970 resultados para Capa de disco


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Comunicação - FAAC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The quality and efficiency in straw cutting are determinants in the sowing process, according to the occurrence of "tamp" and stops, the magnitude of the straw removal or even the known effects of the seed "envelopment" where the cutting mechanism can not cut the remaining straw. Thus, the objective of this study was to evaluate the performance of different mechanisms for straw cutting of a seeder individualized in different amounts of crop coverage artificially added in a clay soil. The experiment was conducted at Unesp – Sao Paulo State University in the Experimental Farm Lageado, belonging to the College of Agricultural Sciences - Unesp, Botucatu. The experimental design was split plot with four replications, with main plots consisting of five quantities of black oat straw, in area with no-tillage system and subplots of three opening furrows mechanisms, which are: plane disk (PD), corrugated disk (CD) and wavy disk (WD). The wavy disk provided greater rolling resistance, reducing the speed of the set (tractor and equipment). The plane cutting disk showed the highest values of mobilized soil area, deeper penetration into the soil, requiring lower values of vertical force and higher values of lateral force. Regarding the type of waste and doses used, they offered no resistance to cutting and there was no change in the horizontal force on straw.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present work was to verify the behavior of yellow passion fruit, Afruvec variety, in relation to a population of Fusarium solani, obtained from this crop. The experimental delineation was random blocks, containing 10 treatments [9 isolates and 1 control treatment], with 4 repetitions, each plot being represented by a vase containing a plant. A disk of culture medium colonized by each isolate of the fungus was inoculated in the wounded collar region of the plants of the Afruvec variety two months after sowing. The appraised parameters were: the pathogenicity, the incidence (number of dead plants) and the severity of the disease (length of the lesion in the collar region), until 60 days after inoculation. The Afruvec variety was susceptible to the fungus and also presented variability as to the severity of the disease and incidence in relation to the different isolates. The population of the fungus showed variability in regard to aggressiveness. In light of the evidence of genetic diversity in the F. solani population, it is also suggested, in the tests of selection of materials to the pathogen, that these materials should be evaluated in different places with a history of the disease or inoculation with a pool of isolates of the fungus, in order to know the wide resistance of the genotype to the pathogen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Física - IFT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Machining is one of the most commonly manufacturing processes used in the modern world, consuming millions of dollars annually. Because of this, it is crucial for the automotive industry to reduce costs on their heat-resistant alloy machining processes, such as compacted graphite iron (CGI), which has shown an increasing trend of its application in diesel engine blocks, brakes disks, among other applications, due to its superior mechanical properties to gray cast iron. Despite this advantage, its use is still limited due to its difficulty of machining, moreover, cutting tools are displayed as the main factor in increasing the machining cost. Seeking an alternative to a better machinability of CGI, this paper aims to study two types of ceramic tools developed in Brazil, and benchmark their performance by dry turning. For this, were used CGI class 450 and two tools: ceramic of silicon nitride (Si3N4) and alumina-based (Al2O3), with a cutting speed (Vc) of 300, 400 and 500 m / min; feed (f) of 0.2 mm / rev and depth of cut (ap) of 0.5 mm, using three replicates and starting with new cutting edges. The results showed that the Al2O3 tool had the best performance in Vc of 500 m / min, while the Si3N4 tool had the best results in Vc of 300 m / min. This can be explained by the tool of Si3N4 based include soft intergranular phase, called amorphous, while alumina has higher abrasion resistance due to its high refractoriness. The results make it clear that the tools have significant potential for machining of compacted graphite iron, being necessary a strict control of the cutting parameters used

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Machining is one of the most commonly manufacturing processes used in the modern world, consuming millions of dollars annually. Because of this, it is crucial for the automotive industry to reduce costs on their heat-resistant alloy machining processes, such as compacted graphite iron (CGI), which has shown an increasing trend of its application in diesel engine blocks, brakes disks, among other applications, due to its superior mechanical properties to gray cast iron. Despite this advantage, its use is still limited due to its difficulty of machining, moreover, cutting tools are displayed as the main factor in increasing the machining cost. Seeking an alternative to a better machinability of CGI, this paper aims to study two types of ceramic tools developed in Brazil, and benchmark their performance by dry turning. For this, were used CGI class 450 and two tools: ceramic of silicon nitride (Si3N4) and alumina-based (Al2O3), with a cutting speed (Vc) of 300, 400 and 500 m / min; feed (f) of 0.2 mm / rev and depth of cut (ap) of 0.5 mm, using three replicates and starting with new cutting edges. The results showed that the Al2O3 tool had the best performance in Vc of 500 m / min, while the Si3N4 tool had the best results in Vc of 300 m / min. This can be explained by the tool of Si3N4 based include soft intergranular phase, called amorphous, while alumina has higher abrasion resistance due to its high refractoriness. The results make it clear that the tools have significant potential for machining of compacted graphite iron, being necessary a strict control of the cutting parameters used

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the retinal nerve fiber layer measurements with time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to test the diagnostic ability of both technologies in glaucomatous patients with asymmetric visual hemifield loss. Methods: 36 patients with primary open-angle glaucoma with visual field loss in one hemifield (affected) and absent loss in the other (non-affected), and 36 age-matched healthy controls had the study eye imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, California, USA) and 3 D OCT-1000 (Topcon, Tokyo, Japan). Peripapillary retinal nerve fiber layer measurements and normative classification were recorded. Total deviation values were averaged in each hemifield (hemifield mean deviation) for each subject. Visual field and retinal nerve fiber layer "asymmetry indexes" were calculated as the ratio between affected versus non-affected hemifields and corresponding hemiretinas. Results: Retinal nerve fiber layer measurements in non-affected hemifields (mean [SD] 87.0 [17.1] mu m and 84.3 [20.2] mu m, for TD and SD-OCT, respectively) were thinner than in controls (119.0 [12.2] mu m and 117.0 [17.7] mu m, P<0.001). The optical coherence tomography normative database classified 42% and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P=0.01). Retinal nerve fiber layer measurements were consistently thicker with TD compared to SD-OCT. Retinal nerve fiber layer thickness asymmetry index was similar in TD (0.76 [0.17]) and SD-OCT (0.79 [0.12]) and significantly greater than the visual field asymmetry index (0.36 [0.20], P<0.001). Conclusions: Normal hemifields of glaucoma patients had thinner retinal nerve fiber layer than healthy eyes, as measured by TD and SD-OCT. Retinal nerve fiber layer measurements were thicker with TD than SD-OCT. SD-OCT detected abnormal retinal nerve fiber layer thickness more often than TD-OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Determinar a reprodutibilidade da espessura da camada de fibras nervosas da retina peripapilar e dos parâmetros da cabeça do nervo óptico em olhos normais, utilizando a tomografia de coerência óptica de domínio espectral (SD-OCT). MÉTODOS: Trinta e quatro olhos de 34 indivíduos saudáveis foram incluídos no estudo. O protocolo do cubo do disco óptico 200x200 do OCT Cirrus foi utilizado para gerar 3 imagens de cada olho para avaliar a reprodutibilidade. O coeficiente de correlação intraclasse (ICC) foi calculado para as medidas da espessura da camada de fibras nervosas da retina e da cabeça do nervo óptico. RESULTADOS: A correlação foi excelente para todas as medidas da espessura da camada de fibras nervosas da retina (ICC entre 0,87 e 0,98). O mesmo ocorreu com os parâmetros da cabeça do nervo óptico que, com exceção da razão E/D vertical (ICC 0,56), apresentou ICC entre 0,83 e 0,99. CONCLUSÃO: As medidas de espessura da camada de fibras nervosas da retina peripapilar e os parâmetros da cabeça no nervo óptico demonstraram uma excelente reprodutibilidade com o OCT Cirrus, indicando que este aparelho poderá ser uma ferramenta útil no estudo do glaucoma. Este estudo apresenta algumas limitações, como o pequeno número de casos avaliados, sendo necessários maiores estudos para corroborar nossos achados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a eficácia do tratamento cirúrgico da mielorradiculopatia espondilótica cervical na produção de melhora neurológica pós-operatória, aferida em pontos pela escala da JOA e taxa de recuperação e as complicações do tratamento. MÉTODOS: Análise dos prontuários e os exames de imagem de 200 indivíduos submetidos a tratamento cirúrgico da mielorradiculopatia cervical no HC-FMUSP, no período de janeiro de 1993 a janeiro de 2007. A avaliação clínica foi quantificada pela escala da JOA, com média de segmento de 06 anos e 08 meses. RESULTADOS: Evidenciou-se melhora neurológica pós-operatória nas vias anterior e posterior, exceto nas laminectomias sem fusão, onde houve piora neurológica tardia. A via anterior mostrou um significante maior índice de complicações, relacionados a déficit de fusão intervertebral, deslocamento de enxerto, síndrome de disco adjacente, disfonia, disfagia, o mau posicionamento de enxerto e placas, lesão de raiz nervosa e significativo maior índice de re-intervenção cirúrgica. Na via posterior maior ocorrência de instabilidade em cifose pós-operatória na laminectomia, não sendo observada na laminoplastia, esta última com índices semelhantes aos encontrados na via anterior. Não houve melhora da dor axial nas laminoplastias e houve piora nas laminectomias, enquanto que nas discectomias e corpectomias houve significativa melhora do sintoma. CONCLUSÃO: As vias anterior e posterior foram eficazes em produzir melhora neurológica, exceto as laminectomias sem fusão. A via anterior produziu mais complicações, mas trata melhor a dor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O funcionamento fisiológico normal da coluna depende da movimentação normal de cada unidade motora, que consiste em duas vértebras e o disco intervertebral interposto entre elas. Embora a artrodese da coluna vertebral venha sendo utilizada para o tratamento de diversas doenças da coluna, essa modalidade de tratamento acarreta a perda de movimentação dos níveis em que houve a fusão e como consequência pode sobrecarregar os níveis adjacentes podendo provocar a sua degeneração precoce. Proponentes das técnicas de estabilização dinâmicas acreditam que estas podem levar a correção dos problemas minimizando o risco de degeneração dos níveis adjacentes. Atualmente existem no mercado diversos métodos de estabilização dinâmica anteriores e posteriores. Já existem trabalhos biomecânicos que comprovam o benefício teórico de quase todos eles, porém ainda hoje, faltam ensaios clínicos que comprovem a sua utilidade e segurança por longos períodos de seguimento para o paciente. Portanto é fundamental que estes materiais sejam analisados de maneira acadêmica para que no futuro próximo possam ser utilizados em situações precisas e com segurança para os pacientes.