970 resultados para retinal circulation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Quantification of retinal layers using automated segmentation of optical coherence tomography (OCT) images allows for longitudinal studies of retinal and neurological disorders in mice. The purpose of this study was to compare the performance of automated retinal layer segmentation algorithms with data from manual segmentation in mice using the Spectralis OCT. METHODS Spectral domain OCT images from 55 mice from three different mouse strains were analyzed in total. The OCT scans from 22 C57Bl/6, 22 BALBc, and 11 C3A.Cg-Pde6b(+)Prph2(Rd2) /J mice were automatically segmented using three commercially available automated retinal segmentation algorithms and compared to manual segmentation. RESULTS Fully automated segmentation performed well in mice and showed coefficients of variation (CV) of below 5% for the total retinal volume. However, all three automated segmentation algorithms yielded much thicker total retinal thickness values compared to manual segmentation data (P < 0.0001) due to segmentation errors in the basement membrane. CONCLUSIONS Whereas the automated retinal segmentation algorithms performed well for the inner layers, the retinal pigmentation epithelium (RPE) was delineated within the sclera, leading to consistently thicker measurements of the photoreceptor layer and the total retina. TRANSLATIONAL RELEVANCE The introduction of spectral domain OCT allows for accurate imaging of the mouse retina. Exact quantification of retinal layer thicknesses in mice is important to study layers of interest under various pathological conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To assess the effect of a bimonthly treatment regimen with intravitreal aflibercept on retinal fluid and pigment epithelial detachment (PED) in patients with neovascular age-related macular degeneration (AMD). METHODS Twenty-six treatment-naive eyes of 26 patients with choroidal neovascularisation secondary to AMD were included. The patients received three initial monthly (mean 30 days) intravitreal injections of aflibercept followed by a bimonthly (mean 62 days) fixed regimen for a total of 1 year. Best-corrected visual acuity (BCVA) and optical coherence tomography (OCT) measurements were recorded at monthly intervals. In addition, the presence of intraretinal fluid (IRF) or subretinal fluid (SRF) or a combination of both as well as serous and fibrovascular PEDs were assessed. RESULTS The mean patient age was 80 years (range 54-93). There were 14 male and 12 female patients. The mean gain in BCVA at 1 year was 9.3 letters (SEM ±3) with a mean reduction of the central retinal thickness of 154 µm (SEM ±50). After 3 monthly injections of aflibercept, there was resolution of IRF and SRF in 80% of the treated eyes; the amount of fluid increased at months 4, 6 and 8 with troughs in between. Whereas fibrovascular PEDs remained stable after the loading phase, serous PEDs displayed a seesaw pattern. Patients without retinal pigment epithelium (RPE) atrophy at the end of the 1-year period had significantly better BCVA compared to patients with RPE atrophy (p = 0.03). CONCLUSION Despite significant overall BCVA gain, bimonthly intervals seem insufficient to maintain the morphological improvements after the initial loading dose with intravitreal aflibercept.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

δ¹³ CO₂ measured in Antarctic ice cores provides constraints on oceanic and terrestrial carbon cycle processes linked with millennial-scale changes in atmospheric CO₂. However, the interpretation of δ¹³ CO₂ is not straight-forward. Using carbon isotope-enabled versions of the LOVECLIM and Bern3D models, we perform a set of sensitivity experiments in which the formation rates of North Atlantic Deep Water (NADW), North Pacific Deep Water (NPDW), Antarctic Bottom Water (AABW), and Antarctic Intermediate Water (AAIW) are varied. We study the impact of these circulation changes on atmospheric δ¹³ CO₂ as well as on the oceanic δ¹³ CO₂ distribution. In general, we find that the formation rates of AABW, NADW, NPDW, and AAIW are negatively correlated with changes in δ¹³ CO₂: namely, strong oceanic ventilation decreases atmospheric δ¹³ CO₂. However, since large-scale oceanic circulation reorganizations also impact nutrient utilization and the Earth’s climate, the relationship between atmospheric δ¹³ CO₂ levels and ocean ventilation rate is not unequivocal. In both models atmospheric δ¹³ CO₂ is very sensitive to changes in AABW formation rates: increased AABW formation enhances the transport of low δ¹³ CO₂ waters to the surface and decreases atmospheric δ¹³ CO₂. By contrast, the impact of NADW changes on atmospheric δ¹³ CO₂ is less robust and might be model dependent. This results from complex interplay between global climate, carbon cycle, and the formation rate of NADW, a water body characterized by relatively high δ¹³ CO₂.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Introduction: Carotid endarterectomy (CEA) and coronary artery bypass grafting (CABG) could be approached in a combined or a staged fashion. Some crucial studies have shown no significant difference in peri-operative stroke and death rate in combined versus staged CEA/CABG. At present conventional extracorporeal circulation (CECC) is regarded as the gold standard for performing on-pump coronary artery bypass grafting. On contrary, the use of minimized extracorporeal circulation (MECC) for CABG diminishes hemodilution, blood-air contact, foreign surface contact and inflammatory response. At the same time, general anaesthesia (GA) is a potential risk factor for higher perioperative stroke rate after isolated CEA, not only for the ipsilateral but also for the contralateral side especially in case of contralateral high-grade stenosis or occlusion. The aim of the study was to analyze if synchronous CEA/CABG using MECC (CEA/CABG group) allows reducing the perioperative stroke risk to the level of isolated CEA performed under GA (CEA-GA group). – Methods: A retrospective analysis of all patients who underwent CEA at our institution between January 2005 and December 2012 was performed. We compared outcomes between all patients undergoing CEA/CABG to all isolated CEA-GA during the same time period. The CEA/CABG group was additionally compared to a reference group consisting of patients undergoing isolated CEA in local anaesthesia. Primary outcome was in-hospital stroke. – Results: A total of 367 CEAs were performed, from which 46 patients were excluded having either off-pump CABG or other cardiac surgery procedures than CABG combined with CEA. Out of 321 patients, 74 were in the CEA/CABG and 64 in the CEA-GA group. There was a significantly higher rate of symptomatic stenoses among patients in the CEA-GA group (p<0.002). Three (4.1%) strokes in the CEA/CABG group were registered, two ipsilateral (2.7%) and one contralateral (1.4%) to the operated side. In the CEA-GA group 2 ipsilateral strokes (3.1%) occurred. No difference was noticed between the groups (p=1.000). One patient with stroke in each group had a symptomatic stenosis preoperatively. – Conclusions: Outcome with regard to mortality and neurologic injury is very good in both -patients undergoing CEA alone as well as patients undergoing synchronous CEA and CABG using the MECC system. Although the CEA/CABG group showed slightly increased risk of stroke, it can be considered as combined treatment in particular clinical situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Minimized Extracorporeal Circulation does not impair cognitive brain function after coronary artery bypass grafting – – Objectives – Objective evaluation of the impact of minimized extracorporeal circulation (MECC) on perioperative cognitive brain function in coronary bypass grafting (CABG) by Electroencephalogram (EEG) P 300 wave event related potentials (ERP) and number connection test ( NCT) as metrics of cognitive function. – – Methods – Cognitive brain function was assessed in 31 patients with a mean age of 65y (Standard Deviation/SD 10) undergoing coronary artery bypass grafting (CABG) by the use of MECC with P300 auditory evoked potentials (peak latencies in milliseconds [ms]) directly prior to intervention, 7 days after and 3 month later. Number connection test (NCT), serving as method of control, was performed simultaneously in all patients. – – Results – Seven days following CABG, cognitive P300 evoked potentials were comparable to preoperative baseline values (vertex [Cz] 376 (SD 11) ms vs. 378 (18) ms, p=0.39, frontal [Fz] 377 (11) vs. 379 (21) ms, p=0.53). Cognitive brain function showed at 3 months compared to baseline values ([Cz] 376 (11) ms vs. 371 (14 ms) p=0.09, [Fz] 377 (11) ms vs. 371 (15) ms, p=0.04. Between the first postoperative measurement and 3 months later, significant improvement was observed ([Cz] 378 (18) ms vs. 371 (14) ms, p=0.03, [Fz] 379 (21) vs. 371 (15) ms, p=0.02). Similar clearly corresponding patterns could be obtained via number connection test. Results could be confirmed in repeated measures analysis of variance for Cz (p = 0.05) and (Fz) results (p = 0.04). – – Conclusions