876 resultados para Force plate
Resumo:
Includes bibliography
Resumo:
Introduction: Elastomeric materials are considered important sources of orthodontic forces. Objective: To assess force degradation over time of four commercially available orthodontic elastomeric chains (Morelli, Ormco, TP and Unitek). Methods: The synthetic elastics were submerged in 37 oC synthetic saliva and stretched by a force of 150 g (15 mm - Morelli and TP; 16mm - Unitek and Ormco). With a dynamometer, the delivered force was evaluated at different intervals: 30 minutes, 7 days, 14 days and 21 days. The results were subjected to ANOVA and Tukey's test. Results: There was a force decay between 19% to 26.67% after 30 minutes, and 36.67% to 57% after 21 days of activation. Conclusions: TP elastomeric chains exhibited the smallest percentage of force decay, with greater stability at all time intervals tested. Meanwhile, the Unitek chains displayed the highest percentage of force degradation, and no statically significant difference was found in force decay between Ormco and Morelli elastomeric chains during the study period.
Resumo:
The dynamics of the AFM-atomic force microscope follows a model based in a Timoshenko cantilever beam with a tip attached at the free end and acting with the surface of a sample. General boundary conditions arise when the tip is either in contact or non-contact with the surface. The governing equations are given in matrix conservative form subject to localized loads. The eigenanalysis is done with a fundamental matrix response of a damped second-order matrix differential equation. Forced responses are found by using a Galerkin approximation of the matrix impulse response. Simulations results with harmonic and pulse forcing show the filtering character and the effects of the tip-sample interaction at the end of the beam. © 2012 American Institute of Physics.
Resumo:
This paper describes an image compounding technique based on the use of different apodization functions, the evaluation of the signals phases and information from the interaction of different propagation modes of Lamb waves with defects for enhanced damage detection, resolution and contrast. A 16 elements linear array is attached to a 1 mm thickness isotropic aluminum plate with artificial defects. The array can excite the fundamental A0 and S0 modes at the frequencies of 100 kHz and 360 kHz, respectively. For each mode two synthetic aperture (SA) images with uniform and Blackman apodization and one image of Coherence Factor Map (CFM) are obtained. The specific interaction between each propagation mode and the defects and the characteristics of acoustic radiation patterns due to different apodization functions result in images with different resolution and contrast. From the phase information one of the SA images is selected at each pixel to compound the final image. The SA images are multiplied by the CFM image to improve contrast and for the dispersive A0 mode it is used a technique for dispersion compensation. There is a contrast improvement of 47.5 dB, reducing the dead zone and improving resolution and damage detection. © 2012 IEEE.
Resumo:
The aim of this study was to investigate the effect of fatigue induced by an exhaustive laboratory-based soccer-specific exercise on different hamstrings/quadriceps (H:Q) ratios of soccer players. Twenty-two male professional soccer players (23·1 ± 3·4 year) performed maximal eccentric (ecc) and concentric (con) contractions for knee extensors (KE) and flexors (KF) at 60° s-1 and 180° s-1 to assess conventional (Hcon:Qcon) and functional (Hecc:Qcon) ratios. Additionally, they performed maximal voluntary isometric contraction for KE and KF, from which the maximal muscle strength, rate of force development (RFD) and RFD H:Q strength ratio (RFDH:Q) were extracted. Thereafter, subjects were performed an exhaustive laboratory-based soccer-specific exercise and a posttest similar to the pretest. There was significant reduction in Hcon:Qcon (0·60 ± 0·06 versus 0·58 ± 0·06, P<0·05) and in Hecc:Qcon (1·29 ± 0·2 versus 1·16 ± 0·2, P<0·01) after the soccer-specific exercise. However, no significant difference between Pre and Post exercise conditions was found for RFDH:Q at 0-50 (0·53 ± 0·23 versus 0·57 ± 0·24, P>0·05) and 0-100 ms (0·53 ± 0·17 versus 0·55 ± 0·17, P>0·05). In conclusion, H:Q strength ratios based on peak force values are more affected by fatigue than RFDH:Q obtained during early contraction phase. Thus, fatigue induced by soccer-specific intermittent protocol seems not reduce the potential for knee joint stabilization during the initial phase of voluntary muscle contraction. copy; 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.
Resumo:
This study aimed to determine whether: i) tethered-swimming can be used to identify the asymmetry during front crawl swimming style; ii) swimmers that perform unilateral breathing present greater asymmetry in comparison to others that use bilateral breathing; iii) swimmers of best performance present smaller asymmetry than their counterparts; iv) repeated front crawl swimming movements influence body asymmetry. 18 swimmers were assessed for propulsive force parameters (peak force, mean force, impulse and rate of force development) during a maximal front crawl tethered-swimming test lasting 2 min. A factorial analysis showed that propulsive forces decreased at the beginning, intermediate and end of the test (p<0.05), but the asymmetries were not changed at different instants of the test. When breathing preference (uni- or bilateral) was analyzed, asymmetry remained unchanged in all force parameters (p>0.05). When performance was considered (below or above mean group time), a larger asymmetry was found in the sub-group of lower performance in comparison to those of best performance (p<0.05). Therefore, the asymmetries of the propulsive forces can be detected using tethered-swimming. The propulsive forces decreased during the test but asymmetries did not change under testing conditions. Although breathing preference did not influence asymmetry, swimmers with best performance were less asymmetric than their counterparts. © Georg Thieme Verlag KG Stuttgart New York.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Includes bibliography
The effect of locked screw angulation on the biomechanical properties of the S.P.S. Free-Block plate
Resumo:
Objectives: Among the locked internal fixators is one denominated S.P.S. (Synthesis Pengo System) Free-Block, which was designed with a locking ring that allows the screw to be locked and positioned obliquely. Due to the paucity of biomechanical studies on this system, the present work aimed to evaluate the influence of locked screw angulation on the resistance of the S.P.S. Free--Block plate. Methods: Forty synthetic bone cylinders with 10 mm fracture gap were used. Forty seven-hole 3.5 mm stainless steel plates (two AO-like dynamic compression holes and five locked holes) were assembled according to the orientation of the locked screws: mono cortical screws were positioned at 90° to the long axis of the cylinder (Group 1), and monocortical screws were positioned at 70° to its cylinder long axis (Group 2). In both groups, AO-like dynamic compression hole screws were positioned bicortically and neutrally. For each group, six specimens were tested until failure, three in bending and three in compression, to determine the loads for fatigue testing. Subsequently, for each group, 14 specimens were tested for failure --seven by bending and seven in compression. Results: No significant failure differences were observed between Groups 1 and 2 under static-loading or fatigue test. Clinical significance: In a fracture gap model the orientation of the locked monocortical screws did not show any influence on the mechanical performance of the S.P.S. Free-Block to tests of axial compression and four-point bending. © Schattauer 2013.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: The relationship between normal and tangential force components (grip force - GF and load force - LF, respectively) acting on the digits-object interface during object manipulation reveals neural mechanisms involved in movement control. Here, we examined whether the feedback type provided to the participants during exertion of LF would influence GF-LF coordination and task performance. Methods. Sixteen young (24.7 ±3.8 years-old) volunteers isometrically exerted continuously sinusoidal FZ (vertical component of LF) by pulling a fixed instrumented handle up and relaxing under two feedback conditions: targeting and tracking. In targeting condition, FZ exertion range was determined by horizontal lines representing the upper (10 N) and lower (1 N) targets, with frequency (0.77 or 1.53 Hz) dictated by a metronome. In tracking condition, a sinusoidal template set at similar frequencies and range was presented and should be superposed by the participants' exerted FZ. Task performance was assessed by absolute errors at peaks (AEPeak) and valleys (AEValley) and GF-LF coordination by GF-LF ratios, maximum cross-correlation coefficients (r max), and time lags. Results: The results revealed no effect of feedback and no feedback by frequency interaction on any variable. AE Peak and GF-LF ratio were higher and rmax lower at 1.53 Hz than at 0.77 Hz. Conclusion: These findings indicate that the type of feedback does not influence task performance and GF-LF coordination. Therefore, we recommend the use of tracking tasks when assessing GF-LF coordination during isometric LF exertion in externally fixed instrumented handles because they are easier to understand and provide additional indices (e.g., RMSE) of voluntary force control. © 2013 Pedão et al.; licensee BioMed Central Ltd.
Resumo:
Quantitative variations in heterotrophic plate count (HPC) and in the presence of indicator microorganisms in 0.5, 1.5 and 20-L bottles of different brands of Brazilian mineral water were analyzed during their shelf life. No variations were identified in the presence of indicator microorganisms, but quantitative variations in HPC were observed in some brands, which suggests that changes may be occurring in the water quality during storage. The aim of this study was also to evaluate the quality of the bottled mineral waters and the presence of enterococci and Pseudomonas aeruginosa were verified in six and two bottles, respectively, which is in disagreement with the microbiological quality criteria established in the current legislation. Although no limit is set for HPC in mineral water, this study relies on the limit of 500 colony-forming units per mL of sample (CFU/mL). Seventy-two bottles presented levels above 500 CFU/mL and up to 560,000 CFU/mL. This study showed that the control of HPC (<500 CFU/mL) for non-returnable packaging seems to be adequate to ensure the quality of mineral water during storage. The high values of HPC and its variations detected during storage seem to fully justify the need for a reevaluation of the use of HPC in bottled mineral water quality management. More detailed studies on the potential health risk of HPC and its variations in mineral water are also needed. © 2012 Elsevier Ltd.
Resumo:
The performance of the optimal linear feedback control and of the state-dependent Riccati equation control techniques applied to control and to suppress the chaotic motion in the atomic force microscope are analyzed. In addition, the sensitivity of each control technique regarding to parametric uncertainties are considered. Simulation results show the advantages and disadvantages of each technique. © 2013 Brazilian Society for Automatics - SBA.
Resumo:
Poor posture control has been associated with an increased risk of falls and mobility disability among older adults. This study was conducted to assess the test-retest reliability and sensitivity to group differences regarding the time-limit (TLimit) of one-leg standing and selected balance parameters obtained with a force platform in older and young adults. A secondary purpose was to assess the relationship between TLimit and these balance parameters. Twenty-eight healthy older adults (age: 69±5years) and thirty young adults (age: 21±4years) participated in this study. Two one-leg stance tasks were performed: (1) three trials of 30s maximum and (2) one TLimit trial. The following balance parameters were computed: center of pressure area, RMS sway amplitude, and mean velocity and mean frequency in both the anterio-posterior and medio-lateral directions. All balance parameters obtained with the force platform as well as the TLimit variable were sensitive to differences in balance performance between older and young adults. The test-retest reliability of these measures was found to be acceptable (ICC: 0.40-0.85), with better ICC scores observed for mean velocity and mean frequency in the older group. Pearson correlations coefficients (r) between balance parameters and TLimit ranged from -0.16 to -0.54. These results add to the current literature that can be used in the development of measurement tools for evaluating balance in older and young adults. © 2013 Elsevier Ltd.