879 resultados para Evoked potentials (Electrophysiology)
Resumo:
The present study used electrical stimulation to distinguish the vesicular from the cytoplasmic component of transmitter release in human autopsy synaptosomes. We demonstrate that the present electrical stimulation paradigm can elicit successive release pulses from synaptosome preparation.
Resumo:
A prática do ioga tem se tornado cada vez mais popular, não apenas pelos benefícios físicos, mas principalmente pelo bem-estar psicológico trazido pela sua prática. Um dos componentes do ioga é o Prãnãyama, ou controle da respiração. A atenção e a respiração são dois mecanismos fisiológicos e involuntários requeridos para a execução do Prãnãyama. O principal objetivo desse estudo foi verificar se variáveis contínuas do EEG (potência de diferentes faixas que o compõem) seriam moduladas pelo controle respiratório, comparando-se separadamente as duas fases do ciclo respiratório (inspiração e expiração), na situação de respiração espontânea e controlada. Fizeram parte do estudo 19 sujeitos (7 homens/12 mulheres, idade média de 36,89 e DP = ± 14,46) que foram convidados a participar da pesquisa nas dependências da Faculdade de Saúde da Universidade Metodista de São Paulo. Para o registro do eletroencefalograma foi utilizado um sistema de posicionamento de cinco eletrodos Ag AgCl (FPz, Fz, Cz, Pz e Oz) fixados a uma touca de posicionamento rápido (Quick-Cap, Neuromedical Supplies®), em sistema 10-20. Foram obtidos valores de máxima amplitude de potência (espectro de potência no domínio da frequência) nas frequências teta, alfa e beta e delta e calculada a razão teta/beta nas diferentes fases do ciclo respiratório (inspiração e expiração), separadamente, nas condições de respiração espontânea e de controle respiratório. Para o registro do ciclo respiratório, foi utilizada uma cinta de esforço respiratório M01 (Pletismógrafo). Os resultados mostram diferenças significativas entre as condições de respiração espontânea e de controle com valores das médias da razão teta/beta menores na respiração controlada do que na respiração espontânea e valores de média da potência alfa sempre maiores no controle respiratório. Diferenças significativas foram encontradas na comparação entre inspiração e expiração da respiração controlada com diminuição dos valores das médias da razão teta/beta na inspiração e aumento nos valores das médias da potência alfa, sobretudo na expiração. Os achados deste estudo trazem evidências de que o controle respiratório modula variáveis eletrofisiológicas relativas à atenção refletindo um estado de alerta, porém mais relaxado do que na situação de respiração espontânea.
Resumo:
This study used magnetoencephalography (MEG) to examine the dynamic patterns of neural activity underlying the auditory steady-state response. We examined the continuous time-series of responses to a 32-Hz amplitude modulation. Fluctuations in the amplitude of the evoked response were found to be mediated by non-linear interactions with oscillatory processes both at the same source, in the alpha and beta frequency bands, and in the opposite hemisphere. © 2005 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Parkinson's disease (PD) is associated with enhanced synchronization of neuronal network activity in the beta (15-30 Hz) frequency band across several nuclei of the basal ganglia (BG). Deep brain stimulation of the subthalamic nucleus (STN) appears to reduce this pathological oscillation, thereby alleviating PD symptoms. However, direct stimulation of primary motor cortex (M1) has recently been shown to be effective in reducing symptoms in PD, suggesting a role for cortex in patterning pathological rhythms. Here, we examine the properties of M1 network oscillations in coronal slices taken from rat brain. Oscillations in the high beta frequency range (layer 5, 27.8 +/- 1.1 Hz, n=6) were elicited by co-application of the glutamate receptor agonist kainic acid (400 nM) and muscarinic receptor agonist carbachol (50 mu M). Dual extracellular recordings, local application of tetrodotoxin and recordings in M1 micro-sections indicate that the activity originates within deep layers V/VI. Beta oscillations were unaffected by specific AMPA receptor blockade, abolished by the GABA type A receptor (GABAAR) antagonist picrotoxin and the gap-junction blocker carbenoxolone, and modulated by pentobarbital and zolpidem indicating dependence on networks of GABAergic interneurons and electrical coupling. High frequency stimulation (HFS) at 125 Hz in superficial layers, designed to mimic transdural/transcranial stimulation, generated gamma oscillations in layers 11 and V (incidence 95%, 69.2 +/- 7.3 Hz, n=17) with very fast oscillatory components (VFO; 100-250 Hz). Stimulation at 4 Hz, however, preferentially promoted theta activity (incidence 62.5%, 5.1 +/- 0.6 Hz, n=15) that effected strong amplitude modulation of ongoing beta activity. Stimulation at 20 Hz evoked mixed theta and gamma responses. These data suggest that within M1, evoked theta, gamma and fast oscillations may coexist with and in some cases modulate pharmacologically induced beta oscillations.
Resumo:
The latency variation of the P100M from minute to minute, between morning and afternoon and from day to day was investigated in an unshielded environment using two single channel magnetometers. Latency variation was greatest from minute to minute with relatively little longer term variation. The two magnetometers differed both in mean latency and in the degree of variation. This may be attributed to variation in the performance of the filters which were set a narrow bandwidth for recording in an unshielded environment.
Resumo:
We discuss the application of beamforming techniques to the field of magnetoencephalography (MEG). We argue that beamformers have given us an insight into the dynamics of oscillatory changes across the cortex not explored previously with traditional analysis techniques that rely on averaged evoked responses. We review several experiments that have used beamformers, with special emphasis on those in which the results have been compared to those observed in functional magnetic resonance imaging (fMRI) and on those studying induced phenomena. We suggest that the success of the beamformer technique, despite the assumption that there are no linear interactions between the mesoscopic local field potentials across distinct cortical areas, may tell us something of the balance between functional integration and segregation in the human brain. What is more, MEG beamformer analysis facilitates the study of these complex interactions within cortical networks that are involved in both sensory-motor and cognitive processes. © 2005 Wiley-Liss, Inc.
Influence of check and field size on the visual evoked magnetic response to a pattern shift stimulus
Resumo:
A decrease in the check size of a pattern shift stimulus increases the latency and amplitude of the visual evoked potential (VEP) P100. In addition, for a given check size, decreasing the size of the stimulus field increases the latency and amplitude of the P100. These results imply that the central regions of the retina make a significant contribution to the generation of the electrical P100. However, the corresponding magnetic P100m may have a different origin. We have studied the effects of check and field size on the P100m in five normal subjects using a DC-Squid, second-order gradiometer. Magnetic responses were recorded at the positive maximum of the P100m over the occipital scalp to six check sizes (10-100') presented in a large (13 degrees 34') and small (5 degrees 14') field and to a large check (100') presented in seven field sizes (1 degree 45' - 15 degrees 10'). No responses were recorded to any check size with a small field. Decreasing the check size presented in a large field increased latency of the P100m by approx. 30 ms while the amplitude of the response decreased with the largest reduction occurring between 70' and 12' checks. Using a large check, latency increased and amplitude decreased as the field size was reduced. The latency changes in response to check and field size were similar to those described for the VEP although the magnitudes of the magnetic changes were greater. Unlike the VEP, amplitude responses were maximal when large checks were presented in a large stimulus field. This suggests that regions outside the central retina make a more significant contribution to the visual evoked magnetic response than they do to the VEP, and that the P100m may be useful clinically in the study of diseases that affect the more peripheral regions of the retina.