847 resultados para C18 bonded silica gel
Resumo:
Coupling a liquid core waveguide cell to a sequential injection chromatograph improved the detection limits for determination of triazine herbicides without compromising peak resolution. Separation of simazine, atrazine, and propazine was achieved in water samples by a 25mm long C18 monolithic column. Detection was made at 238nm using a type II LCW (silica capillary coated with Teflon (R) AF2400) cell with 100cm of optical path length. Detection limits for simazine, atrazine, and propazine were 2.3, 1.9, and 4.5 mu g L-1, respectively. Reduced analysis time and low solvent consumption are other remarkable features of the proposed method.
Resumo:
Raman and IR experiments have been carried out on formamide (FA) and pyridine (Py) mixtures at different compositions. The appearance of a new Raman band at 996 cm(-1) (nu(1) region of Py), whose intensity depends on the FA concentration, is assigned to an FA: Py adduct and this result is in excellent agreement with those of other authors who employed noisy light-based coherent Raman scattering spectroscopy (I((2)) CARS). Another band at 1587 cm(-1) (nu(8) region of Py) has been observed for the first time by using Raman and IR spectroscopies. Its intensity shows the same dependence on the FA concentration and this fact allows us to also attribute it to an FA: Py adduct. The good relationship between the Raman and IR data demonstrates the potential of the vibrational spectroscopy for this kind of study. Owing to higher absolute Raman scattering cross section, the nu(1) region of Py has been chosen for the quantitative analysis and a stoichiometry of 1 : 1 FA: Py is reported. The experimental data are very well supported by the density functional theory (OFT) calculation, which was employed for the first time to the present system. Furthermore, the actual investigation shows an excellent agreement with those reported from computational calculations for similar systems. A comparison with our previous studies confirms that: the solvent dielectric constant determines the stoichiometry of a given Lewis acid-base adduct in the infinite dilution limit. Copyright (C) 2009 John Wiley & Sons, Ltd.
Resumo:
The development of efficient anti-corrosion and environmentally friendly coating systems are needed for the replacement of the highly toxic Cr-based conversion coatings for corrosion protection of aluminum alloys. In this study, we demonstrate that the direct application of ceramic cerium-based sol-gel coatings to AA7075-T6 substrates produces high-performance anti-corrosion layers. Electrochemical experiments and analyses of the microstructure demonstrate that the protective layers are very efficient for the passivation of the alloy surfaces operating as both passive and active barrier for corrosion protection.
Resumo:
Pectin is a natural polymer present in plants and, as all natural polymers has biodegradation properties. Chemically, pectin is a polysaccharide composed of a linear chain of 1 -> 4 linked galacturonic acids, which is esterified with methanol at 80%. The pectin-based gel electrolytes in a transparent film form were obtained by a plasticization process with glycerol and addition of LiClO(4). The films showed good ionic conductivity results, which increased from 10(-5) S/cm for the samples with 37 wt.% of glycerol to 4.7 x 10(-4) S/cm at room temperature for the sample with 68 wt.% of glycerol. The electrochemical behaviors of the samples were studied by electrochemical impedance spectroscopy (EIS), and Nyquist graphs are showed and discussed. The obtained pectin-based samples also presented good adherence to the glass, flexibility, homogeneity (SEM) and transparency (about 70% in the vis) properties. They are good candidates to be applied as gel electrolytes in electrochromic devices. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The search for more efficient anode catalyst than platinum to be used in direct alcohol fuel cell systems is an important challenge. In this study, boron-doped diamond film surfaces were modified with Pt, Pt-SnO(2) and Pt-Ta(2)O(5) nano-crystalline deposits by the sol-gel method to study the methanol and ethanol electro-oxidation reactions in acidic medium. Electrochemical experiments carried out in steady-state conditions demonstrate that the addition of SnO(2) to Pt produces a very reactive electrocatalyst that possibly adsorbs and/or dissociate ethanol more efficiently than pure Pt changing the onset potential of the reaction by 190 mV toward less positive potentials. Furthermore, the addition of Ta(2)O(5) to Pt enhances the catalytic activity toward the methanol oxidation resulting in a negative shift of the onset potential of 170 mV. These synergic effects indicate that the addition of these co-catalysts inhibits the poisoning effect caused by strongly adsorbed intermediary species. Since the SnO(2) catalyst was more efficient for ethanol oxidation, it could probably facilitate the cleavage of the C-C bond of the adsorbed intermediate fragments of the reaction. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
One of the key objectives in fuel-cell technology is to improve the performance of the anode catalyst for the alcohol oxidation and reduce Pt loading. Here, we show the use of six different electrocatalysts synthesized by the sol -gel method on carbon powder to promote the oxidation of methanol in acid media. The catalysts Pt-PbO(x) and Pt-(RuO(2)-PbO(x)) with 10% of catalyst load exhibited significantly enhanced catalytic activity toward the methanol oxidation reaction as compared to Pt-(RuO(2))/C and Pt/C electrodes. Cyclic voltammetry studies showed that the electrocatalysts Pt-PbO(x)/C and Pt-(RuO(2)-PbO(x))/C started the oxidation process at extremely low potentials and that they represent a good novelty to oxidize methanol. Furthermore, quasi-stationary polarization experiments and cronoamperometry studies showed the good performance of the Pt-PbO(x), Pt-(RuO(2)-PbO(x))/C and Pt-(RuO(2)-IrO(2))/C catalysts during the oxidation process. Thus, the addition of metallic Pt and PbO(x) onto high-area carbon powder, by the sol -gel route, constitutes an interesting way to prepare anodes with high catalytic activity for further applications in direct methanol fuel cell systems.
Resumo:
Objective To investigate if a home environment test battery can be used to measure effects of Parkinson’s disease (PD) treatment intervention and disease progression. Background Seventy-seven patients diagnosed with advanced PD were recruited in an open longitudinal 36-month study at 10 clinics in Sweden and Norway; 40 of them were treated with levodopa-carbidopa intestinal gel (LCIG) and 37 patients were candidates for switching from oral PD treatment to LCIG. They utilized a mobile device test battery, consisting of self-assessments of symptoms and objective measures of motor function through a set of fine motor tests (tapping and spiral drawings), in their homes. Both the LCIG-naïve and LCIG-non-naïve patients used the test battery four times per day during week-long test periods. Methods Assessments The LCIG-naïve patients used the test battery at baseline (before LCIG), month 0 (first visit; at least 3 months after intraduodenal LCIG), and thereafter quarterly for the first year and biannually for the second and third years. The LCIG-non-naïve patients used the test battery from the first visit, i.e. month 0. Out of the 77 patients, only 65 utilized the test battery; 35 were LCIG-non-naïve and 30 LCIG-naïve. In 20 of the LCIG-naïve patients, assessments with the test battery were available during oral treatment and at least one test period after having started infusion treatment. Three LCIG-naïve patients did not use the test battery at baseline but had at least one test period of assessments thereafter. Hence, n=23 in the LCIG-naïve group. In total, symptom assessments in the full sample (including both patient groups) were collected during 379 test periods and 10079 test occasions. For 369 of these test periods, clinical assessments including UPDRS and PDQ-39 were performed in afternoons at the start of the test periods. The repeated measurements of the test battery were processed and summarized into scores representing patients’ symptom severities over a test period, using statistical methods. Six conceptual dimensions were defined; four subjectively-reported: ‘walking’, ‘satisfied’, ‘dyskinesia’, and ‘off’ and two objectively-measured: ‘tapping’ and ‘spiral’. In addition, an ‘overall test score’ (OTS) was defined to represent the global health condition of the patient during a test period. Statistical methods Change in the test battery scores over time, that is at baseline and follow-up test periods, was assessed with linear mixed-effects models with patient ID as a random effect and test period as a fixed effect of interest. The within-patient variability of OTS was assessed using intra-class correlation coefficient (ICC), for the two patient groups. Correlations between clinical rating scores and test battery scores were assessed using Spearman’s rank correlations (rho). Results In LCIG-naïve patients, mean OTS compared to baseline was significantly improved from the first test period on LCIG treatment until month 24. However, there were no significant changes in mean OTS scores of LCIG-non-naïve patients, except for worse mean OTS at month 36 (p<0.01, n=16). The mean scores of all subjectively-reported dimensions improved significantly throughout the course of the study, except ‘walking’ at month 36 (p=0.41, n=4). However, there were no significant differences in mean scores of objectively-measured dimensions between baseline and other test periods, except improved ‘tapping’ at month 6 and month 36, and ‘spiral’ at month 3 (p<0.05). The LCIG-naïve patients had a higher within-subject variability in their OTS scores (ICC=0.67) compared to LCIG-non-naïve patients (ICC=0.71). The OTS correlated adequately with total UPDRS (rho=0.59) and total PDQ-39 (rho=0.59). Conclusions In this 3-year follow-up study of advanced PD patients treated with LCIG we found that it is possible to monitor PD progression over time using a home environment test battery. The significant improvements in the mean OTS scores indicate that the test battery is able to measure functional improvement with LCIG sustained over at least 24 months.