942 resultados para tightening torque


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ObjectiveTo study bone healing at implants installed with different insertion torques.Material and methodsIn six Labrador dogs, all mandibular premolars and first molars were extracted. After 4months of healing, flaps were elevated, and two implant sites were prepared at each side of the mandible. In the right side of the mandible, the distal sites were prepared conventionally, while the mesial sites were over-prepared by 0.2mm. As a consequence, a final insertion torque of similar to 30Ncm at the distal and a minimal insertion torque close to 0Ncm at the mesial sites were obtained. In the left sides of the mandible, however, the recipient sites were underprepared by 0.3mm resulting in an insertion torque of 70Ncm at both implants. Cover screws were applied, and flaps sutured to fully submerge the experimental sites. After 4months, the animals were sacrificed and ground sections obtained for histological evaluation.ResultsThe mineralized bone-to-implant contact was in the range of 55.2-62.1%, displaying the highest value at implants with similar to 30Ncm insertion torque and the lowest value at the implant sites with close to 0Ncm insertion torque. No statistically significant differences were revealed. Bone density was in the range of 43.4-54.9%, yielding the highest value at implants with 70Ncm insertion torque and the lowest at the implant sites with close to 0Ncm insertion torque. The difference between the sites of similar to 30Ncm and the corresponding 70Ncm insertion torque reached statistical significance.ConclusionsSimilar amounts of osseointegration were obtained irrespective of the insertion torque applied. Moreover, implants installed in sites with close to 0Ncm insertion torque may properly osseointegrate as well.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AimTo evaluate prospectively the clinical and radiographic outcomes after 5years of early loading of 6-mm implants with a moderately rough (SLActive((R))) surface supporting single crowns in the posterior regions.Material and methodsThirty-five consecutive patients received 40 SLActive((R)) (Straumann) 6-mm implants with a diameter of 4.1mm (n=19) or 4.8mm (n=21). Insertion torque and resonance frequency analysis (RFA) were measured at implant installation. RFA was also measured at abutment connection. SynOcta abutments were tightened with 35Ncm after 6weeks of healing, and single porcelain fuse to metal crowns was cemented within 1week. Implant survival rate and marginal bone loss were evaluated at various time intervals until 5years after loading. The clinical crown/implant ratio was calculated as well.ResultsTwo of 40 implants were lost before loading (incorporation rate 95%), and no further implant loss or technical complications were encountered during the 5-year follow-up period. A mean marginal bone loss of 0.70.6mm was found after 5years of function. The clinical crown/implant ratio increased with time from 1.6 at the delivery of the prosthesis to 2 after 5years of loading.ConclusionSix millimeter implants with a SLActive((R)) moderately rough surface supporting single crowns in the posterior region and loaded after 6-7weeks maintained full function for at least 5year with low marginal bone resorption.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A robotic control design considering all the inherent nonlinearities of the robot-engine configuration is developed. The interactions between the robot and joint motor drive mechanism are considered. The proposed control combines two strategies, one feedforward control in order to maintain the system in the desired coordinate, and feedback control system to take the system into a desired coordinate. The feedback control is obtained using State-Dependent Riccati Equation (SDRE). For link positioning two cases are considered. Case I: For control positioning, it is only used motor voltage; Case II: For control positioning, it is used both motor voltage and torque between the links. Simulation results, including parametric uncertainties in control shows the feasibility of the proposed control for the considered system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of the present study was to investigate possible differences towards strenght recovery measured by different methods and running economy (RE), after one session of downhill running (DR), in order to induce muscle damage (MD). Our hypothesis is that the strenght recovery measured by jumps is more alike RE markers, due to the measures' specificity. Ten male subjects, ages 18 to 30, apparently healthy, without any experience with strenght training at least 6 months before the tests took place in this study. After going to the lab twice (to familiarize themselves with the protocols, and determine their maximum oxygen consumption/running speeds), they went to the lab five times in the following week, in order to collect all the variables before, immediately after, and 24, 48, 72 and 96 hours in. The variables obtained were: stride frequency (SF), stride lenght (SL), oxygen volume (VO2), carbon dioxide volume (VCO2), ventilation (VE), lactate blood concentration ([Lac]), isometric peak torque (IPT), subjective pain perception (SPP), effort perception (EP), medial-portion circumference (CIR), knee movement extent (EXT), torque development rate (TDR), counter movement jump and squat jump height (HCM and HS), strenght development rate of both jumps (SDCM and SDS), and maximum soil strenght reaction (SRCM and SRS). Changes over time in all variables were verified by one way variancy analysis. Differences between the strenght measures were verified by two way variancy analysis. When significant effects were verified, Tuckey's post-hoc were applied. The significancy level taken on this study was p < 0,05. Of all indirect muscle damage markers, IPT, SPP and TDR were the only ones in which ocurred significant changes. We couldn't find the moments where this happened for TDR with the post-hoc used. On RE markers, VO2, [Lac] and VE suffered significant effects over time. About the jumps variables, only SDCM and HCM presented significant...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several methods are used towards delayed onset muscle soreness appraisal. This study's goal was to investigate, amongst three commonly adopted methods, which one would be the most effective (the one that shows higher values) in the quantification of this phenomenon. 10 male subjects, of age 22.8 ± 3.1 years old, weight 80 ± 12.4 kg, height 174 ± 0.07 cm, without recent experience with strength training (lower limbs) and/or running took place in this study. All subjects carried out a muscle damage induction protocol, which consisted of 30 minute downhill running (-16% or -9.09º) at 80% speed compared to their maximum oxygen consumption. Muscle damage determinants such as isometric peak torque, knee joint range of motion and circumference of the medial portion of the thight were measured before, during, 24, 48, 72 and 96 hours after downhill running. The subjective pain perception was measured simultaneously with the other determinants through three different tests: sitting on and getting up of a chair; climbing and descending from a 45cm step; and self thigh palpation. After going through all subjective pain perception tests, the subjects filled out a visual analog scale with their perception of pain. Muscle damage changes over time were compared through variance analysis (ANOVA) one way for repeated measures. Subjective pain perception values obtained in all three different tests were compared through two way ANOVAs for repeated numbers. The significance level adopted in this study was z ≤ 0.05. The results showed that the step test was the on which better evaluated the delayed onset muscle soreness. No significant differences were found through the ADM and CIR recovery markers. Downhil running determined reduced of PTI (~22.4%). Significant links between pain were obtained for both subjective pain perception tests starting at 24 and 48 hours, where the highest registered average happened in the step test after 48h, with high...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The root resorption is one of the possible sequels of greater complexity to the orthodontist, the difficulty of detection and be asymptomatic. The presence, during the orthodontic treatment, is linked to a multifactorial origin, a complex combination of biological activities, anatomical, physiological, genetic variables and mechanical forces. Thus, the aim of this study was perform to critical literature review related to root resorption in orthodontic movement. Were included articles published between 2004 to 2014, indexed in the PUBMED database. Used descriptors contained in the Mesh, being adopted as inclusion criteria: clinical trials in humans, only articles that had clear ideas and objective, articles with English language. The search strategy used resulted in 24 articles and after applied the inclusion and exclusion criteria, 11 articles remained. Based on the results of this study it was concluded that heavy forces of intrusion, inclination and torque leads to a greater degree of root resorption; its etiology is multifactorial, the periodic radiographic control during treatment is needed and further studies are suggested to identify more specifically the causes and risk factors for root resorption.