980 resultados para Immunoassay, Assay validation, Accuracy, recision, Hyperinsulinemia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Experiences in Close Relationships Inventory permits to evaluate attachment in close relationships during adulthood based on two dimensions able to be present in this kind of relationships: the avoidance of proximity and the anxiety related with to abandonment. It is a self-report 7- points likert scale composed by 36 items. The Portuguese version was administered to a sample of 551 university students (60% female), the majority with ages between 19 and 24 years old (88%) in a dating relationship (86%). The principal components analysis with oblimin rotation was performed. The total scale has good internal consistency (α=.86), as also has the 2 sub-scales: anxiety (α=.86) and avoidance (α=.88). The two dimensions evaluated are significantly correlated with socio-demographics, relational characteristics (jealousy, relationship distress, and compromise), wishes (enmeshment versus differentiation) and fears (abandonment versus control) related to attitudes in significant relationships, which testify the construct validity of the instrument. The results obtained are coherent with the original version and other ECR‘s adaptations. Practitioners and researchers in the context of clinical psychology and related areas have now at their disposal the Portuguese version of the ECR inventory, which has shown its very high usefulness in the study of close relationships, and specifically attachment in adulthood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a model predictive current control applied to a proposed single-phase five-level active rectifier (FLAR). This current control strategy uses the discrete-time nature of the active rectifier to define its state in each sampling interval. Although the switching frequency is not constant, this current control strategy allows to follow the reference with low total harmonic distortion (THDF). The implementation of the active rectifier that was used to obtain the experimental results is described in detail along the paper, presenting the circuit topology, the principle of operation, the power theory, and the current control strategy. The experimental results confirm the robustness and good performance (with low current THDF and controlled output voltage) of the proposed single-phase FLAR operating with model predictive current control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En la investigación anterior -en la zona pampeana de la Provincia de Córdoba- se demostró teórica y empíricamente, que el desarrollo de la Sociedad Civil muchas veces libradas a su suerte y con limitaciones legales apoyan decididamente el desarrollo local, sin embargo han logrado solo parcialmente sus objetivos, por lo que es necesario comenzar un camino de fortalecimiento en los nuevos roles que deben asumir. Los gobiernos locales, a la vez, intentan trabajosamente con contados éxitos detener el procesos de descapitalización social -financiera y humana- de sus comunidades locales y regionales, peregrinando con escaso éxito a los centros concentrados del poder político y económico, para procurar los recursos financieros y humanos necesarios que no alcanzan a reponer los que se fugan desde hace décadas de sus localidades. Las empresas, con ciclos recurrentes de crecimiento y decrecimiento vinculados a los mercados en que colocan sus productos, también se debaten en la búsqueda de los escasos recursos, financieros y humanos, que les permitan consolidar un desarrollo a mediano y largo plazo. El desarrollo alcanzado en Sistemas de información, instrumentos de relevamiento, análisis y elaboración de propuestas para el Desarrollo Local, nos permite avanzar en: 1. La confirmación empírica de las hipótesis iniciales - factores exógenos y endógenos - en la zona Norte y Serrana de la provincia 2. La validación científica -mediante el Análisis de ecuaciones estructurales. de tales supuestos, para el conjunto de las poblaciones analizadas en ambas etapas. 3. La identificación de los problemas normativos que afectan el desarrollo de las Organizaciones de la Sociedad Civil (OSC). METODOLOGÍA Respecto la validación empírica en la zona norte y serrana 1. Selección de las 4 localidades a relevar de acuerdo a las categorías definidas 2. Elaboración de acuerdos con autoridades e instituciones locales. 3. Relevamiento cualitativo con líderes locales y fuentes de datos secundarias. 4. Adaptación de instrumentos de relevamiento a las realidades locales y estudios previos 5. Relevamiento cuantitativo de campo, capacitación de encuestadores y supervisores. 6. Procesamiento y elaboración de informes finales locales. Respecto de la construcción de modelos de desarrollo 1. Desarrollar las dimensiones especificas y las variables (items) de cada factor crítico. 2. Revisar el instrumento con expertos de cada una de las dimensiones. 3. Validar a nivel exploratorio por medio de un Análisis de Componentes Principales 4. Someter a los expertos la evaluación de una serie de localidades que representan cada uno. Respecto de la identificación de las normas legales que afectan a la Sociedad Civil 1.Relevamiento documental de normas 2. Relevamiento con líderes de instituciones de la Sociedad Civil 3. Análisis de las normas vigentes 4. Elaboración de Informes Finales y Transferencia a líderes e instituciones

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the global crisis o f climate change many countries throughout the world are installing the renewable energy o f wind power into their electricity system. Wind energy causes complications when it is being integrated into the electricity system due its intermittent nature. Additionally winds intennittency can result in penalties being enforced due to the deregulation in the electricity market. Wind power forecasting can play a pivotal role to ease the integration o f wind energy. Wind power forecasts at 24 and 48 hours ahead of time are deemed the most crucial for determining an appropriate balance on the power system. In the electricity market wind power forecasts can also assist market participants in terms o f applying a suitable bidding strategy, unit commitment or have an impact on the value o f the spot price. For these reasons this study investigates the importance o f wind power forecasts for such players as the Transmission System Operators (TSOs) and Independent Power Producers (IPPs). Investigation in this study is also conducted into the impacts that wind power forecasts can have on the electricity market in relation to bidding strategies, spot price and unit commitment by examining various case studies. The results o f these case studies portray a clear and insightful indication o f the significance o f availing from the information available from wind power forecasts. The accuracy o f a particular wind power forecast is also explored. Data from a wind power forecast is examined in the circumstances o f both 24 and 48 hour forecasts. The accuracy o f the wind power forecasts are displayed through a variety o f statistical approaches. The results o f the investigation can assist market participants taking part in the electricity pool and also provides a platform that can be applied to any forecast when attempting to define its accuracy. This study contributes significantly to the knowledge in the area o f wind power forecasts by explaining the importance o f wind power forecasting within the energy sector. It innovativeness and uniqueness lies in determining the accuracy o f a particular wind power forecast that was previously unknown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The classification or index of heart failure severity in patients with acute myocardial infarction (AMI) was proposed by Killip and Kimball aiming at assessing the risk of in-hospital death and the potential benefit of specific management of care provided in Coronary Care Units (CCU) during the decade of 60. Objective: To validate the risk stratification of Killip classification in the long-term mortality and compare the prognostic value in patients with non-ST-segment elevation MI (NSTEMI) relative to patients with ST-segment elevation MI (STEMI), in the era of reperfusion and modern antithrombotic therapies. Methods: We evaluated 1906 patients with documented AMI and admitted to the CCU, from 1995 to 2011, with a mean follow-up of 05 years to assess total mortality. Kaplan-Meier (KM) curves were developed for comparison between survival distributions according to Killip class and NSTEMI versus STEMI. Cox proportional regression models were developed to determine the independent association between Killip class and mortality, with sensitivity analyses based on type of AMI. Results: The proportions of deaths and the KM survival distributions were significantly different across Killip class >1 (p <0.001) and with a similar pattern between patients with NSTEMI and STEMI. Cox models identified the Killip classification as a significant, sustained, consistent predictor and independent of relevant covariables (Wald χ2 16.5 [p = 0.001], NSTEMI) and (Wald χ2 11.9 [p = 0.008], STEMI). Conclusion: The Killip and Kimball classification performs relevant prognostic role in mortality at mean follow-up of 05 years post-AMI, with a similar pattern between NSTEMI and STEMI patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background: The Walking Estimated-Limitation Calculated by History (WELCH) questionnaire has been proposed to evaluate walking impairment in patients with intermittent claudication (IC), presenting satisfactory psychometric properties. However, a Brazilian Portuguese version of the questionnaire is unavailable, limiting its application in Brazilian patients. Objective: To analyze the psychometric properties of a translated Brazilian Portuguese version of the WELCH in Brazilian patients with IC. Methods: Eighty-four patients with IC participated in the study. After translation and back-translation, carried out by two independent translators, the concurrent validity of the WELCH was analyzed by correlating the questionnaire scores with the walking capacity assessed with the Gardner treadmill test. To determine the reliability of the WELCH, internal consistency and test–retest reliability with a seven-day interval between the two questionnaire applications were calculated. Results: There were significant correlations between the WELCH score and the claudication onset distance (r = 0.64, p = 0.01) and total walking distance (r = 0.61, p = 0.01). The internal consistency was 0.84 and the intraclass correlation coefficient between questionnaire evaluations was 0.84. There were no differences in WELCH scores between the two questionnaire applications. Conclusion: The Brazilian Portuguese version of the WELCH presents adequate validity and reliability indicators, which support its application to Brazilian patients with IC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inductive learning aims at finding general rules that hold true in a database. Targeted learning seeks rules for the predictions of the value of a variable based on the values of others, as in the case of linear or non-parametric regression analysis. Non-targeted learning finds regularities without a specific prediction goal. We model the product of non-targeted learning as rules that state that a certain phenomenon never happens, or that certain conditions necessitate another. For all types of rules, there is a trade-off between the rule's accuracy and its simplicity. Thus rule selection can be viewed as a choice problem, among pairs of degree of accuracy and degree of complexity. However, one cannot in general tell what is the feasible set in the accuracy-complexity space. Formally, we show that finding out whether a point belongs to this set is computationally hard. In particular, in the context of linear regression, finding a small set of variables that obtain a certain value of R2 is computationally hard. Computational complexity may explain why a person is not always aware of rules that, if asked, she would find valid. This, in turn, may explain why one can change other people's minds (opinions, beliefs) without providing new information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actualment, la resposta de la majoria d’instrumentació operacional i dels dosímetres personals utilitzats en radioprotecció per a la dosimetria neutrònica és altament dependent de l’energia dels espectres neutrònics a analitzar, especialment amb camps neutrònics amb una important component intermitja. En conseqüència, la interpretació de les lectures d’aquests aparells es complicada si no es té un coneixement previ de la distribució espectral de la fluència neutrònica en els punts d’interès. El Grup de Física de les Radiacions de la Universitat Autònoma de Barcelona (GFR-UAB) ha desenvolupat en els últims anys un espectròmetre de neutrons basat en un Sistema d’Esferes Bonner (BSS) amb un contador proporcional d’3He com a detector actiu. Els principals avantatges dels espectròmetres de neutrons per BSS són: la seva resposta isotròpica, la possibilitat de discriminar la component neutrònica de la gamma en camps mixtos, i la seva alta sensibilitat neutrònica als nivells de dosi analitzats. Amb aquestes característiques, els espectròmetres neutrònics per BSS compleixen amb els estándards de les últimes recomanacions de la ICRP i poden ser utilitzats també en el camp de la dosimetria neutrònica per a la mesura de dosis en el rang d’energia que va dels tèrmics fins als 20 MeV, en nou ordres de magnitud. En el marc de la col•laboració entre el GFR - UAB i el Laboratorio Nazionale di Frascati – Istituto Nazionale di Fisica Nucleare (LNF-INFN), ha tingut lloc una experiència comparativa d’espectrometria per BSS amb els feixos quasi monoenergètics de 2.5 MeV i 14 MeV del Fast Neutron Generator de l’ENEA. En l’exercici s’ha determinat l’espectre neutrònic a diferents distàncies del blanc de l’accelerador, aprofitant el codi FRUIT recentment desenvolupat pel grup LNF. Els resultats obtinguts mostren una bona coherència entre els dos espectròmetres i les dades mesurades i simulades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nitroimidazole-tiadiazole derivative CL 64,855 (2-amino-5-(1-methyl-5-nitro-2-imidazolyl)-1,3,4-thiadiazole, a potent anti-trypanosomal drug, was assayed in a short-term bacterial mutagenicity test with Salmonella typhimurium strains TA 98, TA 100 and TA 102. Results indicate that CL 64,855 is a potent frameshift mutagen detected by strains TA 98 and TA 102. CL 64,855 was able to revert the indicators strains at concentrations as low as 0.1 µg/plate. Metabolic activation experiments with rat liver microsomal fractions did not increase the mutagenic action of Cl 64,855.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two techniques for rapid diagnosis, immunofluorescence (IFAT) and enzyme immunoassay (EIA), have been compared with virus isolaion in tissue culture for the detection of respiratory syncytial virus (RSV) in specimens of nasopharyngeal secretions. The specimens were obtained from children under five years of age suffering from acute respiratory iliness, during a period of six months from January to June 1982. Of 471 specimens examined 54 (11.5%) were positive by virus isolation and 180 (38.2%) were positive by immunofluorescence. The bacterial contamination of inoculated tissue cultures unfortunately prevented the isolation of virus from many samples. Specimens from 216 children were tested to compare enzyme immunoassay and immunofluorescence. Of these 60 (27%) were positive by EIA and 121 (56%) were positive by IFAT. Our results suggest that the EIA technique although highly specific is rather insensitive. This may be because by the time these tests were done the originl nasopharyngeal secretions were considerably diluted and contained more mucus fragments than the call suspension used for IFAT. Of the three techniques, IFAT gives the best results although EIA may be useful where IFAT is not possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular monitoring of BCR/ABL transcripts by real time quantitative reverse transcription PCR (qRT-PCR) is an essential technique for clinical management of patients with BCR/ABL-positive CML and ALL. Though quantitative BCR/ABL assays are performed in hundreds of laboratories worldwide, results among these laboratories cannot be reliably compared due to heterogeneity in test methods, data analysis, reporting, and lack of quantitative standards. Recent efforts towards standardization have been limited in scope. Aliquots of RNA were sent to clinical test centers worldwide in order to evaluate methods and reporting for e1a2, b2a2, and b3a2 transcript levels using their own qRT-PCR assays. Total RNA was isolated from tissue culture cells that expressed each of the different BCR/ABL transcripts. Serial log dilutions were prepared, ranging from 100 to 10-5, in RNA isolated from HL60 cells. Laboratories performed 5 independent qRT-PCR reactions for each sample type at each dilution. In addition, 15 qRT-PCR reactions of the 10-3 b3a2 RNA dilution were run to assess reproducibility within and between laboratories. Participants were asked to run the samples following their standard protocols and to report cycle threshold (Ct), quantitative values for BCR/ABL and housekeeping genes, and ratios of BCR/ABL to housekeeping genes for each sample RNA. Thirty-seven (n=37) participants have submitted qRT-PCR results for analysis (36, 37, and 34 labs generated data for b2a2, b3a2, and e1a2, respectively). The limit of detection for this study was defined as the lowest dilution that a Ct value could be detected for all 5 replicates. For b2a2, 15, 16, 4, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. For b3a2, 20, 13, and 4 labs showed a limit of detection at the 10-5, 10-4, and 10-3 dilutions, respectively. For e1a2, 10, 21, 2, and 1 lab(s) showed a limit of detection at the 10-5, 10-4, 10-3, and 10-2 dilutions, respectively. Log %BCR/ABL ratio values provided a method for comparing results between the different laboratories for each BCR/ABL dilution series. Linear regression analysis revealed concordance among the majority of participant data over the 10-1 to 10-4 dilutions. The overall slope values showed comparable results among the majority of b2a2 (mean=0.939; median=0.9627; range (0.399 - 1.1872)), b3a2 (mean=0.925; median=0.922; range (0.625 - 1.140)), and e1a2 (mean=0.897; median=0.909; range (0.5174 - 1.138)) laboratory results (Fig. 1-3)). Thirty-four (n=34) out of the 37 laboratories reported Ct values for all 15 replicates and only those with a complete data set were included in the inter-lab calculations. Eleven laboratories either did not report their copy number data or used other reporting units such as nanograms or cell numbers; therefore, only 26 laboratories were included in the overall analysis of copy numbers. The median copy number was 348.4, with a range from 15.6 to 547,000 copies (approximately a 4.5 log difference); the median intra-lab %CV was 19.2% with a range from 4.2% to 82.6%. While our international performance evaluation using serially diluted RNA samples has reinforced the fact that heterogeneity exists among clinical laboratories, it has also demonstrated that performance within a laboratory is overall very consistent. Accordingly, the availability of defined BCR/ABL RNAs may facilitate the validation of all phases of quantitative BCR/ABL analysis and may be extremely useful as a tool for monitoring assay performance. Ongoing analyses of these materials, along with the development of additional control materials, may solidify consensus around their application in routine laboratory testing and possible integration in worldwide efforts to standardize quantitative BCR/ABL testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Captan and folpet are fungicides largely used in agriculture. They have similar chemical structures, except that folpet has an aromatic ring unlike captan. Their half-lives in blood are very short, given that they are readily broken down to tetrahydrophthalimide (THPI) and phthalimide (PI), respectively. Few authors measured these biomarkers in plasma or urine, and analysis was conducted either by gas chromatography coupled to mass spectrometry or liquid chromatography with UV detection. The objective of this study was thus to develop simple, sensitive and specific liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) methods to quantify both THPI and PI in human plasma and urine. Briefly, deuterated THPI was added as an internal standard and purification was performed by solid-phase extraction followed by LC/APCI-MS/MS analysis in negative ion mode for both compounds. Validation of the methods was conducted using spiked blank plasma and urine samples at concentrations ranging from 1 to 250 μg/L and 1 to 50 μg/L, respectively, along with samples of volunteers and workers exposed to captan or folpet. The methods showed a good linearity (R (2) > 0.99), recovery (on average 90% for THPI and 75% for PI), intra- and inter-day precision (RSD, <15%) and accuracy (<20%), and stability. The limit of detection was 0.58 μg/L in urine and 1.47 μg/L in plasma for THPI and 1.14 and 2.17 μg/L, respectively, for PI. The described methods proved to be accurate and suitable to determine the toxicokinetics of both metabolites in human plasma and urine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the accuracy of 4 clinical instruments in the detection of glaucomatous damage. Methods: 102 eyes of 55 test subjects (Age mean = 66.5yrs, range = [39; 89]) underwent Heidelberg Retinal Tomography (HRTIII), (disc area<2.43); and standard automated perimetry (SAP) using Octopus (Dynamic); Pulsar (TOP); and Moorfields Motion Displacement Test (MDT) (ESTA strategy). Eyes were separated into three groups 1) Healthy (H): IOP<21mmHg and healthy discs (clinical examination), 39 subjects, 78 eyes; 2) Glaucoma suspect (GS): Suspicious discs (clinical examination), 12 subjects, 15 eyes; 3) Glaucoma (G): progressive structural or functional loss, 14 subjects, 20 eyes. Clinical diagnostic precision was examined using the cut-off associated with the p<5% normative limit of MD (Octopus/Pulsar), PTD (MDT) and MRA (HRT) analysis. The sensitivity, specificity and accuracy were calculated for each instrument. Results: See table Conclusions: Despite the advantage of defining glaucoma suspects using clinical optic disc examination, the HRT did not yield significantly higher accuracy than functional measures. HRT, MDT and Octopus SAP yielded higher accuracy than Pulsar perimetry, although results did not reach statistical significance. Further studies are required to investigate the structure-function correlations between these instruments.