927 resultados para Distributed energy resources


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experiment was conducted to determine the chemical composition and apparent metabolizable energy (AME) and apparent metabolizable energy corrected for nitrogen balance (AMEn) values of corn, soybean meal (SBM), soybean oil (SO) and sugarcane yeast (SY) (Saccharomyces cerevisiae). A metabolism trial was performed with 120 Dekalb White laying hens at 65 weeks of age, using the method of total excreta collection. Birds were housed in metabolism cages and distributed according to a completely randomized design into five treatments with, six replicates of four birds each. The experimental period consisted of four days of adaptation and four days of excreta collection. The experimental diets included: a reference diet based on corn and SBM and four test diets containing 40% corn, 30% SBM, 10% SO or 30 % SY. The chemical compositions of the tested ingredients, expressed on "as-is" basis were: 86.9, 87.29, 87.32 and 99.5% dry matter; and 3.51, 2.08, 99.31 and 0.03 ether extract for corn, SBM, SO and SY, respectively. Corn, SBM, and SO presented 7.33, 43.61 and 24.64% crude protein, and 0.58, 5.07 and 6.77% ash, respectively; and crude fiber contents of corn and SBM were, respectively, 2.24% and 3.56%. The following AME and AMEn (kcal/kg dry matter) values were obtained: 3,801 and 3,760 kcal/kg for corn, 2,640 and 2,557 kcal/kg for SBM, 8,952 and 8,866 kcal/kg for SO, and 1,023 and 925 kcal/kg for sugarcane yeast, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated a nonlinear programming excel workbook PPFR (http://www.fmva.unesp.br/ppfr) for determining the optimum nutrient density and maximize margins. Two experiments were conducted with 240 one-day-old female chicks and 240 one-day-old male chicks distributed in 48 pens (10 chicks per pen, 4 replicates) in a completely randomized design. The treatments include the average price history (2009s and 2010s) for broiler increased and decreased by 25% or 50% (5 treatments to nonlinear feed formulation) and 1 linear feed formulation. Body gain, feed intake, feed conversion were measured at 21, 42 and 56 d of age. Chicks had ad libitum access to feed and water in floor pens with wood shavings as litter. The bio-economic Energy Conversion [BEC= (Total energy intake*Feed weighted cost per kg)/ (Weight gain*kg live chicken cost)] was more sensitive for measuring the bio-economic performance for broilers, and especially with better magnitude. This allowed a better assessment of profitability, the rate of growth and not just energy consumption, the production of broilers, by incorporating energy consumption, allowing for more sensitivity to the new index (BEC). The BEC was demonstrated that the principle of nonlinear formulation minimizes losses significantly (P<0.05), especially under unfavorable conditions the price of chicken in the market. Thus, when considering that a diet of energy supply shows up as the most expensive item of a formulation, it should compose necessarily the formula proposed for a bio-economic index. Thus, there is need to evaluate more accurately, not only the ingredients of a ration, but the impact of nutrients on the stability of a solution, mainly due to the energy requirement. This strategy promotes better accuracy for decision making under conditions of uncertainty, to find alternative post-formulation. From the above, both weight gain and feed conversion, as traditional performance indicators, cannot finalize or predict a performance evaluation of an economic system creating increasingly intense and competitive. Thus, the energy concentration of the diet becomes more important definition to feed formulator, by directly impact profit activity by interactions with the density of nutrients. This allowed a better evaluation of profitability, the rate of energy performance for broilers, by incorporating the energy consumption formula, allowing more sensitivity to the new index (BEC). These data show that nonlinear feed formulation is a toll to offer new opportunities for poultry production to improved profitability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thank you for this opportunity to speak with you today. It's always my pleasure to talk about the exciting work occurring in the Institute of Agriculture and Natural Resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the objective to establish the best metabolizable energy (ME) intake for layers, and the best dietary vegetable oil addition level to optimize egg production, an experiment was carried out with 432 30-week-old Hisex Brown layers. Birds were distributed into nine treatments with six replicates of eight birds each according to a 3 x 3 factorial arrangement, consisting of three daily metabolizable energy intake (280, 300 or 320 kcal/bird/day) and three oil levels (0.00; 0.75 and 1.50 g/bird/day). Daily feed intake was limited to 115, 110 and 105 g/bird in order to obtain the desired energy and oil intake in each treatment. The following parameters were evaluated: initial weight, final weight, body weight change, egg production, egg mass, feed conversion ratio per dozen eggs and per egg mass and energy conversion. There was no influence of the treatments on egg production (%) or egg mass (g/bird/day). Final weight and body weight change were significantly affected by increasing energy intake. Feed conversion ratio per egg mass, feed conversion ratio per dozen eggs and energy conversion significantly worsened as a function of the increase in daily energy intake. An energy intake of 280 kcal/bird/day with no addition of dietary oil does not affect layer performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effect of the supplementation of xylanase in diets with reduced energy level on the apparent metabolizable energy corrected for nitrogen, determined with laying hens at 14, 36, 60 and 80 weeks of age. Four digestibility trials were conducted, using 80 Hy-line W36 laying hens aged 14, 36, 60 and 80 weeks of age. Birds were distributed in a completely randomized design in 2 x 2 factorial arrangement (energy level x inclusion of xylanase), totaling four treatments with 10 replicates of two birds each. Treatments were: positive control (balanced diet for their age); positive control + xylanase; negative control (diet with reduction of 100 kcal/kg in the level of metabolizable energy); and negative control + xylanase. Xylanase, produced by microorganism Trichoderma reesei, was added to the diets at 100 g/t (16,000 BXU/kg) for diets fed at 14 weeks and 75 g/t for diets of 36, 60 and 80 weeks (12,000 BXU/kg). The data obtained were subjected to analysis of variance at 5% probability. Supplementation of xylanase promoted higher values for AME (apparent metabolizable energy) and AME(n) (apparent metabolizable energy corrected for nitrogen) determined with 80-week-old laying hens, subjected to diet with energy level according to the nutritional requirements for their age. Supplementation of xylanase increases the matabolizability coefficient of the dietary crude protein and improves the nitrogen retention of laying hens at 14 weeks. In addition, xylanase associated with adequate levels of dietary energy promotes higher values for AME and AME(n) determined with laying hens at 80 weeks of age.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The installation of induction distributed generators should be preceded by a careful study in order to determine if the point of common coupling is suitable for transmission of the generated power, keeping acceptable power quality and system stability. In this sense, this paper presents a simple analytical formulation that allows a fast and comprehensive evaluation of the maximum power delivered by the induction generator, without losing voltage stability. Moreover, this formulation can be used to identify voltage stability issues that limit the generator output power. All the formulation is developed by using the equivalent circuit of squirrel-cage induction machine. Simulation results are used to validate the method, which enables the approach to be used as a guide to reduce the simulation efforts necessary to assess the maximum output power and voltage stability of induction generators. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Synchronous distributed generators are prone to operate islanded after contingencies, which is usually not allowed due to safety and power-quality issues. Thus, there are several anti-islanding techniques; however, most of them present technical limitations so that they are likely to fail in certain situations. Therefore, it is important to quantify and determine whether the scheme under study is adequate or not. In this context, this paper proposes an index to evaluate the effectiveness of anti-islanding frequency-based relays commonly used to protect synchronous distributed generators. The method is based on the calculation of a numerical index that indicates the time period that the system is unprotected against islanding considering the global period of analysis. Although this index can precisely be calculated based on several electromagnetic transient simulations, a practical method is also proposed to calculate it directly from simple analytical formulas or lookup tables. The results have shown that the proposed approach can assist distribution engineers to assess and set anti-islanding protection schemes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background The application and better understanding of traditional and new breast tumor biomarkers and prognostic factors are increasing due to the fact that they are able to identify individuals at high risk of breast cancer, who may benefit from preventive interventions. Also, biomarkers can make possible for physicians to design an individualized treatment for each patient. Previous studies showed that trace elements (TEs) determined by X-Ray Fluorescence (XRF) techniques are found in significantly higher concentrations in neoplastic breast tissues (malignant and benign) when compared with normal tissues. The aim of this work was to evaluate the potential of TEs, determined by the use of the Energy Dispersive X-Ray Fluorescence (EDXRF) technique, as biomarkers and prognostic factors in breast cancer. Methods By using EDXRF, we determined Ca, Fe, Cu, and Zn trace elements concentrations in 106 samples of normal and breast cancer tissues. Cut-off values for each TE were determined through Receiver Operating Characteristic (ROC) analysis from the TEs distributions. These values were used to set the positive or negative expression. This expression was subsequently correlated with clinical prognostic factors through Fisher’s exact test and chi-square test. Kaplan Meier survival curves were also evaluated to assess the effect of the expression of TEs in the overall patient survival. Results Concentrations of TEs are higher in neoplastic tissues (malignant and benign) when compared with normal tissues. Results from ROC analysis showed that TEs can be considered a tumor biomarker because, after establishing a cut-off value, it was possible to classify different tissues as normal or neoplastic, as well as different types of cancer. The expression of TEs was found statistically correlated with age and menstrual status. The survival curves estimated by the Kaplan-Meier method showed that patients with positive expression for Cu presented a poor overall survival (p < 0.001). Conclusions This study suggests that TEs expression has a great potential of application as a tumor biomarker, once it was revealed to be an effective tool to distinguish different types of breast tissues and to identify the difference between malignant and benign tumors. The expressions of all TEs were found statistically correlated with well-known prognostic factors for breast cancer. The element copper also showed statistical correlation with overall survival.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We analyze the transport of heat along a chain of particles interacting through anharmonic potentials consisting of quartic terms in addition to harmonic quadratic terms and subject to heat reservoirs at its ends. Each particle is also subject to an impulsive shot noise with exponentially distributed waiting times whose effect is to change the sign of its velocity, thus conserving the energy of the chain. We show that the introduction of this energy conserving stochastic noise leads to Fourier's law. That is for large system size L the heat current J behaves as J ‘approximately’ 1/L, which amounts to say that the conductivity k is constant. The conductivity is related to the current by J = kΔT/L, where ΔT is the difference in the temperatures of the reservoirs. The behavior of heat conductivity k for small intensities¸ of the shot noise and large system sizes L are obtained by assuming a scaling behavior of the type k = ‘L POT a Psi’(L’lambda POT a/b’) where a and b are scaling exponents. For the pure harmonic case a = b = 1, characterizing a ballistic conduction of heat when the shot noise is absent. For the anharmonic case we found values for the exponents a and b smaller then 1 and thus consistent with a superdiffusive conduction of heat without the shot noise. We also show that the heat conductivity is not constant but is an increasing function of temperature.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In many countries buildings are responsible for a substantial part of the energy consumption, nd it varies according to their energetic and environmental performances. The potential for major reductions in buildings consumption have bee well documented in Brazil. Opportunities have been identified throughout the life cycle of the buildings, due of projects in diverse locations without the proper adjustments. This article offers a reflection about project processes and how its understanding can be conducted in an integrated way, favoring the use of natural resources and lowering energy consumption. It concludes by indicating that the longest phase in the life cycle of a building is also the phase responsible for its largest energy consumption, not only because of its duration but also for the interaction with the end user. Therefore, in order to harvest the energy cost reduction potential from future buildings designers need a holistic view of the surrounding, end users, materials and methodologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We derive lower bounds on the density of sources of ultra-high energy cosmic rays from the lack of significant clustering in the arrival directions of the highest energy events detected at the Pierre Auger Observatory. The density of uniformly distributed sources of equal intrinsic intensity was found to be larger than ~(0.06 - 5) × '10 POT. -4' 'Mpc POT. -3' at 95% CL, depending on the magnitude of the magnetic deflections. Similar bounds, in the range (0.2 - 7) × '10 POT. -4' 'Mpc POT. -3', were obtained for sources following the local matter distribution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research activity carried out during the PhD course in Electrical Engineering belongs to the branch of electric and electronic measurements. The main subject of the present thesis is a distributed measurement system to be installed in Medium Voltage power networks, as well as the method developed to analyze data acquired by the measurement system itself and to monitor power quality. In chapter 2 the increasing interest towards power quality in electrical systems is illustrated, by reporting the international research activity inherent to the problem and the relevant standards and guidelines emitted. The aspect of the quality of voltage provided by utilities and influenced by customers in the various points of a network came out only in recent years, in particular as a consequence of the energy market liberalization. Usually, the concept of quality of the delivered energy has been associated mostly to its continuity. Hence the reliability was the main characteristic to be ensured for power systems. Nowadays, the number and duration of interruptions are the “quality indicators” commonly perceived by most customers; for this reason, a short section is dedicated also to network reliability and its regulation. In this contest it should be noted that although the measurement system developed during the research activity belongs to the field of power quality evaluation systems, the information registered in real time by its remote stations can be used to improve the system reliability too. Given the vast scenario of power quality degrading phenomena that usually can occur in distribution networks, the study has been focused on electromagnetic transients affecting line voltages. The outcome of such a study has been the design and realization of a distributed measurement system which continuously monitor the phase signals in different points of a network, detect the occurrence of transients superposed to the fundamental steady state component and register the time of occurrence of such events. The data set is finally used to locate the source of the transient disturbance propagating along the network lines. Most of the oscillatory transients affecting line voltages are due to faults occurring in any point of the distribution system and have to be seen before protection equipment intervention. An important conclusion is that the method can improve the monitored network reliability, since the knowledge of the location of a fault allows the energy manager to reduce as much as possible both the area of the network to be disconnected for protection purposes and the time spent by technical staff to recover the abnormal condition and/or the damage. The part of the thesis presenting the results of such a study and activity is structured as follows: chapter 3 deals with the propagation of electromagnetic transients in power systems by defining characteristics and causes of the phenomena and briefly reporting the theory and approaches used to study transients propagation. Then the state of the art concerning methods to detect and locate faults in distribution networks is presented. Finally the attention is paid on the particular technique adopted for the same purpose during the thesis, and the methods developed on the basis of such approach. Chapter 4 reports the configuration of the distribution networks on which the fault location method has been applied by means of simulations as well as the results obtained case by case. In this way the performance featured by the location procedure firstly in ideal then in realistic operating conditions are tested. In chapter 5 the measurement system designed to implement the transients detection and fault location method is presented. The hardware belonging to the measurement chain of every acquisition channel in remote stations is described. Then, the global measurement system is characterized by considering the non ideal aspects of each device that can concur to the final combined uncertainty on the estimated position of the fault in the network under test. Finally, such parameter is computed according to the Guide to the Expression of Uncertainty in Measurements, by means of a numeric procedure. In the last chapter a device is described that has been designed and realized during the PhD activity aiming at substituting the commercial capacitive voltage divider belonging to the conditioning block of the measurement chain. Such a study has been carried out aiming at providing an alternative to the used transducer that could feature equivalent performance and lower cost. In this way, the economical impact of the investment associated to the whole measurement system would be significantly reduced, making the method application much more feasible.