912 resultados para BEAM EQUATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the influence of individual factors on differences in bone mineral density (BMD) using dual X-ray absorptiometry pencil beam (PB) and fan beam (FB) modes in vivo and in vitro. PB.BMD and FB.BMD of 63 normal Caucasian females ages 21-80 yr were measured at the lumbar spine and hip. Residuals of the FB/PB regression were used to assess the impact of height, weight, adiposity index (AI) (= weight/height(3/2)), back tissue thickness, and PB.BMD, respectively, on FB/PB difference. The Hologic Anthropomorphic Spine Phantom (ASP) was measured using the PB and FB modes at two different levels to assess the impact of scanning mode and focus distance. The European Spine Phantom (ESP) prototype, a geometrically well-defined phantom with known vertebral densities, was measured using PB and FB modes and analyzed manually to determine the impact of bone density on FB/PB difference and automatically to determine the impact of edge detection on FB/PB difference. Population BMD results were perfectly correlated, but significantly overestimated by 1.5% at the lumbar spine and underestimated by 0.7% at the neck, 1.8% at the trochanter, and 2.0% at the total hip, respectively, when using the FB compared with PB mode. At the lumbar spine, the FB/PB residual correlated negatively with height (r = 0.34, p < 0.01) and PB.BMD (r = 0.48, p <: 0. 0001) and positively with AI (r = 0.26, p < 0.05). At the hip, residual of trochanter correlated positively with weight (r = 0.36, p < 0.01) and AI (r = 0.36, p < 0.01). The FB mode significantly increased ASP BMD by 0.7% compared with PB. Using the FB mode, increasing focus distance significantly (p < 0.001) decreased area and bone mineral content, but not BMD. By contrast, increasing focus distance significantly decreased PB.BMD by 0.7%. With the ESP, the PB mode supplied accurate projected are of the bone (AREA) results but significant underestimation of specified BMD in the manual analysis. The FB mode significantly underestimated PB. AREA by 2.9% but fitted specified BMD quite well. FB/PB overestimation was larger for the low-density (+8.7%) than for the high-density vertebra (+4. 9%). The automated analysis resulted in more than 14% underestimation of PB. AREA (low-density vertebra) and an almost 13% overestimation of PB.BMD (high-density vertebra) using FB. In conclusion, FB and PB measurements are highly correlated at the lumbar spine and hip with small but significant BMD differences related to height, adiposity, and BMD. In clinical practice, it can be erroneous to switch from one method to another, especially in women with low bone density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The purpose of the present study was to evaluate the thickness and anatomic characteristics of the sinus membrane using cone beam computed tomography (CBCT) in patients evaluated for implant surgery in the posterior maxilla. MATERIALS AND METHODS The study included 131 consecutive patients referred for dental implant placement in the posterior maxilla. A total of 138 CBCT images was obtained using fields of view of 4 × 4 cm, 6 × 6 cm, or 8 × 8 cm. Reformatted sagittal CBCT slices were analyzed with regard to the thickness and characteristics of the sinus membrane at single-tooth gaps in the posterior maxilla. Factors that might influence the dimensions of the sinus membrane, such as age, sex, endodontic status, and the season, were analyzed. RESULTS The mean thickness of the maxillary sinus mucosa varied between 2.1 and 2.69 mm in the three locations analyzed. Fewer than half of the evaluated sinuses exhibited a healthy mucosa (49 of 138, or 35.51%). Most of the pathologic findings were flat, shallow thickenings (63 of 138, or 45.65%). Sex did not influence the thickness of the sinus membrane at the root tips of the premolars or at single-tooth gaps, but there was a statistically significant correlation in the region of the maxillary molars. No other evaluated factors had a statistically significant effect on the dimensions of the antral mucosa. CONCLUSIONS In the present study, sex was the only factor influencing the dimension of the sinus membrane, whereas patient age, season, and the endodontic status of neighboring teeth had no significant effect on the thickness of the antral mucosa. Future studies should address which types of mucosal thickening require interdisciplinary therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Delivering cochlear implants through a minimally invasive tunnel (1.8 mm in diameter) from the mastoid surface to the inner ear is referred to as direct cochlear access (DCA). Based on cone beam as well as micro-computed tomography imaging, this in vitro study evaluates the feasibility and efficacy of manual cochlear electrode array insertions via DCA. Free-fitting electrode arrays were inserted in 8 temporal bone specimens with previously drilled DCA tunnels. The insertion depth angle, procedural time, tunnel alignment as well as the inserted scala and intracochlear trauma were assessed. Seven of the 8 insertions were full insertions, with insertion depth angles higher than 520°. Three cases of atraumatic scala tympani insertion, 3 cases of probable basilar membrane rupture and 1 case of dislocation into the scala vestibuli were observed (1 specimen was damaged during extraction). Manual electrode array insertion following a DCA procedure seems to be feasible and safe and is a further step toward clinical application of image-guided otological microsurgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study analyses the location of impacted maxillary canines and factors influencing root resorptions of adjacent teeth using cone-beam computed tomography (CBCT). In addition, the interrater reliability between observers of two different dental specialties for radiographic parameters will be evaluated. CBCT images of patients who were referred for radiographic localization of impacted maxillary canines and/or suspicion of root resorptions of adjacent teeth were included. The study analysed the exact three-dimensional location of the impacted canines in the anterior maxilla, frequency and extent of root resorptions, and potential influencing factors. To assess interrater agreement, Cohen's correlation parameters were calculated. This study comprises 113 patients with CBCT scans, and 134 impacted canines were analysed retrospectively. In the patients evaluated, 69 impacted canines were located palatally (51.49 per cent), 41 labially (30.60 per cent), and 24 (17.91 per cent) in the middle of the alveolar process. Root resorptions were found in 34 lateral incisors (25.37 per cent), 7 central incisors (5.22 per cent), 6 first premolars (4.48 per cent), and 1 second premolar (0.75 per cent). There was a significant correlation between root resorptions on adjacent teeth and localization of the impacted canine in relation to the bone, as well as vertical localization of the canine. Interrater agreement showed values of 0.546-0.877. CBCT provides accurate information about location of the impacted canine and prevalence and degree of root resorption of neighbouring teeth with high interrater correlation. This information is of great importance for surgeons and orthodontists for accurate diagnostics and interdisciplinary treatment planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The aims of this study were to compare lateral cephalograms with other radiologic methods for diagnosing suspected fusions of the cervical spine and to validate the assessment of congenital fusions and osteoarthritic changes against the anatomic truth. METHODS Four cadaver heads were selected with fusion of vertebrae C2 and C3 seen on a lateral cephalogram. Multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) were performed and assessed by 5 general radiologists and 5 oral radiologists, respectively. Vertebrae C2 and C3 were examined for osseous fusions, and the left and right facet joints were diagnosed for osteoarthritis. Subsequently, the C2 and C3 were macerated and appraised by a pathologist. Descriptive analysis was performed, and interrater agreements between and within the groups were computed. RESULTS All macerated specimens showed osteoarthritic findings of varying degrees, but no congenital bony fusion. All observers agreed that no fusion was found on MDCT or CBCT. They disagreed on the prevalence of osteoarthritic deformities (general radiologists/MDCT, 100%; oral radiologists/CBCT, 93.3%) and joint space assessment in the facet joints (kappa = 0.452). The agreement within the rater groups differed considerably (general radiologists/MDCT, kappa = 0.612; oral radiologists/CBCT, kappa = 0.240). CONCLUSIONS Lateral cephalograms do not provide dependable data to assess the cervical spine for fusions and cause false-positive detections. Both MDCT interpreted by general radiologists and CBCT interpreted by oral radiologists are reliable methods to exclude potential fusions. Degenerative osteoarthritic changes are diagnosed more accurately and consistently by general radiologists evaluating MDCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION The mental foramen (MF) is an important landmark in dentistry. Knowledge of its position is central to perform block anesthesia of the mental nerve or to avoid nerve damage during surgical procedures in the premolar area of the mandible. The present radiographic study aimed at evaluating the location and dimension of the MF and measuring distances to neighboring structures by using limited cone-beam computed tomography (CBCT). METHODS Sagittal, axial, and coronal CBCT images of 142 patients (26 bilateral and 116 unilateral cases) were retrospectively screened to determine the location of the MF with respect to adjacent teeth and to take linear measurements of the size of the MF and its distances to the upper and lower borders of the mandible. In addition, the course and angulation of the mental canal exiting the MF were assessed. RESULTS The majority of MF (56%) were located apically between the 2 premolars, and another 35.7% of MF were positioned below the second premolar. On average, the MF was localized 5.0 mm from the closest root of the adjacent tooth (range, 0.3-9.8 mm). The mean size of the MF showed a height of 3.0 mm and a length of 3.2 mm; however, individual cases showed large differences in height (1.8-5.1 mm) and in length (1.8-5.5 mm). All mental canals exiting the MF demonstrated an upward course in the coronal plane, with 70.1% of the mental canal presenting an anterior loop (AL) in the axial view. The mean extension of AL in cases with an AL was 2.3 mm. CONCLUSIONS This study is consistent with previous radiographic studies regarding size and location of MF and distances between MF and adjacent anatomic structures. The assessed bilateral cases showed a high intraindividual concordance for certain features when comparing right and left sides.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the introduction of cone beam computed tomography (CBCT), this 3-dimensional diagnostic imaging technique has been established in a growing number of fields in dental medicine. It has become an important tool for both diagnosis and treatment planning, and is also able to support endodontic treatments. However, the higher effective dose of ionizing radiation compared to conventional 2-dimensional radiographs is not justifiable in every case. CBCT allows for a more precise diagnosis of periapical lesions, root fractures as well as external and internal resorptions. Concerning the utility of CBCT in treatment planning decisions, the gain of information through 3-dimensional imaging for any of these pathologies has to be evaluated carefully on an individual basis. Moreover, radioopaque materials such as root canal filling and posts often create artefacts, which may compromise diagnosis. The aim of this review is to summarize the possibilities and limits of CBCT imaging in endodontology as well as introduce guidelines for daily clinical practice. Furthermore, the article presents possible therapeutic advantages of preexisting CBCT scans for root canal treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The anterior maxilla, sometimes also called premaxilla, is an area frequently requiring surgical interventions. The objective of this observational study was to identify and assess accessory bone channels other than the nasopalatine canal in the anterior maxilla using limited cone beam computed tomography (CBCT). METHODS A total of 176 cases fulfilled the inclusion criteria comprising region of interest, quality of CBCT image, and absence of pathologic lesions or retained teeth. Any bone canal with a minimum diameter of 1.00 mm other than the nasopalatine canal was analyzed regarding size, location, and course, as well as patient gender and age. RESULTS A total of 67 accessory canals ≥1.00 mm were found in 49 patients (27.8%). A higher frequency of accessory canals was observed in males (33.0%) than in females (22.7%) (p = 0.130). Accessory canals occurred more frequently in older rather than younger patients (p = 0.115). The mean diameter of accessory canals was 1.31 ± 0.26 mm (range 1.01-2.13 mm). Gender and age did not significantly influence the diameter. Accessory canals were found palatal to all anterior teeth, but most frequently palatal to the central incisors. In 56.7%, the accessory canals curved superolaterally and communicated with the ipsilateral alveolar extension of the canalis sinuosus. CONCLUSIONS The study confirms the presence of bone channels within the anterior maxilla other than the nasopalatine canal. More than half of these accessory bone canals communicated with the canalis sinuosus. From a clinical perspective, studies are needed to determine the content of these accessory canals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study investigated the association between individual differences in sociosexual orientation and four aspects of body image in 156 male and 136 female students. While men were characterized by a less restricted sociosexual orientation, higher self-perceived physical attractiveness, and more pronounced self-rated physical assertiveness, women placed more emphasis on accentuation of body presentation. Structural equation modeling revealed significant positive relationships between sociosexual attitudes and physical attractiveness and accentuation of body presentation as well as between sociosexual behavior and physical attractiveness for the total sample. When introducing sex as a grouping variable, the attitudinal and behavioral components of sociosexuality were reliably related to both physical attractiveness and accentuation of body presentation as two aspects of body image in men, but not in women. Furthermore, our findings suggest that accentuation of body presentation represents a goal-directed behavior in men to increase the likelihood of having uncommitted sex but serves additional functions widely unrelated to unrestrictive sociosexual behavior in women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last century, several mathematical models have been developed to calculate blood ethanol concentrations (BAC) from the amount of ingested ethanol and vice versa. The most common one in the field of forensic sciences is Widmark's equation. A drinking experiment with 10 voluntary test persons was performed with a target BAC of 1.2 g/kg estimated using Widmark's equation as well as Watson's factor. The ethanol concentrations in the blood were measured using headspace gas chromatography/flame ionization and additionally with an alcohol Dehydrogenase (ADH)-based method. In a healthy 75-year-old man a distinct discrepancy between the intended and the determined blood ethanol concentration was observed. A blood ethanol concentration of 1.83 g/kg was measured and the man showed signs of intoxication. A possible explanation for the discrepancy is a reduction of the total body water content in older people. The incident showed that caution is advised when using the different mathematical models in aged people. When estimating ethanol concentrations, caution is recommended with calculated results due to potential discrepancies between mathematical models and biological systems

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Species coexistence has been a fundamental issue to understand ecosystem functioning since the beginnings of ecology as a science. The search of a reliable and all-encompassing explanation for this issue has become a complex goal with several apparently opposing trends. On the other side, seemingly unconnected with species coexistence, an ecological state equation based on the inverse correlation between an indicator of dispersal that fits gamma distribution and species diversity has been recently developed. This article explores two factors, whose effects are inconspicuous in such an equation at the first sight, that are used to develop an alternative general theoretical background in order to provide a better understanding of species coexistence. Our main outcomes are: (i) the fit of dispersal and diversity values to gamma distribution is an important factor that promotes species coexistence mainly due to the right-skewed character of gamma distribution; (ii) the opposite correlation between species diversity and dispersal implies that any increase of diversity is equivalent to a route of “ecological cooling” whose maximum limit should be constrained by the influence of the third law of thermodynamics; this is in agreement with the well-known asymptotic trend of diversity values in space and time; (iii) there are plausible empirical and theoretical ways to apply physical principles to explain important ecological processes; (iv) the gap between theoretical and empirical ecology in those cases where species diversity is paradoxically high could be narrowed by a wave model of species coexistence based on the concurrency of local equilibrium states. In such a model, competitive exclusion has a limited but indispensable role in harmonious coexistence with functional redundancy. We analyze several literature references as well as ecological and evolutionary examples that support our approach, reinforcing the meaning equivalence between important physical and ecological principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Images from computed tomography (CT), combined with navigation systems, improve the outcomes of local thermal therapies that are dependent on accurate probe placement. Although the usage of CT is desired, its availability for time-consuming radiological interventions is limited. Alternatively, three-dimensional images from C-arm cone-beam CT (CBCT) can be used. The goal of this study was to evaluate the accuracy of navigated CBCT-guided needle punctures, controlled with CT scans. METHODS Five series of five navigated punctures were performed on a nonrigid phantom using a liver specific navigation system and CBCT volumetric dataset for planning and navigation. To mimic targets, five titanium screws were fixed to the phantom. Target positioning accuracy (TPECBCT) was computed from control CT scans and divided into lateral and longitudinal components. Additionally, CBCT-CT guidance accuracy was deducted by performing CBCT-to-CT image coregistration and measuring TPECBCT-CT from fused datasets. Image coregistration was evaluated using fiducial registration error (FRECBCT-CT) and target registration error (TRECBCT-CT). RESULTS Positioning accuracies in lateral directions pertaining to CBCT (TPECBCT = 2.1 ± 1.0 mm) were found to be better to those achieved from previous study using CT (TPECT = 2.3 ± 1.3 mm). Image coregistration error was 0.3 ± 0.1 mm, resulting in an average TRE of 2.1 ± 0.7 mm (N = 5 targets) and average Euclidean TPECBCT-CT of 3.1 ± 1.3 mm. CONCLUSIONS Stereotactic needle punctures might be planned and performed on volumetric CBCT images and controlled with multidetector CT with positioning accuracy higher or similar to those performed using CT scanners.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A first result of the search for ν ( )μ( ) → ν ( )e( ) oscillations in the OPERA experiment, located at the Gran Sasso Underground Laboratory, is presented. The experiment looked for the appearance of ν ( )e( ) in the CNGS neutrino beam using the data collected in 2008 and 2009. Data are compatible with the non-oscillation hypothesis in the three-flavour mixing model. A further analysis of the same data constrains the non-standard oscillation parameters θ (new) and suggested by the LSND and MiniBooNE experiments. For large values (>0.1 eV(2)), the OPERA 90% C.L. upper limit on sin(2)(2θ (new)) based on a Bayesian statistical method reaches the value 7.2 × 10(−3).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The T2K collaboration reports a precision measurement of muon neutrino disappearance with an off-axis neutrino beam with a peak energy of 0.6 GeV. Near detector measurements are used to constrain the neutrino flux and cross section parameters. The Super-Kamiokande far detector, which is 295 km downstream of the neutrino production target, collected data corresponding to 3.01×1020 protons on target. In the absence of neutrino oscillations, 205±17 (syst.) events are expected to be detected and only 58 muon neutrino event candidates are observed. A fit to the neutrino rate and energy spectrum assuming three neutrino flavors, normal mass hierarchy and θ23≤π/4 yields a best-fit mixing angle sin2(2θ23)=1.000 and mass splitting |Δm232|=2.44×10−3 eV2/c4. If θ23≥π/4 is assumed, the best-fit mixing angle changes to sin2(2θ23)=0.999 and the mass splitting remains unchanged.