1. Lough Neagh and Lough Beg Special Protection Area (SPA, hereafter Lough Neagh) is an important non-estuarine site in Britain and Ireland for overwintering wildfowl. Multivariate analysis of the winter counts showed a state-shift in the waterbird community following winter 2000/2001, mostly due to rapid declines in abundance (46–57% declines in the mean mid-winter January counts between 1993–2000 and 2002–2009) of members of the diving duck guild (pochard Aythya ferina, tufted duck Aythya fuligula and goldeneye Bucephala clangula) and coot (Fulica atra), a submerged macrophyte feeder.
2. Only pochard showed correlations between declines at Lough Neagh and those of overall species flyway population indices to suggest that global changes could contribute to declines at the site. However, indices from the Republic of Ireland showed no overall decline in the rest of Ireland. Tufted duck indices at the site were inversely related to indices in Great Britain. Lough Neagh goldeneye indices were positively correlated with indices in the Republic of Ireland and Great Britain, suggesting that short-stopping could contribute to declines at the site. Coot declines at Lough Neagh did not correlate with trends elsewhere, suggesting local factors involved in the decline.
3. These analyses indicate that although there are potentially different explanations for the dramatic declines in these four waterbird species at this site, the simultaneous nature of the declines across two feeding guilds strongly
suggest that local factors (such as loss of submerged macrophytes and benthic invertebrates) were involved. An assessment of the food supply, local disturbance and other factors at Lough Neagh is required to find an explanation for the observed adverse trends in wintering numbers of the affected species.
4. This study highlights the potential of waterbird community structure to reflect the status of aquatic systems, but confirms the need to establish site-specific factors responsible for the observed changes in abundance of key waterbird species at a site.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the authors have presented one approach to configuring a Wafer-Scale Integration Chip. The approach described is called the 'WINNER', in which bus channels and an external controller for configuring the working processors are not required. In addition, the technique is applicable to high availability systems constructed using conventional methods. The technique can also be extended to arrays of arbitrary size and with any degree of fault tolerance simply by using an appropriate number of cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is acknowledged that wind power is a stochastic energy source compared to hydroelectric generation which is easily scheduled. In this paper a scheme for coordinating wind power plant and hydroelectric power plant is presented by using PMUs to measure and control the state of wind and hydro power plants. Hydroelectric generation is proposed as a method of energy reserve and compensation in the context of wind power fluctuation in order to avoid full or partial curtailment of wind generation to benefit wind providers. The feasibility of this proposed scheme is investigated by power flow calculation and stability analysis using the IEEE 30-bus power system model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a voltage and power quality enhancement scheme for a doubly-fed induction generator (DFIG) wind farm during variable wind conditions. The wind profiles were derived considering the measured data at a DFIG wind farm located in Northern Ireland (NI). The aggregated DFIG wind farm model was validated using measured data at a wind farm during variable generation. The voltage control strategy was developed considering the X/R ratio of the wind farm feeder which connects the wind farm and the grid. The performance of the proposed strategy was evaluated for different X/R ratios, and wind profiles with different characteristics. The impact of flicker propagation along the wind farm feeder and effectiveness of the proposed strategy is also evaluated with consumer loads connected to the wind farm feeder. It is shown that voltage variability and short-term flicker severity is significantly reduced following implementation of the novel strategy described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a calculation method to determine power system response during small load perturbations or minor disturbances. The method establishes the initial value of active power transient using traditional reduction technique on admittance matrix, which incorporates voltage variations in the determination. The method examines active power distribution among generators when several loads simultaneously change, and verifies that the superposition principle is applicable for this scenario. The theoretical derivation provided in the paper is validated by numerical simulations using a 3-generator 9-bus benchmark model. The results indicate that the inclusion of voltage variation renders an independent and precise measure of active power response during transient conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rapid growth of wind generation in many European countries is pushing power systems into
uncharted territory. As additional wind generators are installed, the changing generation mix may
impact on power system stability. This paper adopts the New England 39 bus system as a test
system for transient stability analysis. Thermal generator models are based on a likely future plant
mix for existing systems, while varying capacities of fixed-speed induction generators (FSIG) and
doubly-fed induction generators (DFIG) are considered. The main emphasis here has been placed
on the impact of wind technology mix on inter-area oscillations following transient grid
disturbances. In addition, both rotor angle stability and transient voltage stability are examined, and
results are compared with current grid code requirements and standards. Results have shown that
FSIGs can reduce tie-line oscillations and improve damping following a transient disturbance, but
they also cause voltage stability and rotor angle stability problems at high wind penetrations. In
contrast, DFIGs can improve both voltage and rotor angle stability, but their power output
noticeably oscillates during disturbances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents transient stability analysis for a power system with high wind penetration. The transient stability has been evaluated based on two stability criteria: rotor angle stability and voltage stability. A modified IEEE-14 bus system has been used as the main study network and simulations have been conducted at several wind power penetration levels, defined as a fraction of total system generation. A wide range of scenarios have been presented based on the wind farm voltage at the point of connection, i.e. low voltage (LV) distribution level and high voltage (HV) transmission level, and the type of wind generator technology, i.e. fixed speed induction generator (FSIG) and doubly-fed induction generator (DFIG).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a method to assess the small signal stability of a power system network by selective determination of the modal eigenvalues. This uses an accelerating polynomial transform, designed using approximate eigenvalues
obtained from a wavelet approximation. Application to the IEEE 14 bus network model produced computational savings of 20%,over the QR algorithm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Scalability and efficiency of on-chip communication of emerging Multiprocessor System-on-Chip (MPSoC) are critical design considerations. Conventional bus based interconnection schemes no longer fit for MPSoC with a large number of cores. Networks-on-Chip (NoC) is widely accepted as the next generation interconnection scheme for large scale MPSoC. The increase of MPSoC complexity requires fast and accurate system-level modeling techniques for rapid modeling and veri-fication of emerging MPSoCs. However, the existing modeling methods are limited in delivering the essentials of timing accuracy and simulation speed. This paper proposes a novel system-level Networks-on-Chip (NoC) modeling method, which is based on SystemC and TLM2.0 and capable of delivering timing accuracy close to cycle accurate modeling techniques at a significantly lower simulation cost. Experimental results are presented to demonstrate the proposed method. ©2010 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For The Map of Watchful Architecture I only concerned myself with defensive architecture along the Border. As the map followed a border it came out as a wavy line of points. This was largely artificial, I only charted architecture within the Border corridor, but was not entirely artificial. That linear landscape has long been staked-out by the regularity of certain kinds of architecture. The 1st/2nd century Black Pig’s Dyke and Dorsey correspond with today’s Border. The concentration of souterrains in north Louth indicate that it may have been a volatile interface zone in later centuries. In 1618 Londonderry and its walls were built. Further north and two centuries later, Martello Towers were constructed to watch over Lough Foyle. During the Second World War pillboxes and observation posts were manned along the Border, close to what was now an international frontier. Then came the Operation Banner installations built during The Troubles. All this adds up to be one of the longest unbroken traditions of defensive architecture anywhere in Western Europe, a tradition some thought finally broken as the last of the Operation Banner towers were de-installed in 2007. But, take a bus south across the Border and you will often be pulled over by the Garda Síochána. They ID check the passengers in an attempt to stop illegal immigration via the UK. What about illegal immigrants who walk through the fields or along quiet lanes? They will have understood the Border is not really how it seems on most maps. It is not a solid line, it is a row of points.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents a new method for determining the transmission network usage by loads and generators, which can then be used for transmission cost/loss allocation in an explainable and justifiable manner. The proposed method is based on solid physical grounds and circuit theory. It relies on dividing the currents through the network into two components; the first one is attributed to power flows from generators to loads, whereas the second one is because of the generators only. Unlike almost all the available methods, the proposed method is assumption free and hence it is more accurate than similar methods even those having some physical basis. The proposed method is validated through a transformer analogy, and theoretical derivations. The method is verified through application to the IEEE 30 bus system and the IEEE 118 test system. The results obtained verified many desirable features of the proposed method. Being more accurate in determining the network usage, in an explainable transparent manner, and in giving accurate cost signals, indicating the best locations to add loads and generation, are among the many desirable features.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this paper is to develop a new generation of extruder control system for recycled materials which has ability to automatically maintain constant a polymer melt viscosity of mixed recycled polymers during extrusion, regardless of variations in the Melt Flow Index (MFI) of recycled mixed grade high density polyethylene (HDPE) feedstock. The variations in MFI are due to differences in the source of the recycled material used. The work describes how melt viscosity for specific extruder/die system is calculated in real time using the rheological properties of the materials, the pressure drop through the extruder die and the actual throughput measurements using a gravimetric loss-in-weight hopper feeder. A closed-loop controller is also developed to automatically regulate screw speed and barrel temperature profile to achieve constant viscosity and enable consistent processing of variable grade recycled HDPE materials. Such a system will improve processability of mixed MFI polymers may also reduce the risk of polymer melt degradation, reduce producing large volumes of scrap/waste and lead to improvement in product quality. The experimental results of real time viscosity measurement and control using a 38 mm single screw extruder with different recycled HDPEs with widely different MFIs are reported in this work.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a new method for online determination of the Thèvenin equivalent parameters of a power system at a given node using the local PMU measurements at that node. The method takes into account the measurement errors and the changes in the system side. An analysis of the effects of changes in system side is carried out on a simple two-bus system to gain an insight of the effect of system side changes on the estimated Thévenin equivalent parameters. The proposed method uses voltage and current magnitudes as well as active and reactive powers; thus avoiding the effect of phase angle drift of the PMU and the need to synchronize measurements at different instances to the same reference. Applying the method to the IEEE 30-bus test system has shown its ability to correctly determine the Thévenin equivalent even in the presence of measurement errors and/or system side changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new method is presented for transmission loss allocation based on the separation of transmission loss caused by load and the loss due to circulating currents between generators. The theoretical basis for and derivation of the loss formulae are presented using simple systems. The concept is then extended to a general power system using the Ybus model. Details of the application of the proposed method to a typical power system are presented along with results from the IEEE 30 bus test system. The results from both the small system and the standard IEEE test system demonstrate the validity of the proposed method.