990 resultados para mobilidade de bases
Resumo:
Transport systems involved the use of territory in different Brazilian cities with regard to the occupation of road systems in urban areas. The implementation of systems engineering and transport infrastructure such as roads (roads), signs, stops, stations and complex road (bridges, viaducts and tunnels) are not used in the same way in the area. The subway is not even use the bus and vice versa. The time spent in travel, the time to access and the number of trips made by passengers in each way of transport is not the same. The use of transport systems in the territory, therefore, takes place through a whole in the current period we are in the technicalscientific and informational. This work addresses, however, the area used as a synonym of geographical area, analyzed by two categories of analysis, systems of objects formed by the fixed and the systems formed by the action flows. The system analyzed is the public transport by bus and population displacement that makes using this medium with source destination from home to work and has as empirical cut the Lagoa Azul located in the district administrative area north of Natal / RN. The general objective of this research is to understand the extent to which public transport has contributed to the socio-spatial accessibility of the residents of Barrio Blue Lagoon, located in Natal-RN, emphasizing the way home and the workplace. To reach the general objective of this dissertation, a study was made in light of the line which the methodological empirical facts, statistical data and theoretical knowledge of the events that occur in the quarter related to the Lagoa Azul economic aspects. Use for this, the concepts of mobility and Accessibility
Resumo:
A acupuntura (AP) é uma técnica terapêutica empírica desenvolvida em uma cultura oriental e que utiliza pensamento mágico (linguagem pré-científica) em seu raciocínio. É uma terapia reflexa que utiliza a estimulação de pontos específicos do corpo com objetivo de atingir um efeito terapêutico ou homeostático. A AP preconiza que a saúde é dependente das funções psico-neuro-endócrinas, sob influência do código genético e de fatores extrínsecos como nutrição, hábitos de vida, clima, qualidade do ambiente, entre outros. O presente artigo faz uma breve revisão sobre a filosofia da AP, seus marcos históricos na China e no Ocidente, a história da AP veterinária no Brasil e no mundo. Também aborda a prática da AP, incluindo as formas de diagnóstico, a definição do protocolo de tratamento, os métodos de estimulação dos pontos, o agulhamento de animais, suas indicações, contra-indicações e reações adversas.
Resumo:
Statement of problem. Microwave irradiation has been suggested as a method to disinfect denture bases. However, the effect of microwave heating on the dimensional stability of the relined denture bases is unknown.Purpose. The purpose of this study was to evaluate the dimensional stability of intact and relined acrylic resin denture bases after microwave disinfection.Material and methods. A standard brass cast simulating an edentulous maxillary arch was machined and used to fabricate 2- and 4-mm-thick denture bases (n=200), which were processed with heat-polymerized acrylic resin (Lucitone 550). The 2-mm thick-specimens (n=160) were relined with 2 mm of autopolymerizing resin (Tokuso Rebase Fast, Ufi Gel Hard, Kooliner, or New Truliner). Distances between 5 removable pins on the standard brass cast were measured with a Nikon optical comparator, and the area (mm(2)) formed by the distance between 5 pins was calculated and served as baseline. During fabrication, the pins were transferred to the intaglio surface of the specimens. Differences between the baseline area and those subsequently determined for the specimens were used to calculate the percent dimensional changes. The intact and relined denture bases were divided into 4 groups (n=10) and evaluated after: polymerization (control group P); 1 cycle of microwave disinfection (MW); daily microwave disinfection for 7 days (control group MW7); water storage for 7 days (WS7). Microwave irradiation was performed for 6 minutes at 650 W. Data were analyzed using 2-way ANOVA followed by Tukey's test (alpha=.05).Results. Intact specimens and those relined with Kooliner and New Truliner showed increased shrinkage after 1 (P=.05, .018, and .001, respectively) and 7 (P <.001, .003, and <.001, respectively) cycles of microwave disinfection. With the exception of specimens relined with Kooliner, intact specimens showed greater shrinkage than the relined specimens after 7 cycles of microwave disinfection.Conclusions. Microwave disinfection produced increased shrinkage of intact specimens and those relined with New Truliner and Kooliner.
Resumo:
Statement of problem. Denture bases may become increasingly weaker as a result of thermal stress and flexural cyclic loading. Information regarding this potential problem and its relationship to the denture base reline is limited.Purpose. This study evaluated the influence of thermal and mechanical stresses on the strength of intact and relined denture bases.Material and methods. Twenty-eight microwave-polymerized (Acron MC) intact denture bases were prepared in the shape of a 3-mm-thick maxillary denture. Additionally, fifty-six 2-mm-thick denture bases were relined with 1 mm of autopolymerizing resin (Tokuyama Rebase Fast II or New Truliner) (n = 28). Intact and relined specimens were divided into 4 groups (n = 7) as follows: without stress (control); a mechanical stress at 0.8 Hz for 10,000 cycles; 5000 thermal cycles between 5 degrees C and 55 degrees C; or a combination thermo-mechanical stress. The specimens were vertically loaded in compression with a rounded rod at 5 mm/min until failure, using a universal testing machine. Data on maximum fracture load (N), deflection at fracture (%), and fracture energy (N-mm) were analyzed by 2-way analysis of variance and Student-Newman-Keuls tests (alpha = .05).Results. The strength of the denture bases relined with New Truliner was not significantly affected by any of the experimental conditions, but comparing the control groups, New Truliner exhibited the lowest maximum fracture load values. The maximum fracture load of intact denture bases (P = .002) and those relined with Tokuyama Rebase Fast II (P = .01) showed a significant decrease after thermal stress. Additionally, cyclic loading significantly decreased the maximum fracture load (P < .001), deflection at fracture (P = .025), and fracture energy (P < .001) of intact denture bases and those relined with Tokuyama Rebase (P values of .002, .039, and .001, respectively).Conclusion. Thermal and mechanical stresses exert deleterious effects on the strength of intact and/or relined denture bases, which vary according to the relining material used.
Resumo:
This study evaluated the influence of microwave disinfection on the strength of intact and relined denture bases. Water sorption and solubility were also evaluated. A heat-polymerized acrylic resin (Lucitone 550) was used to construct 4-mm-thick (n = 40) and 2-mm-thick (n = 160) denture bases. Denture bases (2mm) were relined with an autopolymerizing resin (Tokuso Rebase Fast, Ufi Gel Hard, Kooliner, or New Truliner). Specimens were divided into four groups (n = 10): without treatment, one or seven cycles of microwave disinfection (650 W for 6 min), and water storage at 37 degrees C for 7 days. Specimens were vertically loaded (5 mm/min) until failure. Disc-shaped specimens (50 min x 0.5 mm) were fabricated (n = 10) to evaluate water sorption and solubility. Data on maximum fracture load (N), deflection (%), and solubility (%) were analyzed by two-way analysis of variance and Student-Newman-Keuls tests (alpha = 0.05). One cycle of microwave disinfection decreased the deflection at fracture and fracture energy of Tokuso Rebase Fast and New Truliner specimens. The strength of denture bases microwaved daily for 7 days was similar to the strength of those immersed in water for 7 days. Microwave disinfection increased the water sorption of all materials and affected the solubility of the reline materials. (C) 2007 Wiley Periodicals, Inc.
Resumo:
Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.
Resumo:
A proposta deste estudo foi analisar o efeito de um programa de treinamento de membros superiores baseado nas técnicas de facilitação neuromuscular proprioceptiva (FNP) sobre a mobilidade torácica. Foram estudadas 24 voluntárias sedentárias, idade 22,9 ± 2,9 anos, divididas em grupo controle (GC), que não participou do treinamento, e grupo treinado (GT). O protocolo de treinamento físico foi constituído por um programa de exercícios de FNP, realizado três vezes por semana, durante quatro semanas. Os dois grupos foram submetidos à avaliação da mobilidade torácica por meio de cirtometria, antes e após o período de treinamento. Os dados colhidos foram analisados estatisticamente, com nível de significância α = 5%. Os valores da cirtometria axilar e xifoideana do GC antes e após o período de intervenção não apresentaram alterações significativas (p>0,05). No GT os valores das variáveis foram significantemente maiores após a intervenção (p<0,05). em conclusão, o protocolo de FNP utilizado parece ser um programa de exercícios eficiente, por promover aumento na cirtometria em um curto período de tempo, sugerindo que pode ser utilizado como recurso fisioterapêutico para o desenvolvimento da mobilidade torácica.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
As alterações que envolvem as globinas devem-se a modificações em genes responsáveis pela seqüência e estrutura das cadeias polipeptídicas, bem como aos genes reguladores da síntese destas cadeias. Hemoglobinas variantes apresentam estrutura química diferente da hemoglobina normal correspondente, resultante de mutações em uma ou mais bases nitrogenadas, ocasionando a troca de aminoácidos nas globinas alfa, beta, delta ou gama. A hemoglobina N-Baltimore é uma variante de globina beta, com substituição da lisina, na posição 95, por ácido glutâmico, apresentando mobilidade eletroforética mais rápida que a hemoglobina A em pH alcalino. Nas análises eletroforéticas em pH alcalino realizadas em doadores de sangue do Hemocentro de São José do Rio Preto (SP) identificamos a presença de portador de hemoglobina rápida em heterozigose, posteriormente confirmada por focalização isoelétrica e cromatografia líquida de alta pressão (HPLC). Os estudos de hemoglobinas anormais em doadores de sangue permitem a identificação de variantes raras e possibilitam o aconselhamento genético adequado a cada caso com estudo familial.
Resumo:
Hulthen's potential admits analytical solutions for its energy eigenvalues and eigenfunctions corresponding to zero orbital angular momentum stales, but its non zero angular momentum states are not equally known. This work presents a vibrational-rotational analy sis of Hulthen's potential using hydrogenic eigenfunction bases, which may be of interest and useful to students of quantum mechanics at different stages.
Resumo:
Este artigo mostra os dispositivos legais inclusos na Nova Lei de Diretrizes e Bases da Educação Nacional (LDB), visando identificar, compreender e avaliar a intencionalidade de suas propostas para a adoção de posturas pertinentes. Contém observações que possam ser consideradas nos estudos e reflexões sobre os rumos dos cursos e programas de formação de professores para a educação básica.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)