Gas sensing of ruthenium implanted tungsten oxide thin films
Data(s) |
11/03/2014
|
---|---|
Resumo |
Different amounts of Ru were implanted into thermally evaporated WO3 thin films by ion implantation. The films were subsequently annealed at 600oC for 2 hours in air to remove defects generated during the ion implantation. The Ru concentrations of four samples have been quantified by Rutherford Backscattering Spectrometry as 0.8, 5.5, 9 and 11.5 at%. The un-implanted WO3 films were highly porous but the porosity decreased significantly after ion implantation as observed by Transmission Electron Microscopy and Scanning Electron Microscopy. The thickness of the films also decreased with increasing Ru-ion dose, which is mainly due to densification of the porous films during ion implantation. From Raman spectroscopy two peaks at 408 and 451 cm-1 (in addition to the typical vibrational peaks of the monoclinic WO3 phase) associated with Ru were observed. Their intensity increased with increasing Ru concentration. X-Ray Photoelectron Spectroscopy showed a metallic state of Ru with binding energy of Ru 3d5/2 at 280.1 eV. This peak position remained almost unchanged with increasing Ru concentration. The resistances of the Ru-implanted films were found to increase in the presence of NO2 and NO with higher sensor response to NO2. The effect of Ru concentration on the sensing performance of the films was not explicitly observed due to reduced film thickness and porosity with increasing Ru concentration. However, the results indicate that the implantation of Ru into WO3 films with sufficient film porosity and film thickness can be beneficial for NO2 sensing at temperatures in the range of 250°C to 350°C. |
Formato |
application/pdf |
Identificador | |
Publicador |
Elsevier |
Relação |
http://eprints.qut.edu.au/69947/2/69947.pdf http://www.sciencedirect.com/science/article/pii/S0040609014002399# DOI:10.1016/j.tsf.2014.02.084 Tesfamichael, T., Ahsan, M., Notarianni, M., Groß, A., Hagen, G., Moos, R., Ionescu, M., & Bell, J. (2014) Gas sensing of ruthenium implanted tungsten oxide thin films. Thin Solid Films, 558, pp. 416-422. |
Direitos |
Copyright 2014 2014 Elsevier B.V. All rights reserved. This is the author’s version of a work that was accepted for publication in Thin Solid Films. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in Thin Solid Films, [in press] DOI: 10.1016/j.tsf.2014.02.084 |
Fonte |
School of Chemistry, Physics & Mechanical Engineering; Institute for Future Environments; Science & Engineering Faculty |
Palavras-Chave | #Nanostructured tungsten oxide #Thin films #Ru-ion implantation #Sensor response #NO2 gas sensors |
Tipo |
Journal Article |