961 resultados para user experience measurement
Resumo:
Dissertação de mestrado em Ciências da Comunicação (área de especialização em Audiovisual e Multimédia)
Resumo:
OBJECTIVE: To assess by Doppler echocardiography the structural and functional alterations of rat heart with surgical induced extensive myocardial infarction. METHODS: Five weeks after surgical ligature of the left coronary artery, 38 Wistar-EPM rats of both sexes, 10 of them with extensive infarction, undergone anatomical and functional evaluation by Doppler echocardiography and then euthanized for anatomopathological analysis. RESULTS: Echocardiography was 100% sensible and specific to anatomopathological confirmed extensive miocardial infarction. Extensive infarction lead to dilatation of left ventricle (diastolic diameter: 0.89cm vs.0.64cm; systolic: 0.72cm vs. 0.33cm) and left atrium (0.55cm vs. 0.33cm); thinning of left ventricular anterior wall (systolic: 0.14cm vs. 0.23cm, diastolic: 0.11cm vs. 0.14cm); increased mitral E/ A wave relation (6.45 vs. 1.95). Signals of increased end diastolic ventricle pressure, B point in mitral valve tracing in 62.5% and signs of pulmonary hypertension straightening of pulmonary valve (90%) and notching of pulmonary systolic flow (60%) were observed in animals with extensive infarction. CONCLUSION: Doppler echocardiography has a high sensitivity and specificity for detection of chronic extensive infarction. Extensive infarction caused dilatation of left cardiac chambers and showed in Doppler signals of increased end diastolic left ventricular pressure and pulmonary artery pressure.
Resumo:
Dissertação de mestrado em Direito Administrativo
Resumo:
After the incorporation of automated external defibrilators by other airlines and the support of the Brazilian Society of cardiology, Varig Airlines Began the onboard defibrilation program with the initial purpose of equiping wide-body aircrafts frequently used in international flights and that airplanes use in the Rio - São Paulo route. With all fight attendants trained, the automated. External defibrilation devides were incorporated to 34 airplanes of a total pleet of 80 aircrats. The devices were intalled in the bagage compartments secured with velero straps and 2 pairs of electrods, one or which pre-conected to the device to minimize application time. Later, a portable monitor was addres to the ressocitation kit in the long flights. The expansion of the knowledge of the basic life support fundamentors and the correted implantation of the survival chain and of the automated external defibrilators will increase the extense of recovery of cardiorespiratory arrest victins in aircrafts.
Resumo:
OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.
Resumo:
Intracoronary brachytherapy using beta or gamma radiation is currently the most efficient type of therapy for preventing the recurrence of coronary in-stent restenosis. Its implementation depends on the interaction among interventionists, radiotherapists, and physicists to assure the safety and quality of the method. The authors report the pioneering experience in Brazil of the treatment of 2 patients with coronary in-stent restenosis, in whom beta radiation was used as part of the international multicenter randomized PREVENT study (Proliferation REduction with Vascular ENergy Trial). The procedures were performed rapidly and did not require significant modifications in the traditional techniques used for conventional angioplasty. Alteration in the radiological protection devices of the hemodynamic laboratory were also not required, showing that intracoronary brachytherapy using beta radiation can be incorporated into the interventional tools of cardiology in our environment.
Resumo:
OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years), and the median weight was 14kg (from 6 to 92kg). Sixteen patients (48.5%) were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0±1.0, median of 3.9). The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4±3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
Aims. This paper is a report on a study analysing the effect of the umbilical cord cutting experience on fathers’ emotional involvement with their infants. Background. Participation in childbirth offers an opportunity for father and mother to share the childbirth experience, so it is vital that midwives improve the fathers’ participation in this event. Design. A quasi-experimental study with a quantitative methodology was implemented. Methods. One hundred and five fathers were recruited as part of a convenience sample in a Maternity Public Hospital in a Metropolitan City in Portugal, between January and May of 2008. The Bonding Scale, the Portuguese version of the ‘Mother-to-Infant Bonding Scale’ was used to evaluate the fathers’ emotional involvement with the neonate at different moments: before childbirth, first day after childbirth and first month after childbirth. After childbirth, the fathers were divided into three separate groups depending on their umbilical cord cutting experience. Results. The results demonstrate that the emotional involvement between father and child tends to increase during the first days after childbirth and to decrease when evaluated 1 month after birth, for fathers who did not cut the umbilical cord. However, fathers who cut the umbilical cord demonstrate an improvement in emotional involvement 1 month later. Conclusion. Results suggest that the umbilical cord cutting experience benefits the father’s emotional involvement with the neonate, supporting the benefits of his participation and empowerment in childbirth.
Resumo:
OBJECTIVE - To describe clinical observations of marked improvement in ventricular dysfunction in a medical office environment under circumstances differing from those in study protocols and multicenter studies performed in hospital or with outpatient cohorts. METHODS - Eleven cardiac failure patients with marked ventricular dysfunction receiving treatment at a doctors office between 1994 and 1999 were studied. Their ages ranged from 20 and 66 years (mean 39.42±14.05 years); 7 patients were men, 4 were women. Cardiopathic etiologies were arterial hypertension in 5 patients, peripartum cardiomyopathy in 2, nondefined myocarditis in 2, and alcoholic cardiomyopathy in 4. Initial echocardiograms revealed left ventricular dilatation (average diastolic diameter, 69.45±8.15mm), reduced left ventricular ejection fraction (0.38±0.08) and left atrial dilatation (43.36±5.16mm). The therapeutic approach followed consisted of patient orientation, elimination of etiological or causal factors of cardiac failure, and prescription of digitalis, diuretics, and angiotensinconverting enzyme inhibitors. RESULTS - Following treatment, left ventricular ejection fraction changed to 0.63±0.09; left ventricular diameters changed to 57.18±8.13mm, and left atrium diameters changed to 37.27±8.05mm. Maximum improvement was noted after 16.9±8.63 (6 to 36) months. CONCLUSION - Patients with serious cardiac failure and ventricular dysfunction caused by hypertension, alcoholism, or myocarditis can experience marked improvement in ventricular dysfunction after undergoing appropriate therapy within the venue of the doctor's office.
Resumo:
Endometriosis is a chronic condition affecting 10 to15% of women in childbearing age. Understanding the impact of this disease on women’s well-being is still a challenge, namely to intervene. Pain is the most current and troublesome symptom. Although medical treatments for pain relief are effective, recurrence rate remains significant, calling for a better understanding and development of new approaches for pain management. A group Cognitive Behavioral Therapy (CBT) for management of associated co-morbidities is suggested, paying special attention to Chronic Pelvic Pain (CPP). CBT design can be grounded on information collected from focus groups and a one-group exploratory trial. Evaluation of therapy effectiveness is possible to be performed by comparing group CBT to Usual Care (UC) and Support Group (SG) in a randomized controlled trial. Research in this area could represent an important step in providing a solution to the management of endometriosis and, to the best of our knowledge, the first national psychological approach for its understanding and treatment.
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.
Resumo:
OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.
Resumo:
OBJECTIVE: To analyze the efficacy of percutaneous transluminal septal alcoholization in the treatment of refractory obstructive hypertrophic cardiomyopathy (HOC). METHODS: The patients were referred for alcoholization after Doppler echocardiography. Before and after alcoholization, the intraventricular pressure gradient was recorded. Alcoholization was performed with a 3mL injection of absolute alcohol through a coronary angioplasty balloon catheter. The procedure was concluded after a significant reduction or abolition of the pressure gradient. RESULTS: Of 22 patients, 18 (81.8%) successfully concluded the procedure with a reduction in intraventricular pressure gradient at baseline (from 67.6±24.2 mmHg to 3.8± 1.9 mmHg, p<0.005) and after extrasystole (from 110.4± 24.2 mmHg to 9.6±2.6 mm Hg, p<0.005). A significant reduction in mean interventricular septal thickness (from 2± 0.3 mm to 1.7±0.2 mm, p<0.005) and in peak pressure gradient (from 90.7±23.5 mmHg to 6.1±1.4 mmHg, p<0.005) was observed on Doppler echocardiography after 6 months, when all patients were in functional class I. The most frequent acute complication, present in 11% of the patients, was the need for definitive pacing implantation. Relapse of the symptoms and reappearance of the pressure gradient occurred in 16.6% of the patients. One patient (5.5%) died probably due to a diffuse coronary spasm prior to the procedure, and another died suddenly on late follow-up. CONCLUSION: Percutaneous transluminal septal alcoholization is effective and safe in the treatment of HOC.