954 resultados para Blunt chest trauma
Resumo:
OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.
Resumo:
We present a rare case of pulmonary intimal sarcoma mimicking pulmonary embolism in a 40-year-old woman. Although extremely rare, these tumors must be considered in patients who present inappropriate imaging findings that suggest embolism. Chest computed tomography is the modality of choice to determine the extent of the tumor. We present a female patient with suspected embolism that was in fact found to be an endothelial sarcoma of the pulmonary arteries.
Resumo:
OBJECTIVE The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. MATERIALS AND METHODS We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. RESULTS A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1% ± 2.2% versus 85.6% ± 5.6% (p = 0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7% ± 8.1% (with bone suppression, 46.1% ± 8%; p = 0.94); for microdose CT, nodule sensitivity was 83.6% ± 9% without MIP (with additional MIP, 92.5% ± 6%; p < 10(-3)). Individual sensitivities of microdose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (p < 10(-6)). The effective dose for chest radiography including dual-energy subtraction was 0.242 mSv; for microdose CT, the applied dose was 0.1323 mSv. CONCLUSION Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.
Resumo:
Objective: Chronic depression has often been associated with childhood trauma. There may, however, be an interaction between personality pathology, childhood trauma, and chronic depression. This interaction has not yet been studied. Method: This retrospective analysis is based on 279 patients contacted for a randomized trial in an outpatient psychotherapy center over a period of 18 months from 2010 to 2012. Current diagnoses of a personality disorder and presence of chronic depression were systematically assessed using the Structured Clinical Interview for DSM-IV. Retrospective reports of childhood trauma were collected using the short form of the Childhood Trauma Questionnaire (CTQ-SF). DSM-IV–defined chronic depression was the primary outcome. The association between chronic depression, childhood trauma, and personality disorders was analyzed using correlations. Variables that had at least a small effect on correlation analysis were entered into a series of logistic regression analyses to determine the predictors of chronic depression and the moderating effect of childhood trauma. Results: The presence of avoidant personality disorder, but no CTQ-SF scale, was associated with the chronicity of depression (odds ratio [OR] = 2.20, P = .015). The emotional abuse subscale of the CTQ-SF did, however, correlate with avoidant personality disorder (OR = 1.15, P = .000). The level of emotional abuse had a moderating effect on the effect of avoidant personality disorder on the presence of chronic depression (OR = 1.08, P = .004). Patients who did not suffer from avoidant personality disorder had a decreased rate of chronic depression if they retrospectively reported more severe levels of emotional abuse (18.9% vs 39.7%, respectively). Conclusions: The presence of avoidant personality pathology may interact with the effect of childhood trauma in the development of chronic depression. This has to be confirmed in a prospective study.
Resumo:
BACKGROUND The assessment of hemodynamic status is a crucial task in the initial evaluation of trauma patients. However, blood pressure and heart rate are often misleading, as multiple variables may impact these conventional parameters. More reliable methods such as pulmonary artery thermodilution for cardiac output measuring would be necessary, but its applicability in the Emergency Department is questionable due to their invasive nature. Non-invasive cardiac output monitoring devices may be a feasible alternative. METHODS A systematic literature review was conducted. Only studies that explicitly investigated non-invasive hemodynamic monitoring devices in trauma patients were considered. RESULTS A total of 7 studies were identified as suitable and were included into this review. These studies evaluated in a total of 1,197 trauma patients the accuracy of non-invasive hemodynamic monitoring devices by comparing measurements to pulmonary artery thermodilution, which is the gold standard for cardiac output measuring. The correlation coefficients r between the two methods ranged from 0.79 to 0.92. Bias and precision analysis ranged from -0.02 +/- 0.78 l/min/m(2) to -0.14 +/- 0.73 l/min/m(2). Additionally, data on practicality, limitations and clinical impact of the devices were collected. CONCLUSION The accuracy of non-invasive cardiac output monitoring devices in trauma patients is broadly satisfactory. As the devices can be applied very early in the shock room or even preclinically, hemodynamic shock may be recognized much earlier and therapeutic interventions could be applied more rapidly and more adequately. The devices can be used in the daily routine of a busy ED, as they are non-invasive and easy to master.
Resumo:
Childhood traumatic events may lead to long-lasting psychological effects and contribute to the development of complex posttraumatic sequelae. These might be captured by the diagnostic concept of complex posttraumatic stress disorder (CPTSD) as an alternative to classic posttraumatic stress disorder (PTSD). CPTSD comprises a further set of symptoms in addition to those of PTSD, namely, changes in affect, self, and interpersonal relationships. Previous empirical research on CPTSD has focused on middle-aged adults but not on older adults. Moreover, predictor models of CPTSD are still rare. The current study investigated the association between traumatic events in childhood and complex posttraumatic stress symptoms in older adults. The mediation of this association by 2 social-interpersonal factors (social acknowledgment as a survivor and dysfunctional disclosure) was investigated. These 2 factors focus on the perception of acknowledgment by others and either the inability to disclose traumatic experiences or the ability to do so only with negative emotional reactions. A total of 116 older individuals (age range = 59–98 years) who had experienced childhood traumatic events completed standardized self-report questionnaires indexing childhood trauma, complex trauma sequelae, social acknowledgment, and dysfunctional disclosure of trauma. The results showed that traumatic events during childhood were associated with later posttraumatic stress symptoms but with classic rather than complex symptoms. Social acknowledgment and dysfunctional disclosure partially mediated this relationship. These findings suggest that childhood traumatic stress impacts individuals across the life span and may be associated with particular adverse psychopathological consequences.
Resumo:
A common form of violence investigated in legal medicine is blunt trauma caused by striking with different objects. The injuries and medical consequences have been widely examined, whereas the forces and especially the energies acting on impact have rarely been analyzed. This study focuses on how the impact energy of different striking objects depends on their characteristics. A total of 1170 measurements of horizontal strikes against a static and relatively heavy pendulum have been acquired with 13 volunteers. The main focus was laid on how the weight, the length, and the center of mass of the different striking objects influenced the striking energy. The results show average impact energies in the range of 67.3 up to 311.5 J for men with an optimum weight of about 1.3 kg with its center of mass in the far end quarter for a 1-m-long striking object. The average values for women range from 30 to 202.6 J, with an optimum weight between 1.65 and 2.2 kg and similar settings for the center of mass as the men. Also, the impact energies are getting higher with shorter object lengths and reach a maximum at a length of about 0.3 to 0.4 m. The male volunteers' impact energy was on average by 84.2 % higher than the values of the female volunteers, where the impact masses were very similar and the impact velocities played the key role.
Resumo:
OBJECTIVE Abnormal ECG findings suggestive of cardiac disease are frequent in patients with funnel chest, although structural heart disease is rare. Electrocardiographic characteristics and changes following new surgical treatments in young adults are not described so far. The aim of the study was to analyze electrocardiographic characteristics of patients with funnel chest before and after minimally invasive funnel chest correction by the Nuss procedure. METHODS Twenty-six patients with surgical correction of funnel chest using pectus bar were included. Twelve-lead ECGs before and later than one year after surgery were analyzed. RESULTS In postoperative ECGs, amplitude of P wave in lead II and negative terminal amplitude of P wave in lead V1 decreased from 0.13 to 0.10mV (p=0.03), and from 0.10 to 0.04mV (p<0.001), respectively. Mean QRS duration decreased from 108ms to 98ms (p=0.003) after correction. A pathological left and right Sokolow-Lyon index was observed in 35% and 23% of patients before, versus 8% (p=0.04) and 0% (p=0.01) after correction, respectively. In contrast, the rate of patients with J wave pattern in precordial leads V4-V6 increased from 8% before to 42% after surgery (p=0.004). CONCLUSIONS ECG abnormalities in patients with funnel chest are frequent, and can normalize after surgical correction by the Nuss procedure. De novo J wave pattern in precordial leads V4-V6 is a frequent finding after surgical funnel chest correction using pectus bar.
Resumo:
Traumatic experiences may affect an individual's ability to exercise self-control, which is an essential characteristic for successfully managing life. As a measure of self-control, we used the delay discounting paradigm, that is, the extent to which a person devalues delayed gratification. The aim of this study was to investigate the relationship between childhood trauma and delay discounting using a control group design with elderly participants with a mean age of 76.2 years. Swiss former indentured child laborers (n=103) who had been exposed to trauma during their childhood were compared with nontraumatized controls (n=50). The trauma exposure group showed a considerably higher preference for immediate smaller rewards than the controls, indicating their lower self-control. A hierarchical regression analysis revealed that a history of abuse, current self-efficacy, and education were significantly associated with delay discounting. Implications for future research are discussed.