951 resultados para PET CATS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arbeit an der Bibliothek noch nicht eingelangt - Daten nicht geprüft

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objectives: Cerebrotendinous xanthomatosis (CTX) is a rare autosomal recessive lipid-storage disease caused by mutations in the CYP27A1. The purpose of this study is to determine the clinical characteristics, neuroimaging and mutation detect in a family with CTX systematically. Methods: Collecting history materials and detecting the routine clinical biochemical tests and imaging examination, and for the first time taking the whole body positron emission tomography (PET)-CT examination for probed in the world to research abnormal metabolism activities in CTX. To observe the effect of treatment with chenodeoxycholic acid (CDCA) and stains before and after the intervention, using serum lipid level detection and neuropsychological evaluation. Genetic testing was carried out to screen the nine exons and exon-intron boundaries about 200-300bq of CYP27A1. Results: A 37-year-old woman with typical clinical characteristics of CTX. Magnetic resonance imaging (MRI) of brain showed bilateral lesions in the dentate nucleus of the cerebellum, then, PET images revealed multiple abnormal hypermetabolism areas at distal tendon, and multifocal areas of hypometabolism in bilateral sides of cerebellar hemispheres, the frontal lobe and temporal lobe. Histopathology reveals accumulation of xanthoma cells and dispersed lipid crystal clefts in xanthomas. In genetic analysis, it shown an insertion of cytosine (77-78insC) located in the first exon of CYP27A1 in the proband. Conclusions: We found that a Chinese patient presented a typical clinical feature of CTX along with clear correlation on both structural and functional imaging had a novel mutation in the CYP27A1 gene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bogotá (Colombia): Universidad de La Salle. Facultad de Ingeniería. Programa de Ingeniería Civil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reaction of post-consumer poly(ethylene terephthalate) with aqueous solutions of sulfuric acid 7.5M was investigated in terms of temperature, time and particle size. The reaction extent reached 80% in four days at 100 degrees C and 90% in 5 hours at 135 degrees C. TPA obtained was purified and considered in the same level of quality of the commercial one after tests of elemental analysis, particle size and color. It was concluded that the hydrolysis occurred preferentially at the chain ends and superficially, having as controller mechanism the acid diffusion into the polymer structure. The shrinking-core model can explain the reaction kinetics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Instituto de Física, Programa de Pós-Graduação em Física, Mestrado Nacional Profissional em Ensino de Física, 2015.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Instituto de Física, Programa de Pós-Graduação em Física, Mestrado Nacional Profissional em Ensino de Física, 2015.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Instituto de Física, Programa de Pós-Graduação em Física, Mestrado Nacional Profissional em Ensino de Física, 2015.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A doença de Alzheimer (DA) têm-se constituído, nos últimos anos, num sério problema de saúde pública nas sociedades ocidentais, um reflexo de uma população cada vez mais envelhecida fruto da melhoria geral da assistência médica e das mudanças demográficas daí decorrentes. Tratando-se uma doença neurodegenerativa a DA conduz à perda de diversas faculdades cognitivas e carateriza-se pela redução progressiva de tamanho e número das células cerebrais, a par da formação de emaranhados neurofibrilares (NFTs) no seu interior e placas de β-amilóide (Aβ) no espaço exterior. Na última década, o diagnóstico da DA ganhou um importante aliado com a possibilidade de realização de Tomografia por Emissão de Positrões (PET) com o radiofármaco [11C]PiB que apresenta afinidade pelas placas de Aβ. Recentemente, foi também possível aumentar a confiança deste diagnóstico complementando-o com a avaliação do metabolismo cerebral da glicose através da sua conjugação, no mesmo protocolo PET com a [18F]FDG. No que concerne à realidade portuguesa, o ICNAS, uma unidade orgânica de investigação da Universidade de Coimbra focada na Utilização Biomédica das Ciências Nucleares, que inclui na sua estrutura uma unidade de produção radiofarmacêutica com ciclotrão, é um local privilegiado para a realização de PET cerebral com [11C]PiB. Desde Abril de 2012 até Julho de 2014 foram já realizados 107 estudos com [11C]PiB, dos quais 37 fizeram parte de estudos sequenciais onde o mesmo doente realizou o estudo combinado com [11C]PiB e [18F]FDG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quality of the image of 18F-FDG PET/CT scans in overweight patients is commonly degraded. This study evaluates, retrospectively, the relation between SNR, weight and dose injected in 65 patients, with a range of weights from 35 to 120 kg, with scans performed using the Biograph mCT using a standardized protocol in the Nuclear Medicine Department at Radboud University Medical Centre in Nijmegen, The Netherlands. Five ROI’s were made in the liver, assumed to be an organ of homogenous metabolism, at the same location, in five consecutive slices of the PET/CT scans to obtain the mean uptake (signal) values and its standard deviation (noise). The ratio of both gave us the Signal-to- Noise Ratio in the liver. With the help of a spreadsheet, weight, height, SNR and Body Mass Index were calculated and graphs were designed in order to obtain the relation between these factors. The graphs showed that SNR decreases as the body weight and/or BMI increased and also showed that, even though the dose injected increased, the SNR also decreased. This is due to the fact that heavier patients receive higher dose and, as reported, heavier patients have less SNR. These findings suggest that the quality of the images, measured by SNR, that were acquired in heavier patients are worst than thinner patients, even though higher FDG doses are given. With all this taken in consideration, it was necessary to make a new formula to calculate a new dose to give to patients and having a good and constant SNR in every patient. Through mathematic calculations, it was possible to reach to two new equations (power and exponential), which would lead to a SNR from a scan made with a specific reference weight (86 kg was the considered one) which was independent of body mass. The study implies that with these new formulas, patients heavier than the reference weight will receive higher doses and lighter patients will receive less doses. With the median being 86 kg, the new dose and new SNR was calculated and concluded that the quality of the image remains almost constant as the weight increases and the quantity of the necessary FDG remains almost the same, without increasing the costs for the total amount of FDG used in all these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Medicina Nuclear (MN) permite investigar o estado fisiológico dos tecidos de forma minimamente invasiva, usando radiofármacos (rf’s), moléculas compostas por um análogo biológico específico desses processos fisiológicos e um marcador radioativo (radionuclídeo). PET/CT (do acrónimo inglês Positron Emission Tomography/Computed Tomography), uma das modalidades de imagem em MN, está a expandir-se rapidamente em muitos Países. As imagens obtidas revelam a biodistribuição dos rf’s usados e permitem conhecer a sua distribuição precisa no organismo. 18F-Fluorodesoxiglicose (FDG), um análogo da glicose, é o rf mais comumente utilizado, isto porque em neoplasias as células são geralmente caracterizadas pelo aumento do metabolismo da glicose. A quantificação realizada em imagens de PET, tem por base uma estimativa quantitativa do metabolismo da glicose no tumor, utilizando o índice de captação estandardizado, SUV (do acrónimo inglês Standard Uptake Value). A realização de estudos dinâmicos em PET/CT, isto é, realizados em sequência temporal imediatamente após a administração endovenosa do rf e, durante um período de tempo pré-determinado (por exemplo, 15 minutos) permite que o registo da cinética inicial dos rf’s seja estudado. A análise dos dados obtidos com o estudo dinâmico permite compreender o grau e a perfusão tumoral. Habitualmente, quanto maior a captação de 18F-FDG num tumor, maior é a sua atividade metabólica glicolítica, o que tem sido traduzido em maior agressividade tumoral. Nesta investigação, realizaram-se estudos dinâmicos num grupo restrito de patologias oncológicas, nomeadamente: carcinoma da bexiga, carcinoma do colo do útero, carcinoma colorretal, carcinoma do endométrio, metástases hepáticas e adenocarcinoma pancreático. Realizaram-se estudos dinâmicos durante cerca de 10/15 minutos, com 1minuto por frame. O objetivo desta Investigação é tentar compreender se, tumores com maior perfusão respondem melhor à Radioterapia (RT), ou se, a resposta é independente da perfusão. Para avaliar os valores de SUV’s ao longo tempo, realizaram-se ROI’s (do acrónimo inglês Region of Interest), nas artérias femorais ou aorta e na lesão tumoral. Com estes dados, criaram-se gráficos de atividade/tempo onde, no eixo das abcissas é representado o tempo e no eixo das ordenadas os valores de SUV. A partir destes gráficos e dos dados neles contidos, calculou-se o Índice de Perfusão Tumoral através de 2 métodos: A, Método Trapezoidal de Aproximação que relaciona a razão entre a área perfusional do tumor e a área de fluxo arterial, até ao momento do cruzamento das curvas; B, mais simples, calculando o Índice de Perfusão do Tumor através da razão entre o valor de SUV máximo da curva tumoral e da curva arterial até ao momento do cruzamento das curvas. O Método de Comparação de Métodos de Altman&Bland, revelou que tanto o método A como o método B são semelhantes para o cálculo do Índice de Perfusão Tumoral. Em conclusão, apesar do número reduzido de indivíduos estudados, os dados apresentados indicam que existe uma tendência para que haja melhor resposta à RT por parte dos tumores com maior índice metabólico e maior índice de perfusão. Os tumores com menor índice metabólico e menor grau perfusional parece que respondem pior à RT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents the laboratory scale results of an extra step in Poly (ethylene terephthalate) - PET mechanical recycling (grinding, washing, drying and reprocessing): a chemical washing after the conventional one. Cooking oil PET bottle flakes were washed in water and then subjected to a reaction with an aqueous solution of sodium hydroxide 5 M at 90 degrees C for 10 min (chemical washing). After rinsing and drying, the flakes were characterized by thermogravimetry, gas chromatography and elemental analysis tests. The results indicated that the chemically washed material had higher purity than PET washed only with water: 99.3% and 96.7%, respectively, which undoubtedly implies properties, applications and prices closer to those of virgin resin. The production of purified terephthalic acid (TPA) from the chemical washing residue was optimized and reached a purity of 99.6%. Despite the results, the use of chemically washed PET and of TPA obtained is not recommended for direct contact with food, since they still contain some impurities. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Post-consumer cooking oil and soft drink PET bottles (PEToil and PETsoft drink) were ground and washed only with water (conventional washing). The polymer was then chemically washed (10min in an aqueous solution of sodium hydroxide 5mol center dot L-1 at 90 degrees C) and rinsed. The materials before and after chemical washing were characterized by intrinsic viscosity, differential scanning calorimetry, thermogravimetry, elemental analysis, scanning electron microscopy with X-ray spectrum microanalysis, and gas chromatography coupled to mass spectrometry. The results indicated that conventionally washed PEToil is the material that most differs among the four tested ones, and that the other three are more similar to each other and to what is expected for pure PET. For example, the composition of PEToil washed only in water contained 30 volatile organic compounds, 5 nonvolatile compounds, and 7 metals, while PETsoft drink washed conventionally and chemically contained 5 volatile organic compounds and no metal or nonvolatile organic compounds.