) subtype 1 receptor (AT1) antagonist, on icv carbachol-induced natriuresis, kaliuresis and antidiuresis in water-loaded male Holtzman rats (250-300 g) with a cannula implanted into the lateral ventricle (LV). The rats were water loaded with 5% of their body weight by gavage twice, with the second gavage one hour after the first. Carbachol (2 nmol in 1 mu l) was injected icv immediately after the second load. When losartan (DUP-753, 50 nmol in 1 mu l) was administered icv, it was given 3 min before carbachol. Previous icv treatment with losartan significantly reduced the icv carbachol-induced natriuresis (324 +/- 17 mu Eq/120 min), kaliuresis (103 +/- 15 mu Eq/120 min) and antidiuresis (13.5 +/- 2.1 ml/120 min) compared to the effects of previous icv injection of saline (Nai excretion = 498 +/- 22 mu Eq/120 min; K+ excretion = 167 +/- 20 mu Eq/120 min; urine volume = 5.2 +/- 1.2 ml/120 min). These results, reported as means +/- SEM for 12 rats in each group, are consistent with the hypothesis that AT1 subtype receptors participate in the regulation of body electrolyte balance.
Resumo:
A flow injection system with online sample preparation is proposed for the determination of phosphite in liquid fertilizers by spectrophotometry. After loop-based injection, phosphite is oxidized by an acidic permanganate solution (1.0 10(-2) mol L-1 KMnO4 + 1.0 mol L-1 H2SO4) in a heated reactor (50 degreesC). The phosphate generated is then determined by the molybdenum blue method. Influence of flow rates, temperature, and concentration and order of addition of reagents, sample volume, and reactor configuration for the blue complex formation on recorded signals were investigated. The pow system was applied to phosphite determination in commercial samples of liquid fertilizers. The proposed system handles about 80 samples per hour [0.05-0.40% (w/v) H3PO3; R = 0,9998], consuming about 80 muL sample, 1 mg KMnO4, 25 mg (NH)(6)Mo7O24, and Ia mg ascorbic acid per determination. Results are precise [relative standard deviation less than or equal to 3.5% for 0.1% (w/v) H3PO3, n = 12] and in agreement with those obtained by gravimetry at 95% confidence level. (C) 2000 John Wiley & Sons, Inc.
Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode
Resumo:
The PB film-modified electrode was used as an amperometric detector for flow injection analysis of ascorbic acid. The modified electrode detector showed good sensitivity, stability and reproducibility. The calibration curve for ascorbic acid was linear over the concentration range from 5.0 x 10(-6) to 1.0 x 10(-3) mol l(-1) with a slope of 19.9 mA mol(-1) per litre and a correlation coefficient of 0.999. The detection limit of this method was 2.49 x 10(-6) mol l(-1). The relative standard deviation of six replicate injections of 2.5 x 10(-4) mol l(-1) ascorbic acid was 2.5%. The results obtained for ascorbic acid determination in pharmaceutical products are in good agreement with those obtained by using the procedure involving the reaction between triiodide and ascorbic acid. (C) 2001 Elsevier B.V. B.V. All rights reserved.