883 resultados para linear morphometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we use a nonlinear control based on Optimal Linear Control. We used as mathematical model a Duffing equation to model a supporting structure for an unbalanced rotating machine with limited power (non-ideal motor). Numerical simulations are performed for a set control parameter (depending on the voltage of the motor, that is, in the static and dynamic characteristic of the motor) The interaction of the non-ideal excitation with the structure may lead to the occurrence of interesting phenomena during the forward passage through the several resonance states of the system. Chaotic behavior is obtained for values of the parameters. Then, the proposed control strategy is applied in order to regulate the chaotic behavior, in order to obtain a periodic orbit and to decrease its amplitude. Both methodologies were used in complete agreement between them. The purpose of the paper is to give suggestions and recommendations to designers and engineers on how to drive this kind of system through resonance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The separation methods are reduced applications as a result of the operational costs, the low output and the long time to separate the uids. But, these treatment methods are important because of the need for extraction of unwanted contaminants in the oil production. The water and the concentration of oil in water should be minimal (around 40 to 20 ppm) in order to take it to the sea. Because of the need of primary treatment, the objective of this project is to study and implement algorithms for identification of polynomial NARX (Nonlinear Auto-Regressive with Exogenous Input) models in closed loop, implement a structural identification, and compare strategies using PI control and updated on-line NARX predictive models on a combination of three-phase separator in series with three hydro cyclones batteries. The main goal of this project is to: obtain an optimized process of phase separation that will regulate the system, even in the presence of oil gushes; Show that it is possible to get optimized tunings for controllers analyzing the mesh as a whole, and evaluate and compare the strategies of PI and predictive control applied to the process. To accomplish these goals a simulator was used to represent the three phase separator and hydro cyclones. Algorithms were developed for system identification (NARX) using RLS(Recursive Least Square), along with methods for structure models detection. Predictive Control Algorithms were also implemented with NARX model updated on-line, and optimization algorithms using PSO (Particle Swarm Optimization). This project ends with a comparison of results obtained from the use of PI and predictive controllers (both with optimal state through the algorithm of cloud particles) in the simulated system. Thus, concluding that the performed optimizations make the system less sensitive to external perturbations and when optimized, the two controllers show similar results with the assessment of predictive control somewhat less sensitive to disturbances

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo teve por objetivo avaliar o efeito da utilização de níveis crescentes do gluconato de sódio sobre o desempenho, o rendimento de carcaça e de partes e a morfometria da mucosa intestinal de frangos de corte de 22 a 42 dias de idade. Foram utilizados 1200 frangos de corte da linhagem Cobb, distribuídos em um delineamento inteiramente casualizado, envolvendo cinco tratamentos (0,00; 0,10; 0,20; 0,30 e 0,40% de gluconato de sódio) com oito repetições de 30 aves cada parcela. As variáveis foram submetidas à análise de variância e em caso de significância estatística foram realizadas análises de regressão pelos modelos polinomial e quadrático. A inclusão do gluconato de sódio não afetou o desempenho e o rendimento de carcaça e de partes. Entretanto, exerceu efeito benéfico sobre a morfometria da mucosa intestinal do duodeno e do jejuno.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Placa e espaçador de polímero derivado do óleo de mamona (PDOM) (Ricinus communis) foram avaliados clínica, radiográfica e histologicamente na tração linear, fixação e fusão vertebral cervical em 20 cães adultos, sem raça definida, pesando entre 17 e 22kg. Foram sacrificados quatro animais aos 10, 30, 60, 90 e 120 dias de pós-operatório. Após exposição da coluna cervical, por acesso ventral, o disco intervertebral de C4-C5 foi fenestrado e a abordagem ao canal medular foi feita por meio de fenda óssea. Um espaçador de PDOM foi colocado preenchendo o defeito ósseo. Os corpos vertebrais C4-C5 foram fixados com placa do mesmo material, utilizando-se dois parafusos corticais em cada corpo vertebral. Apenas um animal apresentou déficit neurológico no pós-operatório imediato. Radiograficamente as vértebras mostravam-se normais e alinhadas, sem colapso do espaço intervertebral, porém não houve neoformação óssea entre as vértebras. Ao exame mielográfico, não houve compressão da medula espinhal. Os implantes foram efetivos em manter a tração linear e fixação das vértebras cervicais e não ocorreu a fusão vertebral.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The caroticoclinoid foramen is an inconstant structure, formed by the union of the anterior and middle clinoid processes. The aim of this study was to perform an incidence and morphometry of the caroticoclinoid foramen in Brazilian human skulls and discuss its clinical implications. Eighty dry human skulls with sex distinction were used, and 3 groups of incidence were determined: General, sex, and sides. The morphometry was performed using a manual caliper and the major diameter of the foramina was measured; the values were also divided in general, according to sex and sides. The incidence of skulls with at least one foramen was 8.5%. According to the sides, 8.5% of the skulls showed foramen on the right side and 2.5% on the left. We found 2.5% of the skulls with bilateral foramen and 6.25% with unilateral foramen. In relation to sex, the foramens were found in 5% of male skulls and 12.5% of female skulls. The major diameter of this structure presented on mean, values of 5.23 mm on general, 5.18 mm on the right side and 5.35 mm on the left, 5.30 mm in male skulls and 5.18 mm in female skulls. The anatomical characteristics of this foramen should be considered in view of its clinical implications associated with neurosurgery as clinoid process removal, and symptoms as headache due to internal carotid artery alterations in this region. In conclusion knowledge of this structure supports the diagnosis and treatment of clinical complications related to this variation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.Methods: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc).Results: Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric.Conclusions: All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the effect of disinfection by immersion in sodium perborate (50 degrees C/10 min) or microwave irradiation (650 W/6 min) on the linear dimensional change (LDC) of four reline resins (Kooliner-K, New Truliner-N, Tokuso Rebase Fast-T, Ufi Gel Hard-U) and one heat-polymerizing denture base resin (Lucitone 550-L). Methods: Specimens (50.0 mm diameter, 0.5 mm thickness) were made using a split mold with reference points, and divided into two controls and four test groups (u = 8). The distances between the points were measured on the mold (baseline readings), and compared to those obtained from the specimens after: polymerization or immersion in water (37 degrees C) for 7 days (controls); 2 or 7 cycles of disinfection by immersion or microwave irradiation. Results: the two-way ANOVA and Tukey's test (alpha = 0.05) showed that microwave disinfection significantly increased the mean LDC of materials L (-1.43%), N (-1.27%) and K (-1.06%). Material N also exhibited a significant increase in LDC after two cycles of chemical disinfection (-0.73%). For U (-0.47%) and T (-0.21%) materials, no significant changes in LDC were found. Conclusions: Microwave disinfection increases the shrinkage of materials L, N, and K. The dimensional stability of resins U and T was not affected by the disinfection methods evaluated. (c) 2006 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this paper was to analyze the influence of incorporation of disinfectants during the cast die stone-setting time. Setting time, linear dimensional stability, and reproduction details on casts were measured.Materials and Methods: Die stone type IV specimens with disinfection solutions (sodium hypochlorite 1%, glutaraldehyde 2%, chlorhexidine 2%) were incorporated in two concentrations (50%, 100%). The detail reproduction, dimensional stability, and setting time were tested in accordance with ADA recommendations.Results: Disinfecting solutions promoted an increase in setting time compared to control; sodium hypochlorite was responsible for the highest setting time. The addition of undiluted sodium hypochlorite 1.0% led to contraction during setting, but the groups with 50% diluted sodium hypochlorite 1.0% and undiluted chlorhexidine 2.0% resulted in intermediate values compared to the other groups, thus matching the control. The others did not demonstrate any effect on expansion. For detail reproduction, it was observed that the control group presented results similar to the others, except those where sodium hypochlorite was added.Conclusions The addition of sodium hypochlorite in both dilutions significantly altered, negatively, all the evaluated properties. But the addition of glutaraldehyde and chlorhexidine did not promote any significant alterations in the evaluated properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)