999 resultados para Ingeniero de caminos, canales y puertos
Resumo:
El propósito del proyecto es la construcción de un puente que se situará cercano a la población de Valdenoceda,a la altura del kilómetro 532 de la N-232, cruzando dicha carretera el río Ebro. Los principales objetivos a alcanzar son los mencionados a continuación: mejorar la conectividad entre las poblaciones situadas a ambas márgenes del rio Ebro, perfeccionar el trazado de la carretera N-232, evitar la travesía de la carretera N-232, atravesando las poblaciones situadas entre los puntos kilométricos 531 y 535 de la carretera N-232, aumentando su seguridad y bienestar y, finalmente, mejorar la seguridad para el tráfico de la carretera N-232 y su conexión con la CL-629.
Resumo:
This cooperation project aims to improve the sanitation facilities of the city of Wukro (located in the Tigray Region, northern Ethiopia), particularly the management of latrine wastes, by designing a sludge treatment plant in the city. It is framed within the Final Project Department of the E.T.S.I. de Caminos, Canales y Puertos, in collaboration with Wukro’s St. Mary’s College and the Mission of Ángel Olaran, that are part of the Ethiopian Catholic Church Diocese of Adigrat (ECCA). The present city, of about 42,000 inhabitants, was founded by the Italians in 1936. Due to its geographic location, which makes the city suitable for industrial and agricultural activities, Wukro is becoming an important administrative and economic center in the region, with a fast growing population.
Resumo:
Este proyecto es el primer trabajo que se realiza con objeto de construir una presa en el cauce del arroyo de la Jornia, que discurre por la provincia de Toledo. Además de la misión fundamental de la presa, que es el abastecimiento para el riego de fincas próximas, se pueden añadir otra serie de objetivos que surgen de dicho proyecto: permitir el crecimiento urbanístico de la zona al acabar con la continua carencia de agua, lo que paliaría la tendencia demográfica descendente de esos municipios; mantener y potenciar el aprovechamiento de la calidad medioambiental de la zona, motivo por el que en el proyecto se cuidarán mucho todos los detalles relacionados con este aspecto; promover el empleo en la zona y el desarrollo de industrias que trabajarán en las obras emprendidas; fomentar el crecimiento poblacional y turístico de la zona, mediante el desarrollo de actividades acuáticas deportivas en el embalse creado por la presa.
Resumo:
Implantación de la Red de Alta velocidad Ferroviaria en California. Tramo San Francisco-Sacramento. Este artículo de la serie “Alta velocidad Ferroviaria en California (CHSRS), se ocupa de la línea San Francisco– Sacramento “Bay Crossing Alternative”, que cierra la red de alta velocidad ferroviaria del Estado de California, permitiendo en la terminal HSR de Sacramento, conectar con la línea Fresno–Sacramento, en coincidencia de trazados para en el futuro prolongar la red californiana de alta velocidad ferroviaria hasta su entronque con la del Estado de Nevada, vía Tahoe Lake–Reno. La línea San Francisco–Sacramento “Bay Crossing Alternative”, consta de tres trayectos: El primero de ellos “San Francisco urbano” va desde la terminal HSR “San Francisco Airport”, donde termina la alternativa “Golden Gate” de la línea Fresno–San Francisco, hasta el viaducto de acceso al Paso de la Bahía, que constituye el segundo trayecto “San Francisco–Richmond”, trayecto estrella de la red, de 15,48 Km de longitud sobre la Bahía de San Francisco, con desarrollo a través de 11,28 Km en puente colgante múltiple, con vanos de 800 m de luz y 67 m de altura libre bajo el tablero que permite la navegación en la Bahía. El tercer trayecto “Richmond–Sacramento” cruza la Bahía de San Pablo con un puente colgante de 1,6 Km de longitud y tipología similar a los múltiples de la Bahía de San Francisco, pasa por Vallejo (la por plazo breve de tiempo, antigua capital del Estado de California) y por la universitaria Davis, antes de finalmente llegar a la HSR Terminal Station de Sacramento Roseville. This article of the series “California High Speed Railway System”(CHSRS) treats on Line San Francisco–Sacramento “Bay Crossing Alternative” (BCA). This line closes the system of California high speed state railway, and connects with the line Fresno–Sacramento “Stockton Arch Alternative”, joining its alignments in the HSR Terminal of Sacramento Roseville. From this station it will be possible, in the future, to extend the Californian railway system till the Nevada railway system, vía Tahoe Lake and Reno. The BCA consists of three sections: The first one passing through San Francisco city, goes from HSR San Francisco Airport Terminal Station (where the line Fresno–San Francisco “Golden Gate Alternative” ends), up to the Viaduct access at the Bay Crossing. The second section San Francisco–Richmond, constitutes the star section of the system, with 15,48 Km length on the San Francisco Bay, where 11,28 Km in multi suspension bridge, 800 m span and 67 m gauge under panel, to allow navigation through the Bay. The third section Richmond–Sacramento crosses the San Pablo Bay through another suspension bridge of similar typology to that of San Francisco Bay crossing; pass through Vallejo (the ancient and for a short time Head of the State of California) and through Davis, university city, to arrive to the HSR Terminal Station of Sacramento Roseville.
Resumo:
Implantación de la Red de Alta velocidad Ferroviaria en California. Tramo Fresno-Sacramento. El presente articúlo es la cuarta parte de la serie "Alta Velocidad Ferroviaria en California (CHSRS)". Recoge la Alternativa "Stockton Arch", que el Proyecto FARWEST presenta a la prevista por la Authority (CHSRA), para la Línea HSR Fresno-Sacramento, en programación y en trazado. Éste discurre, desde la gran Terminal de Fresno (implantada en las afueras al suroeste de la ciudad) por el segmento sur del "mar interior" (que en el Terciario Superior ocupaba el actual Valle Central), hasta Stockton, y por el segmento norte, hasta Sacramento. El Paet de Ripperdan (~ pK 40) queda conectado por carretera con el PAET de Oroloma de la Línea HSR Fresno-San Francisco (Golden Gate Alternative). La última parte del trazado de la Línea HSR Fresno-Sacramento (Stockton Arch Alternative), coincide en alineación y rasante con la Línea HSR San Francisco-Sacramento (Crossing Bay Alternative) a la altura de Roseville, donde se emplaza la gran terminal norte de la red de California, desde la que se unirá ésta con la de Nevada, por Reno. This article forras the fourth part of the series entitled "High Speed Railway in California (CHSRS)". It addresses the "Stockton Arch" alternative, which the FARWESTProjectpresents in scheduling and in alignment as to that provided for by the Authority (CHSRA) for the Fresno-Sacramento HSR Line. The latter runs from the grand Fresno Terminal (located in the outskirts to the southwest ofthe city) through the south segment ofthe "inland sea" (which oceupied the current Central Valley in the Upper Tertiary) to Stockton and through the north segment to Sacramento. The Ripperdan TSAP (post ofpassing and stabling trains), — kilometer point 40, conneets with the Oroloma TSAP ofthe Fresno-San Francisco HSR Line (Golden Gate Alternative) by road. The last part of the Fresno-Sacramento HSR Line alignment (Stockton Arch Alternative), coincides in alignment and grade with the San Francisco-Sacramento HSR Line (Crossing Bay Alternative) at Roseville, where the great north terminal ofthe California network is located, from which the latter will be linked with Nevada s network through Reno.
Resumo:
Implantación de la Red de Alta velocidad Ferroviaria en California. Tramo Fresno-Los Angeles-San Diego. Este artículo, tercera parte de la serie que describe la red de Alta Velocidad Ferroviaria de California (CHSRS), se ocupa de la línea Fresno-Los Angeles Airport-San Diego Airport, con el trazado propuesto en la Alternativa Missions Trail del Proyecto FARWEST, caracterizada por el paso directo de las montañas de Tehachapi, mediante dos grandes túneles de 27,5 Km (17 mile) y 25,6 Km (15,9 mile) de longitud. También por el emplazamiento de la estación terminal de Los Angeles, junto al Aeropuerto Internacional de Los Angeles y la sustitución de la circunvalación ferroviaria de la aglomeración urbana de Los Angeles, a través de Inland Empire, por el ramal Anaheim-Riverside, que da acceso a esa región, y que es cabecera de la futura Dessert Express a Las Vegas. The third of a series describing the California High Speed Railway (CHSRS), this article refers to the Fresno-Los Angeles Airport-San Diego Airport line, with the alignment as proposed in the Missions Trail Alternative of the FARWEST Project, characterized by the direct Tehachapi mountain pass through two large tunnels 27.5 Km (17 miles) and 25.6 Km (15.9 miles) long and also to the siting of the Los Angeles terminal station next to the Los Angeles International Airport and the replacement of the Los Angeles urban conglomeration railway by-pass through Inland Empire, by the Anaheim-Riverside branch providing access to that region and which is the head of the future Desert Express to Las Vegas.
Resumo:
Sistemas de Pesaje dinámico y estático en la Red de carreteras del Estado Español. Métodos de sanción. El artículo trata de los Proyectos de estaciones de pesaje en la red de carreteras estatales utilizadas para control de la carga de los vehículos pesados como resultado de la implantación del "Programa de Estaciones de Pesaje dinámico" elaborado por la Dirección General de Carreteras con la colaboración de la Dirección General de Transportes Terrestres. Dicho programa tiene entre sus objetivos preservar el patrimonio viario, regular el sector del transporte, aumentar la seguridad vial y verificar el cumplimiento del Reglamento General de Vehículos. Para ello ha previsto la instalación de 70 estaciones en todo el ámbito de la red estatal. El objeto de cada uno de los Proyectos de Construcción es el diseño de una estación de Pesaje en el margen de la autovía o carretera convencional para control de peso de los vehículos pesados, con la posibilidad de sancionar a los que sobrepasen el límite de masa indicado en el anexo IX del Reglamento General de Vehículos, con la consiguiente inmovilización temporal hasta que las condiciones del transporte sean las adecuadas. Cada estación consta de dos sistemas de pesaje que pueden funcionar de manera independiente: un sistema de pesaje, dinámico de alta velocidad en la calzada de la carretera y un sistema de pesaje estático o de baja velocidad que se encuentra en el interior de la estación. La explotación de estas estaciones está prevista mediante un control coordinado entre la Agrupación de Tráfico de la Guardia Civil y los Inspectores de Transportes del Estado y de las Comunidades Autónomas, con la colaboración de la Dirección General de Carreteras
Resumo:
El presente Proyecto comprende la definición, justificación y valoración de las obras necesarias para la ejecución de la red de saneamiento de aguas pluviales y residuales: excavación de zanjas; extendido de camas de asiento granular; colocación de tuberías y galerías prefabricadas de hormigón y PVC; ejecución de absorbederos y acometidas; ejecución de pozos y cámaras de registro; relleno compactado de zanjas; pruebas y limpieza de la red.
Resumo:
El objetivo del Proyecto es que el principal núcleo administrativo y el más importante núcleo turístico de la isla se conecten mediante una línea de altas prestaciones, que permita el tráfico mixto (viajeros y mercancías). Un corredor que ya fue contemplado en el Plan Territorial Especial, dentro del Plan Insular de Ordenación de Gran Canaria. Este corredor ferroviario permitirá reducir el actual tiempo de viaje entre ambos núcleos y disminuir la densidad de tráfico de la autopista GC-1, que destaca en la actualidad por su alto nivel de congestión.
Resumo:
Descripción de los principales grupos rupestres de habitación de La Rioja y su devenir.
Resumo:
Descripción de ciertos rasgos geológicos que amenazan el patrimonio religioso rupestre español. Rock sanctuaries are a historical heritage not as well-known as other religious constructions, due to their usual recondite location and abandoned condition. Spain has a large number of examples, mostly excavated during the Early Middle Age or even before. Fortunately, some of them are used on present worship, but the majority of these ancient shrines have suffered of severe damage through time, mostly due to common geological patterns. Some others threaten to collapse soon unless urgent remedial improvement is applied. Some examples at different locations are shown, reviewing their problems, which involve weathering, major rock cracks, soft rock pillars and others related to the defective site where they were located.
Resumo:
Light rail systems have proliferated in Spain in the last decade, following a tendency that is common not only in other European countries but also in other parts of the world. This paper reviews the benefits of light rail systems, both related to environmental issues and mobility issues. It analyses the evolution of light rail projects in Spain and shows that light rail systems in this country have evolved towards an extensive use of public-private partnerships. The analysis of the Spanish projects, however, does not contribute any conclusive evidence about whether public-private partnerships have been more efficient than publicly owned enterprises in building and operating light rail systems.
Resumo:
El presente trabajo trata de elementos reforzados con barras de armadura y Fibras Metálicas Recicladas (FMR). El objetivo principal es mejorar el comportamiento a fisuración de elementos sometidos a flexión pura y a flexión compuesta, aumentando en consecuencia las prestaciones en servicio de aquellas estructuras con requerimientos estrictos con respecto al control de fisuración. Entre éstas últimas se encuentran las estructuras integrales, es decir aquellas estructuras sin juntas (puentes o edificios), sometidas a cargas gravitatorias y deformaciones impuestas en los elementos horizontales debidas a retracción, fluencia y temperatura. Las FMR son obtenidas a partir de los neumáticos fuera de uso, y puesto que el procedimiento de reciclado se centra en el caucho en vez que en el acero, su forma es aleatoria y con longitud variable. A pesar de que la eficacia del fibrorefuerzo mediante FMR ha sido demostrada en investigaciones anteriores, la innovación que representa este trabajo consiste en proponer la acción combinada de barras convencionales y FMR en la mejora del comportamiento a fisuración. El objetivo es por tanto mejorar la sostenibilidad del proyecto de la estructura en HA al utilizar materiales reciclados por un lado, y aumentando por el otro la durabilidad. En primer lugar, se presenta el estado del arte con respecto a la fisuración en elementos de HA, que sucesivamente se amplía a elementos reforzados con barras y fibras. Asimismo, se resume el método simplificado para el análisis de columnas de estructuras sin juntas ya propuesto por Pérez et al., con particular énfasis en aquellos aspectos que son incompatibles con la acción de las fibras a nivel seccional. A continuación, se presenta un modelo para describir la deformabilidad seccional y la fisuración en elementos en HA, que luego se amplía a aquellos elementos reforzados con barras y fibras, teniendo en cuenta también los efectos debidos a la retracción (tension stiffening negativo). El modelo es luego empleado para ampliar el método simplificado para el análisis de columnas. La aportación consiste por tanto en contar con una metodología amplia de análisis para este tipo de elementos. Seguidamente, se presenta la campaña experimental preliminar que ha involucrado vigas a escala reducida sometidas a flexión simple, con el objetivo de validar la eficiencia y la usabilidad en el hormigón de las FMR de dos diferentes tipos, y su comportamiento con respecto a fibras de acero comerciales. Se describe a continuación la campaña principal, consistente en ensayos sobre ocho vigas en flexión simple a escala 1:1 (variando contenido en FRM, Ø/s,eff y recubrimiento) y doce columnas a flexión compuesta (variando contenido en FMR, Ø/s,eff y nivel de fuerza axil). Los resultados obtenidos en la campaña principal son presentados y comentados, resaltando las mejoras obtenidas en el comportamiento a fisuración de las vigas y columnas, y la rigidez estructural de las columnas. Estos resultados se comparan con las predicciones del modelo propuesto. Los principales parámetros estudiados para describir la fisuración y el comportamiento seccional de las vigas son: la separación entre fisuras, el alargamiento medio de las armaduras y la abertura de fisura, mientras que en los ensayos de las columnas se ha contrastado las leyes momento/curvatura, la tensión en las barras de armadura y la abertura de fisura en el empotramiento en la base. La comparación muestra un buen acuerdo entre las predicciones y los resultados experimentales. Asimismo, se nota la mejora en el comportamiento a fisuración debido a la incorporación de FMR en aquellos elementos con cuantías de armadura bajas en flexión simple, en elementos con axiles bajos y para el control de la fisuración en elementos con grandes recubrimientos, siendo por tanto resultados de inmediato impacto en la práctica ingenieril (diseño de losas, tanques, estructuras integrales, etc.). VIIIComo punto final, se presentan aplicaciones de las FMR en estructuras reales. Se discuten dos casos de elementos sometidos a flexión pura, en particular una viga simplemente apoyada y un tanque para el tratamiento de agua. En ambos casos la adicción de FMR al hormigón lleva a mejoras en el comportamiento a fisuración. Luego, utilizando el método simplificado para el análisis en servicio de columnas de estructuras sin juntas, se calcula la máxima longitud admisible en casos típicos de puentes y edificación. En particular, se demuestra que las limitaciones de la práctica ingenieril actual (sobre todo en edificación) pueden ser aumentadas considerando el comportamiento real de las columnas en HA. Finalmente, los mismos casos son modificados para considerar el uso de MFR, y se presentan las mejoras tanto en la máxima longitud admisible como en la abertura de fisura para una longitud y deformación impuesta. This work deals with elements reinforced with both rebars and Recycled Steel Fibres (RSFs). Its main objective is to improve cracking behaviour of elements subjected to pure bending and bending and axial force, resulting in better serviceability conditions for these structures demanding keen crack width control. Among these structures a particularly interesting type are the so-called integral structures, i.e. long jointless structures (bridges and buildings) subjected to gravitational loads and imposed deformations due to shrinkage, creep and temperature. RSFs are obtained from End of Life Tyres, and due to the recycling process that is focused on the rubber rather than on the steel they come out crooked and with variable length. Although the effectiveness of RSFs had already been proven by previous research, the innovation of this work consists in the proposing the combined action of conventional rebars and RSFs to improve cracking behaviour. Therefore, the objective is to improve the sustainability of RC structures by, on the one hand, using recycled materials, and on the other improving their durability. A state of the art on cracking in RC elements is firstly drawn. It is then expanded to elements reinforced with both rebars and fibres (R/FRC elements). Finally, the simplified method for analysis of columns of long jointless structures already proposed by Pérez et al. is resumed, with a special focus on the points that conflict when taking into account the action of fibres. Afterwards, a model to describe sectional deformability and cracking of R/FRC elements is presented, taking also into account the effect of shrinkage (negative tension stiffening). The model is then used to implement the simplified method for columns. The novelty represented by this is that a comprehensive methodology to analyse this type of elements is presented. A preliminary experimental campaign consisting in small beams subjected to pure bending is described, with the objective of validating the effectiveness and usability in concrete of RSFs of two different types, and their behaviour when compared with commercial steel fibres. With the results and lessons learnt from this campaign in mind, the main experimental campaign is then described, consisting in cracking tests of eight unscaled beams in pure bending (varying RSF content, Ø/s,eff and concrete cover) and twelve columns subjected to imposed displacement and axial force (varying RSF content, Ø/s,eff and squashing load ratio). The results obtained from the main campaign are presented and discussed, with particular focus on the improvement in cracking behaviour for the beams and columns, and structural stiffness for the columns. They are then compared with the proposed model. The main parameters studied to describe cracking and sectional behaviours of the beam tests are crack spacing, mean steel strain and crack width, while for the column tests these were moment/curvature, stress in rebars and crack with at column embedment. The comparison showed satisfactory agreement between experimental results and model predictions. Moreover, it is pointed out the improvement in cracking behaviour due to the addition of RSF for elements with low reinforcement ratios, elements with low squashing load ratios and for crack width control of elements with large concrete covers, thus representing results with a immediate impact in engineering practice (slab design, tanks, integral structures, etc.). Applications of RSF to actual structures are finally presented. Two cases of elements in pure bending are presented, namely a simple supported beam and a water treatment tank. In both cases the addition of RSF to concrete leads to improvements in cracking behaviour. Then, using the simplified model for the serviceability analysis of columns of jointless structures, the maximum achievable jointless length of typical cases of a bridge and building is obtained. In XIIparticular, it is shown how the limitations of current engineering practice (this is especially the case of buildings) can be increased by considering the actual behaviour of RC supports. Then, the same cases are modified considering the use of RSF, and the improvements both in maximum achievable length and in crack width for a given length and imposed strain at the deck/first floor are shown.
Resumo:
El principal objetivo del proyecto es que el tramo Teruel – Sagunto se conecte mediante una línea de altas prestaciones, con las características de una línea de Alta Velocidad, que permita el tráfico mixto (viajeros y mercancías). Un corredor que se encuentra entre las opciones estratégicas del PEIT para su inclusión en la Red Ferroviaria de Altas Prestaciones de ejes de primer nivel de carácter transversal, al objeto de modificar la geometría radial de la red existente. En todo caso, permitirá reducir el actual tiempo de viaje entre Teruel y Valencia en menos de 50 minutos, aproximadamente, y en menos de dos horas con Zaragoza. Asimismo, acortará la actual distancia por ferrocarril, de Teruel a Sagunto, entre 21 y 25 Km.
Resumo:
El subtramo en proyecto, es un tramo del corredor Cantábrico – Mediterráneo, propuesto en el Plan Estratégico de Infraestructuras del Transporte (PEIT), 2005-2020. El objetivo de este plan es disminuir el actual tiempo de viaje entre Teruel y Valencia a menos de 50 minutos, aproximadamente, y a menos de dos horas con Zaragoza. Asimismo, se reducirá la actual distancia por ferrocarril entre Teruel y Sagunto entre 21 y 25 kilómetros. Actualmente entre Teruel y Sagunto existe una línea ferroviaria sin electrificar, de vía única con longitud de 137 kilómetros. El trazado es muy sinuoso con radios de curva de hasta 550 metros, lo que limita la velocidad comercial del tramo.