946 resultados para Mechanical response


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A victim of phishing emails could be subjected to money loss and identity theft. This paper investigates the different types of phishing email victims, with the goal of increasing such victims' defences. To obtain this kind of information, an experiment which involves sending a phishing email to participants is conducted. Quantitative and qualitative methods are also used to collect users' information. A model for detecting deception has been employed to understand victims' behaviour. This paper reports the qualitative results. The findings suggest that victims of phishing emails do not always exhibit the same vulnerability. The cause of being a victim is a result of three weaknesses in the detection process: (1) lack of knowledge; (2) weak confirmation channel, and; (3) victims' high propensity towards risk-taking. Therefore, it is suggested that users be provided with suitable confirmation channels and be more risk averse in their behaviour so that they would not fall victim to phishing emails.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to develop a demand-side-response model, which assists electricity consumers exposed to the market price to independently and proactively manage air-conditioning peak electricity demand. The main contribution of this research is to show how consumers can optimize the energy cost caused by the air conditioning load considering to several cases e.g. normal price, spike price, and the probability of a price spike case. This model also investigated how air-conditioning applies a pre-cooling method when there is a substantial risk of a price spike. The results indicate the potential of the scheme to achieve financial benefits for consumers and target the best economic performance for electrical generation distribution and transmission. The model was tested with Queensland electricity market data from the Australian Energy Market Operator and Brisbane temperature data from the Bureau of Statistics regarding hot days from 2011 to 2012.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In hyper competition, firms that are agile: sensing and responding better to customer requirements tend to be more successful and achieve supernormal profits. In spite of the widely accepted importance of customer agility, research is limited on this construct. The limited research also has predominantly focussed on the firm’s perspective of agility. However, we propose that the customers are better positioned to determine how well a firm is responding to their requirements (aka a firm’s customer agility). Taking the customers’ stand point, we address the issue of sense and respond alignment in two perspectives-matching and mediating. Based on data collected from customers in a field study, we tested hypothesis pertaining to the two methods of alignment using polynomial regression and response surface methodology. The results provide a good explanation for the role of both forms of alignment on customer satisfaction. Implication for research and practice are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assessed the revised Behavioural Inhibition System (BIS), as conceptualised by Gray and McNaughton’s (2000) revised RST, by exposing participants to a loss-framed road safety message (emphasising the negative consequences of speeding behaviour) and a high performance motor vehicle promotional advertisement. Licensed young drivers (N = 40, aged 17–25 years) were randomly allocated to view either the message or both the message and advertisement. Participants then completed a computerised lexical decision task prior to completing three personality measures: Corr-Cooper RST-PQ, CARROT and Q-Task. It was predicted that those with a stronger BIS would demonstrate greater processing of these mixed message cues compared to weaker BIS individuals, and that this BIS effect would only be observed in the mixed cues condition (due to simultaneous activation of the incentive and punishment systems). Preliminary findings will be discussed in the context of the influence of personality traits on health message processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The goal of this article is to examine whether or not the results of the Queensland Community Engagement Trial (QCET)-a randomized controlled trial that tested the impact of procedural justice policing on citizen attitudes toward police-were affected by different types of nonresponse bias. Method We use two methods (Cochrane and Elffers methods) to explore nonresponse bias: First, we assess the impact of the low response rate by examining the effects of nonresponse group differences between the experimental and control conditions and pooled variance under different scenarios. Second, we assess the degree to which item response rates are influenced by the control and experimental conditions. Results Our analysis of the QCET data suggests that our substantive findings are not influenced by the low response rate in the trial. The results are robust even under extreme conditions, and statistical significance of the results would only be compromised in cases where the pooled variance was much larger for the nonresponse group and the difference between experimental and control conditions was greatly diminished. We also find that there were no biases in the item response rates across the experimental and control conditions. Conclusion RCTs that involve field survey responses-like QCET-are potentially compromised by low response rates and how item response rates might be influenced by the control or experimental conditions. Our results show that the QCET results were not sensitive to the overall low response rate across the experimental and control conditions and the item response rates were not significantly different across the experimental and control groups. Overall, our analysis suggests that the results of QCET are robust and any biases in the survey responses do not significantly influence the main experimental findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To obtain accurate Monte Carlo simulations of small radiation fields, it is important model the initial source parameters (electron energy and spot size) accurately. However recent studies have shown that small field dosimetry correction factors are insensitive to these parameters. The aim of this work is to extend this concept to test if these parameters affect dose perturbations in general, which is important for detector design and calculating perturbation correction factors. The EGSnrc C++ user code cavity was used for all simulations. Varying amounts of air between 0 and 2 mm were deliberately introduced upstream to a diode and the dose perturbation caused by the air was quantified. These simulations were then repeated using a range of initial electron energies (5.5 to 7.0 MeV) and electron spot sizes (0.7 to 2.2 FWHM). The resultant dose perturbations were large. For example 2 mm of air caused a dose reduction of up to 31% when simulated with a 6 mm field size. However these values did not vary by more than 2 % when simulated across the full range of source parameters tested. If a detector is modified by the introduction of air, one can be confident that the response of the detector will be the same across all similar linear accelerators and the Monte Carlo modelling of each machine is not required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern cancer research requires physiological, three-dimensional (3-D) cell culture platforms, wherein the physical and chemical characteristics of the extracellular matrix (ECM) can be modified. In this study, gelatine methacrylamide (GelMA)-based hydrogels were characterized and established as in vitro and in vivo spheroid-based models for ovarian cancer, reflecting the advanced disease stage of patients, with accumulation of multicellular spheroids in the tumour fluid (ascites). Polymer concentration (2.5-7% w/v) strongly influenced hydrogel stiffness (0.5±0.2kPa to 9.0±1.8kPa) but had little effect on solute diffusion. The diffusion coefficient of 70kDa fluorescein isothiocyanate (FITC)-labelled dextran in 7% GelMA-based hydrogels was only 2.3 times slower compared to water. Hydrogels of medium concentration (5% w/v GelMA) and stiffness (3.4kPa) allowed spheroid formation and high proliferation and metabolic rates. The inhibition of matrix metalloproteinases and consequently ECM degradability reduced spheroid formation and proliferation rates. The incorporation of the ECM components laminin-411 and hyaluronic acid further stimulated spheroid growth within GelMA-based hydrogels. The feasibility of pre-cultured GelMA-based hydrogels as spheroid carriers within an ovarian cancer animal model was proven and led to tumour development and metastasis. These tumours were sensitive to treatment with the anti-cancer drug paclitaxel, but not the integrin antagonist ATN-161. While paclitaxel and its combination with ATN-161 resulted in a treatment response of 33-37.8%, ATN-161 alone had no effect on tumour growth and peritoneal spread. The semi-synthetic biomaterial GelMA combines relevant natural cues with tunable properties, providing an alternative, bioengineered 3-D cancer cell culture in in vitro and in vivo model systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While both the restoration of the blood supply and an appropriate local mechanical environment are critical for uneventful bone healing, their influence on each other remains unclear. Human bone fracture haematomas (<72h post-trauma) were cultivated for 3 days in fibrin matrices, with or without cyclic compression. Conditioned medium from these cultures enhanced the formation of vessel-like networks by HMEC-1 cells, and mechanical loading further elevated it, without affecting the cells’ metabolic activity. While haematomas released the angiogenesis-regulators, VEGF and TGF-β1, their concentrations were not affected by mechanical loading. However, direct cyclic stretching of the HMEC-1 cells decreased network formation. The appearance of the networks and a trend towards elevated VEGF under strain suggested physical disruption rather than biochemical modulation as the responsible mechanism. Thus, early fracture haematomas and their mechanical loading increase the paracrine stimulation of endothelial organisation in vitro, but direct periodic strains may disrupt or impair vessel assembly in otherwise favourable conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The learning and teaching of epidemiology is core to many public health programs. Many students find the content of epidemiology, and specifically risk of bias assessment, challenging to learn. Howbeit, learning is enhanced when knowledge is able to be acquired from an active-learning, hands-on experience. Methods The innovative use of wireless audience response technology “clickers” was incorporated into the lectures of the university’s post-graduate epidemiology units and the tailored epidemiological modules delivered for professional disciplines (e.g. optometry). Clickers were used to apply several pedagogical approaches of active learning including peer-instruction and real-world simulation. Students were also assessed for their gain in knowledge within the lecture (pre-post) and their perceptions of how the use of clickers helped them learn. The routine university-wide end of semester Insight Survey provided further information of the student’s satisfaction with the approach. Results The technology was useful in identifying deficits of knowledge of key concepts either before or after instruction. Where key concepts were re-tested post-lecture, as expected, knowledge increased significantly and provided immediate feed-back to students. Across the lecture series, typically 85% of students identified the technology helped them learn, increased their opportunity to interact with the lecturer, and recommend their use for future classes. The Insight Survey report identified 93% of respondents identified the unit in which clickers were consistently used provided good learning opportunities. Numerous student comments supported the teaching method. Conclusions Epidemiological subject matter lends itself to incorporation of audience response technology. The use of the technology to facilitate interactive voting provides an instant response and participation of everyone to enhance the classroom experience. The pedagogical approach increases students’ knowledge and increases their satisfaction with the unit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone is characterized with an optimized combination of high stiffness and toughness. The understanding of bone nanomechanics is critical to the development of new artificial biological materials with unique properties. In this work, the mechanical characteristics of the interfaces between osteopontin (OPN, a noncollagenous protein in extrafibrillar protein matrix) and hydroxyapatite (HA, a mineral nanoplatelet in mineralized collagen fibrils) were investigated using molecular dynamics method. We found that the interfacial mechanical behaviour is governed by the electrostatic attraction between acidic amino acid residues in OPN and calcium in HA. Higher energy dissipation is associated with the OPN peptides with a higher number of acidic amino acid residues. When loading in the interface direction, new bonds between some acidic residues and HA surface are formed, resulting in a stick-slip type motion of OPN peptide on the HA surface and high interfacial energy dissipation. The formation of new bonds during loading is considered to be a key mechanism responsible for high fracture resistance observed in bone and other biological materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different amounts of Ru were implanted into thermally evaporated WO3 thin films by ion implantation. The films were subsequently annealed at 600oC for 2 hours in air to remove defects generated during the ion implantation. The Ru concentrations of four samples have been quantified by Rutherford Backscattering Spectrometry as 0.8, 5.5, 9 and 11.5 at%. The un-implanted WO3 films were highly porous but the porosity decreased significantly after ion implantation as observed by Transmission Electron Microscopy and Scanning Electron Microscopy. The thickness of the films also decreased with increasing Ru-ion dose, which is mainly due to densification of the porous films during ion implantation. From Raman spectroscopy two peaks at 408 and 451 cm-1 (in addition to the typical vibrational peaks of the monoclinic WO3 phase) associated with Ru were observed. Their intensity increased with increasing Ru concentration. X-Ray Photoelectron Spectroscopy showed a metallic state of Ru with binding energy of Ru 3d5/2 at 280.1 eV. This peak position remained almost unchanged with increasing Ru concentration. The resistances of the Ru-implanted films were found to increase in the presence of NO2 and NO with higher sensor response to NO2. The effect of Ru concentration on the sensing performance of the films was not explicitly observed due to reduced film thickness and porosity with increasing Ru concentration. However, the results indicate that the implantation of Ru into WO3 films with sufficient film porosity and film thickness can be beneficial for NO2 sensing at temperatures in the range of 250°C to 350°C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the blast response, damage mechanism and evaluation of residual load capacity of a concrete–steel composite (CSC) column using dynamic computer simulation techniques. This study is an integral part of a comprehensive research program which investigated the vulnerability of structural framing systems to catastrophic and progressive collapse under blast loading and is intended to provide design information on blast mitigation and safety evaluation of load bearing vulnerable columns that are key elements in a building. The performance of the CSC column is compared with that of a reinforced concrete (RC) column with the same dimensions and steel ratio. Results demonstrate the superior performance of the CSC column, compared to the RC column in terms of residual load carrying capacity, and its potential for use as a key element in structural systems. The procedure and results presented herein can be used in the design and safety evaluation of key elements of multi-storey buildings for mitigating the impact of blast loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gold particle interaction with few-layer graphenes is of interest for the development of numerous optical nanodevices. The results of numerical studies of the coupling of gold nanoparticles with few-layer vertical graphene sheets are presented. The field strengths are computed and the optimum nanoparticle configurations for the formation of SERS hotpots are obtained. The nanoparticles are modeled as 8 nm diameter spheres atop 1.5 nm (5 layers) graphene sheet. The vertical orientation is of particular interest as it is possible to use both sides of the graphene structure and potentially double the number of particles in the system. Our results show that with the addition of an opposing particle a much stronger signal can be obtained as well as the particle separation can be controlled by the number of atomic carbon layers. These results provide further insights and contribute to the development of next-generation plasmonic devices based on nanostructures with hybrid dimensionality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lower extremities are particularly susceptible to injury in an under‐vehicle explosion. Operational fitness of military vehicles is assessed through anthropometric test devices (ATDs) in full‐scale blast tests. The aim of this study was to compare the response between the Hybrid‐III ATD, the MiL‐Lx ATD and cadavers in our traumatic injury simulator, which is able to replicate the response of the vehicle floor in an under‐vehicle explosion. All specimens were fitted with a combat boot and tested on our traumatic injury simulator in a seated position. The load recorded in the ATDs was above the tolerance levels recommended by NATO in all tests; no injuries were observed in any of the 3 cadaveric specimens. The Hybrid‐III produced higher peak forces than the MiL‐Lx. The time to peak strain in the calcaneus of the cadavers was similar to the time to peak force in the ATDs. Maximum compression of the sole of the combat boot was similar for cadavers and MiL‐Lx, but significantly greater for the Hybrid‐III. These results suggest that the MiL‐Lx has a more biofidelic response to under‐vehicle explosive events compared to the Hybrid‐III. Therefore, it is recommended that mitigation strategies are assessed using the MiL‐Lx surrogate and not the Hybrid‐III.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of dual growing rods is a fusionless surgical approach to the treatment of early onset scoliosis (EOS) which aims to harness potential growth in order to correct spinal deformity. This study compared through in-vitro experiments the biomechanical response of two different rod designs under axial rotation loading. The study showed that a new design of telescoping growing rod preserved the rotational flexibility of the spine in comparison with rigid rods indicating them to be a more physiological way to improve the spinal deformity.