967 resultados para socket graft


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mixture of synthetic and natural materials yields a material with improved physical-chemical properties. One way of obtaining this kind of material is through graft copolymerization. Some natural materials have been used in graft copolymerization with synthetic monomers. In this work, graft copolymerization of butyl acrylate (BA) onto starch using a redox initiator system was carried out. The graft yield was evaluated for different reaction conditions. The graft copolymer was characterized by infrared spectroscopy, thermal analysis and scanning electron microscopy (SEM).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Stunting and stem necrosis were noticed in soybeans (Glycine max) grown in 2000/2001 in West Central Brazil the same condition was also observed in the following year in plantations as far as 2,000 km from the initial area. Based on transmission (mechanical, graft, insect vector), purification and serology, electron microscopy and molecular studies the causal agent was determined to be a whitefly-borne carlavirus which is possibly related to Cowpea mild mottle virus (CpMMV).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to characterize the cellular mechanisms leading to the beneficial effect of anti-oxidative gene therapy and pro-angiogenic stem cell therapy in acute peripheral ischemia. Post-ischemic events aim to re-establish tissue blood perfusion, to clear cellular debris, and to regenerate lost tissue by differentiation of satellite cells into myoblasts. Although leukocytes have an essential role in clearing cellular debris and promoting angiogenesis, they also contribute to tissue injury through excessive ROS production. First, we investigated the therapeutic properties of extracellular superoxide dismutase (SOD3) gene transfer. SOD3 was shown to reduce oxidative stress, to normalize glucose metabolism, and to enhance cell proliferation in the ischemic muscle. Analysis of the mitogenic Ras-Erk1/2 pathway showed SOD3 mediated induction offering a plausible explanation for enhanced cell proliferation. In addition, SOD3 reduced NF-κB activity by enhancing IκBα expression thus leading to reduced expression of inflammatory cytokines and adhesion molecules with consequent reduction in macrophage infiltration. Secondly, we sought to determine the fate and the effect of locally transplanted mesenchymal stem/stromal cells (MSCs) in acute ischemia. We showed that a vast majority of the transplanted cells are cleared from the injury site within 24 hours after local transplantation. Despite rapid clearance, transplantation was able to temporarily promote angiogenesis and cell proliferation in the muscle. Lack of graft-derived growth factor expression suggests other than secretory function to mediate this observed effect. In conclusion, both SOD3 and MSCs could be utilized to alleviate peripheral ischemia induced tissue injury. We have described a previously unidentified growth regulatory role for SOD3, and suggest a novel mechanism whereby transplanted MSCs enhance the reparative potential of the recipient tissue through physical contacts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bauhinia x blakeana (B. purpurea x B. variegata) is a natural hybrid that has been cultivated in gardens, streets and parks. Due to its sterility, it must be vegetatively propagated. The objective of this work was to evaluate the viability of cuttings and grafting on its propagation. Semi-woody cuttings were collected during four seasons and treated with 0; 1,000; 2,000; and 3,000 mg L-1 of IBA. The experimental design was entirely randomized and the treatments were arranged in a 4x4 factorial scheme (four collecting times x four IBA concentrations) and five replications with 10 cuttings each, per collecting time and per IBA concentration. Characteristics of roots and shoots were evaluated after 90 days. The data means were compared by the Tukey test and submitted to the polynomial regression analysis. For the grafting experiment, B. variegata and B. variegata var. candida plants of six and 12 months were used as rootstocks and the splice graft and T-budding methods were tested. The experimental design was entirely randomized and the treatments were arranged in a 2x2x2 factorial scheme (two rootstock species x two grafting methods x two rootstock ages) and four replications with five plants each, per rootstock species, per grafting method and per rootstock age. Characteristics of shoots were evaluated after 90 days and the data means were compared by the Tukey test. B. x blakeana can be propagated by semi-woody cuttings collected in spring, without IBA application, or in summer, with the application of 3,000 mg L-1 of IBA. The tested grafting methods were not effective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vascular complications after liver transplantation include oclusion or stenosis at the sites of anastomosis in the hepatic artery, portal vein, and vena cava. Balloon angioplasty of these stenosis carries little risk and is a useful procedure for the treatment of these problems. The purpose of this paper was to assess whether percutaneous transluminal angioplasty can help to prolong allograft survival and impruve allograft function in patient with hepatic artery stenosis after liver transplantation. We report a 43-year-old mate with stenosis of hepatic artery anastomosis after liver transplantation. An abrupt elevation of liver enzymes and serum bilirrubin levels was noted on the fifth postoperative month. The patient underwent percutaneous liver biopsy, which revealed important ductal depletion due to hypoperfusion, even though Doppler ultrasound examination demonstrated arterial flow. An angiogram confirmed severe stenosis of the arterial anastomosis with poor intraparenchymal arterial perfusion pattern. In an attempt to preserve the graft, a percutaneous transluminal angioplasty was performed using microballoons mounted on a hydrophylic micro guidewire. Intervention proceeded without complications. Liver enzimes and bilirrubin levels decreased within twenty-four hours of angioplasty. Normal levels were achieved after one week. Seven month after angioplasty, the patient is in a optimal clinical condition with no signs of graft impairment. We conclude that percutaneous transluminal angioplasty of hepatic artery stenosis after liver transplantation is relatively safe and may help decrease allograft loss.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present study is to report a sucessful pregnancy in a 28 year-old female who underwent an orthotopic liver transplantation two years ago due to type I auto immune he patitis. Patient was taking cyclosporin, prednisone and azathioprine for maintenance immunossupression and had good graft function during all the pregnancy. The liver function tests were normal during the pregnancy. Fetal growth was monitored by ultrasonographic examination and showed normal development. At the end of the third trimester, she was subjected to a cesarean bearing a healthy girl weighting 2,320 kg. She was discharged with normal liver functions tests and no complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our objective is to report a case of a patient with a descending thoracic aortic aneurysm and chronic aortic dissection, who was submitted to an endovascular treatment. A 68-year-old male with coronary artery disease and hypertension, with no history of trauma, diabetes or smoking. He had myocardial infarction ten years ago. Under general anesthesia, the left femoral artery was surgically exposed and the left braquial artery was catheterized with a "pigtail" catheter, under Seldinger technique. The proximal 46mm/Æ and distal 34mm/Æ stent-graft was placed just distal to the origen of the left subclavian artery. Control arteriography showed that the lesion was completely excluded. The patient was discharged seven days after the surgery, when a computed tomographic control, was performed showing a sustained aneurysm exclusion and a satisfactory endovascular position.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors present a case report of a victim of high power electric shock. The main electric lesion was a penetrating abdominal wound with loss of substance of the abdominal wall and an electric lesion of the hepatic segment and of the gallbladder. The surgical treatment included hepatic segmentectomy, cholecystectomy, repair of the abdominal wall with Marlex prosthesis and skin graft, besides the debridment of the lesions of extremities. The postoperative evolution was satisfactory and the follow-up for 6 months didn't show any sequelae.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abdominal aortic aneurysm reconstruction is usually performed in vascular surgical practice. However, the repair of an abdominal aortic aneurysm associated with a pelvic kidney is rare. Our goal is to present a case report of an abdominal aortic aneurysm associated with two congenital pelvic kidneys wich was treated successfully by aneurysmectomy and inclusion of an aortoaortic graft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a case of a 56-year-old woman with abdominal pain, normal laboratorial exams, normal carcinoembryonary antigen (CEA) and abdominal tomography exam with tumor formation in hepatic region. A tumor lesion was identified in a surgery in the medial segment of the inferior vena cava. A surgical resection was done, respecting the security limits, and reconstruction of the inferior vein with polytetrafluoroethylene (PTFE) graft was performed. The histological examination showed differentiated leiomyossarcoma of the inferior vena cava. This report points to the necessity of differential diagnoses with leiomyossarcoma in the presence of abdominal mass, supra-mesocolic, and non-specific abdominal symptoms, since its pre-surgical diagnoses occurs in only 5% to 10% of the cases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vascular complications after kidney transplantation have been described and pseudoaneurysms represent a well-recognized vascular complication. Although the incidence of pseudoaneurysm is low, it may potentially cause graft loss or may even be fatal for the patients if it is not diagnosed and treated quickly. The authors report a case of renal artery pseudoaneurysm diagnosed two months posttransplantation with cadaveric graft, the treatment and literature data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bioactive glasses (BGs) form a group of synthetic, surface-active, composition-dependent, silica-based biomaterials with osteoconductive, osteopromotive, and even angiogenic, as well as antibacterial, properties. A national interdisciplinary research group, within the Combio Technology Program (2003–2007), developed a porous load-bearing composite for surgical applications made of BG 1–98 and polymer fibers. The pre-clinical part of this thesis focused on the in vitro and in vivo testing of the composite materials in a rabbit femur and spinal posterolateral fusion model. The femur model failed to demonstrate the previously seen positive effect of BG 1–98 on osteogenesis, probably due to the changed resorption properties of BG in the form of fibers. The spine study was terminated early due to adverse events. In vitro cultures showed the growth inhibition of human mesenchymal stems next to BG 1–98 fibers and radical pH changes. A prospective, long-term, follow-up study was conducted on BG–S53P4 and autogenous bone used as bone graft substitutes for instrumented posterolateral spondylodesis in the treatment of degenerative spondylolisthesis (n=17) and unstable burst fractures (n=10) during 1996–1998. The operative outcome was evaluated from X-rays and CT scans, and a clinical examination was also performed. On the BG side, a solid fusion was observed in the CT scans of 12 patients, and a partial fusion was found in 5 patients, the result being a total fusion rate in all fusion sites (n=41) 88% for levels L4/5 and L5/S1 in the spondylolisthesis group. In the spine fracture group, solid fusion was observed in five patients, and partial fusion was found in five resulting in a total fusion rate of 71% of all fusion sites (n=21). The pre-clinical results suggest that under certain conditions the physical form of BG can be more critical than its chemical composition when a clinical application is designed. The first long-term clinical results concerning the use of BG S53P4 as bone graft material in instrumented posterolateral spondylodesis seems to be a safe procedure, associated with a very low complication rate. BG S53P4 used as a stand-alone bone substitute cannot be regarded as being as efficient as AB in promoting solid fusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työ tutkii, miten yksinkertaisen opetuskäyttöön suunnatun videoneuvotteluportaalin prototyypin rakentaminen onnistuu avoimilla tekniikoilla. WebRTC mahdollistaa selaimen päällä toimivan videoneuvottelusovelluksen rakentamisen avoimia ohjelmistorajapintoja käyttäen. Prototyypin toteuttamiseen käytetään WebRTC:n lisäksi WebSocket-standardia keskustelun tahojen yhdistämiseen. WebSocket toteutetaan Node.js:ää käyttävällä socket.io-kirjastolla. Sovelluksen avulla on tarkoitus pystyä muodostamaan ääni- ja videoyhteys kahden asiakasohjelman välille. Opetuskäyttöä tukevina ominaisuuksina mukana on myös tekstipohjainen keskustelu ja mahdollisuus opetuskalvojen selaamiseen. Lopputuloksena on laajennettavissa oleva avoin videoneuvottelusovelluksen prototyyppi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: to verify the effectiveness of the rubber elastic band in the treatment of large wounds of the body wall of rabbits by means of traction of its edges. METHODS: we studied 30 New Zealand rabbits, divided into three groups (n=10): Group 1- healing by secondary intention; Group 2- removal and eutopic repositioning of skin as full thickness skin graft; Group 3- Approximation of wound edges with elastic rubber band. In all animals, we removed a segment of the back skin and subcutaneous tissue down to the fascia, in accordance with an acrylic mold of 8cm long by 12cm wide. All animals were observed for 21 days. RESULTS: two animals of groups 1 and 2 had wound abscess. In Group 2, there was partial or total graft loss in 90% of animals. The complete closure of the wounds was observed in four animals of Group 1, six of Group 2 and eight of Group 3. There was no difference between the scar resistance values of groups 2 and 3, which were higher than those in Group 1. The scars of the three groups were characterized by the presence of mature connective tissue mixed with blood vessels and inflammatory infiltration, predominantly polymorphonuclear. CONCLUSION: the tensile strength of the wound edges with rubber elastic band is as efficient as the skin graft to treat rabbits' large body wounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.